Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Copyright
Disclaimer
The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. ZG Lightning
Protection Technologies Co.,Ltd shall have no liability for any error or damage
of any kind resulting from the use of this document.
__________________________________________________________________________________
2013-04
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Contents
1 Introduction ..................................................................................... 2
__________________________________________________________________________________
2013-04 1
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
1 Introduction
This document states the user manual of DC SPD Unit, ZG Lightning
Protection Technologies Co.,Ltd part number ZGZH-89, which is intended for
use in indoor RBS sites.
2 General Information
ZGZH-89 SPD Unit is a kind of surge protective device for DC power supply.
It is deployed between indoor DC power supply and outdoor Remote Radio
Unit (RRU), preventing lightning surges from damaging indoor equipment. It
can also provide protection against surge current or transient overvoltage
coming from outdoor environment.
4 Operating Principles
The surge protective components inside of SPD Unit perform short-circuit
immediately when surges invasion occurs from outdoor environment, surge
current will be conducted to the ground (GND) through the earthing line of
SPD Unit. The transient overvoltage on the output port will be limited at a safe
level so that the indoor power supply is under protection. When surges gone
the surge protective components inside will perform high impedance between
power line and ground (GND), after that the power supply will recover to
normal state.
_________________________________________________________________________________
2013-04 2
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Altitude 3000 m
__________________________________________________________________________________
2013-04 3
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
6 Mechanical Information
6.1 Dimensions
Height: 4502 mm
Width: 3402 mm
Depth: 1032 mm
11.5 kg
_________________________________________________________________________________
2013-04 4
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
1
Wall
Impact drill
Figure 2
__________________________________________________________________________________
2013-04 5
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Step 2: Refer to Figure 3, place the expansion bolts into the holes, and fix
them.
2
Wall
Figure 3
Step 3: Fix the SPD Unit with the expansion bolts, and fasten the nuts with a
socket spanner. When installation finished, check if the SPD Unit is fixed
tightly on the wall, as is shown in Figure 4.
3 SPD Unit
Wall
Socket spanner 10 mm
Figure 4
_________________________________________________________________________________
2013-04 6
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Step 4: Strip the outer coating layer of cable with correct peeling length, see
Figure 5 and Figure 6.
4 Unit: mm
Shielding Layer
0V
-48 V
Figure 7
__________________________________________________________________________________
2013-04 7
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Figure 8
Figure 9
_________________________________________________________________________________
2013-04 8
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Figure 10
Figure 11
__________________________________________________________________________________
2013-04 9
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Figure 12
_________________________________________________________________________________
2013-04 10
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Description
Important Note: There is 0 V and -48 V indication on installation panel, DO NOT reverse
48 V and 0 V pairs of output cable.
__________________________________________________________________________________
2013-04 11
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
To secure the discharging path for surge current to GND, the sectional
area of PE cable must be equal to 35mm2, and the length needs to be as
short as possible, because the over-long PE cable will degrade or even
eliminate the protection performance of the SPD Unit.
Check if the cables are all correctly connected and fastened them tightly.
Close the circuit breakers (QF0 to QF6) which are required to be
switched on, turn on the power supply. After that, the SPD Unit is
operational.
This SPD Unit is designed and certified for so the DC input can be protected
with an external fuse with the following specification:
1) Fuse, type gL-gG-gD, in accordance with IEC/EN 60 269-1 and UL 248-8.
2) Circuit breaker in accordance with IEC 60 947-2 and UL 489A..
_________________________________________________________________________________
2013-04 12
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Only after all connections have been checked, the circuit breakers can
be closed and power supply can be switched on.
8.3 Maintenance
In general the SPD Unit needs no special maintenance during its lifetime.
However, the SPD Unit is under condition of long-term operation, the
working status needs to be checked periodically especially after lightning
storm. If no voltage found on output port, the SPD Unit itself and the
power supply system must be checked in time.
The grounding system of the SPD Unit must be checked frequently during
normal operation, especially in lightning storm seasons to make sure it
maintains good grounding connection all the time. Otherwise the lightning
protection performance of the SPD Unit will be degraded more or less. If the
grounding connection opens, the SPD Unit will be failed to provide surge
protection function.
__________________________________________________________________________________
2013-04 13
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
If the SPD inside of SPD Unit found damaged, replace it by a good one at
once, see following 5 steps as shown below.
Step 1: Use a Torx screwdriver to loosen all screws, see Figure 14.
Figure 14
Step 2: Use a straight screwdriver to loosen the slide of the SPD. Select point
A as support, rotate the SPD until the slide is away from the rail, see Figure
15.
Figure 15
_________________________________________________________________________________
2013-04 14
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
Step 3: Push the SPD forward to make sure the bayonet is completely away
from the rail, see Figure 16.
Figure 16
Step 4: Pull out the SPD from the rail, see Figure 17.
Figure 17
__________________________________________________________________________________
2013-04 15
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________
10 Contact Information
Sichuan Zhongguang Lightning Protection Technologies Co.,Ltd
Address: No.19 Tianyu Road, West Park, Chengdu Hi-Tech Zone, Chengdu,
Sichuan, P.R.China, Zip: 611731
_________________________________________________________________________________
2013-04 16