Test Report No.

: 10700275H
Page : 1 of 36
Issued Date : March 1, 2016

VCCI Test Report


Test Report No. : 10700275H
Applicant : Radware Ltd.
Type of Equipment : HTQe (Alteon)
Model No. : ODS-HTQe
Test Regulation : VCCI Council Rules, Normative Annex 1 Technical
Requirements V-3 / 2015.04 Class A
Test Result : Complied

1. This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
2. The results in this report apply only to the sample tested.
3. This sample tested is in compliance with the limits of the above regulation.
4. The test results in this test report are traceable to the national or international regulation.
5. The opinions and the interpretations to the result of the description in this report are outside scopes where
UL Japan has been accredited.
6. This test report covers EMC technical requirements. It does not cover administrative issues such as
Manual or non-EMC test related Requirements. (if applicable)

Date of test: February 9 and 11, 2016

Representative test
engineer:
Koji Yamamoto
Engineer
Consumer Technology Division

Approved by:
Tomoyuki Yamashita
Manager
Consumer Technology Division

RTL02610
The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
13-EM-F0429
Test Report No. : 10700275H
Page : 2 of 36
Issued Date : March 1, 2016

REVISION HISTORY
Original Test Report No.: 10700275H

Revision Test report No. Date Page revised Contents


- 10700275H March 1, 2016 - -
(Original)

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 3 of 36
Issued Date : March 1, 2016

Contents Page
SECTION 1: Applicant Information ..................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ........................................................................ 4
SECTION 3: Test specification, procedures & results ......................................................... 5
SECTION 4: Operation of E.U.T during testing .................................................................. 8
SECTION 5: Conducted disturbance at main port ............................................................ 11
SECTION 6: Radiated disturbance ..................................................................................... 13
APPENDIX 1: Test Data ....................................................................................................... 15
Conducted disturbance at mains ports .......................................................................... 15
Radiated disturbance ...................................................................................................... 23
APPENDIX 2: Test instruments ........................................................................................... 27
APPENDIX 3: Photographs of test setup ............................................................................ 29
Conducted disturbance at mains ports .......................................................................... 29
Radiated disturbance ...................................................................................................... 33

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 4 of 36
Issued Date : March 1, 2016

SECTION 1: Applicant Information

Company Name : Radware Ltd.


Address : 22 Raoul Wallenberg ST. Tel Aviv 6971917, Israel
Telephone Number : 972-3-6224340
Facsimile Number : 972-3-648-4132
Contact Person : Alex Kramp

SECTION 2: Equipment under test (E.U.T.)

Type of Equipment : HTQe (Alteon)


Model No. : ODS-HTQe
Serial No. : Refer to Section 4, Clause 4.2
Receipt Date of Sample : January 21, 2016
Country of Mass-production : Taiwan
Condition of EUT : Production model
This sample is equivalent to mass-produced items
Modification of EUT : No Modification by the test lab
Clock Frequency : 100 MHz, 156.25 MHz

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 5 of 36
Issued Date : March 1, 2016

SECTION 3: Test specification, procedures & results

3.1 Test specification

VCCI Council Rules, Normative Annex 1 Technical Requirements V-3 / 2015.04

3.2 Procedures and results

Test Item Limit Worst Margin Result


<AC port>
[QP]
13.8 dB, 0.20465 MHz, N
[AV]
Technical Requirements
7.2 dB, 0.20465 MHz, N
Conducted Disturbance at main ports Clause 4.1 Complied
<DC port>
Class A
[QP]
26.4 dB, 14.21401 MHz, N
[AV]
20.6 dB, 0.18609 MHz, N
<AC power source>
[QP]
35.9 dB, 13.41400 MHz, Line
[AV]
Technical Requirements
Conducted Disturbance at 23.8 dB, 1.47402 MHz, Line
Clause 4.2 Complied
telecommunication ports <DC power source >
Class A
[QP]
37.0 dB, 1.47370 MHz, Line
[AV]
23.8 dB, 1.47370 MHz, Line
Technical Requirements
4.9 dB
Radiated Disturbance Clause 4.3 Complied
67.947 MHz, Vertical, QP
Class A
UL Japans EMI Work Procedure 13-EM-W0420

