June 2002
PIP VEDTA003
Atmospheric Storage Tank
Data Sheet and Instructions
(in Accordance with API Standard 650)
PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES
In an effort to minimize the cost of process industry facilities, this Practice has
been prepared from the technical requirements in the existing standards of major
industrial users, contractors, or standards organizations. By harmonizing these
technical requirements into a single set of Practices, administrative, application, and
engineering costs to both the purchaser and the manufacturer should be reduced. While
this Practice is expected to incorporate the majority of requirements of most users,
individual applications may involve requirements that will be appended to and take
precedence over this Practice. Determinations concerning fitness for purpose and
particular matters or application of the Practice to particular project or engineering
situations should not be made solely on information contained in these materials. The
use of trade names from time to time should not be viewed as an expression of
preference but rather recognized as normal usage in the trade. Other brands having the
same specifications are equally correct and may be substituted for those named. All
Practices or guidelines are intended to be consistent with applicable laws and
regulations including OSHA requirements. To the extent these Practices or guidelines
should conflict with OSHA or other applicable laws or regulations, such laws or
regulations must be followed. Consult an appropriate professional before applying or
acting on any material contained in or suggested by the Practice.
This Practice is subject to revision at any time by the responsible Function Team and
will be reviewed every 5 years. This Practice will be revised, reaffirmed, or withdrawn.
Information on whether this Practice has been revised may be found at www.pip.org.
PIP will consider requests for interpretations (inquiries) for this Practice. Instructions for
preparing inquiries are available on the PIP website at www.pip.org.
PRINTING HISTORY
June 2000 Issued
June 2002 Editorial Revision
PIP VEDTA003
Atmospheric Storage Tank
Data Sheet and Instructions
(in Accordance with API Standard 650)
Table of Contents
1. Introduction .................................. 2
1.1 Purpose ............................................. 2
1.2 Scope................................................. 2
2. References ................................... 2
2.1 Process Industry Practices ................ 2
2.2 Industry Codes and Standards .......... 2
2.3 Government Documents.................... 3
2.4 Other Government Documents.......... 4
4. Specific Instructions.................... 4
4.1 Line-by-Line Instructions.................... 4
4.2 Tank Plan and Sketches.................. 23
1. Introduction
1.1 Purpose
This Practice provides guidance to purchasers (owners, engineering contractors, and
other designated agents) and manufacturers (fabricators and erectors) for the
preparation and completion of the Atmospheric Storage Tank Data Sheet (hereafter
referred to as the Data Sheet). The Data Sheet shall be prepared in conjunction with
PIP VESTA002 such that comprehensive proposals (bids) may be made and
subsequent purchase orders may be placed for the fabrication and erection of tanks
per API Standard 650 (hereafter referred to as API 650).
1.2 Scope
This Practice explains information to be placed on the Data Sheet primarily by
purchasers for use by manufacturers. However, some of the instructions apply to
either the purchaser or the manufacturer, depending on which party assumes certain
responsibilities.
2. References
Requirements in the latest edition (or edition indicated) of the following codes, standards,
and references shall be considered an integral part of this Practice. Short titles will be used
herein when appropriate.
EPA 40 CFR Part 264 - Standards for Owners and Operators of Hazardous
Waste Treatment, Storage, and Disposal Facilities (RCRA)
Subpart J - Tank Systems
4. Specific Instructions
7. Design Parameters
Maximum Operating Temperature: Often called the design temperature
(the highest metal temperature for which the tank is to be designed).
Differs from the usual operating temperature. For temperature limits,
see API 650, Section 1.1.1, and Appendices M and S.
Design Metal Temperature*: Enter either lowest 1-day mean
temperature plus 15F or a lower temperature as specified by the
purchaser if operating conditions and/or local atmospheric conditions
control fracture toughness issues.
Roof Maximum Operating Temperature*: Specify only when different
from shell and bottom temperatures, as in the case of an uninsulated
roof on an insulated shell.
Design Liquid Level*: See API 650, Sections 3.6.3.2, C.3.1, and E.8,
and PIP VESTA002, Sections 3.6.C and E.8.B.
