Mode l LHA M o de l L T/ L G
Mode l LHC M o de l TL A - 2
Mode l LHS M o de l TL A - 1
Mode l LHW M o de l TL B - 2
Action Description
Before Swing The lever descends as it swings. After swing completion, Action completed
(Released State) (For LHS, the lever swings parallel.) it descends vertically. (Clamped State)
Application Examples
375
Swing Clamp
Digest
Manual Operation
The Fastest Lever Change, Only One Bolt for
Accessories
Hole Clamp
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Air Sensing Swing Clamp
Centering Vise
M o de l L HW FVA
FVD
FVC
Clamp-unclamp confirmation with built-in air catch sensor
Control Valve
for smaller footprint fixtures.
BZL
46.5 mm
VFM
VFJ
VFK
79.5 mm Same Size
Pull Stud Clamp
33 mm Compact FP
For Action FQ
Confirmation Customized
< Comparison Model > Air Sensing Model Spring Cylinder
Standard Model External Dimensions P. 387 External Dimensions P. 421 External Dimensions P.4 3 5
Air Sensing
External Dimensions P. 391
Manifold Option
Air Sensing
Able to Install External Dimensions P. 393
Piping Option Air Sensor
Quick Change
External Dimensions P. 395 External Dimensions P. 423 External Dimensions P .4 3 7
Lever Type A
Quick Change
External Dimensions P. 397 External Dimensions P.4 3 9
Lever Type F
Option
Long
Long Stroke Option External Dimensions P. 401
Swing Angle 30
45 External Dimensions P. 405 External Dimensions P.4 4 3
Selectable Option 60
Standard Model External Dimensions P. 503 External Dimensions P. 529 External Dimensions P.5 4 7
Long
Long Stroke Option External Dimensions P. 511 External Dimensions P. 533
Swing Angle 30
45
60
External Dimensions P. 515 External Dimensions P. 535
Selectable Option
TLZ-L2TLZ-LB TLZ-L2TLZ-LB TLZ-L2TLZ-LB
Lever
P. 519 P. 537 P.5 5 1
Accessories
377
Swing Clamp
Digest
High-Power
Series
Pneumatic Series
MAX. 7MPa
Model LH W P.449 Model LT/LG P.471 Valve / Coupler
Hydraulic Unit
Able to
Option for Dog Install Dog SFC
LK W
Balance Lever Option External Dimensions P. 487 LM/LJ
T MA - 2
Long
T MA - 1
Long Stroke Option
Work Support
Swing Angle 30
LD
45
External Dimensions P. 489
Selectable Option 60
LC
T NC
LZH-T LZ-LE1LZ-LE2LZH-FLZH-B
Lever TC
LZH-ALZH-W P. 470 LZH-ALZH-W
Accessories
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
2 sizes smaller with equivalent clamping force. Mechanical lock and Pull Stud Clamp
FP
hydraulic pressure allow for strong clamping and holding force. FQ
378
Double Action Swing Clamp model LHA
PAT.
Index
Specifications P.382
Performance Curve
External Dimensions
Accessories
Cautions
High-Power
Cross Section T a p e r S le e v e Series
Pneumatic Series
S w i n g Le v e r Hydraulic Series
Dus t Se a l
Valve / Coupler
Excellent Coolant Resistance Hydraulic Unit
Manual Operation
Accessories
BZL Speed Control Valve P i s t on R od
(Sold Separately) Cautions / Others
Hole Clamp
SFA
SFC
Swing Clamp
Hi g h E f f i c i e n c y L HA
Long Guide Ratio LHC
Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
High Speed
LD
Able to Use Longer Levers LC
T NC
The long guide ratio allows for longer clamping levers by supporting the rod. TC
Air Sensing
The guide is located between the flange and at the edge of the rod.
Lift Cylinder
Compact Cylinder
LL
High Speed and High Endurance with Rotation Mechanism LLR
Cam Shaft
LLU
The resistance created by the swing action is minimized by having (Piston Rod)
Lead Groove DP
the outer race rotates in accordance with the steel ball movement. DR
Outer Race DS
High endurance is achieved by enlarging rod diameter which decreases
DT
torque and by using bigger steel balls and making the lead groove.
Block Cylinder
(Position repeatability for swing is within 0.5.) DBA
DBC
Steel Ball
Centering Vise
Excellent Coolant Resistance FVA
FVD
Our exclusive dust seal is designed to protect against high pressure coolant. Rotation Mechanism
FVC
It also has high durability against chlorine-based coolant by using a sealing Control Valve
LH A 048 0 - C R -
1 2 3 4 5 6
1 Body Size
2 Design No.
0 Revision Number
3 Piping Method
C Gasket Option (With G Thread Plug) C G S
G Gasket Option (With R Thread Plug
S Piping Option (Rc Thread Port)
Speed control valve (BZL) is sold separately. Gasket Option Piping Option
Refer to P.891. With G Thread Plug With R Thread Plug Rc Thread Port
Able to attach No Gasket Port
speed control valve
4 Swing Direction when Clamping
R Clockwise R L
Swing Direction Swing Direction
L Counter-Clockwise when Clamping when Clamping
6 Option
Please contact us when action check method has a combination with option.
381
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
Specifications
High-Power
Model No. LHA0360 LHA0400 LHA0480 LHA0550 Series
Cylinder Area for Locking cm2 3.54 5.00 6.95 10.3
Pneumatic Series
Cylinder Inner Diameter 1 mm 26 31 37 44
Rod Diameter 1 mm 15 18 22 25
Hydraulic Series
P ( 1-0.0021L) P ( 1-0.0016L) P ( 1-0.0009L) P ( 1-0.0011L)
Clamping Force 6 Option Blank/A/F/Q/Y F= F= F= F=
2.9379+0.0052L 2.0920+0.0040L 1.4892+0.0018L 1.0039+0.0011L
(Calculation Formula)2 Valve / Coupler
F1= (L 2/L 3)0.354P F1= (L 2/L 3)0.5P F1= (L 2/L 3)0.695P F1= (L 2/L 3)1.03P Hydraulic Unit
kN 6 Option P
F2= (L1/L 3)0.354P F2= (L1/L 3)0.5P F2= (L1/L 3)0.695P F2= (L1/L 3)1.03P
Manual Operation
Full Stroke mm 13.5 14.5 15.5 18.5 Accessories
Swing Stroke (90
) mm 5.5 6.5 7.5 8.5
6 Option Cautions / Others
Vertical Stroke mm 8 8 8 10
Blank/A /F/P
Swing Angle Accuracy 903
Swing Completion Position Repeatability 0.5 Hole Clamp
Option Q15 Q20 Q25 Q30 Q35 Q15 Q20 Q25 Q30 Q35 Q40 Q15 Q20 Q25 Q30 Q35 Q40 Q15 Q20 Q25 Q30 Q35 Q40 Q45 Q50 SFA
SFC
Full Stroke mm 20.5 25.5 33 38 43 21.5 26.5 34.5 39.5 44.5 49.5 22.5 27.5 36 41 46 51 23.5 28.5 33.5 42 47 52 57 62
Swing Stroke (90
) mm 5.5 5.5 8 8 8 6.5 6.5 9.5 9.5 9.5 9.5 7.5 7.5 11 11 11 11 8.5 8.5 8.5 12 12 12 12 12 Swing Clamp
6 Option Q
Vertical Stroke mm 15 20 25 30 35 15 20 25 30 35 40 15 20 25 30 35 40 15 20 25 30 35 40 45 50 L HA
LHC
Swing Angle Accuracy 903
LHS
Swing Completion Position Repeatability 0.5 LHW
Option Y30 Y45 Y60 Y30 Y45 Y60 Y30 Y45 Y60 Y30 Y45 Y60 LT /LG
Full Stroke mm 10.9 11.5 12.2 11.5 12.3 13 12.1 13 13.8 14.7 15.6 16.6 T LA - 2
T LB- 2
Swing Stroke mm 2.9 3.5 4.2 3.5 4.3 5 4.1 5 5.8 4.7 5.6 6.6
6 Option Y T LA - 1
Vertical Stroke mm 8 8 8 8 8 8 8 8 8 10 10 10
Link Clamp
Swing Angle Accuracy 303 453 603 303 453 603 303 453 603 303 453 603
LK A
Swing Completion Position Repeatability 0.5
LK C
Max. Operating Pressure MPa 7 LK W
Min. Operating Pressure3 MPa 1.5 LM/LJ
Withstanding Pressure MPa 10.5 T MA - 2
T MA - 1
Operating Temperature 0 70
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32 Work Support
LD
LC
Model No. LHA0650 LHA0750 LHA0900 LHA1050
T NC
Cylinder Area for Locking cm2 13.4 20.3 29.5 41.3 TC
Cylinder Inner Diameter 1 mm 51 62 76 91 Air Sensing
Rod Diameter 1 30 35.5 45 55 Lift Cylinder
mm
LLW
P ( 1-0.0009L) P ( 1-0.0007L) P ( 1-0.0009L) P ( 1-0.0008L)
Clamping Force 6 Option Blank/A/F/Q/Y F= F= F= F=
0.7822+0.0010L 0.5175+0.0006L 0.3547+0.0004L 0.2495+0.0002L Compact Cylinder
(Calculation Formula)2 LL
F1= (L 2/L 3)1.34P F1= (L 2/L 3)2.03P F1= (L 2/L 3)2.95P F1= (L 2/L 3)4.13P
kN 6 Option P LLR
F2= (L1/L 3)1.34P F2= (L1/L 3)2.03P F2= (L1/L 3)2.95P F2= (L1/L 3)4.13P
LLU
Full Stroke mm 20 24 26 32 DP
Swing Stroke (90
) mm 10 12 14 16 DR
6 Option DS
Vertical Stroke mm 10 12 12 16
Blank/A /F/P DT
Swing Angle Accuracy 903
0.5 Block Cylinder
Swing Completion Position Repeatability
DBA
Option Q15 Q20 Q25 Q30 Q35 Q40 Q45 Q50 Q20 Q25 Q30 Q35 Q40 Q45 Q50 Q20 Q25 Q30 Q35 Q40 Q45 Q50 Q25 Q30 Q35 Q40 Q45 Q50
DBC
Full Stroke mm 25 30 35 40 50 55 60 65 32 37 42 47 55 60 65 34 39 44 49 57 62 67 41 46 51 56 61 66
Swing Stroke (90
) mm 10 10 10 10 15 15 15 15 12 12 12 12 15 15 15 14 14 14 14 17 17 17 16 16 16 16 16 16 Centering Vise
6 Option Q
mm 15 20 25 30 35 40 45 50 20 25 30 35 40 45 FVA
Vertical Stroke 50 20 25 30 35 40 45 50 25 30 35 40 45 50
FVD
Swing Angle Accuracy 903
FVC
Swing Completion Position Repeatability 0.5
Control Valve
Option Y30 Y45 Y60 Y30 Y45 Y60 Y30 Y45 Y60 Y30 Y45 Y60
BZL
Full Stroke mm 15.3 16.5 17.6 18.7 20 21.3 19.9 21.4 22.9 24.8 26.6 28.4 BZT
Swing Stroke mm 5.3 6.5 7.6 6.7 8 9.3 7.9 9.4 10.9 8.8 10.6 12.4 BZX/JZG
6 Option Y
Vertical Stroke mm 10 10 10 12 12 12 12 12 12 16 16 16 Pallet Clamp
Swing Angle Accuracy 303 453 603 303 453 603 303 453 603 303 453 603 VS
Swing Completion Position Repeatability 0.5 VT
F F1 F2 382
Double Action Swing Clamp m od e l LHA
Blan k
Applicable Model Blan k
C A
LLever Length (mm) R D
L HA 0 - G
L M - F
S Q
N
Y
1 Body Size 6 Option
F Clamping Force (kN) Blank/A/F/Q/Y
s
PHydraulic Pressure (MPa) (Ex.) When using LHA0480, Supply Hydraulic Pressure 5.0 MPa, Lever Length L=50mm,
Clamping force is about 3.1 kN.