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 6 of 36
Issued Date : March 1, 2016

3.3 Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

Conducted emission
Frequency range using AMN(LISN)
(+dB)
0.009 0.15MHz 3.5 dB
0.15 30MHz 2.9 dB

Conducted emission
Frequency range using ANN(ISN)
(+dB)
0.15 30MHz 2.9 dB

Radiated emission (Below 1GHz)


Polarity (3 m*)(+dB) (10 m*)(+dB)
30 300 MHz 300 1000MHz 30 300 MHz 300 1000MHz
Horizontal 4.8 dB 5.2 dB 4.8 dB 5.0 dB
Vertical 4.5 dB 5.9 dB 4.8 dB 5.1 dB

Radiated emission
(3 m*)(+dB) (1 m*)(+dB) (0.5 m*)(+dB) (10 m*)(+dB)
1 6GHz 6 18GHz 10 26.5 GHz 26.5 40GHz 1 -18 GHz
5.1 dB 5.3 dB 5.1 dB 5.1 dB 5.3 dB
* Measurement distance

Conducted emission test


The data listed in this test report has enough margin, more than the site margin.

Radiated emission test (3 m and 10 m)


The data listed in this report meets the limits unless the uncertainty is taken into consideration.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 7 of 36
Issued Date : March 1, 2016

3.4 Test Location

UL Japan, Inc. Ise EMC Lab. *NVLAP Lab. code: 200572-0


4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124
IC Registration Width x Depth x Size of Other
Number Height (m) reference ground plane (m) / rooms
horizontal conducting plane
No.1 semi-anechoic 2973C-1 19.2 x 11.2 x 7.7 7.0 x 6.0 No.1 Power
chamber source room
No.2 semi-anechoic 2973C-2 7.5 x 5.8 x 5.2 4.0 x 4.0 -
chamber
No.3 semi-anechoic 2973C-3 12.0 x 8.5 x 5.9 6.8 x 5.75 No.3
chamber Preparation
room
No.3 shielded room - 4.0 x 6.0 x 2.7 N/A -
No.4 semi-anechoic 2973C-4 12.0 x 8.5 x 5.9 6.8 x 5.75 No.4
chamber Preparation
room
No.4 shielded room - 4.0 x 6.0 x 2.7 N/A -
No.5 semi-anechoic - 6.0 x 6.0 x 3.9 6.0 x 6.0 -
chamber
No.6 shielded - 4.0 x 4.5 x 2.7 4.0 x 4.5 -
room
No.6 measurement - 4.75 x 5.4 x 3.0 4.75 x 4.15 -
room
No.7 shielded room - 4.7 x 7.5 x 2.7 4.7 x 7.5 -
No.8 measurement - 3.1 x 5.0 x 2.7 N/A -
room
No.9 measurement - 8.8 x 4.6 x 2.8 2.4 x 2.4 -
room
No.11 measurement - 6.2 x 4.7 x 3.0 4.8 x 4.6 -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4
semi-anechoic chambers and No.3 and No.4 shielded rooms.

3.5 Test Data, Test instruments, Test set up

Refer to APPENDIX 1 to 3.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 8 of 36
Issued Date : March 1, 2016

SECTION 4: Operation of E.U.T during testing

4.1. Operating Modes

Operating mode: Communication test mode (AC power supply)


Communication test mode (DC power supply)

4.2. Configuration and peripherals

14
AE
15 20
AC

18 16
GND 17 AC 230V/50Hz
AC 100V/50Hz AC 100V/50Hz AD
or DC 48V or DC 48V 19
Console
B, B C, C
AB
MNG 13, 13
2
MNG
ISN
1 13
A
AA
12
Z
Y
11
X
W
V 10

D E F G H I J K L M N O P Q R S T U

1 2 3 4 5 6 7 8 9

*1) Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.
*2) Emission levels of AC 100V/50Hz and AC 100V/60Hz when power was supplied were confirmed at pre check. The test
was performed with AC 100V/50Hz that was the highest emission level.

