User Manual - ZGZH-89 SPD Unit

Copyright

ZG Lightning Protection Technologies Co.,Ltd 2014. All rights reserved. No


part of this document may be reproduced in any form without the written
permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. ZG Lightning
Protection Technologies Co.,Ltd shall have no liability for any error or damage
of any kind resulting from the use of this document.

__________________________________________________________________________________

2013-04
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

Contents
1 Introduction ..................................................................................... 2

2 General Information ........................................................................ 2

3 Functions and Features.................................................................. 2

4 Operating Principles ....................................................................... 2

5 Key Technical Characteristics and Parameters ........................... 3


5.1 Technical Parameters ......................................................... 3
5.2 Environmental Conditions ................................................... 3

6 Mechanical Information .................................................................. 4


6.1 Dimensions ......................................................................... 4
6.2 Net Weight .......................................................................... 4
6.3 Enclosure Material .............................................................. 4

7 Installation and Cable Connections .............................................. 4


7.1 Preparation .......................................................................... 4
7.2 Position of Installation ......................................................... 5
7.3 Steps of Installation ............................................................. 5
7.4 Installation Completed ....................................................... 11
7.5 Reliable PE Cable Connection .......................................... 12
7.6 Check after Installation ...................................................... 12
7.7 External Fuse Connection ................................................. 12

8 Safety Guide for Operation .......................................................... 13


8.1 Power-Off Operation ......................................................... 13
8.2 Power-On Operation ......................................................... 13
8.3 Maintenance ...................................................................... 13
8.4 Grounding System Check ................................................. 13
8.5 Replace Failed SPD .......................................................... 14
8.6 Replace Failed Circuit Breaker ......................................... 16

9 Storage and Transporting Conditions ........................................ 16

10 Contact Information ...................................................................... 16

__________________________________________________________________________________

2013-04 1
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

1 Introduction
This document states the user manual of DC SPD Unit, ZG Lightning
Protection Technologies Co.,Ltd part number ZGZH-89, which is intended for
use in indoor RBS sites.

2 General Information
ZGZH-89 SPD Unit is a kind of surge protective device for DC power supply.
It is deployed between indoor DC power supply and outdoor Remote Radio
Unit (RRU), preventing lightning surges from damaging indoor equipment. It
can also provide protection against surge current or transient overvoltage
coming from outdoor environment.

3 Functions and Features


1. 48 V DC input, 7440 W output power.
2. 1-path input and 7-path output support, each output features overcurrent
protection.
3. Providing up to 6-path protection against lightning surges coming from
outdoor RRUs.
4. Indoor wall mounting, for easy installation and maintenance.

4 Operating Principles
The surge protective components inside of SPD Unit perform short-circuit
immediately when surges invasion occurs from outdoor environment, surge
current will be conducted to the ground (GND) through the earthing line of
SPD Unit. The transient overvoltage on the output port will be limited at a safe
level so that the indoor power supply is under protection. When surges gone
the surge protective components inside will perform high impedance between
power line and ground (GND), after that the power supply will recover to
normal state.

_________________________________________________________________________________

2013-04 2
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

5 Key Technical Characteristics and Parameters


5.1 Technical Parameters

Table 1 Technical Data

Nominal operating voltage 48 V DC

Voltage range 40.5 to 59.5 V DC

Load current 155 A (max. 25 A for each path)

Maximum output power 7440 W

Surge current handling capability for


4 kA (5 positive+5 negative)
each path (10/350 s)

Limiting voltage (10/350 s,4 kA) 200 V DC

Maximum voltage drop for each output 0.3 V DC

Input cable: 25 mm2 to 70 mm2


Connecting cable specification
PE cable: 35 mm2
(sectional area)
Output cable: 6 to 16 mm2

Input cable: 3.5 Nm


Installation torque PE cable: 3.5 Nm
Output cable: 1.8 Nm

Installation method Wall mounting

Net weight 11.5 kg

5.2 Environmental Conditions

Table 2 Environmental Conditions

Operating temperature 5 to +55 C

Operating humidity 5% to 85%

Altitude 3000 m

__________________________________________________________________________________

2013-04 3
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

6 Mechanical Information
6.1 Dimensions

Height: 4502 mm

Width: 3402 mm

Depth: 1032 mm

Figure 1 Mechanical outline

6.2 Net Weight

11.5 kg

6.3 Enclosure Material

Steel Q235, IP20 protective level for indoor use.

7 Installation and Cable Connections


7.1 Preparation

Installation tools need to be prepared as listed below:

Table 3 Installation Tools

_________________________________________________________________________________

2013-04 4
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

No. Tool Quantity Comment

1 Torx screwdriver T30 1 Used for input cable wiring or maintenance

2 Philips screwdriver 1 Used for output cable wiring or maintenance

3 Slotted screwdriver 1 Used for output cable wiring or maintenance

4 Wire stripper 1 Used for cable stripping

5 Electrician knife 1 Used for cable stripping

6 Impact drill 1 Used for installation

7 Socket spanner 10 mm 1 Used for installation

7.2 Position of Installation

SPD Unit is required to be installed on the wall (wall mounting).

7.3 Steps of Installation

There are 6 steps to finish the installation.

Step 1: Refer to dimensional requirements of Figure 2, punch four 1050


mm holes on the wall by using an impact drill.

1
Wall

Impact drill

Figure 2
__________________________________________________________________________________

2013-04 5
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

Step 2: Refer to Figure 3, place the expansion bolts into the holes, and fix
them.

Expansion bolts M660

2
Wall

Figure 3

Step 3: Fix the SPD Unit with the expansion bolts, and fasten the nuts with a
socket spanner. When installation finished, check if the SPD Unit is fixed
tightly on the wall, as is shown in Figure 4.

3 SPD Unit

Wall

Socket spanner 10 mm

Figure 4

_________________________________________________________________________________

2013-04 6
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

Step 4: Strip the outer coating layer of cable with correct peeling length, see
Figure 5 and Figure 6.

4 Unit: mm

Figure 5 Stripping length for input or PE cable

Shielding Layer

0V

-48 V

Figure 6 Stripping length for output cable

Step 5: Input cable connection and fixing.

Penetrating input and PE cables into corresponding terminals via harness


washers on the bottom of SPD Units cabinet, using TORX screwdriver to fix
cables tightly, see Figure 7.

Figure 7

__________________________________________________________________________________

2013-04 7
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

Using strapping tapes to fix cables on support bars, see Figure 8.

Figure 8

Step 6: Output cable connection and fixing.

Loosening screws by using philips screwdriver to uninstall cable clampers.

Figure 9

_________________________________________________________________________________

2013-04 8
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

Penetrating output cables into corresponding terminals via harness washers


on the bottom of SPD Units cabinet, make sure there is no divergence for
cable stripping part, using philips screwdriver to fix them tightly, see Figure
10.

Figure 10

Adjusting the shielding layer of output cable to ensure there is tight


connection among shielding layer, cable clampers and support bar, using
philips screwdriver to fix them together tightly, see Figure 11 and 12.

Figure 11

__________________________________________________________________________________

2013-04 9
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

Figure 12

_________________________________________________________________________________

2013-04 10
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

7.4 Installation Completed

Description

1. Input and PE cable terminal block


2. Input and PE cable strapping tape
3. Output cable terminal block

4. Output cable clamper


5. -48 V and 0 V pairs of output cable
Figure 13 Finished cable connection diagram

Important Note: There is 0 V and -48 V indication on installation panel, DO NOT reverse
48 V and 0 V pairs of output cable.
__________________________________________________________________________________

2013-04 11
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

7.5 Reliable PE Cable Connection

To secure the discharging path for surge current to GND, the sectional
area of PE cable must be equal to 35mm2, and the length needs to be as
short as possible, because the over-long PE cable will degrade or even
eliminate the protection performance of the SPD Unit.

7.6 Check after Installation

Check if the cables are all correctly connected and fastened them tightly.
Close the circuit breakers (QF0 to QF6) which are required to be
switched on, turn on the power supply. After that, the SPD Unit is
operational.

7.7 External Fuse Connection

This SPD Unit is designed and certified for so the DC input can be protected
with an external fuse with the following specification:
1) Fuse, type gL-gG-gD, in accordance with IEC/EN 60 269-1 and UL 248-8.
2) Circuit breaker in accordance with IEC 60 947-2 and UL 489A..

_________________________________________________________________________________

2013-04 12
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

8 Safety Guide for Operation


8.1 Power-Off Operation

Before performing installation or maintenance, power supply to the SPD


Unit must be switched off. Operation with power-on is prohibited.

8.2 Power-On Operation

Only after all connections have been checked, the circuit breakers can
be closed and power supply can be switched on.

8.3 Maintenance

In general the SPD Unit needs no special maintenance during its lifetime.
However, the SPD Unit is under condition of long-term operation, the
working status needs to be checked periodically especially after lightning
storm. If no voltage found on output port, the SPD Unit itself and the
power supply system must be checked in time.

8.4 Grounding System Check

The grounding system of the SPD Unit must be checked frequently during
normal operation, especially in lightning storm seasons to make sure it
maintains good grounding connection all the time. Otherwise the lightning
protection performance of the SPD Unit will be degraded more or less. If the
grounding connection opens, the SPD Unit will be failed to provide surge
protection function.

__________________________________________________________________________________

2013-04 13
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

8.5 Replace Failed SPD

If the SPD inside of SPD Unit found damaged, replace it by a good one at
once, see following 5 steps as shown below.

Step 1: Use a Torx screwdriver to loosen all screws, see Figure 14.

Loosen all screws

Figure 14

Step 2: Use a straight screwdriver to loosen the slide of the SPD. Select point
A as support, rotate the SPD until the slide is away from the rail, see Figure
15.

Figure 15

_________________________________________________________________________________

2013-04 14
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

Step 3: Push the SPD forward to make sure the bayonet is completely away
from the rail, see Figure 16.

Figure 16

Step 4: Pull out the SPD from the rail, see Figure 17.

Figure 17

Step 5: Reverse operation from Step 4 to Step 1 to install a new SPD,


replacement completed.

__________________________________________________________________________________

2013-04 15
User Manual ZGZH-89 SPD Unit
__________________________________________________________________________________

8.6 Replace Failed Circuit Breaker

If the Circuit Breaker inside of SPD Unit found damaged, replace it by a


new one at once by following the same procedures in Figure 14 to
Figure 17 above, the screwdriver for loosening and tightening the screws
required to be changed to Philips or Slotted type.

9 Storage and Transporting Conditions


The transportation is to be done when the package is in good condition. No
strong shock and impact are allowed during transportation. Keep the package
away from moist materials, exposure to rain must be avoided.

Product with package can be stored in room at temperature range of 40C to


+70C; make sure the package is stored in good ventilated condition and the
relative humidity is no more than 90%; no corrosive gas is allowed in storage
environment. Re-check the product before using it if stored longer than one
year.

10 Contact Information
Sichuan Zhongguang Lightning Protection Technologies Co.,Ltd

Address: No.19 Tianyu Road, West Park, Chengdu Hi-Tech Zone, Chengdu,
Sichuan, P.R.China, Zip: 611731

Fax: +86 28 87843532

Service phone: +86 28 66755400

Website: www.zhongguang.com E-mail: support@zhongguang.com

_________________________________________________________________________________

2013-04 16