Error Codes Blend Error Codes MDE-4039B

Code Description Code Description


20 Pulser Fail 4307 Blends Not Programmed Encore 300 Programming
24 Conversion Factor Changed/ 4308 No Blend Table Quick Reference Card
Not Programmed 4311 Low Product Low Flow February 2004
25 Two-Wire/Standalone Mode 4312 Hi Product Low Flow
Changed 4313 Low Product No Flow
26 Meter Not Calibrated 4314 Hi Product No Flow
27 Side 1 Two-Wire ID Changed 4315 Hi Product Contaminated by Lo Software Versions
28 Side 2 Two-Wire ID Changed 4316 Lo Product Contaminated by Hi
For detail on software versions, see MDE-3804 Encore and Eclipse Service
29 Pump Time-Out Error 4329 Leaky Valve
Manual. Power-up and Command Code 8 display the current software version.
30 VaporVac Fail Both Sides or

31
Vapor Sense 5
Totals Data Error Single-Hose MPD PIN Code Entry
32 Pulser Count Error Level 1- Press F1, enter 4-digit ID (default 2222) then press ENTER.
Code Description Level 2- From Level 1, enter any Level 2 Command Code (10-12), enter 4-digit
33 VaporVac Fail One Side or
4350 Valve Control Option Not ID (default 1503) then press ENTER.
Push-To-Stop Button Activated
Programmed (see CC17) Level 3- From Level 2, enter any Level 3 Command Code (13-17), enter 4-digit
35 Configuration Data Error 4351 Valve Leaks - Grade 1 ID (default 1309) then press ENTER.
36 Unit Type Configuration Code
4352 Valve Leaks - Grade 2
Changed
4353 Valve Leaks - Grade 3 Press F1 to exit any command code.
37 PIN Code 1 Changed 4355 Valve Leaks - Grade 1 & 2 Press F2 to return to normal operation.
38 PIN Code 2 Changed
4356 Valve Leaks - Grade 1 & 3
39 Cash/Credit Option Changed
40 Master Reset Jumper in Place
4358 Valve Leaks - Grade 2 & 3 From Level 2:
41 Side Exists Option Changed Command Code 10:
44 Pump Handle Up at Power Up System Configuration
45 Preset Overrun (minor) Press ENTER after making selections.
46 Preset Overrun (major) Enter 10.
Enter Function #.
* Default Enter Configuration #.

Function Code 1 (For non-blenders only):


Unit Type
Self configures default value.
1 = 1 product
2 = 2 product
3 = 3 product

Function Code 2: Money Decimal Point


1 = xxxxx
2 = xxxx.x
3 = xxx.xx *
4 = xxx.xxx

Function Code 3:
Calculation PPU Decimal Point
(Required in U.S. per Weights & Measures)
1 = xxxx
2 = xxx.x
3 = xx.xx
4 = x.xxx *

