SCHEDULE FOR THE SPECIFICATION REQUIREMENT FOR DESIGNED CONCRETE FOR USE PAGE

ON CONTRACT 1 OF 3
CONTRACT TITLE: Mule International Hotel
CONTRACT PERIOD:
REFERENCE REQUIREMENT SCHEDULE REMARK
BS 8500-1
4.3.2 a The concrete below shall be supplied as designed concretes in accordance with this
specification and the relevant clauses of BS 8500-2
Concrete reference Found. Slab Cols. Beams (D)
4.3.2 b Compressive strength C25/30 C25/30 C32/40 C25/30 (D) See
detailed remark
4.3.2 c Limiting values of composition: (D) See
Maximum w/c ratio 0.65 0.65 0.55 0.65 detailed remark
Minimum cement content, kg/m3 260 260 300 260
4.3.2. d Cement combination types CEM 1, CEM 1, CEM 1, CEM 1, (D) See
(delete those not permitted) SRPC, SRPC, SRPC, SRPC, detailed remark
IIA, IIB, IIA, IIB, IIA, IIB, IIA, IIB,
111A, 111A, 111A, 111A,
IIIB, IVB IIIB, IVB IIIB, IVB IIIB, IVB
4.3.2 e Maximum aggregate size 20 20 20 20 (D) See
detailed remark
4.3.2. f Chloride class (D) See
Prestressed or heat cured RC Cl 0, 10 Cl 0, 10 Cl 0, 10 Cl 0, 10 detailed remark
Reinforced Concrete Cl 0, 40 Cl 0, 40 Cl 0, 40 Cl 0, 40
Unreinforced with embedded steel Cl 1, 0 Cl 1, 0 Cl 1, 0 Cl 1, 0
(delete those not permitted)
4.3.2. g For light weight and heavy weight 2400 - 2400 - 2400 - 2400 (D) See
concrete target density 2500 2500 2500 2500 detailed remark
4.3.2 i Consistence (delete the class not S1, S2, S1, S2, S1, S2, S1, S2, (D) (C) See
required) S3, S4 S3, S4 S3, S4 S3, S4 detailed remark
4.3.2 Note1 - - - - -
4.3.2 Note2 Accredited third party product Yes Yes Yes Yes (D) See
conformity certification detailed remark
4.3.2 Note3
4.3.3 a Special types or classes of aggregate No No No No
4.3.3 b The use of coarse recycled No No No No
aggregate
4.3.3 c Restrictions on the use of certain Yes Yes Yes Yes (D) See
aggregates detailed remark
4.3.3 d Generic type and dosage of fibers No No No No
SCHEDULE FOR THE SPECIFICATION REQUIREMENT FOR DESIGNED CONCRETE FOR USE PAGE
ON CONTRACT 2 OF 3
CONTRACT TITLE: Mule International Hotel
CONTRACT PERIOD:
REFERENCE REQUIREMENT SCHEDULE REMARK
4.3.3 e Characteristics required to resist No No No No
freeze-thaw attack
4.3.3 f Temperature of the fresh concrete No No No No
4.3.3 g Strength development No No No No
4.3.3 h Heat development during hydration No No No No
4.3.3 i Retarded stiffening No No No No
4.3.3 j Resistance to water penetration No No No No
4.3.3 k Resistance to abrasion No No No No
4.3.3 l Tensile splitting strength No No No No
4.3.3 m Other technical requirements No Yes Yes Yes (D) See
detailed remark
4.3.3 n Concerning effects, Yes Yes Yes Yes
together with the tests to be applied
and the acceptability criteria
(D) Indicates the fields that are to be specified by the designer
(C) indicates the fields that are to be specified by the contractor
DETAILED REMARKS FOR THE SCHEDULE FOR THE SPECIFICATION REQUIREMENT FOR PAGE
DESIGNED CONCRETE FOR USE ON CONTRACT 1 OF 3
CONTRACT TITLE: Mule International Hotel
CONTRACT PERIOD:
REMARK REQUIREMENT DETAILED INFORMATION
4.3.2 b Compressive This item specifies the characteristic strength of the structural member, which will have
strength to be verified by cube tests during the construction process and a trial mix prior to
construction. A margin of defectives of 2.5% and 5% has been specified for trial mixes
and produced concrete respectively.