Design Pressure: Specify pressure and units in the vapor space.
Partial Vacuum: See PIP VESTA002, Section 3.2.E for units.
Maximum Fill Rate: Specify rate and units (e.g., 100 gallons per
minute).
Maximum Emptying Rate: Specify rate and units (e.g., 75 gallons per
minute).
Flotation Considerations (Yes/No): Indicate if required. Include design
consideration that advise the manufacturer about flotation anchorage,
bottom uplift, and partial submersion pressures arising out of flood or
dike impoundment.
Flotation Supplemental Specifications: Refer to any that may describe
external liquid depth, external fluid specific gravity, minimum internal
liquid level, and any other information necessary for design.
PIP VESTA002, Section 3.2.F, makes the design criteria here a matter
of agreement between purchaser and manufacturer.
Applied Supplemental Load Specification: Refer to supplemental
specifications that provide concentrated loads applied to the shell, such
as openings or appurtenances from attached equipment, valves, or
piping, or reactions from stairs and platforms for determination of
strength and stiffness issues by the manufacturer. If this information is
not provided, the requirements of PIP VESTA002, Section 1.5.F.5, still
apply.
8. Seismic Design Data
Seismic Design? (Yes/No): Indicate whether design for earthquakes is
required. The purchaser may specify API 650, Appendix E, or an
alternate criterion.
API 650 Appendix E: Mark the box provided if API 650 shall be used
for seismic design.
Shell-to-Bottom Weld Type*: See API 650, Figure 3-3A (inside and
outside corner fillets), Figure 3-3C (inside and outside partial
penetration corner welds with fillet weld reinforcement), and
Section J.3.2.4 (full penetration butt weld to flanged flat bottom).
Corner Weld Inspection Method*: Choose among the options listed in
accordance with API 650, Section 5.2.4.
11. Open Top and Fixed Roof Data (see page 5 of the Data Sheet for Floating
Roofs)
Open Top?* (Yes/No) Specify Yes if tank has no roof or has an
external floating roof. Specify No for all other tanks.
Note: The remaining entries apply to fixed roofs ONLY:
Fixed Roof Type*: Enter description such as supported cone with
internal structure, supported cone with external structure, structurally
supported aluminum geodesic dome, self-supporting cone, self-
supporting dome, self-supporting umbrella, and flanged only flat top.
Roof Support Columns*: Complete for supported roofs only. Specify
pipe or structural shape. If structural shape is specified, indicate the
kind (e.g., wide flange, back-to-back channel, etc.).
Cone Slope*: Specify as rise and run in inches per foot. For examples,
see API 650, Sections 3.10 and 3.10.5.
Dome or Umbrella Radius*: See API 650, Section 3.10.6, for self-
supporting approximate spherical radius of roof.
Weld Joints*: Describe the type of roof plate weld joint. May be lap
joint, butt joint, or some combination thereof. By default, lap joint shall
be chosen.
Note: API 650, Appendix F, Section F.7 roofs shall conform to
API Standard 620. When radial lap joints are included in the
compression ring region, see API Standard 620, Section 3.12.2,
Note 17, for an important design issue.
Seal Weld Underside of Lap Joints? (Yes/No): Indicate if required.
May be required for internally coated roof plates or to prevent crevice
corrosion.
Gastight? (Yes/No): Indicate whether the vapor space must be gastight.
For examples, see API 650, Section 5.3.7.
Joint Efficiency*: Use only for API 650, Appendix F, Section F.7 roofs.
See API Standard 620, Table 3-2.
Thickness*: Provide nominal thickness (in inches), including any
corrosion allowance of roof plates.
Live Load*: Indicate uniformly distributed roof live loads from
operational, maintenance, personnel, scaffolding, equipment loads,
snow, ice, etc. API 650, Section 3.10.2.1, requires a minimum value of
25 PSF. For instructions on combining with ice and snow loads, see
PIP VESTA002, Section 3.2.D.