7 3.50 3.0 2.9 2.8 2.7 2.6 2.4 2.2 124 L=100(s=77.5)
6.5 3.25 2.7 2.7 2.6 2.5 2.4 2.2 2.1 144
6 3.00 2.5 2.5 2.4 2.3 2.2 2.1 1.9 1.7 171 2 L=150(s=127.5)
5.5 2.75 2.3 2.3 2.2 2.1 2.0 1.9 1.8 1.6 210
5 2.50 2.1 2.1 2.0 1.9 1.9 1.7 1.6 1.5 210 1.5
4.5 2.25 1.9 1.9 1.8 1.7 1.7 1.6 1.5 1.3 210
4 2.00 1.7 1.7 1.6 1.5 1.5 1.4 1.3 1.2 210
1
3.5 1.75 1.5 1.4 1.4 1.4 1.3 1.2 1.1 1.0 210 Non-Usable Range ()
3 1.50 1.3 1.2 1.2 1.2 1.1 1.1 1.0 0.9 210
2.5 1.25 1.1 1.0 1.0 1.0 0.9 0.9 0.8 0.8 210 0.5
2 1.00 0.9 0.8 0.8 0.8 0.8 0.7 0.7 0.6 210
1.5 0.75 0.7 0.6 0.6 0.6 0.6 0.6 0.5 0.5 210 0
Max. Operating Pressure (MPa) 7.0 7.0 7.0 7.0 7.0 7.0 7.0 6.4 0 1 2 3 4 5 6 7
Supply Hydraulic Pressure (MPa)
5
Cylinder Force
LHA0480 Clamping Force Calculation Formula 1 (kN) F = P(1-0.0009L) ( 1.4892+0.0018L)
L=50(s=24.5)
Hydraulic Cylinder Force Clamping Force (kN) Non-Usable Range() Max. Lever
Pressure (kN) Lever Length L (mm) Length (L) 4 L=80(s=54.5)
(MPa) L=50 L=60 L=80 L=100 L=120 L=140 L=160 L=200 (mm)
L=140(s=114.5)
Clamping Force (kN)
383
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Series
Pneumatic Series
Notes :
1. Tables and graphs shown are the relationships between the clamping force (kN) and supply hydraulic pressure (MPa).
Hydraulic Series
2. Cylinder force (when L=0) cannot be calculated from the calculation formula of clamping force.
3. There may be no lever swing action with large inertia depending on supply hydraulic pressure or lever mounting position. Valve / Coupler
4. Clamping force indicates the value when the lever locks a workpiece in horizontal position. Hydraulic Unit
5. The clamping force varies depending on the lever length. Set the supply hydraulic pressure suitable to the lever length. Manual Operation
6. Using in the non-usable range may damage the clamp and lead to fluid leakage. Accessories
7. The tables and graphs are only for reference. The exact results should be calculated based on the clamping force calculation formula.
Cautions / Others
1. FClamping Force (kN), PSupply Hydraulic Pressure (MPa), LLever Length (mm).
10
LHA0650 Clamping Force Calculation Formula 1 (kN) F = P(1-0.0009L) ( 0.7822+0.0010L) Cylinder Force
Hole Clamp
9 SFA
Hydraulic Cylinder Force Clamping Force (kN) Non-Usable Range() Max. Lever
8 L=50(s=15) SFC
Pressure (kN) Lever Length L (mm) Length (L)
(MPa) L=50 L=60 L=80 L=100 L=120 L=140 L=160 L=200 (mm) L=80(s=45)
7 Swing Clamp
Work Support
7 14.21 12.4 12.2 11.7 11.3 10.9 10.5 147 10
6.5 13.19 11.5 11.3 10.9 10.5 10.2 9.8 9.5 163 L=200(s=160) LD
6 12.18 10.6 10.4 10.1 9.7 9.4 9.0 8.7 184 8 LC
5.5 11.16 9.7 9.6 9.2 8.9 8.6 8.3 8.0 7.5 209 T NC
5 10.15 8.9 8.7 8.4 8.1 7.8 7.5 7.3 6.8 244
6 TC
4.5 9.13 8.0 7.8 7.6 7.3 7.0 6.8 6.6 6.1 280
4 8.12 7.1 7.0 6.7 6.5 6.3 6.0 5.8 5.4 280 Air Sensing
3.5 7.10 6.2 6.1 5.9 5.7 5.5 5.3 5.1 4.8 280 4 Non-Usable Range () Lift Cylinder
3 6.09 5.3 5.2 5.1 4.9 4.7 4.5 4.4 4.1 280 LLW
2.5 5.07 4.5 4.4 4.2 4.1 3.9 3.8 3.7 3.4 280 2
2 4.06 3.6 3.5 3.4 3.3 3.2 3.0 2.9 2.7 280 Compact Cylinder
1.5 3.04 2.7 2.6 2.5 2.5 2.4 2.3 2.2 2.1 280 0 LL
Max. Operating Pressure (MPa) 7.0 7.0 7.0 7.0 7.0 7.0 6.9 5.9 0 1 2 3 4 5 6 7 LLR
Supply Hydraulic Pressure (MPa) LLU
DP
LHA0900 Clamping Force Calculation Formula 1 (kN) F = P(1-0.0009L) ( 0.3547+0.0004L) Cylinder Force DR
20
Hydraulic Cylinder Force Clamping Force (kN) Non-Usable Range() Max. Lever DS
Pressure (kN) Lever Length L (mm) Length (L) L=60(s=12.5) DT
(MPa) L=60 L=75 L=100 L=120 L=140 L=170 L=200 L=250 (mm) 16 L=100(s=52.5)
Clamping Force (kN)
7 20.62 17.5 17.0 16.2 15.6 14.9 14.1 13.3 245 Block Cylinder
L=170(s=122.5)
6.5 19.15 16.3 15.8 15.0 14.4 13.9 13.1 12.3 11.1 292 DBA
6 17.68 15.0 14.6 13.9 13.3 12.8 12.1 11.4 10.3 330 12 L=250(s=202.5) DBC
5.5 16.20 13.8 13.4 12.7 12.2 11.7 11.1 10.4 9.4 330
5 14.73 12.5 12.2 11.6 11.1 10.7 10.1 9.5 8.6 330
Centering Vise
4.5 13.26 11.3 11.0 10.4 10.0 9.6 9.1 8.5 7.7 330 8
4 11.78 10.0 9.7 9.3 8.9 8.6 8.1 7.6 6.9 330 FVA
Non-Usable Range ()
3.5 10.31 8.8 8.5 8.1 7.8 7.5 7.1 6.6 6.0 330 FVD
3 8.84 7.5 7.3 7.0 6.7 6.4 6.1 5.7 5.2 330 4 FVC
2.5 7.37 6.3 6.1 5.8 5.6 5.4 5.1 4.8 4.3 330
2 5.89 5.0 4.9 4.7 4.5 4.3 4.1 3.8 3.5 330 Control Valve
1.5 4.42 3.8 3.7 3.5 3.4 3.2 3.1 2.9 2.6 330 0 BZL
Max. Operating Pressure (MPa) 7.0 7.0 7.0 7.0 7.0 7.0 7.0 6.8 0 1 2 3 4 5 6 7 BZT
Supply Hydraulic Pressure (MPa) BZX/JZG
30
Cylinder Force Pallet Clamp
LHA1050 Clamping Force Calculation Formula 1 (kN) F = P(1-0.0008L) ( 0.2495+0.0002L)
VS
Hydraulic Cylinder Force Clamping Force (kN) Non-Usable Range() Max. Lever 25 L=80(s=25) VT
Pressure (kN) Lever Length L (mm) Length (L) L=120(s=65)
(MPa) L=80 L=100 L=120 L=140 L=170 L=200 L=250 L=300 (mm) Expansion Locating Pin
Clamping Force (kN)
384
Double Action Swing Clamp m od e l LHA
LHA0360 Allowable Locking Time (sec) LHA0400 Allowable Locking Time (sec) LHA0480 Allowable Locking Time (sec)
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.005 0.010 0.020
Lever Inertia Moment (kgm 2 )
2 2 2
0 0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Allowable Releasing Time (sec) Allowable Releasing Time (sec) Allowable Releasing Time (sec)
LHA0550 Allowable Locking Time (sec) LHA0650 Allowable Locking Time (sec) LHA0750 Allowable Locking Time (sec)
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.030 0.08 0.12
90Swing 0.07 90Swing 90Swing
Lever Inertia Moment (kgm 2 )
0.025 0.10
0.06
0.020 0.08
0.05
LHA0900 Allowable Locking Time (sec) LHA1050 Allowable Locking Time (sec)
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.20 0.30
90Swing 90Swing
Lever Inertia Moment (kgm 2 )
0.25
0.16
0.20
0.12
0.15
Full Stroke
1
0.08 Full Stroke
1 0.10
0.04
0.05
2 2
0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Allowable Releasing Time (sec) Allowable Releasing Time (sec)
Notes
1. It shows the inertia moment with material lever (LZH-T).
2. For any lever inertia moment, minimum 90swing time should be 0.2 sec for locking and 0.1 sec for releasing or more.
1. For LHA-QLong Stroke Model, the total operation time is different from what is shown in the graph. It should be calculated with
the calculation formula. (90swing time is as shown in the graph.)
2. The graph shows the allowable action time with respect to the lever inertia moment when the piston rod operates at constant speed.
3. There may be no lever swing action with large inertia depending on supply hydraulic pressure, oil flow and lever mounting position.
4. For speed adjustment of clamp lever, please use meter-out flow control valve.
In case of meter-in control, the clamp lever may be accelerated by its own weight during swinging motion (clamp mounted
horizontally) or the piston rod may be moving too fast. Please refer to P.1238 for speed control of the hydraulic cylinder.
5. Excessive swing speed can reduce stopping accuracy and damage the internal parts.
6. Please contact us if operational conditions differ from those shown on the graphs.
385
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Series
Swing Clamp
L HA
LHC
LHS
LHW
H ow t o Calcula t e Iner t ia M o m ent ( E s t im at e d ) LT /LG
T LA - 2
T LB- 2
Inertia Moment (kgm 2 ) L,L 1 ,L 2 ,K,bLength (m) m,m 1 ,m 2 ,m 3Mass (kg) T LA - 1
Link Clamp
LK A
For a rectangular plate (cuboid), For a rectangular plate (cuboid), Load is applied on the lever front end. LK C
LK W
the rotating shaft is vertically on the rotating shaft is vertically on
K L2 LM/LJ
one side of the plate. the gravity center of the plate. b T MA - 2
L b b L T MA - 1
L1 L L1 Work Support
LD
m3 LC
m1 m m2 m1
m2 T NC
TC
Air Sensing
Lift Cylinder
LLW
Block Cylinder
DBA
Calculation Formula of Total Operation Time
DBC
Centering Vise
FVA
FVD
Full Stroke (mm) FVC
Total Lock Operation Time (sec) = 90Swing Time when Locking (sec)
Swing Stroke (mm) Control Valve
BZL
BZT
BZX/JZG
386
Double Action Swing Clamp Standard Model m od e l LHA
Ny 6 Ny 6
Release PortG Thread 3 JA B
(Only for -C option H J
Speed Control Valve Port)
Z
2-
Hexagon Socket Y R Type
Lock PortP 6
JB
4-EA Screw 4 K
CA - 0.05
Swing Direction
K
AA
0
C
when Clamping
L
+ 0.3
L Type Remove all burrs6 D 0
4-R
2-G Thread (Included) 6.3S 6 C0.6
Spot Facing Q
(-C option only)
+0.05
CC 0 Slot for Lever Phasing 1
Lock PortG Thread 3
R type (L type180Reverse)
(Only for -C option
Speed Control Valve Port) 5
CB
Taper 1/10
BA
V
Notes
4. EA tapping depth of the mounting bolt should be decided
Taper Sleeve (Included)
Fu
S 2
A
M
E
F
Piping Method
GGasket Option (with R Thread Plug)
The drawing shows the released state of LHA-GR.
-0.1
D -0.2 max.2mm
2-R Thread Plug (Included)
Nx
Lock Port
Notes
Rc Thread
1. The slot for lever phasing faces the port side when locked.
2. Mounting bolts are not provided. Please prepare them
according to the mounting height referring to dimension 'S'.
3. Speed control valve is sold separately. Please refer to P.891.
387
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
Swing Clamp
L HA
LHC
External Dimensions and Machining Dimensions for Mounting (mm) LHS
Model No. LHA0360- LHA0400- LHA0480- LHA0550- LHA0650- LHA0750- LHA0900- LHA1050- LHW
LT /LG
Full Stroke 13.5 14.5 15.5 18.5 20 24 26 32
T LA - 2
Swing Stroke (90
) 5.5 6.5 7.5 8.5 10 12 14 16 T LB- 2
Vertical Stroke 8 8 8 10 10 12 12 16 T LA - 1
A 104 115 128.5 145.5 156 181 203 240
Link Clamp
B 49 54 61 69 81 92 107 122 LK A
C 40 45 51 60 70 80 95 110 LK C
D 36 40 48 55 65 75 90 105 LK W
LM/LJ
E 64.5 71.5 79 89 94 109 120 144
T MA - 2
F 39.5 46.5 51 59 63 71 74 88 T MA - 1
Fu 64.5 68.5 77.5 86.5 93 110 129 152
Work Support
G 25 25 28 30 31 38 46 56
LD
H 29 31.5 35.5 39 46 52 59.5 67 LC
J 20 22.5 25.5 30 35 40 47.5 55 T NC
K 31.4 34 40 47 55 63 75 88 TC
Air Sensing
L 66 73 83 88 106 116 136 152 Lift Cylinder
M 11 11 13 12 13 16 19 22 LLW
Nx 23.5 26 30 33.5 39.5 45 52.5 60
Compact Cylinder
Ny 8 9 11 12 15 16 18.5 22.5 LL
P 3 3 3 3 5 5 5 5 LLR
X (Nominal Pitch) M141.5 M161.5 M201.5 M221.5 M271.5 M301.5 M391.5 M481.5
Centering Vise
Y 5 6 8 8 10 10 14 14 FVA
Z (Chamfer) C2 C3 C3 C3 C4 C5 C6 C6 FVD
AA 22 24 30 32 41 46 55 65 FVC
AB 7 8 9 10 11 11 12 12 Control Valve
AC 24.5 26.5 33 35.5 45 50 60 71 BZL
BA 14 16 19 22 25 31 38 44 BZT
BZX/JZG
BB 17 20 25 28 34 40 49 60
CA 6 7 9 10 12.5 14 18.5 23 Pallet Clamp
VS
CB 6.5 6.5 7.5 9.5 11.5 12.5 11.5 13.5
VT
CC 4 4 5 6 6 8 8 10
Expansion Locating Pin
EA (Nominal Pitch) M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5 M121.75
VFL
JA 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5
VFM
JB 14 14 14 14 19 19 22 22 VFJ
Lock Port / -C option G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 G3/8 G3/8 VFK
Release Port -S option Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 Rc3/8
Pull Stud Clamp
R-Thread Plug -G option R1/8 R1/8 R1/8 R1/8 R1/4 R1/4 R3/8 R3/8
FP
O-ring (-C/-G option) 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7 FQ
Cylinder Capacity Lock 4.8 7.3 10.8 19 26.7 48.7 76.6 132.1 Customized
Spring Cylinder
cm3 Release 7.2 10.9 16.7 28.1 40. 9 72.5 117.9 208.1
7 DW A /DW B
Mass kg 0.7 0.9 1.4 2 2.9 4.2 7.2 10.1
Note7. Mass of single swing clamp including taper sleeve and nut.
