For AVM2PC-10hp/AVM2PC-20hp

INJECTION PUMP TEST SPECIFICATIONS 294000-0160


Supply Voltage 14 0.2 V
Injection Pump 294000-016# (HP3)
Rotation Clockwise viewed from drive
Manufacturer NISSAN MOTOR side
Vehicle Model X-TRAIL SCV Terminal resistance 2.10 0.15 [20 C]
Engine Type YD22 (Rated Voltage) ( 12 V )

1. TEST CONDITIONS
1) Test Oil SAE J967 (ISO4113) 5) High Pressure Pipe 3 6.35 500 mm (Pump - Rail)
2) Feed Pressure 19.6 kPa ( 0.2 kg/cm2) 4 8 900 mm (Rail - Nozzle holder)

3) Pressur Regulator Volume 40 cc 6) Fuel Temperature 40 5 C


4) Controller Set Part Number 95191-00250

2. NOTE (If you do not observe following cautions, accidents leading to injury or damage to the vehicle or product could result)
(1) Confirm the pressure reguletor handle is completely turned to the left, then stop the pump operation.
(2) Refer to the adjustment instruction manual, when you adjust a pump.

3. RUNNING
Pump Speed Rail Pressure
(rpm) (MPa) Condition Remarks

350 25 (254.9 kgf/cm2) Drive more than 15 seconds.


No fuel leaks, no abnormal
2
2000 35 (356.9 kgf/cm ) noise, and no abnormal Drive more than 3 minutes.
temperature rising.

4. FUEL TEMP SENSOR CHECK


Pump Speed Sensor Resistance
(rpm) (k ) Remarks

1.2 0.7 Inlet Fuel Temp. : 40.0 5.0 C

5. FUEL DELIVERY INSPECTION (CALIBRATION)


Pump Speed Rail Pressure Target Quantity
(rpm) (MPa) (cc/200rev) Remarks

350 25 (254.9 kgf/cm2) 10.0 5.0 I1 = 1660 mA, I2 = 1710 mA, Is = 1760 200 mA
2000 160 (1631.6 kgf/cm2) 65.0 17.0 Is - 480

NOTE : Is means SCV actuation current at 350 rpm pump speed of calibration.
NOTE : The SCV current at calibrations 3 and 4 is calculated automatically using the DST-1.

6. FUEL DELIVERY INSPECTION (FULL, HI-SPD)


Pump Speed Rail Pressure Target Quantity
(rpm) (MPa) (cc/200rev) Remarks

2000 160 (1631.6 kgf/cm2) 144.0 or more SCV current = 0 mA

7. FUEL DELIVERY INSPECTION (NO FUEL DELIVERY)


Pump Speed Rail Pressure Target Quantity
(rpm) (MPa) (cc/200rev) Remarks

2500 0 0.8 or less SCV current = 2200 mA

2005.08.02
For AVM2PC-10hp/AVM2PC-20hp 294000-0160

8. FUEL DELIVERY INSPECTION (FULL, LO-SPD)


Pump Speed Rail Pressure Target Quantity
(rpm) (MPa) (cc/200rev) Remarks

100 35 (356.9 kgf/cm2) 144.0 or more SCV current = 0 mA

9. FUEL DELIVERY INSPECTION (OVER FLOW, LO-SPD)


Pump Speed Rail Pressure Overflow Quantity
(rpm) (MPa) (cc/min) Remarks

100 35 (356.9 kgf/cm2) 145.0 95.0 SCV current = 0 mA

10. FUEL DELIVERY INSPECTION (OVER FLOW)


Pump Speed Rail Pressure Overflow Quantity
(rpm) (MPa) (cc/min) Remarks

1000 0 245.0 80.0 SCV current = 2200 mA

NOTE : The over-flow volume SCV current is automatically calculated by DST-1.