Formulas:
1) H= Total head required by specification, m
2) Ps= Suction pressure gage reading, kPa
3) Pd= Discharge pressure gage reading, kPa
4) Vs= Velocity in suction, m/s
5) Vd= Velocity in discharge, m/s
6) Z= Distance in m, center of gage above or below datum. Z is negative when gage is
below datum. Zs and Zd refer to suction and discharge gage respectively.
7) W= Specific weight of water, kg/liter
8) hsr: Head loss of suction reducer 1400 x 1200, k=0.15 , h = 0.15x (Vs 2/ 19.6)
9) hdr :Head loss of discharge reducer 1000 x 1200, k=0.15 , h = 0.15x (Vd 2/ 19.6)
10) hse: Head loss of pump entrance at suction side, k=1, h=1x (Vs 2/ 19.6)
11) hde :Head loss of pump entrance at discharge side, k=1, h=1x (Vd 2/ 19.6)
Total head:
H= I hd I + I hs I
Water power ( Hydraulic Kilowat):
WKW= 9.81xQxHxW
Overall efficiency is the ratio of the power delivered by the pump to the power supplied to the
input side of driver
Eo = (WKW/EKW)
Finally:
KW/WHP=0.736/Eo
Test Record of Main pump A: Date:
Pump Manufacturer:
Motor manufacturer
Date of Test:
Tested by:
Witnessed by:
-
-
-
Test Record of Main pump B: Date:
Pump Manufacturer:
Motor manufacturer
Date of Test:
Tested by:
Witnessed by:
-
-
-
-
-
Test Record of Main pump C: Date:
Pump Manufacturer:
Motor manufacturer
Date of Test:
Tested by:
Witnessed by:
-
-
-
-
-
Test Record of Main pump D: Date:
Pump Manufacturer:
Motor manufacturer
Date of Test:
Tested by:
Witnessed by:
-
-
-
-
-
Test Record of Main pump E: Date:
Pump Manufacturer:
Motor manufacturer
Date of Test:
Tested by:
Witnessed by:
-
-
-
-
-
Test Record of Main pump F: Date:
Pump Manufacturer:
Motor manufacturer
Date of Test:
Tested by:
Witnessed by:
-
-
-
-
-