Applied Supplemental Loads Specification*: Indicate supplementary
specifications for both dead and live roof loads that are concentrated or
have local distributions (e.g., the personnel loads of API 650,
Sections 3.8.6.2 and H.4.2.5). Specify any reactions from platforms or
walking surfaces as well as loads applied by equipment, valves, and
piping.
Column Lateral Load: Purchaser may optionally specify lateral loads
imposed upon roof-supporting columns in accordance with
API 650,Section 3.10.2.8.
Frangible Roof-to-Shell Joint? (Yes/No): Indicate if required. See
API 650, Sections 3.10.2.5.1 and 3.10.2.5.3. The frangibility of tanks
less than 50 feet in diameter may require additional design
considerations beyond those required by API 650.
Seal Weld Roof Plates to Top Angle on the Inside? (Yes/No): When
Yes is selected, the shell-to-roof-joint shall be seal-welded on the
inside. For certain designs, this may adversely effect frangibility, as
indicated in API 650, Section F.2.2.2.
Roof-to-Shell Detail*: See API 650, Figures 3-3A, F-2, and
Section J.3.5, and API Standard 620, Figure 3-6.
Radial Projection of Horizontal Component to Top Angle*: Specify
inward or outward projection.
12. Required Bottom Data
Thickness*: Enter nominal thickness, including corrosion allowance.
Style*: A = flat, B = cone up to center, C = cone down to center,
D = side to side, E = cone down to off-center sump
Slope*: Enter in inches/foot. For Style E above, the slope specified is
the maximum slope.
Weld Joint Type*: 1 = single-welded full-fillet lap joint, 2 = single-
welded butt with non-removable backing strip, 3 = double-welded butt
without backing strip, 4 = double welded, full-fillet lap joints, 5 = other
to be detailed on Data Sheet Remarks Line 23
Provide Drip Flange (Yes/No): Indicate if required. If Yes, a drip
flange shall be provided per PIP VESTA002, Section 3.4.B. Unless the
following Alternate Specification is provided, the default drip flange
shall be provided.
Alternate Specification: Refer to an acceptable drip ring design
specification if the purchaser requires a drip ring but declines the
default design of PIP VESTA002, Section 3.4.B.
Annular Ring* (Yes/No): Indicate if required. The purchaser may
stipulate this type of detail even if API 650 does not require such for
19. Release Prevention Barrier (See API 650, Appendix I, Section I.1.1, Note, for
definition.)
Release Prevention Barrier? (Yes/No): Indicate whether a release
prevention barrier shall be provided (e.g., vault floors, double bottoms,
and impermeable membranes).
Per Specification*: Describe requirements and responsible parties.
20. Tank Measurement System
Required? (Yes/No): Indicate whether a tank measurement system shall
be provided (e.g., float gauge, differential pressure level indicator,
radar, and level gauge).
Remote Capability Required? (Yes/No): Indicate whether level
measurements are required to be relayed to remote control stations.
By*: Designate the provider of the measurement system.
Per Specification*: Refer to supplemental specification.
21. Tank Weights and Lifting Requirements
Full of Water*: Indicate weight filled with water to design liquid level
(in pounds).
Empty*: Indicate weight when empty (in pounds). For specification of
lift lugs, see Data Sheet, Line 28. For tanks that are to be lifted, rigging
and handling instructions and temporary bracing may be required.
Provide reference to a supplemental specification as required.
Shipping: Specify weight for API 650 Appendix J tanks only.
Brace/Lift Specification*: Refer to any supplemental bracing/lifting
specifications.
22. References: Include relevant PIP Practices.
23. Remarks: Use this as a catch all for issues not adequately covered elsewhere.
Specifically, include all weld assembly sequences of PIP VESTA002, Section
1.5.C.4, that are required by purchaser. In addition, include any alternate shell
opening designs specified by purchaser in accordance with API 650, Section
3.7.1.8, with reference to the alternate criteria (e.g., API Standard 620).
Table 1 Materials of Construction*
List material specifications (e.g., CSA G40.21M-260W, ASTM A573-65,
ISO 630 Gr E355-C, etc.).
Apply corrosion allowance to each component. See PIP VEDTA002, Section 3.3.2.
For internals, the corrosion allowance shall be applied to each exposed surface
unless otherwise specified. Show units of measure.