* Cabling and setup were taken into consideration and test data was taken under worse case conditions.
*ISN, 13 and 13 cables were used for the Conducted emission test on LAN port only.

Note: [LAN] ISN for measurements at ports intended for connection to category 5e (or better) unscreened balanced pair
cables.
Impedance Stabilization Network used for test is as follows:
[LAN] 10Mbps/100Mbps: ISN07

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 9 of 36
Issued Date : March 1, 2016

Description of EUT and Support Equipment


No. Item Model number Serial number Manufacturer Remarks
A HTQe (Alteon) ODS-HTQe 11501002 Radware Ltd. EUT
B AC Power Supply PSS-2A00V 20141110P602599 alteon EUT
B DC Power Supply DPSS-2400V 20141017P601842
C AC Power Supply PSS-2A00V 20141110P602600 Zippy EUT
C DC Power Supply DPSS-2400V 20141017P601761
D SFP - - - -
E SFP - - - -
F SFP - - - -
G SFP - - - -
H SFP - - - -
I SFP - - - -
J SFP - - - -
K SFP - - - -
L SFP - - - -
M SFP - - - -
N SFP - - - -
O SFP - - - -
P SFP - - - -
Q SFP - - - -
R SFP - - - -
S SFP - - - -
T SFP - - - -
U SFP - - - -
V SFP - - - -
W SFP - - - -
X SFP - - - -
Y SFP - - - -
Z SFP - - - -
AA SFP - - - -
AB USB Memory - - - -
AC Laptop PC FMV-C8230 CP271200-01 FUJITSU -
AD AC Adapter FMV-AC319 CP235922-01 FUJITSU -
AE Mouse M-2Y2UL 0X000841 ELECOM -

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 10 of 36
Issued Date : March 1, 2016

List of Cables used


No. Name Length(m) Shield Remarks

1 Fiber Optical Cable 5.0 - -


2 Fiber Optical Cable 5.0 - -
3 LAN Cable 7.6 Shielded -
4 LAN Cable 7.6 Shielded -
5 LAN Cable 7.6 Shielded -
6 LAN Cable 7.6 Shielded -
7 LAN Cable 7.6 Shielded -
8 LAN Cable 7.6 Shielded -
9 LAN Cable 7.6 Shielded -
10 LAN Cable 7.6 Shielded -
11 LAN Cable 7.6 Shielded -
12 LAN Cable 7.6 Shielded -
13 LAN Cable 7.6 Shielded *1)
13 LAN Cable 3.0 Shielded *2)
13 LAN Cable 3.0 Shielded *2)
14 AC Cable 1.5 Unshielded -
15 AC Cable 1.5 Unshielded -
16 Signal Cable 2.0 Unshielded -
17 GND Cable 1.0 Unshielded -
18 DC Cable 1.8 Unshielded -
0.8 *3)
19 AC Cable 1.9 Unshielded -
20 USB Cable 1.5 Shielded -
*1) Used for other tests except for Conducted emission test on LAN port.
*2) Used for Conducted emission test on LAN port only.
*3) Used for other tests except for Radiated emission test.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 11 of 36
Issued Date : March 1, 2016

SECTION 5: Conducted disturbance at main port


5.1 Operating environment

Test place : See data


Temperature : See data
Humidity : See data

5.2 Test configuration

Main port
EUT was placed on a wooden platform of nominal size, 1.0 m by 1.5 m, raised 0.4 m above the conducting ground plane.
EUT was located 80 cm from LISN/AMN and excess AC cable was bundled in center. They were folded back and forth
forming a bundle 30 cm to 40 cm long and were hanged at a 40 cm height to the ground plane. Each EUT current-carrying
power lead, except the ground (safety) lead, was individually connected through a LISN/AMN to the input power source.
All unused 50 ohm connectors of the LISN/AMN were resistivity terminated in 50 ohm when not connected to the
measuring equipment.
Photographs of the set up are shown in Appendix 3.

