Methylmercury in water samples at the pg/L level by online preconcentration liquid chromatography cold vapor-atomic
fluorescence spectrometry
Christoph-Cornelius Brombach, Bin Chen, Warren T. Corns, Jrg Feldmann, Eva M. Krupp
Spectrochimica Acta Part B: Atomic Spectroscopy, Volume 105, 1 March 2015, Pages 103-108
Direct online HPLC-CV-AFS method for traces of methylmercury without derivatisation: a matrix-independent method for
urine, sediment and biological tissue samples
Christoph-Cornelius Brombach, Zuzana Gajdosechova, Bin Chen, Andrew Brownlow, Warren T. Corns, Jrg
Feldmann, Eva M. Krupp
Analytical and Bioanalytical Chemistry, January 2015, Volume 407, Issue 3, pp 973-981
Quick and robust method for trace determination of MeHg in rice and rice products without derivatisation
Christoph-Cornelius Brombach, Mohamed Farouk Ezzeldin,Warren T. Corns, Bin Chen, Jrg Feldmann, Eva M. Krupp
Submitted to Journal of Analytical Atomic Spectrometry, April 2015
Trace Levels of Neurotoxic Methylmercury in commercial baby-food rice and other rice products vary by more than an order
of magnitude
Christoph-Cornelius Brombach, Bin Chen, Warren T. Corns, Jrg Feldmann, Eva M. Krupp
Submitted to Environmental Science and Technology, April 2015
Accurate fast screening for total and inorganic arsenic in rice grains using hydride generation atomic fluorescence
spectrometry (HG-AFS)
Bin Chen, Warren T. Corns, Peter B. Stockwell and Jen-How Huang
Anal. Methods, 2014,6, 7554-7558
10.820 HG-AFS
4 min/run
Aqua Regia or
Hot Bromination CV-AFS
Hg 2h 2 min/run
Wastewater
10.820 CV-AFS
4 min/run
Online Preparation Chemistry
As Speciation in Natural Water without
1200
1000
Blank
200
0
0 5 time / min 10 15
Correlation coefficient Linear plot
b
d
Figure: Calibration of As(III) (a), DMA )(b), MMA (c) and As(V) (d) in the range of 0 to 20 g L -1 (lowest standard: 0.5 g L-1);
error bars represent one standard deviation (n=3). The equation gives the linear trendline for the calibration points and the
correlation coefficient R2.
Hydrogen as a support for the flame
Advantages
(1) Less NaBH4 consumption
(2) Lower baseline and less noise
(3) Better sensitivity and stability
(4) Flexible reagent concentrations and flow rates
800
700
600
500 Blank
AFS signal 0.5 ppb
400 1 ppb
5 ppb
300
10 ppb
20 ppb
200
100
0
0 2 4 6 8 10 12 14
time / min
50 L injection loop
As in Wastewater
SeMet Se(VI)
Se-cystine
Se(VI)
Se(IV)
Se(IV)
SeMet
Se-cystine Se(VI)
Se in FGD Wastewater
1600 120 0,0 5,0
10,0 15,0
20,0 25,0
FGD-Europe
1400 30,0
100
FGD-Europe Spike
1200
FGD-USA
80
1000
800 60
600
40
400
20
200
0
0
Se 1 ppb
Se(IV) Se(VI)
SeCN
0 5 10 15 20 25 30
Methylmercury in Sediment
450
400
Hg(II)
350
300
250
200
Et-Hg (IS)
150 Me-Hg
100
50
0
0 1000 2000 3000 4000
Time (s)
oxidant reductant
waste Detector
HPLC column
sample
HPLC HPLC CV-AFS
pump 1 pump 2
UV GLS
sample Mobile phase
cooler
y = 108,6x + 34,817 5
600
R = 0,9993
500 4
Peak Area
400 3
300 2
200
1
0,5
100
0
0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Methylmercury / ng L-1
Sample preparation for rice
1. 300 mg rice + 3 mL TMAH
2. Microwave digestion (20 min at 55 C + 20 min at 60 C)
3. Addition of 2 mL HCl and ultrasonication for 10 min
4. Ultracentrifugation at 13000 rpm
5. Dilution of the supernatant to 50 mL for preconcentration
MeHg in rice
4
c(MeHg in g kg -1 -- ID -GC-ICP-MS
y = 1,0318x + 0,0003
R = 0,9663 9 rice samples from local
3 supermarkets and stores
were analysed with prec.
>
0
0 1 2 3 4
c(MeHg) in g kg-1 --> prec HPLC-CV-AFS
Conclusions
Accurate and precise results can be obtained with
AFS.
Compact design of 10.820 aim to reduce cost and
save lab space
Sample preparation simplified to almost zero for
some total analysis.
Conversion to the correct oxidation state can be
easily achieved.
PSA have developed methodologies and
international standards for numerous sample types
and applications.
PSA offer first class assistance for applications and
technical support.
Contact Us for Further Information
P S Analytical UK Office
: Arthur House,CrayfieldsIndustrial Estate,
Main Road, Orpington, Kent, BR5 3HP, UK
P S Analytical US Office: 1761 W. Hillsboro Blvd. Suite. 318,
Deerfield Beach, FL 33442, USA
www.psanalytical.com