388
Double Action Swing Clamp Double End Rod Option for Dog model LH A-D
5
Ny Ny
Release PortG Thread 3 JA B
5
(Only for -C option H J
Speed Control Valve Port)
Z
2-
Hexagon Socket Y R type
Lock PortP 5
JB
4-EA Screw 4 K
CA - 0.05
Swing Direction
K
AA
0
C
when Clamping
L
CB
BA
V
Notes
Taper Sleeve (Included) 4. EA tapping depth of the mounting bolt should be decided
Fu
BB
T
S2
M
A
D -0.1
E
-0.2
F
DA
Piping Method
GGasket Option (with R Thread Plug)
DC
max.2mm
Full Stroke
DD
Nx DE Screw
DF
Release Port
Rc Thread
Release Port : O-ring (Included)
(-C/-G option)
Notes
Lock Port
1. The slot for lever phasing faces the port side when locked.
Rc Thread
2. Mounting bolts are not provided. Please prepare them
according to the mounting height referring to dimension 'S'.
3. Speed control valve is sold separately. Please refer to P.891.
1. Please contact us if it has a combination with other detection
methods and/or options.
389
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
1 Body size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
Swing Clamp
L HA
LHC
External Dimensions and Machining Dimensions for Mounting (mm) LHS
Model No. LHA0360-D LHA0400-D LHA0480-D LHA0550-D LHA0650-D LHA0750-D LHA0900-D LHA1050-D LHW
Full Stroke 13.5 14.5 15.5 18.5 20 24 26 32 LT /LG
Swing Stroke(90 5.5 6.5 7.5 8.5 10 12 14 16 T LA - 2
Vertical Stroke 8 8 8 10 10 12 12 16 T LB- 2
A 114.5 128 141.5 158.5 169 194 216 253 T LA - 1
B 49 54 61 69 81 92 107 122
C 40 45 51 60 70 80 95 110 Link Clamp
D 36 40 48 55 65 75 90 105 LK A
E 67 74.5 82 92 97 112 123 147 LK C
F 42 49.5 54 62 66 74 77 91 LK W
Fu 64.5 68.5 77.5 86.5 93 110 129 152 LM/LJ
G 25 25 28 30 31 38 46 56
T MA - 2
H 29 31.5 35.5 39 46 52 59.5 67
T MA - 1
J 20 22.5 25.5 30 35 40 47.5 55
K 31.4 34 40 47 55 63 75 88 Work Support
L 66 73 83 88 106 116 136 152 LD
M 11 11 13 12 13 16 19 22 LC
Nx 23.5 26 30 33.5 39.5 45 52.5 60
T NC
Ny 8 9 11 12 15 16 18.5 22.5
TC
P 3 3 3 3 5 5 5 5
Air Sensing
Q 7.5 9 9 11 11 14 17.5 20
Lift Cylinder
R 4.5 5.5 5.5 6.8 6.8 9 11 14
LLW
S 16 15 17.5 17 17 21 25 32
T 15.5 16.5 17.5 20.5 22 26 28 34 Compact Cylinder
U 15 18 22 25 30 35.5 45 55
LL
V 13 15 18 21 24 30 37 43
LLR
W 11 12 14 15 16 16 18 19
LLU
X (Nominal Pitch) M141.5 M161.5 M201.5 M221.5 M271.5 M301.5 M391.5 M481.5
DP
Y 5 6 8 8 10 10 14 14
ZChamfer C2 C3 C3 C3 C4 C5 C6 C6 DR
AA 22 24 30 32 41 46 55 65 DS
AB 7 8 9 10 11 11 12 12 DT
AC 24.5 26.5 33 35.5 45 50 60 71
Block Cylinder
BA 14 16 19 22 25 31 38 44
BB 17 20 25 28 34 40 49 60 DBA
390
Double Action Swing Clamp Air Sensing Manifold Option m od e l LH A-M
7
Ny
(Only for -C option H J
Speed Control Valve Port)
7
Z
Ny
2-
Hexagon Socket Y R type
Lock PortP7
JB
CA -0.05
Swing Direction
K
AA
0
C
6 MF 0.2
(Only for -C option
6 MD 0.4
Speed Control Valve Port)
30
6 ME 0.4
or more
Nut (Included) AC X Screw MAH8
6.3
6.3S
30
MM
6 ML
AB
MH MJ MH MG
6.3
W
S
Taper 1/10
CB
BA
V
6.3
S
Taper Sleeve (Included)
Fu
BB
T
2-46
MK or more
15
U 30
Remove all burrs
G
A
S2
MC
Notes
E
-0.1
prevent coolant and chips from entering the air vent port.
F
D -0.2
5. EA tapping depth of the mounting bolt should be decided
according to the mounting height referring to dimension 'S'.
6. The dimensions indicate those under the flange.
7. The machining dimension is for -C/-GGasket option.
Release Confirmation
Port (Air)
3-O-ring Piping Method
MB
Lock Confirmation
(Included)
Port (Air) GGasket Option (with R Thread Plug)
The drawing shows the released state of LHA-GRM.
max.2mm
Air Vent Port 4 MAf8 2-R Thread Plug (Included)
Nx
Lock PortO-ring (Included)
(-C/-G option)
Ny
Release Port
Release PortO-ring (Included) Rc Thread
(-C/-G option)
Notes
1. The slot for lever phasing faces the port side when locked.
2. Mounting bolts are not provided. Please prepare them Lock Port
according to the mounting height referring to dimension 'S'. Rc Thread
3. Speed control valve is sold separately. Please refer to P.891.
1. Please contact us if it has a combination with other detection
methods and/or options.
391
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
Swing Clamp
L HA
LHC
External Dimensions and Machining Dimensions for Mounting (mm) LHS
Model No. LHA0360-M LHA0400-M LHA0480-M LHA0550-M LHA0650-M LHA0750-M LHA0900-M LHA1050-M LHW
Full Stroke 13.5 14.5 15.5 18.5 20 24 26 32 LT /LG
Swing Stroke (90) 5.5 6.5 7.5 8.5 10 12 14 16 T LA - 2
Vertical Stroke 8 8 8 10 10 12 12 16 T LB- 2
A 104 115 128.5 145.5 156 181 203 240 T LA - 1
B 49 54 61 69 81 92 107 122
C 40 45 51 60 70 80 95 110 Link Clamp
D 36 40 48 55 65 75 90 105 LK A
E 64.5 71.5 79 89 94 109 120 144 LK C
F 39.5 46.5 51 59 63 71 74 88 LK W
Fu 64.5 68.5 77.5 86.5 93 110 129 152 LM/LJ
G 25 25 28 30 31 38 46 56
T MA - 2
H 29 31.5 35.5 39 46 52 59.5 67
T MA - 1
J 20 22.5 25.5 30 35 40 47.5 55
K 31.4 34 40 47 55 63 75 88 Work Support
L 66 73 83 88 106 116 136 152 LD
M 11 11 13 12 13 16 19 22 LC
Nx 23.5 26 30 33.5 39.5 45 52.5 60
T NC
Ny 8 9 11 12 15 16 18.5 22.5
TC
P 3 3 3 3 5 5 5 5
Air Sensing
Q 7.5 9 9 11 11 14 17.5 20
Lift Cylinder
R 4.5 5.5 5.5 6.8 6.8 9 11 14
LLW
S 16 15 17.5 17 17 21 25 32
T 15.5 16.5 17.5 20.5 22 26 28 34 Compact Cylinder
U 15 18 22 25 30 35.5 45 55
LL
V 13 15 18 21 24 30 37 43
LLR
W 11 12 14 15 16 16 18 19
LLU
X (Nominal Pitch) M141.5 M161.5 M201.5 M221.5 M271.5 M301.5 M391.5 M481.5
DP
Y 5 6 8 8 10 10 14 14
Z (Chamfer) C2 C3 C3 C3 C4 C5 C6 C6 DR
AA 22 24 30 32 41 46 55 65 DS
AB 7 8 9 10 11 11 12 12 DT
AC 24.5 26.5 33 35.5 45 50 60 71
Block Cylinder
BA 14 16 19 22 25 31 38 44
BB 17 20 25 28 34 40 49 60 DBA
6
Speed Control Valve Port)
Ny Ny
Z
2-
6
Hexagon Socket Y R type
JB
Lock PortP 6
CA - 0.05
Swing Direction
K
AA
0
C
when Clamping
L 4-EA Screw 5 K
L type + 0.3
Remove all burrs 6 D 0
4-R
2-G Thread (Included)
Spot Facing Q
(-C option only) 6.3S6 C0.6
+ 0.05
3 CC 0 Slot for Lever Phasing 1
Lock PortG Thread
R type (L type180Reverse)
(Only for -C option
Speed Control Valve Port)
Notes
Taper 1/10
CB
prevent coolant and chips from entering the air vent port.
BB prevent coolant and chips, but do not block the air vent hole.
T
S2
M
Piping Method
E
D -0.2
max.2mm
2-R Thread Plug (Included)
ND
Rc Thread
2-NG Screw 4
NStandard NC
Ny
45
Release PortO-ring (Included)
(-C/-G option)
NE
Notes
1. The slot for lever phasing faces the port side when locked. NL NR
2. Mounting bolts are not provided. Please prepare them
according to the mounting height referring to dimension 'S'.
3. Speed control valve is sold separately. Please refer to P.891.
1. Please contact us if it has a combination with other detection
methods and/or options.
Release Confirmation Port
Lock Confirmation Port
393
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
1 Body Size
C N Hydraulic Series
R NC
2 Design No.
L NL Hydraulic Unit
S NR
4 Swing Direction when Clamping Manual Operation
Accessories
5 Action Confirmation (When N is chosen)
1 2 3 4 5 Cautions / Others
6 Option (When Blank is chosen)
Hole Clamp
SFA
SFC
Swing Clamp
L HA
394
Double Action Swing Clamp Quick Change Lever Type A m od e l LHA-A
Z
2-
R Type
2-Slot for Lever Phasing
CA
JB
Swing Direction
Machining Dimensions of Mounting Area
K
C
When Clamping
CA
L
Nx6
-G Thread Plug (Included) Release PortP6
(Only for -C Option) L Type
6
Spot FacingQ
Ny Ny
(Only for -C option
6
Speed Control Valve Port) Swing Lever 2-Slot for Lever Phasing 1
(Prepared by Customer)
Tightening Kit
Lock Port P6
Pin for Stopper and Phasing LZH-W (Sold Separately)
CC
(Prepared by Customer)
4-EA Screw4 K
CB
+0.3
SA
6.3S6 C0.6
U
Fu
SB
15
5
G
S2
A
M
E
Notes
F
Piping Method
Nx GGasket Option (With R Thread Plug)
The drawing shows the released state of LHA-GR-A.
Lock PortO-ring (Included)
(-C/-G option) max.2mm
2-R Thread Plug (Included)
Ny
Ny
Release Port
Rc Thread
Notes
2. Mounting bolts are not provided. Please prepare them
according to the mounting height referring to dimension 'S'.