4.3.2 c Limiting values of These limiting values for the concrete mix MUST be respected and the contractor has to
composition produce a trial mix design prior to producing the required volumes of concrete. The
contractor should then fill the form attached on appendix 1 and submit the same to the
consultant to approve the mix design before commencement of production.
4.3.2. d Cement The types of cement that can be used have been specified. The contractor should obtain
combination a certificate attesting the strength class and the type of cement being used.
types
4.3.2 e Maximum The maximum size of aggregate to be used should be as specified. The aggregate should
aggregate size be saturated and surface dry prior to usage.
4.3.2. f Chloride class The chloride class of the cement being used should be as specified and the contractor
should present a certificate of the same prior to production of concrete.
4.3.2. g For light weight The target density of the produced concrete should be verified and should be within the
and heavy weight limits specified. The contractor should verify this during the trial mix design. When using
concrete target a concrete mixer, it is mandatory to measure all constituents by weight and for the
density mixer to mix the constituents for at least 2.5 minutes.
4.3.2 i Consistence The consistence (workability) of the concrete mix should be as specified. Slump should
be measured every 10m3 for columns, every 20m3 for beams, slabs and every 50m3 for
mass foundations as per BS 1881: Part 102 or BS EN 12350 2 and the attached
certificate on appendix 2 filled each time and submitted to consultant.
Slump class Slump range (mm) Max. allowable deviation on range limit (mm)
Spot sample Composite sample
S1 10 - 40 -10, +30 -10, +20
S2 50 - 90 -20, +30 -10, +20
S3 100 - 150 -20, +30 -10, +20
S4 160 - 210 -20, +30 -10, +20
4.3.2 Accredited third A sample of 6 cubes should be tested every 10m3 for columns, every 20m3 for beams,
Note2 party product slabs and every 50m3 for mass foundations. 3 cubes tested at 7 days and 3 at 28 days.
conformity The cubes should be produced and cured as per BS 1881: Part 111 or BS EN 12390 2.
certification The attached form should be filled by contractor every time a cube is produced and
cured, appendix 3 and 4 respectively. It is the characteristic strength that is crucial and
not the average. It is left to the contractor to decide on the number of samples (6 being
the minimum) to control the standard deviation of test results. Test results should be
attested by a third party.
4.3.3 c Restrictions on Fine aggregates should have maximum clay, silt and dust content of 3% of weight of
the use of certain sand. If standard testing mechanism as per BS 812: Part 1 is not available site
aggregates verification methods can be used. The contractor should also specify how much fine
aggregate by % of volume is passing through a 600m sieve during trial mix and every
time a new batch is used.
4.3.3 m Finishing of All concrete surfaces are to be finished as a smooth textured surface on to which
concrete surface gypsum plaster can be directly applied without having to chisel the concrete surface and
apply a mortar plaster.
APPENDIX 2 CERTIFICATION OF SLUMP TEST
Testing carried out in accordance with: (please indicate)
[ ] BS 1881 : Part 102 [ ] BS EN 12350 2