Function Code 4:
Displayed PPU Decimal Point
Self configures default value.
1 = xxxx
2 = xxx.x
3 = xx.xx
Eclipse, Encore, CRIND, and
4 = x.xxx
VaporVac are registered trademarks
of Gilbarco Inc. Function Code 5: STP Prestart
0 = Off *
Call Gilbarco Technical Support at: 1-800-743-7501 1 = On
2004 Gilbarco Inc. 7300 W. Friendly Ave., P.O. Box 22087
Greensboro, NC 27420 Phone # 336-547-5000 http://www.gilbarco.com
1 = Enabled Command Code 16:
Function Code 6: Beeper Option Function Code 16: Beeper Time-out Command Code 12: Blend Ratios
0 = Off 0 = Off * Pump Program Press ENTER after making
1 = On * 1 = 5 seconds Enter 12 selections.
2 = 15 seconds Enter Side # Enter 16
Function Code 8: 3 = 30 seconds 1 = Side 1 Enter Side #
Two-Wire Display Blank Option: 4 = 45 seconds 2 = Side 2 1 = Side 1
0 = Off * 5 = 60 seconds Enter Function Code (1-4) 2 = Side 2
1 = On 6 = 75 seconds Enter Configuration Code 3 = Both Sides
7 = 90 seconds Enter Grade #
Function Code 9: 8 = 120 seconds Function Code 1: Enter low blend percentage
5 or 6 Digit Cash Display 9 = 240 seconds Two-Wire Pump ID Repeat for remaining grades
0 = 5 Digit Money * 1-16 = (7* for Side 1; 11* for Side 2)
1 = 6 Digit Money Function Code 17: Command Code 17
Push to Stop Control Function Code 2: Conversion Factor and Master Reset
Function Code 10: 0 = Stop controls one side * Cash/Credit At Pump Select function code.
Decimal/Comma Mode 1 = Stop controls two sides 0 = No (CRIND) *
0 = Comma Off* 1 = Yes (console cash/credit price Function Code 1:
1 = Comma On Function Code 18: levels) Conversion Factor
Zero Previous Transaction After Pump (ECAL switch must be ON when
Function Code 11: Handle Operation Function Code 3: conversion factor is entered)
Preselect Time-Out Side Exists
0 = Zero after lamp test * 0 = No conversion factor *
0 = None 0 = Does not exist
1 = Zero before lamp test 1 = U.S. Gallons
1 = 5 seconds 1 = Exists * 2 = Imperial Gallons
2 = 15 seconds * Function Code 19: Lamp Test 3 = Liters
3 = 30 seconds 1 = 1 second Function Code 4:
4 = 45 seconds 2 = 2 second PPU Options Function Code 2:
5 = 60 seconds 3 = 3 second * 0 = Level 1 price bar displays level Master Reset
6 = 75 seconds 4 = 4 second sent by console or CRIND card 0 = No Master Reset
7 = 90 seconds 5 = 5 second reader.* 1 = Master Reset
8 = 120 seconds 6 = 6 second 1 = Normal
7 = 7 second 2 = Level 2 price bar, level 1 prices
Function Code 12:
Pump Time-Out
8 = 8 second and level 1/level 2 prices
3 = Level 2 price bar displays level
Meter Calibration
9 = 9 second
0 = None * sent by console or CRIND Refer to MDE-3804 Service Manual
1 = 5 seconds Function Code 20: and MDE-4281 Calibration Quick
2 = 15 seconds Programmable Pump Preset Value Reference Card for details.
3 = 30 seconds
4 = 45 seconds
0 = Value X 1 (enter fractions) From Level 3: Note: Before calibrating meter(s),
Conversion Factor must be entered
1 = Value X 10 (enter whole units) Command Code 13:
5 = 60 seconds first in Command Code 17
6 = 75 seconds Pin Code Change
Function Code 21:
7 = 90 seconds Press ENTER after selections.
PPU Blinking Option
8 = 120 seconds Enter 13
0 = No PPU blinking*
Enter Level # 1, 2 or 3
1 = PPU Blinking
Function Code 13 (Ultra-Hi only) Enter new PIN Code
Slowdown Function Code 22: Unit returns to Command Input Mode.
0 = .070 gallons (.264 liters) Volume Decimal Point
1 = .120 gallons (.454 liters) * Command Code 15:
0 = XXX.XXX *
2 = .170 gallons (.643 liters) Function Code 1:
1 = XXXX.XX (export only)
3 = .220 gallons (.833 liters) Preselect Time-Out
4 = .270 gallons (1.02 liters) Function Code 23: 0 - 999 seconds
5 = .320 gallons (1.21 liters) Program STP Control
6 = .370 gallons (1.40 liters) 0 = Off * Function Code 2:
7 = .420 gallons (1.59 liters) 1 = On Pump Time Out
8 = .470 gallons (1.78 liters) 0 - 999 seconds
9 = .520 gallons (1.97 liters) Function Code 24:
Hose Pressurization
Function Code 3:
Function Code 14: 0 = Off *
Beeper Time Out
G6 PUsh to Start 1 = 2 Hr.
0 - 999 seconds
0 = Off* 2 = 1/2 Hr.
1 = On
Function Code 4:
Function Code 15: Slowdown Valve
* Default 0 - 0.999 gallons
Zero PPU Pricing Option Enable Must be programmed to 1 in New Jersey.
0 = Disabled * * Default