3. Speed control valve is sold separately. Please refer to P.891.
1. Please contact us if it has a combination with other detection
methods and/or options. Lock Port
Rc Thread
395
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
Swing Clamp
L HA
LHC
External Dimensions and Machining Dimensions for Mounting
(mm) LHS
Model No. LHA0360--A LHA0400--A LHA0480--A LHA0550--A LHA0650--A LHA0750--A LHA0900--A LHA1050--A LHW
LT /LG
Full Stroke 13.5 14.5 15.5 18.5 20 24 26 32
T LA - 2
Swing Stroke (90
) 5.5 6.5 7.5 8.5 10 12 14 16 T LB- 2
Vertical Stroke 8 8 8 10 10 12 12 16 T LA - 1
A 104 115 128.5 145.5 156 181 203 240 Link Clamp
B 49 54 61 69 81 92 107 122 LK A
C 40 45 51 60 70 80 95 110 LK C
D 36 40 48 55 65 75 90 105 LK W
LM/LJ
E 64.5 71.5 79 89 94 109 120 144
T MA - 2
F 39.5 46.5 51 59 63 71 74 88 T MA - 1
Fu 64.5 68.5 77.5 86.5 93 110 129 152
Work Support
G 25 25 28 30 31 38 46 56 LD
H 29 31.5 35.5 39 46 52 59.5 67 LC
J 20 22.5 25.5 30 35 40 47.5 55 T NC
TC
K 31.4 34 40 47 55 63 75 88
Air Sensing
L 66 73 83 88 106 116 136 152 Lift Cylinder
M 11 11 13 12 13 16 19 22 LLW
Nx 23.5 26 30 33.5 39.5 45 52.5 60 Compact Cylinder
Ny 8 9 11 12 15 16 18.5 22.5 LL
P 3 3 3 3 5 5 5 5 LLR
CC 3 + 0.028
+ 0.014 4 + 0.038
+ 0.020 4 + 0.038
+ 0.020 4 + 0.038
+ 0.020 6 + 0.038
+ 0.020 6 + 0.038
+ 0.020 8 + 0.047
+ 0.025 8 + 0.047
+ 0.025
Centering Vise
EA (NominalPitch) M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5 M121.75 FVA
SA 24 27 32 36 40 46 55 62 FVD
SB 15.5 16.5 17.5 20.5 22 26 28 34 FVC
SC (NominalPitchDepth) M40.77 M50.88 M50.88 M6111 M6111 M81.2513 M101.515 M101.515 Control Valve
JA 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5 BZL
JB BZT
14 14 14 14 19 19 22 22
BZX/JZG
Lock port/ -C option G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 G3/8 G3/8
Release Port -S option Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 Rc3/8 Pallet Clamp
VS
R Thread Plug -G option R1/8 R1/8 R1/8 R1/8 R1/4 R1/4 R3/8 R3/8
VT
O-ring (-C/-G option) 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7
Expansion Locating Pin
Pin for Stopper and Phasing 3(m6)8 4(m6)10 4(m6)12 4(m6)14 6(m6)14 6(m6)16 8(m6)20 8(m6)22
VFL
Cylinder Capacity Lock 4.8 7.3 10.8 19 26.7 48.7 76.6 132.1
VFM
cm3 Release 7.2 10.9 16.7 28.1 40.9 72.5 117.9 208.1 VFJ
Mass 7 kg 0.7 0.9 1.3 1.9 2.8 4 7 9.8 VFK
Note 7. Mass of single swing clamp without the tightening kit and swing lever. Pull Stud Clamp
FP
FQ
Customized
Spring Cylinder
DW A /DW B
396
Double Action Swing Clamp Quick Change Lever Type F m od e l LHA-F
Z
2-
CA R type
2-Slot for Lever Phasing
JB
CA
K
C
When Clamping
L Nx6
Release PortP 6
L type
4-R
6
-G Thread Plug (Included)
Ny Ny
(Only for -C Option) Spot Facing Q
6
Lock PortG Thread 3 2-Slot for Lever Phasing 1
(Only for -C option
Speed Control Valve Port) Lock PortP 6
FA
CCH8
4-EA Screw4 K
CB
FB
+0.3
Remove all burrs6 D 0
6.3S6 C0.6
FC
U
Fu
15
5
G
S2
A
M
E
Notes
F
Piping Method
GGasket Option (with R Thread Plug)
Nx
The drawing shows the released state of LHA-GR-F.
Lock PortO-ring (Included)
max.2mm
(-C/-G option) 2-R Thread Plug (Included)
Ny
Ny
Release Port
Rc Thread
Notes
2. Mounting bolts are not provided. Please prepare them
according to the mounting height referring to dimension 'S'.
3. Speed control valve is sold separately. Please refer to P.891.
1. Please contact us if it has a combination with other detection Lock Port
methods and/or options. Rc Thread
397
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
Swing Clamp
L HA
LHC
External Dimensions and Machining Dimensions for Mounting
(mm) LHS
Model No. LHA0360--F LHA0400--F LHA0480--F LHA0550--F LHA0650--F LHA0750--F LHA0900--F LHA1050--F LHW
LT /LG
Full Stroke 13.5 14.5 15.5 18.5 20 24 26 32
T LA - 2
Swing Stroke (90
) 5.5 6.5 7.5 8.5 10 12 14 16 T LB- 2
Vertical Stroke 8 8 8 10 10 12 12 16 T LA - 1
A 102 113 126.5 143.5 156 181 203 238 Link Clamp
B 49 54 61 69 81 92 107 122 LK A
C 40 45 51 60 70 80 95 110 LK C
D 36 40 48 55 65 75 90 105 LK W
LM/LJ
E 64.5 71.5 79 89 94 109 120 144
T MA - 2
F 39.5 46.5 51 59 63 71 74 88 T MA - 1
Fu 62.5 66.5 75.5 84.5 93 110 129 150
Work Support
G 25 25 28 30 31 38 46 56 LD
H 29 31.5 35.5 39 46 52 59.5 67 LC
J 20 22.5 25.5 30 35 40 47.5 55 T NC
K TC
31.4 34 40 47 55 63 75 88
Air Sensing
L 66 73 83 88 106 116 136 152 Lift Cylinder
M 11 11 13 12 13 16 19 22 LLW
Nx 23.5 26 30 33.5 39.5 45 52.5 60 Compact Cylinder
Ny 8 9 11 12 15 16 18.5 22.5 LL
P 3 3 3 3 5 5 5 5 LLR
CC 3 + 0.014
0 4 + 0.018
0 4 + 0.018
0 4 + 0.018
0 6 + 0.018
0 6 + 0.018
0 8 + 0.022
0 8 + 0.022
0
Centering Vise
EA (Nominal Pitch) M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5 M121.75 FVA
FA 13.5 16 19.5 22 26 31 39.5 48 FVD
FB 11 12.5 15 17 20 23 27.5 30 FVC
JB BZT
14 14 14 14 19 19 22 22
BZX/JZG
Lock Port/ -C option G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 G3/8 G3/8
Release Port -S option Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 Rc3/8 Pallet Clamp
VS
R-Thread Plug -G option R1/8 R1/8 R1/8 R1/8 R1/4 R1/4 R3/8 R3/8
VT
O-ring (-C/-G option) 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7
Expansion Locating Pin
Cylinder Capacity Lock 4.8 7.3 10.8 19 26.7 48.7 76.6 132.1
cm3 Release VFL
7.2 10.9 16.7 28.1 40.9 72.5 117.9 208.1
VFM
Mass 7 kg 0.7 0.9 1.3 1.9 2.8 4 7 9.8 VFJ
VFK
Note 7. Mass of single swing clamp.
Pull Stud Clamp
FP
FQ
Customized
Spring Cylinder
DW A /DW B
398
Double Action Swing Clamp Balance Lever Option model LH A-P
6
B
Ny Ny
(Only for -C option H J
6
Speed Control Valve Port)
Z
2-
R type
Lock PortP 6
JB
-0.2
Swing Direction
-0.1
K
4-EA Screw 4 K
C
when Clamping
PA
L
L type +0.3
Remove all burrs 6 D 0
PCH8
PD
PE
PF
Notes
R0.8 4. EA tapping depth of the mounting bolt should be
decided according to the mounting height referring
to dimension 'S'.
Fu
PG
30
5. The depth of the body mounting hole D should be
15 decided according to the mounting height referring
U to dimension 'F'.
G
Lever
F
-0.1
D -0.2
Nx Piping Method
Lock PortO-ring (Included) GGasket Option (with R Thread Plug)
(-C/-G option) The drawing shows the released state of LHA-G-P.
max.2mm
2-R Thread Plug (Included)
Ny
Ny
High-Power
Model No. Indication Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
Swing Clamp
L HA
Model No. LHA0360--P LHA0400--P LHA0480--P LHA0550--P LHA0650--P LHA0750--P LHA0900--P LHA1050--P LHW
LT /LG
Full Stroke 13.5 14.5 15.5 18.5 20 24 26 32
T LA - 2
Swing Stroke(90
) 5.5 6.5 7.5 8.5 10 12 14 16 T LB- 2
Vertical Stroke 8 8 8 10 10 12 12 16 T LA - 1
A 102 113 126.5 143.5 156 181 203 238 Link Clamp
B 49 54 61 69 81 92 107 122 LK A
C 40 45 51 60 70 80 95 110 LK C
D 36 40 48 55 65 75 90 105 LK W
LM/LJ
E 64.5 71.5 79 89 94 109 120 144
T MA - 2
F 39.5 46.5 51 59 63 71 74 88 T MA - 1
Fu 62.5 66.5 75.5 84.5 93 110 129 150
Work Support
G 25 25 28 30 31 38 46 56
LD
H 29 31.5 35.5 39 46 52 59.5 67 LC
J 20 22.5 25.5 30 35 40 47.5 55 T NC
K TC
31.4 34 40 47 55 63 75 88
Air Sensing
L 66 73 83 88 106 116 136 152 Lift Cylinder
M 11 11 13 12 13 16 19 22 LLW
Nx 23.5 26 30 33.5 39.5 45 52.5 60
Compact Cylinder
Ny 8 9 11 12 15 16 18.5 22.5 LL
P 3 3 3 3 5 5 5 5 LLR
PB 13.5 16 20 23 28 33.5 43 53
Centering Vise
+ 0.018 + 0.018 + 0.022 + 0.022 + 0.027 + 0.027 + 0.027 + 0.033
PC 6 0 6 0 8 0 10 0 13 0 13 0 16 0 20 0
FVA
PD 9 11 12 12.5 16.5 19 23.5 25.5 FVD
PE 21 24 27.5 31.5 38.5 43.5 52.5 58.5 FVC
PF 22 25 29 33 40 45 54 60 Control Valve
PG 15.5 16.5 18.5 21.5 22 27 29 34 BZL
PH (Nominal Pitch) M30.5 M30.5 M40.7 M50.8 M61 M61 M81.25 M81.25 BZT
BZX/JZG
JA 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5
JB 14 14 14 14 19 19 22 22 Pallet Clamp
VS
Lock Port/ -C option G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 G3/8 G3/8
VT
Release Port -S option Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 Rc3/8
Expansion Locating Pin
R-Thread Plug -G option R1/8 R1/8 R1/8 R1/8 R1/4 R1/4 R3/8 R3/8
VFL
O-ring (-C/-G option) 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7
VFM
Cylinder Capacity Lock 4.8 7.3 10.8 19 26.7 48.7 76.6 132.1 VFJ
cm3 Release 7.2 10.9 16.7 28.1 40.9 72.5 117.9 208.1 VFK
400
Double Action Swing Clamp Long Stroke Option (/) m od e l LH A-Q
Ny 6 Ny 6
Release PortG Thread 3 JA B
(Only for -C option H J
Speed Control Valve Port)
Z
2-
Hexagon Socket Y R type
Lock PortP 6
JB
4-EA Screw4 K
CA - 0.05
Swing Direction
K
AA
0
C
when Clamping
L
+ 0.3
L type Remove all burrs6 D 0
CB
BA
V
Notes
Taper Sleeve (Included)
Fu
to dimension 'S'.
15 5. The depth of the body mounting hole D should be
U decided according to the mounting height referring
G
S 2
to dimension 'F'.
A
Piping Method
F
max.2mm
2-R Thread Plug (Included)
-0.1
D -0.2
Nx
Notes
1. The slot for lever phasing faces the port side when locked. Lock Port
Rc Thread
2. Mounting bolts are not provided. Please prepare them
according to the mounting height referring to dimension 'S'.
3. Speed control valve is sold separately. Please refer to P.891.
1. Please contact us if it has a combination with other detection
methods and/or options.
401
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
E 78.5 88.5 103.5 113.5 85.5 95.5 111.5 93 103 120 99 109 119 104 114 124 134 125 135 136 146 LK W
LM/LJ
F 53.5 63.5 78.5 88.5 60.5 70.5 86.5 65 75 92 69 79 89 73 83 93 103 87 97 90 100
T MA - 2
Fu 71.5 76.5 84 89 75.5 80.5 88.5 84.5 89.5 98 91.5 96.5 101.5 98 103 108 113 118 123 137 142
T MA - 1
G 25 25 28 30 31 38 46
Work Support
H 29 31.5 35.5 39 46 52 59.5
LD
J 20 22.5 25.5 30 35 40 47.5 LC
K 31.4 34 40 47 55 63 75 T NC
Y 5 6 8 8 10 10 14
Centering Vise
Z (Chamfer) C2 C3 C3 C3 C4 C5 C6
FVA
AA 22 24 30 32 41 46 55 FVD
AB 7 8 9 10 11 11 12 FVC
BB 17 20 25 28 34 40 49 BZT
BZX/JZG
CA 6 7 9 10 12.5 14 18.5
CB 6.5 6.5 7.5 9.5 11.5 12.5 11.5 Pallet Clamp
VS
CC 4 4 5 6 6 8 8
VT
EA M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5
Expansion Locating Pin
JA 3.5 3.5 3.5 3.5 4.5 4.5 4.5
VFL
JB 14 14 14 14 19 19 22
VFM
Lock Port/ -C option G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 G3/8 VFJ
Release Port -S option Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 VFK
R-Thread Plug -G option R1/8 R1/8 R1/8 R1/8 R1/4 R1/4 R3/8
Pull Stud Clamp
O-ring (-C/-G option) 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7
FP
Cylinder Capacity Lock 7.2 8.9 11.6 13.3 10.8 13.3 17.3 15.8 19.3 25.2 24.2 29.4 34.5 33.5 40.2 46.9 53.6 65 75.1 100.3 115.1 FQ
cm3 Release 10.9 13.5 17.5 20.2 16.2 20 26 24.2 29.6 38.7 35.7 43.3 50.9 51.1 61.3 71.5 81.7 96.6 111.7 154.2 176.9 Customized
Spring Cylinder
Mass 8 kg 0.7 0.8 1 1 1 1.1 1.3 1.6 1.7 2 2.2 2.4 2.5 3.2 3.5 3.7 4 4.8 5.2 8.3 8.8
DW A /DW B
Notes 7. Refer to P.403 when the stroke is more than that is shown in the table above.