(AC Mains)
Vertical reference plane

Mains Measuring
lead receiver
Test table
0.4 m

Horizontal reference plane


To power supply source

5.3 Test conditions

Frequency range : 0.15-30 MHz


EUT position : Table top
EUT operation mode : See Clause 4.1

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 12 of 36
Issued Date : March 1, 2016

5.4 Test procedure

Main port disturbance Voltage had been measured with the EUT in a semi anechoic chamber.
The EUT was connected to an LISN/AMN for AC Mains.
An overview sweep with peak detection has been performed.
The measurements were performed with a quasi-peak detector (QP) and if required, with an CISPR average detector (CAV).
Detector Type : QP / CAV
IF Bandwidth : 9 kHz / 9 kHz

5.5 Test Results

Summary of the test results : Pass

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 13 of 36
Issued Date : March 1, 2016

SECTION 6: Radiated disturbance

6.1 Operating environment

Test place : See data


Temperature : See data
Humidity : See data

6.2 Test configuration

EUT was placed on a urethane platform of nominal size, 1.0 m by 1.5 m, raised 0.8 m above the conducting ground plane. The
rear of EUT and peripherals was aligned and flushed with rear of tabletop. I/O cables that were connected to the peripherals
were bundled in center. They were folded back and forth forming a bundle 30 cm to 40 cm long and were hanged 40 cm
height to the ground plane.
Photographs of the set up are shown in Appendix 3.

(Below 1GHz) (Above 1GHz)

6.3 Test conditions

Frequency range : 30 MHz - 300 MHz (Biconical antenna) / 300 MHz - 1000 MHz (Logperiodic antenna)
1000 MHz - 6000 MHz (Horn antenna)
Test distance : 10 m (30 MHz - 1000 MHz) / 3 m(1000 MHz - 6000 MHz)
EUT position : Table top
EUT operation mode : See Clause 4.1

6.4 Test procedure

< Below 1 GHz >


The Radiated disturbance has been measured on the semi anechoic chamber with a ground plane at a distance of 10 m.
Measurements were performed with a quasi-peak detector.
The measuring antenna height was varied between 1 m to 4 m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field intensity.
The measurements were performed for both vertical and horizontal antenna polarization.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 14 of 36
Issued Date : March 1, 2016

< Above 1 GHz >


The Radiated Electric Field Strength intensity has been measured on the semi anechoic chamber with a ground plane at a
distance of 3.4 m.
Measurements were performed with a Peak detector and an average detector.
EUT was rotated a full revolution in order to obtain the maximum value of the electric field intensity.

The height of the center of the EUT was 0.9 m, which was lower than 1m, so the antenna height was fixed at 1.0 m.

The measurements were performed for both vertical and horizontal antenna polarizations.

Horn antenna(BBHA9120D) Minimum dimension of W (Measurement distance=3.4 m )


VD (EUT system)
Frequency [GHz] 3dB (min) W min [m] VD (EUT) [m] CH [m]
[m]
1 60 3.92
2 42 2.61
3 35 2.14
0.2 0.6 0.8
4 35 2.14
5 37 2.27
6 37 2.27
3 dB: The minimum 3 dB beam width of receive antenna.
W: The dimension of the line tangent to the EUT formed by 3 dB at the measurement distance (3.4 m).
[W = 2 * d * tan(0.5 * 3 dB)]
VD (EUT): Vertical maximum dimension of EUT
VD (EUT system): Vertical maximum dimension of EUT system[m] (contained cable length: 0.3 m)
CH: Center height of EUT system[m] (contained cable length: 0.3 m)
*CH[m] =0.8 [m] (Table height) - 0.3 [m] (consideration of cable length based on CISPR16-2-3) +VD(EUT system)[m]/2