Table 2 Bolts and Anchors
Complete all bolting and anchorage information (see API 650, Sections 2.7, 3.11.3,
E.6.2, F.7.4, and J.3.9, and PIP VESTA002, Sections 2.7.A and 3.3.1.B), including
head and nut shape and material specifications. Show units of measure for the
corrosion allowance and see PIP VESTA002, Section 3.3.2. Corrosion allowance
may be marked NA for galvanized, special corrosion resistant coated, or stainless
steel anchor bolts.
Table 3 Nozzle and Manhole Schedule* (for Fixed Roof, Shell, and
Bottom):
Include nozzles, e.g., both blanked and piped-to connections, equipment and
instrument attachment and access openings, sumps, inspection ports, and manholes
in the fixed roof, shell, jacket, and bottom.
The description of and examples for the information that may be specified in Table 3
is as follows:
Entry Field Representative
Comments Example
Mark Purchasers mark or designation Nozzle A-1 in shell
Service Stated service or purpose Product Out
Size, NPS, or Dia. (Inches) Conventional size description of NPS 24
pipe and tube
Neck Sch or Wall Thick. Pipe schedule or wall thickness Sch 40S
(Inches)
Reinf. Plate Dimensions Circular, Diamond, etc. 49.5" OD X .188"
(Inches)
Full Pen. On Open. (Y/N) See PIP VESTA002, Yes
Section 3.7.C
Flange Type Fabricated, S.O., WN, LJ, etc. ASME B16.5 Lap Joint
Flange Class or Thick. ASME, ANSI, API 650 Table Cl 150
(Inches)
Gasket Bearing Surf. Dimen. Dimension and finish of bearing 27.25" OD, 125-250 Ra
and Finish surface in contact with gasket -In
Gasket Thick. and Dimen. .125" X 24" ID X
(Inches) 28.25 OD
Gasket Matl. and Descript. Generic, Brand, ANSI Std, etc. Filled TFE Sheet,
ASME B16.21
Proj. to FF or CL or from See paragraph below 18" FF
Datum Lines
ASME B16.47 flanges are not available in all sizes, materials, and flange types.
Refer to PIP VESTA002, Section 3.7.E.
Nozzle projections shall be measured from the outside of the shell to the face of the
shell flange (FF) and from datum line to the face of the flange for roof and floor
openings, unless otherwise specified. Shell opening elevations shall be from the
datum line to the centerline of the opening, unless otherwise specified. Roof opening
locations shall be measured radially from the centerline of the tank. Specify datum
line and elevations with orientations on the Tank Plans and Sketch of the Data
Sheet.
For fabricated flanges requiring ASME Boiler and Pressure Vessel Code, Section
VIII, Division 1, UG-34 and Appendix 2 calculations, place the m and y values
for the gasket in the Remarks section of the Data Sheet, Line 23. Clearly indicate
to which gaskets these values apply.
How Attached?*: Indicate how jackets are attached to the shell. Specify
whether welded, bolted, or otherwise attached.
Type*: Specify type of jacket selected from choices provided.
Jacket Supplemental Specifications: Refer to any supplemental
specification.
Other Heaters/Coolers?* (Yes/No): Indicate if required.
Indicate Type*: Specify type of heater/cooler. For example, internal
coils, bayonet heat exchangers, or below bottom piping
Specifications for Other Heaters/Coolers*: Provide reference to any
supplemental specifications.
Design Pressure*: Specify design pressures for jacket or
heaters/coolers, both internal pressure and partial vacuum.
Design Temperature*: Specify design temperatures for jackets and
heaters/coolers.
26. Mixer/Agitator
Quantity: Indicate number required.
Size*
Per Specification*: Provide reference to supplemental specification.
27. Insulation Data
Required? (Yes/No): Indicate whether insulation is required.
Thickness*: Indicate thickness of insulation in inches.
Note: If not uniform for entire tank shell and roof, defer to
supplemental insulation specification.
Material*: Designate material and density of insulation.
Per Specifications*: Provide references to insulation and insulation
support specifications (e.g., PIP INST1000).
