Abstract - In the past the basic function of motor Hence motor should be provided with overload
protection was to detect the fault and due to failures of protection.
motor. If the motor protections occur then the motor
working normal condition without failure when protection is ii) Single phasing: One of the supply lines gets
not provided then the result was unplanned shut down and disconnected due to blowing of fuse or circuit in one
lost the production and unusable product. Using modern the three supply connections. In such cases the motor
electronic motor protection, increased productivity and shut continues to run on single phase supply. If the motor
down the processes. By analyzing abnormal operating is loaded to its rated full load, it will draw excessive
conditions having more data such as motor temperature, currents single phasing. The winding get overheated
overloading, it is possible to minimize faults and downtime and damage is caused. The single phasing causes
by taking preventive action. This paper discussed causes of unbalanced load resulting excessive heating of rotor
motor failure and proper protection can be selected to due to negative sequence component of unbalance
secure the motor. current. Static single phasing relays becoming very
popular.
Key Words: Induction motor, motor fault, relay, motor
protection. iii) Stalling: If the motor does not start due to excessive
load, it draws heavy current. It should be immediately
disconnected from supply.
1. INTRODUCTION
iv) Stator earth faults: Faults in motor winding are mainly
Three phase Induction motors (IMs) used as actuators in caused by failure of insulation due to temperature
many industrial processes, in fact 90 to 95% motors used in rise.
industries are three phase Induction motors. Although IMs
are reliable, they are subjected to some unwanted stresses v) Phase to phase faults: These are relatively rare due to
such as thermal, ambient, causing faults resulting in failure enough insulation due between phases. Earth faults
monitoring of a IM is a fast emerging technology for the are relatively more likely.
exploration of initial faults, elusion unexpected defeat of an
industrial process. Protection of motor against possible vi) Inter- turn faults: These grow into earth faults. No
problem such as unbalance supply voltage, increasing separate protection is generally provided against
temperature, occurring in the progress of its operation is inter-turn faults.
very intrinsic in plant as an actuator. IMs protected using
some component such as timer, current and voltage sensing vii) Rotor faults: These are likely to occur in wound rotor
relays, sensor to avoid the major damage. motors, due to insulation failure.
2. ABNORMAL OPERATING CONDITIONS AND viii) Failure of bearing: These causes locking up of rotor.
CAUSES OF FAILURE IN IMs The motor should be disconnected. Bearing should be
replaced.
Three phase IMs are very widely used for industrial use. The ix) Unbalance supply voltage: these causes heating up of
abnormal conditions are summarized below. rotor due to negative sequence current in stator
i) Prolonged overloading: It is caused by mechanical winding.
loading, short time cyclic overloading. Overloading
results in temperature rise of winding and x) Supply under voltage: The under voltage supply cause
deterioration of insulation resulting in winding fault. increase in motor current for the same load.
2017, IRJET | Impact Factor value: 5.181 | ISO 9001:2008 Certified Journal | Page 1443
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 -0056
Volume: 04 Issue: 01 | Jan -2017 www.irjet.net p-ISSN: 2395-0072
grounded
3. PLANT MANAGEMENT AND MOTOR
System
PROTECTION
- High over
In prescript to induce quality products at the desired temperatures
expense, all aspects of manufacturing costs need to be
analyzed. Investment costs, operational costs, maintenance - Stalling
costs and repair costs and lost production costs due to down
time are the components of the operational costs. 3. Pre - Avoid stop - Ground on
Investment costs and energy usage can be optimized by close warning by isolated
coordination of the motor and burden, since lowest preventive system
horsepower motor is selected and to bolt at a higher
measures
frequency level than if it were oversized. Appropriate - Failures in
selection and application of motor protective equipment can
- Switch off cooling
downstate the cost. Repairs can be kept to minimum by early
finding of faults. A pre warning and initiate to prevent at system
function can mitigate unplanned down time by allowing the convenient
operator to make adjustment or automatically switch off time -
before damage actually occurs. Remedial maintenance can Asymmetrical
be performed, of costly repairs. supply
2017, IRJET | Impact Factor value: 5.181 | ISO 9001:2008 Certified Journal | Page 1444
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395 -0056
Volume: 04 Issue: 01 | Jan -2017 www.irjet.net p-ISSN: 2395-0072
mechanism locks itself in operated condition until reset costly down times. With electronic circuitry additional
mechanically. Electronic overload relays are a relatively new functions mainly aimed at supporting unplanned shutdown
technology. They provide more flexibility with regard to the or maximum motor output are possible. In many cases, a
quality of the thermal simulation and trip characteristic. warning signal indicating that thermal trip is pending can
Electronic overload can perform additional functions for increase productivity. By calling attention to the overload
extra cost. condition prise to tripping, an operator has time to clear the
overload without shutting down the motor. With
B) PROTECTION AGAINST SINGLE PHASING AND SUPPLY microprocessor relays and assuming a stable load even the
UNBALANCE time left before trip indicate as shown in figure 1.