Temperature Sensors Room, Duct, Immersion, Strap- output 0-10 Vdc or 4-20 NTC 20K ( VCP
on and Outdoor temperature mA, with or without LCD
display Sweden)
sensors, transmitters/transducers.
Wind Speed and Wind The sensors accurately measures To be assemblied on wall
03101-L(campbellsci)
the wind speed and direction, or on mast
Speed/Direction Sensors
providing output signals
compatible with most DDC
controllers.
Current Sensors is a device that detects electric The generated signal can CSS-O-F5-001
current (AC or DC) in a wire be then used to display (Honeywell)
the measured current in
an ammeter
Used for Field Controls in Output 0-10 Vdc or 4-20 C29245A2003
C AR BON D IO X IDE Green Building mA, with or without LCD (Honeywell)
Applications. display
(C O2) S ENS OR
Humidity Sensors Room, Duct and Outdoor RH output 0-10 Vdc or 4-20 H7625A2010
transmitters/transducers and mA, with or without LCD (Honeywell)
hygrostats/humidistats. display
Dew Point Sensors HSS-DPS (Honeywell)
Air quality (VOC) CO2 by analyzing substances Output 0-10 Vdc or 4-20 C7232A1008
that directly affect users well- mA, with or without LCD ((CAREL))
being by using MEMS sensors to display
measure VOCs, in addition to a
humidity and temperature
sensors
Flow Rate Air Flow Paddle Switch intended Use VCPs detectors and ENVIROMUX-CLP10-
(Liquid)Sensor to monitor air flow and non- alarm band to prevent or LD
aggressive gaseous within a duct minimize water damages. (networktechinc)
and provides a switched output
on detection of either a specified
air velocity or flow failure
Enthalpy Sensors Digital enthalpy Can be used to easily
(humidity/temperature) daisy chain two C7400S Digital
sensor for use with Sylk- enthalpy sensors Enthalpy Sensor
enabled devices, such as the together to measure
JADE economizer controller outdoor and mixed air (Honeywell)
S M OKE S ENS OR Duct Smoke Detectors for Probe lengths 300 mm HONEYWELL 5808W3
Ventilation Systems and 600 mm
PHOTOELECTRIC
WIRELESS SMOKE /
HEAT DETECTOR
T-4506 Series(johnsoncontrols)
THER M OS TATS (F AN C O IL)
Switches Example
Air or gas flow switch Model 530 (dwyer)
Differential pressure switch Series 1900 (dwyer)
Ethernet switches Model: FS305 (SOHO)
https://www.elgato.com/sites/default/files/VOC-EveRoom-EN.pdf
https://www.campbellsci.com/wind-speed-direction
https://en.wikipedia.org/wiki/Current_sensor
https://www.lufft.com/products/compact-weather-sensors-293/ws504-umb-smart-weather-
sensor-1836/
http://www.ebay.com/bhp/honeywell-smoke-detector
www.johnsoncontrols.com/buildings/hvac-controls/thermostats/dual-temperature-thermostat
http://www.networktechinc.com/rope-style-leak-detector.html
https://buildingcontrols.honeywell.com/Econmizer-Sensors/C7400S-Digital-Enthalpy-Sensor
https://www.kele.com/gas-and-specialty-sensors/ba/420co.aspx
http://www.netgear.com.sg/home/products/networking/switches/soho-ethernet-
switches/default.aspx?cid=wmt_netgea#tab-models
http://www.ventilationcontrolproducts.net/
https://www.systemair.com/globalassets/downloads/leaflets-and-catalogues/english/nb_ahu.pdf
http://www.carel.com/air-conditioning-parametric-controls
http://www.toshiba-aircon.co.uk/products/air-handling-unit-applications/air-handling-unit-
applications/air-handling-unit-bms-control#
http://www.toshiba-aircon.co.uk/products/air-handling-unit-applications/air-handling-unit-
applications/air-handling-unit-bms-control
http://www.barkell.co.uk/web/hvac-controls/ahu-controls.htm
https://www.engineeredair.com/parts/351627627.pdf
http://www.petra-eng.com/?pid=PR&cai=49&iti=944
https://customer.honeywell.com/resources/techlit/TechLitdocuments/63-0000s/63-9285.pdf
https://customer.honeywell.com/resources/techlit/TechLitDocuments/67-0000s/67-7500.pdf
http://slideplayer.com/slide/5944752/
https://discountpdh.com/course/hvac_controls_introduction.pdf
https://customer.honeywell.com/resources/Techlit/TechLitDocuments/63-0000s/63-9538.pdf
https://buildingcontrols.honeywell.com/Remote-Temperature-Controllers