Responsibility for Insulation and Installation*: Indicate purchaser,
manufacturer, or others.
28. Structural Attachments
Lift Lugs for Maintenance or Installation?* (Yes/No): Indicate if
required.
Description*: Specify type of lifting lugs.
Shell Anchorage?* (Yes/No):Indicate if anchor attachments to the shell
are required.
Type*: Specify type of shell anchorage (e.g., chairs, lugs, sleeves,
rings, straps, etc.).
* If box is blank, manufacturer shall determine and submit as per PIP VESTA002.
GENERAL
1. Manufacturer* ____________________________________________ Contract No.* _________________________________________
Address* _______________________________________________________________________________________________________
Mfg. Serial No.* _____________________ Year Built* ____________ Edition & Addendum to API 650* ________________________
2. Purchaser _____________________________________________ P.O. No. _______________________________________________
Address _______________________________________________________________________________________________________
Tank Designation ________________________________________________________________________________________________
3. Owner/Operator _____________________________________________ Location ___________________________________________
4. *Size Limitations ________________________________________ Tank Diameter* _________________ Shell Height* ____________
Capacity: Maximum* _______________ Net Working* _______________ Criteria:* _______________________________________
5. Products Stored:
Liquid ___________________________________ Min. S.G.: _______ at ________F Max. S.G.: ________ at ________F
Vapor ___________________________________ Vapor Pressure ________ PSIA at Max. Operating Temp.
% Aromatic ______ Suppl. Spec. ________________________ H2S Service? Yes ! No ! Suppl. Spec. ______________________
Other Special Service Conditions? Yes ! No ! Suppl. Specs.____________________________________________________________
DESIGN AND TESTING
6. Applicable API Standard 650 Appendices:* A ! B ! C ! F ! G ! H ! I ! J ! M ! O ! P ! S !
7. Max. Oper. Temp. _____F Design Metal Temp.* _____F Roof Max. Oper. Temp.* _____F Design Liquid Level* ____________
Design Pressure ________ Partial Vacuum ___________ Maximum Fill Rate _______________ Maximum Emptying Rate _______________
Flotation Considerations? Yes ! No ! Flot. Suppl. Spec:* __________________ Applied Supplemental Load Spec._____________________
8. Seismic Design? Yes ! No ! API 650 Appendix E ! Alternate Seismic Criteria ________________________ Zone ________
Importance Factor ________ Zone Factor (Table E-2)* ________ Site Coefficient (Table E-3)* ________ Slosh Height ________
Roof Tie Rods @ Outer Ring?* Yes ! No ! Sliding Friction Factor* ______________
9. Wind Velocity* ________MPH Prevailing Wind Direction: From _____ To _____ Check Overturning Stability? Yes ! No !
Top Wind Girder Style* ______________________ Dimensions* ____________________ Use Top Wind Girder as Walkway? Yes ! No !
Intermediate Wind Girders?* Yes ! No ! Intermediate Wind Girder Style* _________________ Dimensions*______________________
Check Buckling in Corroded Cond.? Yes ! No !
10. Shell Design: 1-Ft Mthd?* Yes ! No ! ; Variable-Des-Pt Mthd?* Yes ! No ! Alternate !; Elastic Anal. Mthd?* Yes ! No ! Alternate !
Plate Stacking Criteria* Centerline-Stacked ? Yes ! No ! Flush-Stacked on the Inside? Yes ! No !
Plate Widths (Shell course heights) and Thicknesses (New):* Numbers below Indicate Course Number.
1. __________________ 2. __________________ 3. __________________ 4. __________________ 5. __________________
6. __________________ 7. __________________ 8. __________________ 9. __________________ 10. __________________
11. __________________ 12. _________________ 13. __________________ 14. __________________ 15. __________________
Joint Efficiency* ________% Shell-to-Bottom Weld Type* ___________________ Corner Weld Insp Mthd* __________________
11. Open Top and Fixed Roofs: (See Sheet 5 for Floating Roofs) Open Top? * Yes ! No !
Fixed Roof Type* _______________________________ Roof Support Columns* Pipe ! Or Structural Shape ! ___________________
Cone Slope* ________In./Ft. Dome or Umbrella Radius* ________Ft. Weld Joints* _______________________________________
(Lap, Butt, Other)
Seal Weld Underside of Lap-Joints? Yes ! No ! Gastight? Yes ! No ! Joint Efficiency* ________%
Thickness* ________In. Live Load* ________PSF App. Suppl. Load Spec.* _____________ Column Lateral Load _____________ Lbs.
