Defect : REINFORCEMENT LOOSE BONDING TO CONCRETE

Equipment(s):
Grinder
Hacker
Brush
Bucket
Scope
Trowel
Mechanical mixer

Repair Material(s):
Non-shrink grout
Bonding agent
Fresh Concrete
Epoxy mortar

Repair Procedures:

1. Identify the affected reinforcement.


2. Hack out and remove the concrete until found the solid bonding of reinforcement
position (no movement occur between rebar and concrete). Choose a proper method
and tools to minimize damages to the precast component.
3. Clean up the surface from dust, debris, loose concrete and any foreign material using
air blow or wash with clean water. Remove any ponding water and ensure surface
are dry clean.
4. Apply bonding agent to the repair area.
5. Recast the defective portion with using equivalent concrete grade or patch up using
epoxy, non-shrink grout or other approved equivalent material.
6. Mixing of repair material shall according to manufacturer recommendation.
7. Protect the repair area from any disturbance until it hardened.
8. Perform the final finishing as per requirement.