The radiated emission measurements were made with the following detector function.
Frequency Below 1 GHz Above 1 GHz *1)
Instrument used Test Receiver Test Receiver
Detector Type Quasi-peak Peak Average
IF Bandwidth 120 kHz VBW: 1 MHz VBW: 1 MHz

*1) The measurement data was adjusted to a 3.0 m distance using the following Distance Factor.
Distance Factor: 20 x log (3.4 m / 3.0 m) = 1.09 dB

6.5 Test Results

Summary of the test results: Pass

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 15 of 36
Issued Date : March 1, 2016

APPENDIX 1: Test Data

Conducted disturbance at mains ports


(AC Power source: Port1)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : AC 100V / 50Hz
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (AC power supply : Port 1)

LIMIT : VCCI Class A QP


VCCI Class A AV
N :QP :AV
[dBuV] << QP/AV DATA >> L :QP :AV
90

80

70

60

50

40

30

20

10

0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
0.15000 39.7 30.0 13.2 52.9 43.2 79.0 66.0 26.1 22.8 N
0.20250 51.2 45.1 13.3 64.5 58.4 79.0 66.0 14.5 7.6 N
0.55843 38.7 34.9 13.3 52.0 48.2 73.0 60.0 21.0 11.8 N
0.61131 34.2 28.1 13.3 47.5 41.4 73.0 60.0 25.6 18.6 N
0.87827 36.1 31.6 13.4 49.5 45.0 73.0 60.0 23.5 15.0 N
9.96120 32.4 27.8 14.5 46.9 42.3 73.0 60.0 26.1 17.7 N
0.15000 39.7 29.9 13.2 52.9 43.1 79.0 66.0 26.1 22.9 L
0.20290 51.0 45.2 13.3 64.3 58.5 79.0 66.0 14.7 7.5 L
0.55912 38.7 34.8 13.3 52.0 48.1 73.0 60.0 21.0 11.9 L
0.61258 33.3 27.2 13.3 46.6 40.5 73.0 60.0 26.4 19.5 L
0.87867 36.7 31.9 13.4 50.1 45.3 73.0 60.0 22.9 14.7 L
9.82648 32.9 28.6 14.5 47.4 43.1 73.0 60.0 25.6 16.9 L

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 16 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(AC Power source: Port2)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : AC 100V / 50Hz
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (AC power supply : Port 2)


LIMIT : VCCI Class A QP
VCCI Class A AV
N :QP :AV
[dBuV] << QP/AV DATA >> L :QP :AV
90

80

70

60

50

40

30

20

10

0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
0.15000 43.1 33.3 13.2 56.3 46.5 79.0 66.0 22.7 19.5 N
0.20465 51.9 45.5 13.3 65.2 58.8 79.0 66.0 13.8 7.2 N
0.56046 38.7 34.2 13.3 52.0 47.5 73.0 60.0 21.0 12.5 N
0.61710 35.4 29.6 13.3 48.7 42.9 73.0 60.0 24.3 17.1 N
0.88201 33.0 29.6 13.4 46.4 43.0 73.0 60.0 26.7 17.0 N
10.5848 0 38.5 34.3 14.5 53.0 48.8 73.0 60.0 20.0 11.2 N
0.15000 43.0 32.4 13.2 56.2 45.6 79.0 66.0 22.8 20.4 L
0.20405 51.3 45.4 13.3 64.6 58.7 79.0 66.0 14.4 7.3 L
0.54737 38.8 33.3 13.3 52.1 46.6 73.0 60.0 20.9 13.4 L
0.61520 37.2 31.5 13.3 50.5 44.8 73.0 60.0 22.5 15.2 L
0.88361 31.8 28.8 13.4 45.2 42.2 73.0 60.0 27.8 17.8 L
10.5816 0 38.3 32.6 14.5 52.8 47.1 73.0 60.0 20.2 12.9 L

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 17 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(DC Power source: Port1)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : DC -48V
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (DC power supply : Port 1)