Frangible Roof-to-Shell Joint? Yes ! No ! Seal Weld Roof Plates to Top Angle on the Inside? Yes ! No !
Roof-to-Shell Detail* __________________________________ Radial Projection of Horizontal Component of Top Angle* Inward ! Outward !
Approvals: Revisions: Title:
By: Ckd: Date:
Drawing No.: Sheet ___ of ___
PIP VEDTA003
Atmospheric Storage Tank
Data Sheet
Page 2 of 6
June 2002
* If box is blank, manufacturer shall determine and submit as per PIP VESTA002.
12. Bottom: Thickness* ________In. Style* _____________ Slope* ________In./Ft. Weld Joint Type* _________________
Provide Drip Flange? Yes ! No ! Alternate Spec. ______________________________________________________________________
Annular Ring?* Yes ! No ! Annular Ring: Minimum Radial Width* ________ In., Thickness* ________In.
13. Foundation: Furnished by*_________________________________________ Type* ________________________________
Soil Allow. Bearing Pressure* ________ Per Spec.* __________________________________ Anchors: Size* _____ Qty* _____
Foundation Design Loads: Base Shear (Lb.): Wind* ______ Seismic* ______ Overturning Moment (Ft.-Lb.): Wind* _______ Seismic* _____
Ring Forces (Lb./Ft.): Weight of Shell + Roof New* _______ Corroded* _______ Roof Live Load* _______ Internal Pressure* _______
Partial Vacuum* ________ Wind* ________ Seismic* ________
Bottom Forces (PSF): Floor Wt. New* ______ Corroded* ______ Product Wt.* ______ Water Wt.* _____ Internal Pressure* ______
Partial Vacuum* ___________ Other Foundation Loads* ________________________________________________________________
14. Hydrotest Minimum Metal Temperature* ________ Hydrotest Fill Height* ________ Waive Settlement Measurement? Yes ! No !
Test Water Quality Responsibility: Purchaser ! Manufacturer ! Supplemental Test Water Quality Spec. ________________________
Test Water Source & Disposal Tie-In Locations _________________________________________ Pneumatic Test Pressure* __________
Post-Pressure-Test Activities Required of the Manufacturer: Broom Clean ! Potable Water Rinse! Dry Interior! Other ! _____________
15. Inspection by _________________________________________ in Shop; ___________________________________________ in Field
Supplemental NDE Responsibility ______________________ Supplemental NDE Spec. ______________________________________
(Purch., Mfg., Other)
23. Remarks*:
* If box is blank, manufacturer shall determine and submit as per PIP VESTA002.
Table 1. MATERIALS of CONSTRUCTION
Component Material* C.A. Component Material* C.A.
Shell, Course __ to __ Manhole/Nozzle Necks
Shell, Course __ to __ Manhole/Nozzle Flanges
Shell, Course __ to __ Flange Covers
Roof Anchor Attachments
Bottom Submerged Piping
Annular Ring Wetted Structurals +
Reinforcing Pads Non-wetted Structurals +
* If box is blank, manufacturer shall determine and submit as per PIP VESTA002.
OTHER TANK APPURTENANCES
24. Platform, Stairway, and Railing: Galvanizing Reqd?* Yes ! No ! Stairway Style* ____________ Walk Surf. Type* ___________
(Straight or Helical)
* If box is blank, manufacturer shall determine and submit as per PIP VESTA002.
FLOATING ROOF CONFIGURATION
30. External Type: Single Deck Pontoon* ! Double Deck* ! Other ! ________________________________________________
Internal Type: Tubular Pontoon* ! Metallic Sandwich Panel* ! Composite Sandwich Panel* ! Single Deck* ! Double Deck* !
