Position Qty. Description
1 CR 5-29 A-FGJ-A-E-HQQE

Note! Product picture may differ from actual product


Product No.: 96513392

Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line)
enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all
other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling
and easy service and access. Power transmission is via a split coupling. Pipework connection is via
combined DIN-ANSI-JIS flanges.
The pump is fitted with a 3-phase, fan-cooled asynchronous motor.

Further product details


The product carries the Grundfos Blueflux label. It represents the best from Grundfos within
energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or
exceed legislative requirements such as the EuP IE3 grade.

Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic
electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical
field around the products ensures deposition of paint particles as a thin, well-controlled layer on the
surface. An integral part of the process is a pretreatment. The entire process consists of these
elements:
1) Alkaline-based cleaning.
2) Zinc phosphating.
3) Cathodic electro-deposition.
4) Curing to a dry film thickness 18-22 my m.
The colour code for the finished product is NCS 9000/RAL 9005.

Pump
A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor
stool by means of two coupling guards.

The pump head, pump head cover and flange for motor mounting is made in one piece. The pump
head has a combined 1/2" priming plug and air vent screw.

1/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -

The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is
assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is
suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible
wear from a dynamic O-ring between pump shaft and shaft seal.
Primary seal:
- Rotating seal ring material: Silicon carbide (SiC)
- Stationary seat material: Silicon carbide (SiC)
This material pairing is used where higher corrosion resistance is required. The high hardness of
this material pairing offers good resistance against abrasive particles.
Secondary seal material: EPDM (ethylene-propylene rubber)
EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils.

The shaft seal is screwed into the pump head.

The chambers and impellers are made of stainless steel sheet. The chambers are provided with a
PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface,
and the shape of the blades ensure a high efficiency.

The base is made of cast iron. The flanges and base are cast in one piece. The discharge side of
the base has a combined drain plug and bypass valve. The pump is secured to the foundation by
four bolts through the base plate.

Motor
The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN
standards. The motor is flange-mounted with tapped-hole flange (FT).
Motor mounting designation in accordance with IEC 60034-7: IM B 14 (Code I) / IM 3601 (Code II).
Electrical tolerances comply with IEC 60034.

The motor efficiency is classified as IE3 in accordance with IEC 60034-30.

The motor has thermistors (PTC sensors) in the windings in accordance with DIN 44081/DIN 44082.
The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled
conditions.

2/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -

Thermal switches must be connected to an external control circuit in a way which ensures that the automatic
reset cannot cause accidents. The motors must be connected to a motor-protective circuit breaker according to
local regulations.

The motor can be connected to a variable speed drive for adjustment of pump performance to any
duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in
Win-/WebCAPS.

Technical data

Liquid:
Pumped liquid: Water
Liquid temperature range: 253 .. 393 K
Liquid temp: 293 K
Density: 998.2 kg/m

Technical:
Speed for pump data: 2917 rpm
Rated flow: 5.8 m/h
Rated head: 150 m
Shaft seal: HQQE
Approvals on nameplate: CE,TR
Curve tolerance: ISO 9906:1999 Annex A

Materials:
Pump housing: Cast iron
EN-JL1030
ASTM A48-30 B
Impeller: Stainless steel
DIN W.-Nr. 1.4301
AISI 304

Installation:
Maximum ambient temperature: 333 K
Max pressure at stated temp: 25 bar / 120 C
25 bar / -20 C
Flange standard: DIN
Pipe connection: DN 25 / DN 32
Pressure stage: PN 16 / PN 25
Flange size for motor: FT130

Electrical data:
Motor type: 112MC
IE Efficiency class: IE3
Number of poles: 2
Rated power - P2: 4 kW
Power (P2) required by pump: 4 kW
4 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-415 D V
Rated current: 7.9 A
Starting current: 1000-1110 %
Cos phi - power factor: 0,87-0,87
Rated speed: 2920-2940 rpm
Efficiency: IE3 88,1%
Motor efficiency at full load: 88,1-88,1 %
Motor efficiency at 3/4 load: 88,6-88,2 %

3/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
Position Qty. Description
Motor efficiency at 1/2 load: 85,2-88,1 %
Enclosure class (IEC 34-5): 55 (Protect. water jets/dust)
Insulation class (IEC 85): F

Others:
Label: Grundfos Blueflux
Minimum efficiency index, MEI : 0.57
Net weight: 65.9 kg
Gross weight: 86.5 kg
Shipping volume: 0.2 m3

