Sei sulla pagina 1di 1

a.

Define the conduction interval for each switching semiconductor


Thyristo Conduction Conduction
r begins ends
TA 0 90
TA 60 180
TB 180 270
TB 210 300
TC 270 360
TC 300 30 (60)

e. Briefly explain the operation of the converter based on the sketched waveforms.

The converter is a basically 3 units of 1 full-wave controlled rectifier, which each phase is
controlled based on the timing given on TA, TB and TC. As phases are shifted to 0, 120
and 240, timing is given to maximize output of the rectifier. In the lab, 0 is set to variance
value which is corresponding to a defined voltage value. Result of the 0 changes are akin to
give control over DC motor speed.

Given that power given is 3 times of the 1 power source, it can be used to supply DC in
case of high demand.