Drilling template
The ProCash 280FL is installed using the drilling template supplied with the device. If
required, the drilling template can be ordered from Wincor Nixdorf.
1
Tear-off sensor
All safes have holes for mounting a tear-off sensor but the mounting set for the tear-off
sensor is not supplied with the device.
To ensure that the tear-off sensor can be mounted after the device has been installed, a
hole for the tear-off sensor has to be drilled prior to the installation of the installation
frame.
To be able to mount the tear-off sensor, the hole has to be cleaned with a vacuum
cleaner and a resin cartridge (e.g. UPAT multicone, Fischer resin cartridge RM) has to
be inserted.
Thus the alarm technician will be able to mount the tear-off sensor in the safe easily
after the device is installed.
Ask your alarm technician about the size of the hole and the cartridge. The maximum
diameter for the hole to take the fixing is;
22 mm (0.87") in safe.
Drilling diagram
The following figure specifies the distance from the edge of the device of the drill holes
that are used to secure ProCash 280FL and the tear-off sensor.
2
Drilling diagram (Frontload)
Mounting the ATM to the Floor | 8/30/2013
Drilling depths:
3
Mounting sets for UL safe
If the mounting set is not provided, it should be ordered from Wincor Nixdorf under part
No.01750006706.
If you are using different fastening materials please follow the following specifications to
select those items.
Item Quantity
Figure
required
Caulking cartridge
A caulking gun is not 1
included in the delivery
package.
4
Installation procedure (Frontload) UL safe/CEN L safe
This section describes how to proceed with the installation of a ProCash 280FL with UL
safe or CEN L safe.
Make sure that the clearance between the vents and the wall is at least 50 mm
(1.97").
If a tear-off sensor is to be installed, also mark the holes for the tear off sensor.
Position the drilling template & mark the holes to be drilled for mounting the
device & the mounting bracket.
5
Free-standing installation for ProCash 280 Frontload
6
The drilled holes in the concrete foundation must have a depth of at least 125
mm (4.92") for the safe. For the hole diameter please refer to the instructions for
the caulking cartridge.
The drilled hole in the concrete foundation must have a depth of at least 40 mm
(1.57") for the tear-off sensor. Consult your alarm technician about the size of the
hole and the fixing.
Clean the bore holes as specified in the mounting instructions of the caulking
cartridge.
Mounting structure
1. Device 4. Screed
Mounting the ATM to the Floor | 8/30/2013
To ensure that the safe does not become detached, the threaded rods must
be fastened in the concrete foundation.
This dimension is needed if the threaded rods from the mounting set are
used. For a different measure the threaded rods must be modified or replaced
by equivalent ones.
7
2) Fixing the threaded rod in the hole
Drill a hole to the size and Blow the hole clean with When using a new
embedment required. compressed air, brush the cartridge for the First time,
hole and blow it clean First press out the
again. adhesive until the two
components fully mix.
8
Allow the adhesive to cure for the specified time prior to applying any load.
First secure the threaded rods in the concrete foundation as specified in the
mounting instructions of the caulking cartridge.
9
Lifting the Cash Media Dispenser (CMD-V4) up
When mounting the locking axle ensure that no cables are damaged in
the process.
Check the CMD-V4 for a secure fit. The locking axle must be firmly in
place.
10
Screw the device at the attachment
points (1) (for material see section
"Mounting set").
Tel: +94115322905
Mobile: +94726868040
Email: buddhika.j@Informaticsint.com