4/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
96513392 CR 5-29 50 Hz
H CR 5-29, 3*400 V, 50Hz eta
[m] [%]
Pumped liquid = Water
Liquid temperature = 293 K
Density = 998.2 kg/m

220

200 100

180 90

160 80

140 70

120 60

100 50

80 40

60 30

40 20

20 10

0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 Q [m/h]
P NPSH
[kW] [m]

5 10
P1

4 8
P2

3 6

2 4

1 2

0 0

5/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
Description Value H CR 5-29, 3*400 V, 50Hz eta
[m] [%]
Pumped liquid = Water
Product name: CR 5-29 A-FGJ-A-E-HQQE 220
Liquid temperature = 293 K
Product No: 96513392 200 Density = 998.2 kg/m 100
EAN number: 5700396639567 180 90
160 80
Technical: 140 70
Speed for pump data: 2917 rpm 120 60
Rated flow: 5.8 m/h 100 50
Rated head: 150 m
80 40
Head max: 198 m
60 30
Impellers: 29
40 20
Shaft seal: HQQE
20 10
Approvals on nameplate: CE,TR
Curve tolerance: ISO 9906:1999 Annex A 0 0
0 1 2 3 4 5 6 7 8 Q [m/h]
Pump type: CR 5 P NPSH
Stages: 29 [kW] P1 [m]
Pump version: A 4 10
P2
Model: A
2 5
Materials:
Pump housing: Cast iron
0 0
EN-JL1030
ASTM A48-30 B 140

4 x 13.5
Impeller: Stainless steel 100
89

DIN W.-Nr. 1.4301


AISI 304

35
Material code: A

180
220
19 x 24.5
Code for rubber: E

Installation:
20

Maximum ambient temperature: 333 K


Max pressure at stated temp: 25 bar / 120 C
25 bar / -20 C
220

100
141
250
134

Flange standard: DIN


G 1/2

Connect code: FGJ


Pipe connection: DN 25 / DN 32
75
372 1034

Pressure stage: PN 16 / PN 25
Flange size for motor: FT130
THERMISTORS PTC ACCORDING TO DIN 44082
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY

Liquid: IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

Pumped liquid: Water


Liquid temperature range: 253 .. 393 K
Liquid temp: 293 K
Density: 998.2 kg/m
+T

+T
L3

L3
L2

L2

Electrical data:
+T

+T
L1

L1

Motor type: 112MC


+T

+T

IE Efficiency class: IE3


TO AMPLIFIER

TO AMPLIFIER

Number of poles: 2
RELAY

RELAY

Rated power - P2: 4 kW


Power (P2) required by pump: 4 kW
4 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-415 D V
Rated current: 7.9 A
Starting current: 1000-1110 %
Cos phi - power factor: 0,87-0,87
Rated speed: 2920-2940 rpm
Efficiency: IE3 88,1%
Motor efficiency at full load: 88,1-88,1 %
Motor efficiency at 3/4 load: 88,6-88,2 %
Motor efficiency at 1/2 load: 85,2-88,1 %
Enclosure class (IEC 34-5): 55 (Protect. water jets/dust)
Insulation class (IEC 85): F
Motor protec: PTC

6/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
Description Value
Motor No: 85U15413

Others:
Label: Grundfos Blueflux
Minimum efficiency index, MEI : 0.57
Net weight: 65.9 kg
Gross weight: 86.5 kg
Shipping volume: 0.2 m3

7/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
96513392 CR 5-29 50 Hz
134

220
372
1034

G 1/2 19 x 24.5
100
140
89
75

20

100 35 4 x 13.5
141 180
250 220

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.

8/9
Printed from Grundfos CAPS [2013.03.059]
Company name: Lenntech BV - lenntech.com
Created by: info@lenntech.com
Phone: +31 15 2610900
Fax: +31 15 2616289
Date: -
96513392 CR 5-29 50 Hz

+T +T +T

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
TO AMPLIFIER
RELAY
L1 L2 L3

THERMISTORS PTC ACCORDING TO DIN 44082

+T +T +T

TO AMPLIFIER
RELAY
L1 L2 L3

Note! All units are in [mm] unless others are stated.

9/9
Printed from Grundfos CAPS [2013.03.059]
Disclaimer: The information about the Grundfos pump in this document may be outdated.
Data may be subject to alterations without further notice.
Please contact us to verify the data above is still accurate/up-to-date.

All information is copyright Grundfos.


info@lenntech.com
www.lenntech.com
tel. +31-15-261.09.00
fax. +31-15-261.62.89

Potrebbero piacerti anche