Other ! _______________________________________________________________________________________________________
31. Overflow Openings in Shell Acceptable? Yes ! No ! Shell Extension? Yes ! No ! Alarm Device Spec. ________________________
Roof Drain Check Valves Reqd? Yes ! No ! Roof Drain Isolation Valves Reqd? Yes ! No !
Freeze Protection for Roof Drains Reqd? Yes ! No !
Roof Drain Piping to External Nozzles: Mfg. Std. ! Armored Flexible Pipe ! Swivels in Rigid Pipe ! Other ! ___________________
Rim Vents? Yes ! No ! Quantity* ______ Foam Dam? Yes ! No ! Supplemental Spec. __________________________________
Minimum Deck Thickness for External Floating Roofs* ___________________________ Rolling Ladder Reqd?* Yes ! No !
32. Bulkheads Top Edges to be Liquid Tight ? Yes ! No ! No. of Fixed Roof Inspection Hatches Required:_____________
Internal Roof Drain Required? Yes ! No ! Corrosion Gauge Required? Yes ! No ! Two-Position Legs? Yes ! No !
33. Primary Seal: Shoe ! Toroidal Envelope ! Other ! __________________________________ Wax Scrapers Reqd? Yes ! No !
34. Shoe Mechanism: Mfg. Std. ! Other ! ________________________________________________
Electrically Isolate Mechanism from Shoes? Yes ! No !
35. Minimum Shoe Thickness* ____________In. Carbon Steel Shoes to be Galvanized? Yes ! No !
36. Secondary Seal? Yes ! No ! Suppl. Spec. ___________________ Weather Shield? Yes ! No ! Suppl. Spec. ____________________
37. Qty of Non-Guide Pole Gauge Wells Required __________ Qty of Sample Hatches Required ___________
Guide Pole for Gauging? Yes ! No ! Slots in Guide Pole? Yes ! No ! Datum Plates? Yes ! No ! Striking Plates? Yes ! No !
Guide Pole Emissions-Limiting Devices: Sliding Cover ! Pole Wiper ! Pole Sleeve ! Float ! Float Wiper ! Pole Cap !
38. Qty. of Roof Manholes* _______ Minimum Roof Clearances Above Floor: Operating _______In. Maintenance _______In.
39. Cable-Supported Floating Roof? Yes ! No ! Leg Sleeves ! OR Fixed Low Legs !
Removable Leg Storage Racks? Yes ! No ! Must Each Leg Be Field Adaptable? Yes ! No !
DESIGN AND TESTING
40. Design Rainfall Intensity ________In./Hr. (mm/hr) Based on a ________ Minute Duration Associated with the ____________ Storm
Design Accumulated 24-Hour Rainfall ________In. (mm) Based on the ____________ Storm
Distortion and Stability Determinations Required? Yes ! No ! Supplemental Specification __________________________________
41. Flotation Test Required for API 650 H.5.2 or H.5.3 Roofs? Yes ! No !
Landed Live Load* _______PSF Required Even When Drains are Specified*? Yes ! No ! Point Load Required? Yes ! No !
Table 5. FLOATING ROOF MATERIALS
Component Material*/Thickness* C.A./Coating* Component Material*/Thickness* C.A./Coating*
Deck Plate Datum Plate
Inner Rim Plate Tubular Pontoon
Outer Rim Plate Pontoon Bulkhead
Foam Dam Submerged Pipe
Sandwich Panel Face Guide Pole
Plate
Sandwich Panel Core Secondary Seal
Gauge Well Secondary Seal Fabric
Drain Sumps Wiper Tip
Opening Sleeves Wax Scraper
Floating Suction Lines Weather Seal
Primary Fabric Seal Envelope Fabric
Foam Log Core Shoe Mechanisms
Landing Legs Primary Seal Shoe
Landing Leg Bottom Pads Removable Covers
Manhole Necks Rolling Ladder
Vents Inlet Diffusers
* If box is blank, manufacturer shall determine and submit as per PIP VESTA002.
Tank Plan and Sketches:
Notes: