DATOS
Q Rio 7.6472 m3/s 7647.2 lt/s
Q Cedula 5.5418 m3/s 5541.8 lt/s
d1 0.5236464 m 1.718 pies
d2 0.5715 m 1.875 pies
B 9.5335344 m 31.278 pies
Cotas Aguas Arriba 4683.79 m
Cotas Aguas Abajo 4682.45 m
Longitud entre Cotas 50.55108 m 165.85 pies
Velocidad 1.18 m/s
g 9.81 m2/s
n 0.012
J1= 0.0100246601
J=2 0.0075803663
E1= 0.5946147996
E2= 0.6424683996
Io= 0.0265078412
4
AL= 2.7027796397
Yc=
L=
L(Recomendado)
Hd= 0.28217581
Hd= 0.23407613
Hmuro= 2.06217581
H 1.6
R1 0.32
R2 0.8
HO=P 1.6
Hd= 0.28
n(Ssimeni) 1.85
K(tipo Creaguer) 2
1 0.214
2 0.115
3 0.22
4 0.48
a= 0.3424
b= 0.184 ASUMIDO
r= 0.352 0.4
R= 0.768
C1 0.127
C2 0.16
Xu calculado para un Y= Ho+Z
Y= 1.6
X= 1.04855244
Y X
Y PERFIL DEL CIMA
0 0
0.1 0.23426882 0 0.2 0.4
0.2 0.34074807 0
0.3 0.42424611 0.2
0.4 0.49562399
0.4
0.5 0.55916002
0.6 0.61707335 0.6
0.7 0.67069372
0.8
0.8 0.72089372
0.9 0.76828305 1
1 0.81330797 1.2
1.3 0.93722968
1.6 1.04855244 1.4
1.6
1.8
V= 6.69132
verificando
d1= 0.0235139447
V= 6.75041523
verificando
d1= 0.0233 m
d1<0.1 d1= 0.1 m
d2= 0.90672303
dn= 0.50672303
d2= 0.7884548
2.- Calculo de la longitud del colchon
L=6*F1*d1
siedo F1= V1/(gxd1)(1/2)
F1= 6.75580842
L= 4.05348505 (Safranez)
L=4*d2
L= 3.15381922 (U.S. Bureau)
L=d2+(V1/(gxd1)^0.5)
L= 7.54426322
ASUMIDO
L= 4.1307
Ah= 1.85314
DISEO DE BOCATOMAS
REMANSO
METODO APROXIMADO)
L= 3.6105241222 m
asumido 3.7
A ELIMINAR
D DE BARRAJE
0.5715
1.5558788 m
L(Recomendado) 6.3556896 m
SOBRE BARRAJE
E DE VERTEDOR
ho= 0.6
h= 0.75 reemplazar
h ahogada= 0.25 reemplazar
MURO
H azud 1.6
H=hd 0.28217581
Bordo 0.18 reemplazar
DE CRAEGUER
PERFIL DEL CIMACEO TIPO CREAGER
0.2 0.4 0.6 0.8 1 1.2
TU DEL COLCHON
DISEO DE DESARENADOR
DATOS
V 1 m/s
Q 1.85 m3/s
par 0.5 mm
Ps 1.554 gr/cm3
Hprof 2.8 m
S 1.5 %
k 6
CANAL RECTANGULAR
bc 1.1 m
Yc 0.6 m
v 1.25 m/s
Vertedor Excedencias
Vmax 1 m/s
Hd 0.18 m
C 2
Seccion de Compuertas
Cd 0.75
g 9.81 m/s2
V= 31.1126984 cm/s
0.31112698 m/s
d= 0.5
w(cm/s) = 5.4
w(m/s) 0.054
d= 0.5
w(cm/seg) 15
w(m/seg) 0.15
2.2 Abaco segn Sellerio
d= 0.5
w(cm/seg) 5
w(m/seg) 0.05
w= 0.100 m/s
d= 0.5
w= 0.08912058 m/s
b= 2.123616145 m
adoptado b= 2.2 m
L= 17.42311109 m
asumido L= 17.5 m
v= 103.6 m3
V= 107.8 m3 Vtanque>Vagua
T1= 2.2
T2= 1.1
Lt= 1.327817459
asumido Lt= 1.4
Lv= 12.11247727
5.1.- Calculo de
a f(a)
315.4510019 21.0490911 315.451043
5.2.- Calculo de R
R= 32.9701787
Asum R= 33.2
Lt= 11.92436799 m
L= 12.01842263 m
Ltotal= 30.91842263 m
Az= 0.442776339
Asumido Az= 0.5 m
hc= 3.12 m
A0= 0.30655189 m2
con I= 0.56
v= 5.899234694 ok esta debajo
OR
aria entre 1.28 y 9.35