Essential Information

Date of test
Sampling: Time Place
Sampling method: [ ] General - BS 1881: Part 101
Or alternative [ ] BS 1881: Part 102, Clause 4.2
Sample identity number
Sampling certificate available (copy attached)
Slump: Time of test Place
Time from sampling to beginning of test
Form of slump: [ ] true [ ] shear [ ] collapse
Measured true slump
Name of tester

Additional Information

Name of project
Part of works where concrete used
Name of supplier
Source of concrete
Time of production or delivery to site
Specification of concrete mix (e.g. strength class)

Affirmation that the test was made in accordance with BS 1881: Part 102 or BS EN 12350-2 as indicated above

Name and Signature of person responsible for test


APPENDIX 3 CERTIFICATION OF CUBE MAKING
Testing carried out in accordance with: (please indicate)
[ ] BS 1881 : Part 108 [ ] BS EN 12390 2

Essential Information

Sample identity number


Date and time of sampling
Place of sampling
Time of making the cubes
Place where cubes were made
Number of cubes made in the set
Size of cubes
Method of compaction (hand/vibration)
For hand tamping: number of strokes used
For vibration: type of equipment and duration of vibration
Identification number or codes of the cubes
Age(s) at which cubes are to be tested
Name of person making cubes

Additional Information

Name of project
Location of concrete represented by the cubes
Name of supplier and source of the concrete
Time of production
Time of delivery to site
Specification of the concrete
Measured consistence
Air content of concrete (if air-entrained)

Affirmation that the test was made in accordance with BS 1881: Part 108 or BS EN 12390-2 as indicated above

Name and Signature of person responsible for test


APPENDIX 4 CERTIFICATION OF STANDARD CURING OF TEST CUBES
Testing carried out in accordance with: (please indicate)
[ ] BS 1881 : Part 111 [ ] BS EN 12390 2

Essential Information

Sample identity number


Identification number or codes
Location of moist air curing
Method of moist air curing
Period of moist air curing
Maximum and minimum moist
Maximum and minimum water
of the cubes

Additional Information

Time of adding water to the concrete


Time of making the specimens
Time of immersion of specimens in curing tank
Time of removal of specimens from curing tank
Temperature record during moist air curing
Temperature record during water curing
Age(s) at which cubes are to be tested

Affirmation that the test was made in accordance with BS 1881: Part 111 or BS EN 12390-2 as indicated above

Name and Signature of person responsible for test


PAGE
APPENDIX 1 TRIAL MIX FORM .. OF ..
CONTRACT TITLE:
TRIAL MIX NUMBER: .

REFERENCE OR
STAGE I/N ITEM VALUES
CALCULATION
N/mm2 at days (input values for structural element)
1.1 Characteristic strength Specified
Proportion defective 2.5 % (from standard distribution curve multiplier is 1.96)

1.2 Standard deviation Ref N/mm2 or if no data is available N/mm2

1.3 Margin Specified 1.96 x (1.2) = N/mm2

1.4 Target mean strength (1.1) + (1.3 ) N/mm2


1
1.5 Cement strength class Specified 42.5 / 52.5 (circle the strength class used)

Aggregate type: coarse Crushed / Uncrushed (circle the type used)


1.6 -
Aggregate type: fine Crushed / Uncrushed (circle the type used)

1.7 Free-water/cement ratio Ref


Use lower value
Maximum free-
1.8 Specified
water/cement ratio

2.1 Slump Specified mm

2 2.2 Maximum aggregate size Specified mm

2.3 Free-water content Ref kg/m3


PAGE
APPENDIX 1 TRIAL MIX FORM .. OF ..
CONTRACT TITLE:
TRIAL MIX NUMBER: .

REFERENCE OR
STAGE I/N ITEM VALUES
CALCULATION
(2.3) / lower of
3.1 Cement content kg/m3
[(1.7) or (1.8)]

3.2 Max. cement content


3
kg/m3 (input values for structural element)
3.3 Min. cement content Specified Kg/m3
Use (3.1) if (3.3) (3.2) or use 3.3 if (3.3) > (3.1)
Modified free- (If cement content other than the minimum specfed is used a new
3.4
water/cement ratio free-water/cement ratio has to be calculated by (2.3) / (3.3)
Relative density of
4.1 Ref known/assumed (circle the one used)
aggregate (SSD)

4 4.2 Concrete density Specified kg/m3

4.3 Total aggregate content (4.2)-(3.3)-(2.3) kg/m3

5.1 Grading of fine aggregate Percentage passing a 600m sieve %

Proportion of fine
5.2 Ref %
aggregate
5
5.3 Fine aggregate content (4.3) x (5.2) kg/m3

5.4 Coarse aggregate content (4.3) (5.3) kg/m3


PAGE
APPENDIX 1 TRIAL MIX FORM .. OF ..
CONTRACT TITLE:
TRIAL MIX NUMBER: .

CONCRETE CONSTITUENT QUANTITIES FOR MIX DESIGN


COARSE AGGREGATE (KG)
QUANTITIES CEMENT (kg) WATER (kg or litres) FINE AGGREGATE (kg)
10 mm 20 mm 40 mm

per m3 (to nearest 5 kg)

per trial mix of .m3