8. Mass of single swing clamp including taper sleeve and nut.
402
Double Action Swing Clamp Long Stroke Option (/) m od e l LH A-Q
Z
2-
Hexagon Socket Y R type
Ny 6 Ny 6
JB
CA - 0.05
Swing Direction
0
K
AA
C
when Clamping
L
Lock PortO-ring (Included)6
L type
-G Thread Plug (Included) 4-R K
Spot FacingQ 4-EA Screw4
(Only for -C Option)
Lock PortG Thread 3 +0.05
0 Slot for Lever Phasing
CC 1
(Only for -C option R type (L type180Reverse) + 0.3
+ 0.1 6
Speed Control Valve Port) + 0.2 6
D 0
PB 0
X Screw
0
Nut (Included) AC
0.2 6 C0.6
1.4
AB
W
PA 6
Taper 1/10
CB
5
BA
V
BB
T
Notes
15
U 4. EA tapping depth of the mounting bolt should be decided
G
Piping Method
F
max.2mm
2-R Thread Plug(Included)
-0.1
D -0.2
Nx
Lock Port (-C/-G option)
Ny
Ny
Notes
1. The slot for lever phasing faces the port side when locked. Lock Port
Rc Thread
2. Mounting bolts are not provided. Please prepare them
according to the mounting height referring to dimension 'S'.
3. Speed control valve is sold separately. Please refer to P.891.
1. Please contact us if it has a combination with other detection
methods and/or options.
403
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Model No. Indication Series
Format ExampleLHA0550-CR-Q40LHA0750-SL-Q45
Pneumatic Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
123.5 121.5 131.5 141.5 130 140 150 136 146 156 166 176 154 164 174 184 145 155 171 181 191 156 166 182 192 202 162 172 182 192 202 212 LK W
E
LM/LJ
F 98.5 96.5 106.5 116.5 102 112 122 106 116 126 136 146 123 133 143 153 107 117 133 143 153 110 120 136 146 156 106 116 126 136 146 156
T MA - 2
Fu 94 93.5 98.5 103.5 103 108 113 110 115 120 125 130 123 128 133 138 128 133 141 146 151 147 152 160 165 170 161 166 171 176 181 186 T MA - 1
G 25 25 28 30 31 38 46 56
Work Support
H 29 31.5 35.5 39 46 52 59.5 67
LD
J 20 22.5 25.5 30 35 40 47.5 55 LC
K 31.4 34 40 47 55 63 75 88 T NC
TC
L 66 73 83 88 106 116 136 152
Air Sensing
M 11 11 13 12 13 16 19 22 Lift Cylinder
Nx 23.5 26 30 33.5 39.5 45 52.5 60 LLW
Ny 8 9 11 12 15 16 18.5 22.5
Compact Cylinder
PA 3 3 3 3 5 5 5 5 LL
PB 8 8 8 8 10 10 10 10 LLR
X (Nominal Pitch) M141.5 M161.5 M201.5 M221.5 M271.5 M301.5 M391.5 M481.5
Centering Vise
Y 5 6 8 8 10 10 14 14 FVA
Z (Chamfer) C2 C3 C3 C3 C4 C5 C6 C6 FVD
AA 22 24 30 32 41 46 55 65 FVC
AB 7 8 9 10 11 11 12 12 Control Valve
AC 24.5 26.5 33 35.5 45 50 60 71 BZL
BZT
BA 14 16 19 22 25 31 38 44
BZX/JZG
BB 17 20 25 28 34 40 49 60
Pallet Clamp
CA 6 7 9 10 12.5 14 18.5 23
VS
CB 6.5 6.5 7.5 9.5 11.5 12.5 11.5 13.5
VT
CC 4 4 5 6 6 8 8 10
Expansion Locating Pin
EA (Nominal Pitch) M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5 M121.75
VFL
JA 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5
VFM
JB 14 14 14 14 19 19 22 22 VFJ
Lock Port/ -C option G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 G3/8 G3/8 VFK
Release Port -S option Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 Rc3/8
Pull Stud Clamp
R-Thread Plug -G option R1/8 R1/8 R1/8 R1/8 R1/4 R1/4 R3/8 R3/8
FP
O-ring (-C/-G option) 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7 FQ
Cylinder Capacity Lock 15.1 19.8 22.3 24.8 28.7 32 35.7 43.3 48.4 53.6 58.7 63.9 67 73.7 80.4 87.1 85.3 95.4 111.7 121.8 132 129.8 144.4 168.2 182.9 197.7 169.3 190 210.6 231.3 251.9 272.6 Customized
Spring Cylinder
cm3 Release 22.8 29.8 33.6 37.4 44.1 49.5 54.8 63.9 71.5 79.1 86.7 94.3 102.1 112.3 122.6 132.7 126.8 141.9 166 181.1 196.2 199.6 222.3 258.6 281.3 303.9 266.7 299.2 331.7 364.2 396.7 429.3
DW A /DW B
Mass 8 kg 1.1 1.4 1.5 1.6 2.1 2.3 2.4 2.8 3 3.2 3.4 3.6 4.5 4.8 5 5.3 5.5 5.9 6.3 6.6 6.9 9.3 9.8 10.4 10.9 11.4 11.4 12.1 12.7 13.4 14.1 14.8
Notes 7. Refer to P.401 when the stroke is less than that is shown in the table above.
404
8. Mass of single swing clamp including taper sleeve and nut.
Double Action Swing Clamp Swing Angle Selectable Option m od e l LHA- Y
An
(Only for -C option H J
Swing
Speed Control Valve Port)
Z
2-
Lock
Hexagon Socket Y R type
Lock
Swin g
JB
ng
A
Swing Direction le
K
AA
C
when Clamping
5
-0 0
.0
L CA
L type
Ny 6 Ny 6
Speed Control Valve Port)
Lock PortP 6
W
Taper 1/10
CB
4-EA Screw4 K
BA
V
BB
+ 0.3
Remove all burrs 6 D 0
15
U 6.3S 6 C0.6
G
S 2
A
5
E
F
Notes
D
-0.1 4. EA tapping depth of the mounting bolt should be decided
-0.2
according to the mounting height referring to dimension 'S'.
5. The depth of the body mounting hole D should be decided
according to the mounting height referring to dimension 'F'.
6. The machining dimension is for -C/-GGasket Option.
Nx
Lock PortO-ring (Included)
(-C/-G option) Piping Method
GGasket Option (with R Thread Plug)
The drawing shows the released state of LHA-GR-Y45.
Ny
max.2mm
2-R Thread Plug (Included)
Ny
High-Power
Model No. Indication Series
1 Body Size
C Hydraulic Series
R 2 Design No.
L Hydraulic Unit
Hole Clamp
SFA
SFC
D 36 40 48 55 65 75 90 105 LK W
LM/LJ
E 64.5 71.5 79 89 94 109 120 144
T MA - 2
F 39.5 46.5 51 59 63 71 74 88 T MA - 1
Fu 61.9 62.5 63.2 65.5 66.3 67 74.1 75 75.8 82.7 83.6 84.6 88.3 89.5 90.6 104.7 106 107.3 122.9 124.4 125.9 144.8 146.6 148.4
Work Support
G 25 25 28 30 31 38 46 56
LD
H 29 31.5 35.5 39 46 52 59.5 67 LC
J 20 22.5 25.5 30 35 40 47.5 55 T NC
TC
K 31.4 34 40 47 55 63 75 88
Air Sensing
L 66 73 83 88 106 116 136 152 Lift Cylinder
M 11 11 13 12 13 16 19 22 LLW
Nx 23.5 26 30 33.5 39.5 45 52.5 60
Compact Cylinder
Ny 8 9 11 12 15 16 18.5 22.5 LL
P 3 3 3 3 5 5 5 5 LLR
X (Nominal Pitch) M141.5 M161.5 M201.5 M221.5 M271.5 M301.5 M391.5 M481.5
Centering Vise
Y 5 6 8 8 10 10 14 14 FVA
Z (Chamfer) C2 C3 C3 C3 C4 C5 C6 C6 FVD
AA 22 24 30 32 41 46 55 65 FVC
AB 7 8 9 10 11 11 12 12 Control Valve
AC 24.5 26.5 33 35.5 45 50 60 71 BZL
BA 14 16 19 22 25 31 38 44 BZT
BZX/JZG
BB 17 20 25 28 34 40 49 60
CA 6 7 9 10 12.5 14 18.5 23 Pallet Clamp
VS
CB 6.5 6.5 7.5 9.5 11.5 12.5 11.5 13.5
VT
CC 4 4 5 6 6 8 8 10
Expansion Locating Pin
EA (Nominal Pitch) M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5 M121.75
VFL
JA 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5
VFM
JB 14 14 14 14 19 19 22 22 VFJ
Lock Port/ -C option G1/8 G1/8 G1/8 G1/8 G1/4 G1/4 G3/8 G3/8 VFK
Release Port -S option Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 Rc3/8 Rc3/8
Pull Stud Clamp
R-Thread Plug -G option R1/8 R1/8 R1/8 R1/8 R1/4 R1/4 R3/8 R3/8
FP
O-ring (-C/-G option) 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7 FQ
Cylinder Capacity Lock 3.8 4 4.3 5.8 6.2 6.5 8.5 9.1 9.7 15.1 16.1 17.1 20.5 22.1 23.6 38 40.6 43.2 58.7 63.1 67.6 102.4 109.9 117.3 Customized
Spring Cylinder
cm3 Release 5.8 6.1 6.5 8.7 9.3 9.8 13 14 14.8 22.4 23.7 25.2 31.3 33.7 36 56.5 60.4 64.3 90.3 97.1 103.9 161.3 173 184.7
DW A /DW B
Mass 7 kg 0.7 0.9 1.4 2 2.9 4.2 7.2 10.1
Note 7. Mass of single swing clamp including taper sleeve and nut.
406
Double Action Swing Clamp Air Sensing Option model LH A-M / LH A-N
Air Sensing Option (Action Conrmation MethodMAir Sensing Manifold Option / NAir Sensing Piping Option)
Applicable Model
Action conrmation can be conducted by detecting C
L M
dierntial pressure with the air catch sensor connected L HA 480 0 - G
R N
S
to lock conrmation port and release conrmation port. 5 Action Confirmation Method
When M/N is chosen
The air catch sensor is necessary to conrm the piston rod action.
The essential condition: Air catch sensor that have a consumption rate more than 2225L/min (at 0.2 MPa) is needed.
In order to carry out stabilized detection, the number of clamps connected per one air catch sensor should be no more than 4.
The air pressure to the air catch sensor should be 0.2MPa.
Refer to the drawing below for the pneumatic circuit composition.
Release Confirmation 5m
Air vent port must be open to the atmosphere, and Before mounting MManifold Model, apply adequate
prevent coolant and chips from entering the air vent amounts of grease on O-ring of the manifold.
port. The air catch sensor can malfunction if the air The O-ring can be twisted or damaged when in a dry state.
vent port is blocked. If too much grease is applied, the air catch sensor
can malfunction due to overflow grease blocking
the detection port.
407
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Air Sensing Chart Series
Swing Stroke
Pressure when Nozzle Closed
Air Catch Sensor Manual Operation
Set Pressure (ON) Accessories
Full Stroke
Cautions / Others
Vertical Stroke
0 SFA
Notes 1 SFC
(Vertical Stroke -1.5)0.5
Swing Clamp
Confirmation Port LK A
Pressure when Nozzle Closed
BZX/JZG
0.2 0.2
Pallet Clamp
VS
When locking after released state When releasing after locked state
VT
408
Double Action Swing Clamp Lever Design Dimensions model LHA
(mm)
Corresponding Model No.3 LHA0360 LHA0400 LHA0480 LHA0550 LHA0650 LHA0750 LHA0900 LHA1050
H8 1
Pin Hole for Lever Phasing A 17 19 23 26 29 35 43 50
B 14 16 19 22 25 31 38 44
C 3 3 4 4 4 4 5 6
C0.4 H 4
+ 0.018
4
+ 0.018
5
+ 0.018
6
+ 0.018
6
+ 0.018
8
+ 0.022
8
+ 0.022
10
+ 0.022
C
0 0 0 0 0 0 0 0
Phasing Pin 2
4(h8)10 4(h8)10 5(h8)12 6(h8)14 6(h8)16 8(h8)16 8(h8)16 10(h8)20
D 1
(Reference)
R0.4
B0.1
A
Notes :
1. Swing lever should be designed with its length according to performance curve.
2. If the swing lever is not in accordance with the dimension shown above,
EH8 performance may be degraded and damage can occur.
1. The pin hole (H) for determining the lever phase should be added, if necessary.
2. Phasing pin is not included. Prepare it separately.
3. Refer to Design Dimensions of Quick Change Lever Type A for -A (Quick Change
Lever Type A).
Refer to Design Dimensions of Quick Change Lever Type F for -F (Quick Change
Lever Type F).
For -P (Balance Lever Option), it should be designed by customer.