LIMIT : VCCI Class A QP
VCCI Class A AV
N :QP :AV
[dBuV] << QP/AV DATA >> L :QP :AV
90

80

70

60

50

40

30

20

10

0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
0.18609 36.7 32.2 13.2 49.9 45.4 79.0 66.0 29.1 20.6 N
0.23429 31.9 26.4 13.3 45.2 39.7 79.0 66.0 33.8 26.3 N
0.62137 24.6 22.6 13.3 37.9 35.9 73.0 60.0 35.1 24.1 N
0.87366 24.7 22.0 13.4 38.1 35.4 73.0 60.0 35.0 24.6 N
2.11433 25.2 22.5 13.6 38.8 36.1 73.0 60.0 34.2 23.9 N
14.0320 0 29.4 16.9 14.8 44.2 31.7 73.0 60.0 28.8 28.3 N
0.18549 33.5 27.2 13.2 46.7 40.4 79.0 66.0 32.3 25.6 L
0.23437 32.5 27.7 13.3 45.8 41.0 79.0 66.0 33.2 25.0 L
0.62497 26.7 22.4 13.3 40.0 35.7 73.0 60.0 33.0 24.3 L
0.86099 26.8 25.6 13.4 40.2 39.0 73.0 60.0 32.8 21.0 L
2.11273 25.3 22.0 13.6 38.9 35.6 73.0 60.0 34.2 24.4 L
14.2069 5 30.1 18.9 14.8 44.9 33.7 73.0 60.0 28.1 26.3 L

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 18 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(DC Power source: Port2)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : DC -48V
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (DC power supply : Port 2)


LIMIT : VCCI Class A QP
VCCI Class A AV
N :QP :AV
[dBuV] << QP/AV DATA >> L :QP :AV
90

80

70

60

50

40

30

20

10

0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
0.19520 34.8 28.5 13.2 48.0 41.7 79.0 66.0 31.0 24.3 N
0.23857 33.3 28.5 13.3 46.6 41.8 79.0 66.0 32.4 24.2 N
0.39080 27.4 18.8 13.3 40.7 32.1 79.0 66.0 38.3 33.9 N
0.72882 27.8 25.6 13.4 41.2 39.0 73.0 60.0 31.8 21.0 N
4.20920 26.0 19.7 13.9 39.9 33.6 73.0 60.0 33.1 26.4 N
14.2140 1 31.8 19.8 14.8 46.6 34.6 73.0 60.0 26.4 25.4 N
0.19404 35.1 28.9 13.2 48.3 42.1 79.0 66.0 30.7 23.9 L
0.24000 33.0 27.9 13.3 46.3 41.2 79.0 66.0 32.7 24.8 L
0.36230 27.7 26.9 13.3 41.0 40.2 79.0 66.0 38.0 25.8 L
0.71807 28.8 25.4 13.4 42.2 38.8 73.0 60.0 30.8 21.2 L
4.30179 29.1 23.5 13.9 43.0 37.4 73.0 60.0 30.0 22.6 L
14.1333 2 31.6 20.0 14.8 46.4 34.8 73.0 60.0 26.6 25.2 L

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 19 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(Telecommunication port MNG1: AC Power source)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.3 Semi Anechoic Chamber
Date : 2016/02/11

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : AC 100V / 50Hz
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Ken Fujita

Mode / Remarks : Communicaion Test mode Port MNG1 AC


LIMIT : VCCI Class A QP telecommunication ports
VCCI Class A AV telecommunication ports

[dBuV] << QP/AV DATA >> Line :QP :AV


120
110
100
90
80
70
60
50
40
30
20
10
0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
0.58512 33.9 32.8 9.9 43.8 42.7 87.0 74.0 43.2 31.3 Line
0.61560 35.1 33.7 9.9 45.0 43.6 87.0 74.0 42.0 30.4 Line
1.16942 30.3 28.1 10.0 40.3 38.1 87.0 74.0 46.7 35.9 Line
1.23092 31.3 30.2 10.0 41.3 40.2 87.0 74.0 45.7 33.8 Line
1.47402 39.7 40.3 9.9 49.6 50.2 87.0 74.0 37.4 23.8 Line
13.6320 0 35.1 27.7 10.7 45.8 38.4 87.0 74.0 41.2 35.6 Line

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 20 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(Telecommunication port MNG2: AC Power source)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.3 Semi Anechoic Chamber
Date : 2016/02/11

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : AC 100V / 50Hz
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Ken Fujita

Mode / Remarks : Communicaion Test mode Port MNG2 AC


LIMIT : VCCI Class A QP telecommunication ports
VCCI Class A AV telecommunication ports

[dBuV] << QP/AV DATA >> Line :QP :AV


120
110
100
90
80
70
60
50
40
30
20
10
0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
1.23172 22.9 22.2 10.0 32.9 32.2 87.0 74.0 54.1 41.8 Line
1.47304 34.1 34.3 9.9 44.0 44.2 87.0 74.0 43.0 29.8 Line
2.69700 36.3 26.8 9.9 46.2 36.7 87.0 74.0 40.8 37.3 Line
2.94700 34.0 30.3 10.0 44.0 40.3 87.0 74.0 43.0 33.7 Line
13.4140 0 40.4 29.6 10.7 51.1 40.3 87.0 74.0 35.9 33.7 Line
14.2080 0 39.7 29.5 10.7 50.4 40.2 87.0 74.0 36.6 33.8 Line

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 21 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(Telecommunication port MNG1: DC Power source)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.3 Semi Anechoic Chamber
Date : 2016/02/11

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : DC 42V
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Ken Fujita

Mode / Remarks : Communicaion Test mode Port MNG1 DC


LIMIT : VCCI Class A QP telecommunication ports
VCCI Class A AV telecommunication ports

[dBuV] << QP/AV DATA >> Line :QP :AV


120
110
100
90
80
70
60
50
40
30
20
10
0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
0.39120 29.1 28.9 9.9 39.0 38.8 89.0 76.0 50.0 37.2 Line
0.58476 35.2 33.2 9.9 45.1 43.1 87.0 74.0 41.9 30.9 Line
0.61560 32.2 29.5 9.9 42.1 39.4 87.0 74.0 44.9 34.6 Line
1.17740 33.0 29.0 10.0 43.0 39.0 87.0 74.0 44.0 35.0 Line
1.47370 40.1 40.3 9.9 50.0 50.2 87.0 74.0 37.0 23.8 Line
13.5788 0 36.4 24.5 10.7 47.1 35.2 87.0 74.0 39.9 38.8 Line

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 22 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(Telecommunication port MNG2: DC Power source)

DATA OF CONDUCTED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.3 Semi Anechoic Chamber
Date : 2016/02/11

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : DC 42V
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Ken Fujita

Mode / Remarks : Communicaion Test mode Port MNG2 DC


LIMIT : VCCI Class A QP telecommunication ports
VCCI Class A AV telecommunication ports

[dBuV] << QP/AV DATA >> Line :QP :AV


120
110
100
90
80
70
60
50
40
30
20
10
0
.15M .2M .3M .5M .7M 1M 2M 3M 5M 7M 10M 20M 30M
Frequency[Hz]

Reading Level Corr. Results Limit Margin


Frequen cy
QP AV Factor QP AV QP AV QP AV Phase Comment
[MHz] [dBuV] [dBuV] [dB] [dBuV] [dBuV] [dBuV] [dBuV] [dB] [dB]
1.23120 24.1 23.5 10.0 34.1 33.5 87.0 74.0 52.9 40.5 Line
1.47352 35.1 35.5 9.9 45.0 45.4 87.0 74.0 42.0 28.6 Line
2.58100 38.9 37.6 9.9 48.8 47.5 87.0 74.0 38.2 26.5 Line
3.04920 39.1 37.4 10.0 49.1 47.4 87.0 74.0 37.9 26.6 Line
3.36200 38.8 36.6 10.0 48.8 46.6 87.0 74.0 38.2 27.4 Line
14.2010 0 37.6 26.1 10.7 48.3 36.8 87.0 74.0 38.7 37.2 Line

CHART : WITH FACTOR, Peak hold data. CALCULATION : RESULT = READING + C.F (LISN + ATTEN + CABLE)
Except for the above table : adequate margin data below the limits.