(mm)
Corresponding Model No. B l a nk LHA0360 LHA0400 LHA0480 LHA0550 LHA0650 LHA0750 LHA0900 LHA1050
C D Corresponding Model No. --A --A --A --A --A --A --A --A
R
LHA 0 - G
L M -A A 15
+ 0.027
18
+ 0.027
22
+ 0.033
25
+ 0.033
30
+ 0.033
35.5+
0.039
45
+ 0.039
55
+ 0.046
S 0 0 0 0 0 0 0 0
N B 12 15 18 20 24 28 36 46
1 Body Size 6 Option A C 17 19 23 26 29 35 43 50
D 11 13 15.5 17 19 21 28 33
B + 00.05 E 13 16 20 23 25 29 38 45
F 12.5 15 16.5 18.5 20.5 25 31 33.5
G 2 2.5 4 4.5 6.5 6.5 9 14
H 3 4 4 4 6 6 8 8
J + 0.010
3 0
+ 0.012
4 0
+ 0.012
4 0
+ 0.012
4 0
+ 0.012
6 0
+ 0.012
6 0
+ 0.015
8 0
+ 0.015
8 0
Notes
JH7 4
1. Swing lever should be designed with its length according to performance curve.
Pin Hole for Stopper and Phasing
2. If the swing lever is not in accordance with the dimension shown above,
C0.6
performance may be degraded and damage can occur.
D0.1
H
3. Tightening Kit (LZH-W) for Quick Change Lever Type A is sold separately.
4. The pin hole for stopper and phasing (J) should be appropriately
C
machined according to the slot for lever phasing on the clamp body.
C0.6 Pin for stopper and phasing (prepared by customer) is used as phasing
AH8 when mounting the lever and as stopper when removing the lever. If you are not
using a pin for stopper and phasing, a stopper is required to remove the lever.
409
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
Quick Change Lever Type F Design Dimensions Series
J SFC
6.5 8.5 10.5 12.5 14.5 16.5 21 25
B
L
K 2 3 4 4 5 7 9 11 Swing Clamp
P
L 13.5 16 18 22 26.5 31 42 46 L HA
LHC
M M61 M81 M101.25 M121.5 M141.5 M161.5 M202 M242
K
J N + 0.2
E S LHS
0 N C0.4 C0.6 C0.6 C1 C1 C1 C1 C1 LHW
P 2 2 2 2 2 2 2 2 LT /LG
F0.1 Q 2.5 3.5 3.5 4 5.5 5.5 7.5 8 T LA - 2
D T LB- 2
R 3 4 4 4 6 6 8 8
T LA - 1
S 13.5 14 18 19.5 24.5 27.75 38 45
Link Clamp
C
Phasing Pin 6 LK A
G
A
Notes : LK W
LM/LJ
H 1. Swing lever should be designed with its length according to performance curve.
T MA - 2
2. If the swing lever is not in accordance with the dimension shown above,
T MA - 1
performance may be degraded and damage can occur.
3. Tightening Bolt (LZH-B) for Quick Change Lever is sold separately. Work Support
5. The pin hole (R) for determining the lever phase should be added, if necessary. LD
LC
6. Phasing pin is not included. Prepare it separately.
T NC
TC
Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
DP
DR
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
410
Double Action Swing Clamp Accessories model LHA
B 26 32 40 45 50 58 75 90
C 17 19 23 26 29 35 43 50
D 13 16 20 23 25 29 38 45
B
E 14 16 19 22 25 31 38 44
H
D F 17 20 25 28 34 40 49 60
A
G 15 17 21 23.5 29 33 42 51
G+0.2
0 H 13 16 20 22.5 25 29 37.5 45
C0.6
Notes :
1. Material : S50CH
R0.4 2. If necessary, the front end should be additionally machined.
C
E
3. When determining the phase, refer to taper lock lever design dimensions for
each model for the additional machining.
F 1. Refer to Accessory of Quick Change Lever Type A for -A (Quick Change Lever Type A).
Refer to Accessory of Quick Change Lever Type F for -F (Quick Change Lever Type F).
For -P (Balance Lever Option), it should be designed by customer.
LZH 048 0 - A
Model No.
-A -A -A -A -A -A -A -A
LHA0360 LHA0400 LHA0480 LHA0550 LHA0650 LHA0750 LHA0900 LHA1050
Size Design No. Corresponding Model No.
--A --A --A --A --A --A --A --A
(Refer to the table.) (Revision Number)
A 120 145 160 170 175 185 220 270
B 26 32 40 45 50 58 75 90
H + 00.05 C 17 19 23 26 29 35 43 50
D 13 16 20 23 25 29 38 45
E 13 16 20 22.5 25 29 37.5 45
F 15
+ 0.027
0 18
+ 0.027
0 22
+ 0.033
0 25
+ 0.033
0 30
+ 0.033
0 35.5+
0.039
0 45
+ 0.039
0 55
+ 0.046
0
B
H 12 15 18 20 24 28 36 46
J 11 13 15.5 17 19 21 28 33
D G0.05 K L Screw K 2 2.5 4 4.5 6.5 6.5 9 14
A L M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5 M101.5
Notes
C0.6
1. Material : S50CH
J0.1
Model No.
-W -W -W -W -W -W -W -W
Corresponding LHA0360 LHA0400 LHA0480 LHA0550 LHA0650 LHA0750 LHA0900 LHA1050
Model No. --A --A --A --A --A --A --A --A
Wedge 1 NominalPitch of
M40.7 M50.8 M50.8 M61 M61 M81.25 M101.5 M101.5
Tightening Bolt Tightening Bolt
Rod
Pin for Stopper and Phasing Wedge 2 Hex. Socket
3 4 4 5 5 6 8 8
mm
Tightening Torque
2.5 5.0 5.0 8.0 8.0 20 40 45
Nm
Swing Lever
411
Swing Clamp Index Model No. Indication Performance External Air Sensing Lever Design Cautions
Accessories
Digest Cross Section Specifications Curve Dimensions Option Dimensions P.553
High-Power
AccessoriesMaterial Swing Lever for Quick Change Lever Type F Series
(mm)
Model No. Indication LZH0360 LZH0400 LZH0480 LZH0550 LZH0650 LZH0750 LZH0900 LZH1050
Pneumatic Series
Model No.
LZH 048 0 - F
-F -F -F -F -F -F -F -F
Corresponding Model No. LHA0360 LHA0400 LHA0480 LHA0550 LHA0650 LHA0750 LHA0900 LHA1050 Hydraulic Series
Design No.
--F --F --F --F --F --F --F --F
Size
(Refer to the table.) (Revision Number) A 22 25 30 34 40 46 55 60 Valve / Coupler
B 22 26 32 36 45 53 70 82 Hydraulic Unit
M Screw C 11 12.5 15 17 20 23 27.5 30
Manual Operation
0 0 0 0 0 0 0 0
D 15
- 0.016 18
- 0.016 22
- 0.020 25
- 0.020 30
- 0.020 35.5
- 0.025 45
- 0.025 55
- 0.030 Accessories
G 11 14 17.5 20 23 26 32 39
H R5.5 R7 R8.75 R10 R11.5 R13 R16 R19.5 Hole Clamp
K
J N SFA
E J 6.5 8.5 10.5 12.5 14.5 16.5 21 25
SFC
Z K 2 3 4 4 5 7 9 11
L 13.5 16 18 22 26.5 31 42 46 Swing Clamp
F0.1
L HA
M M61 M81 M101.25 M121.5 M141.5 M161.5 M202 M242
D LHC
N C0.4 C0.6 C0.6 C1 C1 C1 C1 C1
LHS
P 2 2 2 2 2 2 2 2 LHW
C
T LA - 2
Notes :
C
T LB- 2
1. Material : S50CH T LA - 1
H
2. If necessary, the front end should be additionally machined.
Link Clamp
3. When determining the phase, refer to quick change lever design dimensions for
LK A
each model for the additional machining.
LK C
4. Tightening Bolt (LZH-B) for Quick Change Lever is sold separately.
LK W
LM/LJ
F 10 13 16 18 21 24 30 36 DP
DR
G 5 6 8 10 12 14 17 19
DS
DT
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
412
Hydraulic Swing Clamp Cautions mo d e l LHA/LHC/LHS/LHW/LT/LG/TLA-2/TLB-2/TLA-1
Cautions
Ex. 2
90
553
Swing Clamp
Cautions
Digest P.375
High-Power
Series
Pneumatic Series
554
Hydraulic Swing Clamp Cautions mo d e l LHA/LHC/LHS/LHW/LT/LG/TLA-2/TLB-2/TLA-1
Cautions
Installation Notes
When Using Taper Lock Lever When Using Quick Change Lever Type A
If the piston rod is subjected to excessive torque or shock, Pin for stopper and phasing (prepared by customer) is used
the rod or the internal mechanism may be damaged. as phasing when mounting the lever and as stopper when
Observe the following points to prevent such shock. removing the lever. If you are not using a pin for stopper and
phasing, a stopper is required to remove the lever.
Installation Procedure
Stopper example for lever removal when
With the clamp is positioned to the
not using pin for stopper and phasing.
xture, determine the lever position,
Pin for Stopper and Phasing
and temporarily tighten the nut for
xing the lever.
Wedge 1
Rod Tightening Bolt
Pin for Stopper
and Phasing Wedge 2
Swing Lever
555
Swing Clamp
Cautions
Digest P.375
High-Power
Series
Pneumatic Series
Torque values for the mounting screw are shown in the table below. Link Clamp
LK A
LK C
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
TC
Model No. Thread Size Tightening Torque (Nm) Air Sensing
LHA0360-D M40.7 3.2 Lift Cylinder
LHA0400-D M61 10 LLW
LHA0480-D M81.25 25
Compact Cylinder
LHA0550-D M81.25 25
LL
LHA0650-D M81.25 25
LLR
LHA0750-D M101.5 50
LLU
LHA0900-D M101.5 50
DP
LHA1050-D M101.5 50
DR
DS
DT
Block Cylinder
DBA
Installation Notes Hydraulic Fluid List Notes on Hydraulic Cylinder Speed Control Circuit DBC
Please refer to P.1237 for common cautions.
Notes on Handling Maintenance/Inspection Warranty
Centering Vise
FVA
FVD
FVC
Control Valve
BZL
BZT
BZX/JZG
Pallet Clamp
VS
VT
556
Cautions
Cautions
The pipeline, piping connector and xture circuits should be cleaned JX Nippon Oil & Energy Super Hyrando 32 Super Mulpus DX 32
Cosmo Oil Cosmo Hydro AW32 Cosmo New Mighty Super 32
by thorough ushing.
ExxonMobil Mobil DTE 24 Mobil DTE 24 Light
The dust and cutting chips in the circuit may lead to uid leakage
Matsumura Oil Hydol AW-32
and malfunction.
Castrol Hyspin AWS 32
There is no lter provided with Kosmek s product except for a part
Note As it may be difficult to purchase the products as shown in the table from
of valves which prevents foreign materials and contaminants from
overseas, please contact the respective manufacturer.
getting into the circuit.
1237
Installation Notes Notes on Hydraulic Cylinder
Hydraulic Fluid List Notes on Handling Maintenance/Inspection Warranty
(For Hydraulic Series) Speed Control Circuit
High-Power
Series
Pneumatic Series
Notes on Hydraulic Cylinder Speed Control Unit
Please pay attention to the cautions below. Design the hydraulic circuit for controlling the action speed of hydraulic cylinder.
Hydraulic Series
Improper circuit design may lead to malfunctions and damages. Please review the circuit design in advance. Valve / Coupler
Hydraulic Unit
Flow Control Circuit for Single Acting Cylinder In the case of meter-out circuit, the hydraulic circuit should Manual Operation
For spring return single acting cylinders, restricting ow be designed with the following points. Accessories
during release can extremely slow down or disrupt release action. Single acting components should not be used in the same
Cautions / Others
The preferred method is to control the ow during the lock action ow control circuit as the double acting components.
using a valve that has free-ow in the release direction. The release action of the single acting cylinders may become
It is also preferred to provide a ow control valve at each actuator. erratic or very slow.
Cautions
Installation Notes
(For Hydraulic Series)
Hydraulic Fluid List
Maintenance/
Inspection
Accelerated clamping speed by excessive hydraulic ow to
Warranty
the cylinder may sustain damage. In this case add ow control to
regulate ow. (Please add ow control to release ow if the
lever weight is put on at the time of release action when using Refer to the following circuit when both the single acting Company Profile
cylinder and double acting cylinder are used together. Company Profile
swing clamps.)
Separate the control circuit. Our Products
Flow Control at the Release Side
History
Index
Search by
Alphabetical Order
Sales Offices
Sequence Valve
1238
Cautions
Cautions
1It should be handled by qualied personnel. 1Removal of the Machine and Shut-o of Pressure Source
The hydraulic machine and air compressor should be handled Before the machine is removed, make sure that the
and maintained by qualied personnel. above-mentioned safety measures are in place. Shut o the
2Do not handle or remove the machine unless the safety protocols air of hydraulic source and make sure no pressure exists in
are ensured. the hydraulic and air circuit.
The machine and equipment can only be inspected or prepared Make sure there is no abnormality in the bolts and respective
when it is conrmed that the preventive devices are in place. parts before restarting.
Before the machine is removed, make sure that the above-mentioned
safety measures are in place. Shut o the air of hydraulic source 2Regularly clean the area around the piston rod and plunger.
and make sure no pressure exists in the hydraulic and air circuit. If it is used when the surface is contaminated with dirt, it may
After stopping the machine, do not remove until the temperature lead to packing seal damage, malfunctioning, uid leakage
cools down. and air leaks.
Make sure there is no abnormality in the bolts and respective parts
before restarting the machine or equipment.
1239
Installation Notes Notes on Hydraulic Cylinder
Hydraulic Fluid List Notes on Handling Maintenance/Inspection Warranty
(For Hydraulic Series) Speed Control Circuit
High-Power
Series
Pneumatic Series
Warranty
Manual Operation
2Warranty Scope Accessories
If the product is damaged or malfunctions during the warranty
Cautions / Others
period due to faulty design, materials or workmanship, we will
replace or repair the defective part at our expense.
Defects or failures caused by the following are not covered.
Cautions
Installation Notes
If the stipulated maintenance and inspection are not carried out. (For Hydraulic Series)
If the product is used while it is not suitable for use based on Hydraulic Fluid List
1240
C ont ro l Val v e
Mode l B ZL
Mode l B ZT
Mode l B ZX
Mode l JZG
G Thread Plug
Sp e e d C o n t ro l V a l ve A i r B le e d V a lv e G T h r e ad P lu g
891
Control Valve
Digest
High-Power
Series
Operating
Action Description
Pressure Range Pneumatic Series
Manual Operation
Accessories
Hole Clamp
F low C ontrol SFA
SFC
Swing Clamp
LHA
LHC
LHS
Speed Control Valve
LHW
For High Pressure LT /LG
A i r b le e d i n g i n t h e c i r c u i t i s p os s i b le T LA - 2
T LB- 2
b y loos e n i n g f low c on t r ol v alv e .
T LA - 1
Link Clamp
Mod e l BZT 35M Pa or less LK A
LK C
P.897
LK W
LM/LJ
T MA - 2
T MA - 1
Work Support
LD
LC
T NC
Air Bl e e d Val v e TC
Air bleeding in the circuit is possible by wrench. Air Sensing
Lift Cylinder
LLW
Compact Cylinder
LL
LLR
LLU
Block Cylinder
DBA
DBC
Centering Vise
FVA
FVD
FVC
G Thr e ad P l ug Control Valve
A i r b le e d i n g i n t h e c i r c u i t i s p os s i b le BZ L
BZ T
b y loos e n i n g G t h r e ad p lu g . BZ X /JZ G
Pallet Clamp
VS
VT
892
Control Valve Speed Control Valve (For Low Pressure) model BZL
B ZL 0 10 0 - B
1 2 3
1 G Thread Size
2 Design No.
0 Revision Number
3 Control Method
A B
A Meter-in
Circuit SymbolMeter-in Circuit SymbolMeter-out
B Meter-out
P1 port P1 port
Hydraulic Pressure P2 Port Hydraulic Pressure P2 Port
Supply Side Clamp Side Supply Side Clamp Side
Specifications
Model No. BZL0100-A BZL0200-A BZL0300-A BZL0100-B BZL0200-B BZL0300-B
Max. Operating Pressure MPa 7
Withstanding Pressure MPa 10.5
Control Method Meter-in Meter-out
G Thread Size G1/8A G1/4A G3/8A G1/8A G1/4A G3/8A
Cracking Pressure MPa 0.04 0.12
Max. Passage Area mm2 2.6 5.0 11.6 2.6 5.0 10.2
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32
Operating Temperature 0 70
Tightening Torque for Main Body Nm 10 25 35 10 25 35
Notes : 1. Minimum passage area when fully opened is the same as the maximum passage area in the table above.
2. It must be mounted with recommended torque. Because of the structure of the metal seal,
if mounting torque is insufficient, the flow control valve may not be able to adjust the flow rate.
3. Don t use used BZL to other clamps.
Flow control will not be made because the bottom depth difference of G thread makes metal seal insufficient.
893
Control Valve Model No. Applicable External
Specications Flow Rate Graph
Digest Indication Products Dimensions
High-Power
Applicable Products Series
DBA (Double Action) DBC (Double Action) LC (Single Action) LHA (Double Action) LHC (Double Action) LHE (Double Action) LHS (Double Action) LHW (Double Action) Pneumatic Series
Model No.
Block Cylinder Block Cylinder Work Support Swing Clamp Swing Clamp High-Power Swing Clamp Swing Clamp Swing Clamp
(DBA0250-C) (DBC0250-C) LC0262-C (LHA0360-C-) (LHC0360-C-) (LHS0360-C-) (LHW040-C-) Hydraulic Series
(DBA0320-C) (DBC0320-C) LC0302-C (LHA0400-C-) (LHC0400-C-) (LHS0400-C-) (LHW048-C-)
LC0362-C (LHA0480-C-) (LHC0480-C-) (LHS0480-C-) (LHW055-C-) Valve / Coupler
Hydraulic Unit
BZL0100-A LC0402-C- (LHA0550-C-) (LHC0550-C-) (LHS0550-C-)
LC0482-C- Manual Operation
Accessories
LC0552-C-
LC0652-C- Cautions / Others
DBA0250-C DBC0250-C LHA0360-C- LHC0360-C- LHE0300-C LHS0360-C- LHW040-C-
DBA0320-C DBC0320-C LHA0400-C- LHC0400-C- LHE0360-C LHS0400-C- LHW048-C-
Hole Clamp
BZL0100-B LHA0480-C- LHC0480-C- LHE0400-C LHS0480-C- LHW055-C-
SFA
LHA0550-C- LHC0550-C- LHE0480-C LHS0550-C-
SFC
LHE0550-C
Swing Clamp
(DBA0400-C) (DBC0400-C) LC0752-C- (LHA0650-C-) (LHC0650-C-) (LHS0650-C-) (LHW065-C-)
BZL0200-A LHA
(DBA0500-C) (DBC0500-C) LC0902-C- (LHA0750-C-) (LHS0750-C-) (LHW0751-C-) LHC
DBA0400-C DBC0400-C LHA0650-C- LHC0650-C- LHS0650-C- LHW065-C- LHS
BZL0200-B
DBA0500-C DBC0500-C LHA0750-C- LHS0750-C- LHW0751-C- LHW
LT /LG
(LHA0900-C-) (LHS0900-C-)
BZL0300-A T LA - 2
(LHA1050-C-) (LHS1050-C-)
T LB- 2
LHA0900-C- LHS0900-C- T LA - 1
BZL0300-B
LHA1050-C- LHS1050-C-
Link Clamp
LK A
LT (Single Action) LG (Single Action) LKA (Double Action) LKC (Double Action) LKE (Double Action) LKW (Double Action) LM (Single Action) LJ (Single Action) LK C
Model No.
Swing Clamp Swing Clamp Link Clamp Link Clamp High-Power Link Clamp Link Clamp Link Clamp Link Clamp LK W
LM/LJ
LT0301-C - LG0301-C- (LKA0360-C-) (LKC0400-C-) LKE0300-C (LKW040-C-) LM0300-C LJ0302-C
T MA - 2
LT036-C- LG036-C- (LKA0400-C-) (LKC0480-C-) LKE0360-C (LKW048-C-) LM0360-C LJ0362-C T MA - 1
BZL0100-A LT040-C- LG040-C- (LKA0480-C-) (LKC0550-C-) LKE0400-C (LKW055-C-) LM0400-C LJ0402-C
Work Support
LT048-C- LG048-C- (LKA0550-C-) LKE0480-C LM0480-C LJ0482-C
LD
LT055-C- LG055-C- LKE0550-C LM0550-C LJ0552-C LC
LKA0360-C- LKC0400-C- LKW040-C- T NC
894
Control Valve Speed Control Valve (For Low Pressure) model BZL
4 10 15
Fully Closed Fully Closed Fully Closed
10
2 5
5
0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6
Pressure Loss (MPa) Pressure Loss (MPa) Pressure Loss (MPa)
25 Fully Opened
6 15 20
4 10 15
Fully Closed Fully Closed
Fully Closed 10
2 5
5
0 0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6
Pressure Loss (MPa) Pressure Loss (MPa) Pressure Loss (MPa)
895
Control Valve Model No. Applicable External
Specications Flow Rate Graph
Digest Indication Products Dimensions
High-Power
External Dimensions Series
Pneumatic Series
Hydraulic Series
Adjusting Screw (Clamp/Cylinder)
M Screw
Exclusive Packing G Thread Valve / Coupler
Hydraulic Unit
(Included)
Manual Operation
Accessories
BZL000
B
-
Cautions / Others
P2 Port
Hex. Socket L Clamp Side
Hole Clamp
SFA
CLOSE OPEN J E
SFC
Hexagon K max.H D
Swing Clamp
Hexagon A max.C F
LHA
P1 Port
LHC
Hydraulic Pressure
Supply Side (mm) LHS
LHW
Model No. BZL0100- BZL0200- BZL0300-
LT /LG
A 14 18 22 T LA - 2
K 10 10 13 Work Support
0.2
L 3 3 4
max.S
min.R
LD
W
T
T NC
0.4 N 11.5 15 17.5
TC
P 8.5 111 13
Air Sensing
Q 9 11.5 13 Lift Cylinder
2. It is dangerous to air bleed during operation under high pressure. It must be done under lower pressure. Pallet Clamp
VS
(For reference: the minimum operating range of the product within the circuit.)
VT
896
Control Valve Air Bleed Valve model BZX
B ZX0 1 0
1 2
1 G Thread Size
2 Design No.
0 Revision Number
899
Control Valve
Model No. Indication Specications Applicable Products External Dimensions
Digest P.891
High-Power
Applicable Products Series
DBA (Double Action) DBC (Double Action) LC (Single Action) LHA (Double Action) LHC (Double Action) LHE (Double Action) LHS (Double Action) LHW (Double Action) Pneumatic Series
Model No.
Block Cylinder Block Cylinder Work Support Swing Clamp Swing Clamp High-Power Swing Clamp Swing Clamp Swing Clamp
DBA0250-C DBC0250-C LC0262-C LHA0360-C- LHC0360-C- LHE0300-C LHS0360-C- LHW040-C- Hydraulic Series
DBA0320-C DBC0320-C LC0302-C LHA0400-C- LHC0400-C- LHE0360-C LHS0400-C- LHW048-C-
LC0362-C LHA0480-C- LHC0480-C- LHE0400-C LHS0480-C- LHW055-C- Valve / Coupler
BZX010 Hydraulic Unit
LC0402-C- LHA0550-C- LHC0550-C- LHE0480-C LHS0550-C-
LC0482-C- LHE0550-C Manual Operation
Accessories
LC0552-C-
LC0652-C- Cautions / Others
DBA0400-C DBC0400-C LC0752-C- LHA0650-C- LHC0650-C- LHS0650-C- LHW065-C-
BZX020
DBA0500-C DBC0500-C LC0902-C- LHA0750-C- LHS0750-C- LHW0751-C-
Hole Clamp
LHA0900-C- LHS0900-C-
BZX030 SFA
LHA1050-C- LHS1050-C-
SFC
LT (Single Action) LG (Single Action) LKA (Double Action) LKC (Double Action) LKE (Double Action) LKW (Double Action) LM (Single Action) LJ (Single Action) Swing Clamp
Model No.
Swing Clamp Swing Clamp Link Clamp Link Clamp High-Power Link Clamp Link Clamp Link Clamp Link Clamp LHA
LHC
LT0301-C- LG0301-C - LKA0360-C- LKC0400-C- LKE0300-C LKW040-C- LM0300-C LJ0302-C
LHS
LT036-C- LG036-C- LKA0400-C- LKC0480-C- LKE0360-C LKW048-C- LM0360-C LJ0362-C
LHW
BZX010 LT040-C- LG040-C- LKA0480-C- LKC0550-C- LKE0400-C LKW055-C- LM0400-C LJ0402-C LT /LG
LT048-C- LG048-C- LKA0550-C- LKE0480-C LM0480-C LJ0482-C T LA - 2
B 15.5 20 24
C 19.8 20.6 20.6 Control Valve
BZL
D 9.3 10.1 10.1
BZT
E 5.5 6.3 6.3
3.6 BZ X /JZ G
G G1/8 G1/4 G3/8
Hex. Socket 3 3.8 E Pallet Clamp
Hexagon 10 D 10.5 VS
Hexagon A C VT
900
Control Valve G Thread Plug m od e l JZG
JZG0 1 0
1 2
1 G Thread Size
2 Design No.
0 Revision Number
Specifications
Model No. JZG010 JZG020 JZG030
Max. Operating Pressure MPa 35
Withstanding Pressure MPa 42
G Thread Size G1/8A G1/4A G3/8A
Usable Fluid General Hydraulic Oil Equivalent to ISO-VG-32
Operating Temperature 0 70
Tightening Torque Female Thread Side MaterialSteel 10 25 35
for Main Body Nm Female Thread Side MaterialAluminum (For LT/LM1) 8 20 28
Notes : 1. It is dangerous to have air venting operation under high pressure. It must be done under lower pressure.
(For reference : the minimum operation pressure range of the product within the circuit)
2. Refer to the machining dimensions for BZL mounting area.
1. Body material of LT/LM is aluminum alloy, so install it with the tightening torque for aluminum.
901
Control Valve
Model No. Indication Specications Applicable Products External Dimensions
Digest P.891
High-Power
Applicable Products Series
DBA (Double Action) DBC (Double Action) LC (Single Action) LHA (Double Action) LHC (Double Action) LHE (Double Action) LHS (Double Action) LHW (Double Action) Pneumatic Series
Model No.
Block Cylinder Block Cylinder Work Support Swing Clamp Swing Clamp High-Power Swing Clamp Swing Clamp Swing Clamp
DBA0250-C DBC0250-C LC0262-C LHA0360-C- LHC0360-C- LHE0300-C LHS0360-C- LHW040-C- Hydraulic Series
DBA0320-C DBC0320-C LC0302-C LHA0400-C- LHC0400-C- LHE0360-C LHS0400-C- LHW048-C-
LC0362-C LHA0480-C- LHC0480-C- LHE0400-C LHS0480-C- LHW055-C- Valve / Coupler
Hydraulic Unit
JZG010 LC0402-C- LHA0550-C- LHC0550-C- LHE0480-C LHS0550-C-
LC0482-C- LHE0550-C Manual Operation
Accessories
LC0552-C-
LC0652-C- Cautions / Others
DBA0400-C DBC0400-C LC0752-C- LHA0650-C- LHC0650-C- LHS0650-C- LHW065-C-
JZG020
DBA0500-C DBC0500-C LC0902-C- LHA0750-C- LHS0750-C- LHW0751-C-
Hole Clamp
LHA0900-C- LHS0900-C-
JZG030 SFA
LHA1050-C- LHS1050-C-
SFC
LT (Single Action) LG (Single Action) LKA (Double Action) LKC (Double Action) LKE (Double Action) LKW (Double Action) LM (Single Action) LJ (Single Action) Swing Clamp
Model No.
Swing Clamp Swing Clamp Link Clamp Link Clamp High-Power Link Clamp Link Clamp Link Clamp Link Clamp LHA
LHC
LT0301-C - LG0301-C- LKA0360-C- LKC0400-C- LKE0300-C LKW040-C- LM0300-C LJ0302-C
LHS
LT036-C- LG036-C- LKA0400-C- LKC0480-C- LKE0360-C LKW048-C- LM0360-C LJ0362-C
LHW
JZG010 LT040-C- LG040-C- LKA0480-C- LKC0550-C- LKE0400-C LKW055-C- LM0400-C LJ0402-C LT /LG
LT048-C- LG048-C- LKA0550-C- LKE0480-C LM0480-C LJ0482-C T LA - 2
Block Cylinder
DBA
DBC
Exclusive Packing
(Included) (mm) Centering Vise
Model No. JZG010 JZG020 JZG030 FVA
FVD
A 14 18 22
G Thread
FVC
B 3.5 4.5 4.5
A
C 8 9 10 Control Valve
BZL
D 5 6 8
BZT
Hex. Socket D G G1/8A G1/4A G3/8A BZ X /JZ G
Pallet Clamp
B C
VS
VT
902
Manifold Block
Mode l WH Z- M D
Mode l L ZY -M D
Mode l L Z-MS
Mode l L Z-MP
Mode l T MZ-1 M B
Mode l T MZ-2 M B
Mode l DZ-M G
Mode l DZ-M S
Manifold Block
Clamp
Workpiece
Manifold Block
Manifold Block
Fixture Base
1215
Manifold Block Manifold Block
Applicable Model/Application Examples Model No. Indication/External Dimensions
High-Power
Series
Applicable Model
Pneumatic Series
Manifold Block Model No. Corresponding Item Model No.
Hydraulic Series
L Z Y - MD
L Z - MS
T MZ - 1 MB
T MZ - 2 MB
DZ - M
DZ- C
DZ- B
LZ- S
LZ- SQ
Application Examples T NZ- S
T NZ- SQ
Work Support (LC) Application Example W NZ- SQ
Manifold
LC
JX
G-Thread Fitting
Fixture Base
DP-A DZ-MG
Fixture Base
1216
Manifold Block model WH Z -MD /LZ Y-MD /LZ -MS/LZ -M P
6.3S
Model No. Indication
WHZ 048 0 - M D
D + 0.3
0
Size Design No.
K
(Refer to (Revision Number)
B
following table)
C0.6 C0.6
Nx
H
2-O-ring
Ny Ny Z Surface (Included)
(mm)
Model No. WHZ0600-MD WHZ0320-MD WHZ0400-MD WHZ0500-MD WHZ0630-MD
Corresponding Item WCE0602 WCA0321 WCE1002 WCA0401 WCE1602 WCA0501 WCE2502 WCA0631 WCE4002
Model Number WHE0600 WHA0320 WHE1000 WHA0400 WHE1600 WHA0500 WHE2500 WHA0630 WHE4000
A 23 25 27 31 35
B 54 60 67 77 88.5
C 45 50 58 68 81
D 40 46 54 64 77
H 31.5 35 38 43 48
J 22.5 25 29 34 40.5
K 34 39 45 53 65
Nx 26 28 31 36 41
Ny 9 10 13 15 20
R 5.5 5.5 5.5 6.5 6.5
O-ring 1BP5 1BP7 1BP7 1BP7 1BP7
Mass kg 0.1 0.1 0.1 0.2 0.2
Notes : 1. MaterialA2017BE-T4
2. Mounting bolts are not provided. Prepare mounting bolts according to the mounting height using the A dimensions as a reference.
3. If thickness other than A is required, perform additional machining on surface Z. Please refer to the drawing.
B 4-K C 0.1
Manifold Block for LKA/LKC/LKE/LHA/
6.3S
J
LHC/LHE/LHS/LL
Model No. Indication
F
LZY 0 48 0 - M D
D + 0.3
0
J
following table)
2-O-ring
H L Surface (Included)
(mm)
Model No. LZY0360-MD LZY0400-MD LZY0480-MD LZY0550-MD LZY0650-MD LZY0750-MD LZY0900-MD LZY1050-MD
LKA0360 / LKE0360 LKA0400 / LKC0400 LKA0480 / LKC0480 LKA0550 / LKC0550 LKA0650 / LKC0650 LKA0750 LKA0900 LKA1050
Corresponding Item LHA0360 / LHC0360 LKE0400 / LHA0400 LKE0480 / LHA0480 LKE0550 / LHA0550 LHA0650 / LHC0650 LHA0750 LHA0900 LHA1050
Model Number LHE0360 / LHS0360 LHC0400 / LHE0400 LHC0480 / LHE0480 LHC0550 / LHE0550 LHS0650 LHS0750 LHS0900 LHS1050
LL0360 LHS0400 / LL0400 LHS0480 / LL0480 LHS0550 / LL0550 LL0650 LL0750 LL0900 LL1050
A 49 54 61 69 81 92 107 122
B 40 45 51 60 70 80 95 110
C 20 20 27 30 32 37 45 50
D 36 40 48 55 65 75 90 105
E 29 31.5 35.5 39 46 52 59.5 67
F 20 22.5 25.5 30 35 40 47.5 55
G 23.5 26 30 33.5 39.5 45 52.5 60
H 16 18 22 24 30 32 37 45
J 31.4 34 40 47 55 63 75 88
K 4.5 5.5 5.5 6.8 6.8 9 11 14
O-ring 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7
Mass kg 0.2 0.2 0.3 0.4 0.5 0.8 1.2 1.7
Notes : 1. MaterialS45C
2. Mounting bolts are not provided. Prepare mounting bolts according to the mounting height using the C dimensions as a reference.
3. If thickness other than C is required, perform additional machining on surface L. Please refer to the drawing.
1217
Manifold Block Manifold Block
Applicable Model/Application Examples Model No. Indication/External Dimensions
High-Power
Manifold Block for LM/LJ/LT/LG B C0.1 Series
4-J
6.3S
Hy Pneumatic Series
D +0.3
Valve / Coupler
0
Size Design No.
Hx
(Refer to (Revision Number) Hydraulic Unit
A
following table)
C0.6 C0.6 Manual Operation
L
E
Accessories
Cautions / Others
O-ring
(Included)
M P Surface
Screw Locator
(mm)
VXF
Model No. LZ0300-MS LZ0360-MS LZ0400-MS LZ0480-MS LZ0550-MS LZ0650-MS LZ0750-MS LZ0900-MS LZ1050-MS
Manual Expansion
Corresponding Item LT0301 / LG0301 LT036 / LG036 LT040 / LG040 LT048 / LG048 LT055 / LG055 LT065 / LG065 LT075 / LG075 LG090 LG105
Locating Pin
Model Number LM0300 / LJ0302 LM0360 / LJ0362 LM0400 / LJ0402 LM0480 / LJ0482 LM0550 / LJ0552 LM0650 / LJ0652 LM0750 / LJ0752 LJ0902 LJ1052
VX
A 48 51.5 56.5 62 70 82 93 107 122
B 34 40 45 51 60 70 80 95 110
Manifold Block
C 18 20 20 27 30 32 37 45 50 WHZ - MD
D 30 36 40 48 55 65 75 90 105 L Z Y - MD
E 28.5 31.5 34 36.5 40 47 53 59.5 67 L Z - MS
F 19.5 20 22.5 25.5 30 35 40 47.5 55 L Z - MP
Hx 30 31.4 34 40 47 55 63 75 88 T MZ- 1 MB
Hy 23 31.4 34 40 47 55 63 75 88 T MZ- 2 MB
J 4.5 4.5 5.5 5.5 6.8 6.8 9 11 14 DZ- M
L 20.5 23.5 26 30 33.5 39.5 45 52.5 60
Manifold Block /
M 3 5 5 0 0 0 0 0 0 Nut
O-ring 1BP5 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7 1BP7 DZ- R
Mass kg 0.1 0.2 0.2 0.3 0.4 0.5 0.8 1.2 1.7 DZ- C
LZ- SQ
W NZ- SQ
Model No. Indication
J
Pressure Switch
LZ 0 48 0 - M P
D +0.3
Ky
JBA
Size Design No.
B
JG A /JG B
Yy Ny Manifold
P Surface 2-O-ring
(Included) JX
(mm)
Model No. LZ0260-MP LZ0300-MP LZ0360-MP LZ0400-MP LZ0480-MP LZ0550-MP LZ0650-MP LZ0750-MP LZ0900-MP Coupler Switch
Corresponding Item LC0262 LC0302 LC0362 LC0402 LC0482 LC0552 LC0652 LC0752 LC0902 PS
Model Number TC0402 TC0482 TC0552 TC0652 TC0752
A 18 18 20 20 27 30 32 37 45 G-Thread Fitting
B 43 48 51.5 56.5 62 70 82 93 107
C 29 34 40 45 51 60 70 80 95
D 26 30 36 40 48 55 65 75 90
H 26.5 28.5 31.5 34 36.5 40 47 53 59.5
J 16.5 19.5 20 22.5 25.5 30 35 40 47.5
Kx 25 30 31.4 34 40 47 55 63 75
Ky 21 23 31.4 34 40 47 55 63 75
Nx 18.5 20.5 23.5 26 30 33.5 39.5 45 52.5
Ny 3 3 5 5 0 0 0 0 0
R 3.4 4.5 4.5 5.5 5.5 6.8 6.8 9 11
Yx 18.5 20.5 23.5 25 28 31 37 42.5 50
Yy 7 7 8 8 11 13 14 15 15
O-ring 1BP5 1BP5 1BP5 1BP5 1BP5 1BP5 1BP7 1BP7 1BP7
Mass kg 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.8 1.2
Notes : 1. MaterialS45C
2. Mounting bolts are not provided. Prepare mounting bolts according to the mounting height using the A dimensions as a reference.
3. If thickness other than A is required, perform additional machining on surface P. Please refer to the drawing. 1218
Company Profile
Sales Offices
Sales Offices across the World
Japan TEL. +81-78-991-5162 FAX. +81-78-991-8787
KOSMEK LTD. 1-5, 2-chome, Murotani, Nishi-ku, Kobe-city, Hyogo, Japan 651-2241
Overseas Sales
651-2241 215
India TEL.+91-9880561695
KOSMEK LTD. - INDIA F 203, Level-2, First Floor, Prestige Center Point, Cunningham Road, Bangalore -560052 India
Taiwan
(Taiwan Exclusive Distributor)
TEL. +886-2-82261860 FAX. +886-2-82261890
Full Life Trading Co., Ltd. 16F-4, No.2, Jian Ba Rd., Zhonghe District, New Taipei City Taiwan 23511
2 16F- 4
Philippines
(Philippines Exclusive Distributor)
TEL.+63-2-310-7286 FAX. +63-2-310-7286
G.E.T. Inc, Phil. Victoria Wave Special Economic Zone Mt. Apo Building, Brgy. 186, North Caloocan City, Metro Manila, Philippines 1427
Indonesia
(Indonesia Exclusive Distributor)
TEL. +62-21-5818632 FAX. +62-21-5814857
P.T PANDU HYDRO PNEUMATICS Ruko Green Garden Blok Z- No.51 Rt.005 Rw.008 Kedoya Utara-Kebon Jeruk Jakarta Barat 11520 Indonesia
TEL.048-652-8839 FAX.048-652-8828
Tokyo Sales Office
331-0815 481
TEL.0566-74-8778 FAX.0566-74-8808
Nagoya Sales Office
446-0076 2101
TEL.092-433-0424 FAX.092-433-0426
Fukuoka Sales Office
812-0006 18-10-101
Global Network
Overseas Aliates and Sales Oces
Distributors
Europe
Canada
U.S.A.
Asia
Mexico
Brazil
Australia
Korea
Japan
China
Taiwan
India
Thailand Philippines
Malaysia
Singapore
Indonesia
FOR FURTHER INFORMATION ON UNLISTED SPECIFICATIONS AND SIZES, PLEASE CALL US. JQA-QMA10823