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 23 of 36
Issued Date : March 1, 2016

Radiated disturbance
(AC Power source: Below 1GHz)

DATA OF RADIATED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : AC 100V / 50Hz
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (AC power supply)


LIMIT : VCCI Class A 10m
Except for the data below : adequate margin data below the limits. Horizontal
Vertical
Horizontal
[dBuV/m] << QP DATA >> Vertical
60

50

40

30

20

10

0
30M 50M 70M 100M 200M 300M 500M 700M 1G
Frequency[Hz]

Antenna Loss&
Frequen cy Reading Level Angle Height Limit Margin
DET Factor Gain Polar. Comment
[MHz] [dBuV] [dB/m] [dB] [dBuV/m ] [Deg] [cm] [dBuV/m ] [dB]
142.734 45.5 QP 14.5 -29.8 30.2 50 100 Vert. 40.0 9.8
149.153 45.6 QP 14.7 -29.7 30.6 278 400 Hori. 40.0 9.4
194.758 44.6 QP 16.4 -29.3 31.7 261 400 Hori. 40.0 8.3
194.815 44.1 QP 16.4 -29.3 31.2 145 100 Vert. 40.0 8.8
221.993 41.8 QP 17.1 -29.0 29.9 256 400 Hori. 40.0 10.1
374.999 46.1 QP 16.9 -27.6 35.4 141 130 Vert. 47.0 11.6
374.995 51.0 QP 16.9 -27.6 40.3 238 267 Hori. 47.0 6.7
431.564 45.8 QP 17.8 -27.0 36.6 0 400 Vert. 47.0 10.4
687.494 43.8 QP 20.3 -25.1 39.0 0 184 Hori. 47.0 8.0
687.502 42.3 QP 20.3 -25.1 37.5 237 100 Vert. 47.0 9.5
812.491 40.8 QP 22.0 -24.3 38.5 74 130 Hori. 47.0 8.5
812.488 38.5 QP 22.0 -24.3 36.2 52 400 Vert. 47.0 10.8

CHART:WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN


CALCULATION : RESULT = READING + ANT FACTOR + LOSS & GAIN(CABLE + ATTEN - GAIN(AMP))

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 24 of 36
Issued Date : March 1, 2016

Radiated disturbance
(AC Power source: Above 1GHz)

DATA OF RADIATED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : AC 100V / 50Hz
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (AC power supply)


LIMIT : VCCI(CISPR Pub.22) Class A 3mPK
VCCI(CISPR Pub.22) Class A 3mAV Horizontal
Vertical
Horizontal
[dBuV/m] << AV/PEAK DATA >> Vertical
110
100

90
80

70

60
50

40

30
20

10

0
1G 2G 3G 5G 6G
Frequency[Hz]

Antenna Loss&
Frequen cy Reading Level Angle Height Limit Margin
DET Factor Gain Polar. Comment
[MHz] [dBuV] [dB/m] [dB] [dBuV/m ] [Deg] [cm] [dBuV/m ] [dB]
1700.00 2 54.3 PK 25.9 -32.8 47.4 304 100 Hori. 76.0 28.6
1700.00 2 50.8 AV 25.9 -32.8 43.9 304 100 Hori. 56.0 12.1
1700.00 6 53.7 PK 25.9 -32.8 46.8 83 100 Vert. 76.0 29.2
1700.00 6 50.0 AV 25.9 -32.8 43.1 83 100 Vert. 56.0 12.9

CHART:WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN


CALCULATION : RESULT = READING + ANT FACTOR + LOSS & GAIN(CABLE - GAIN(AMP)) + D.FACTOR

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 25 of 36
Issued Date : March 1, 2016

Radiated disturbance
(DC Power source: Below 1GHz)

DATA OF RADIATED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : DC -48V
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (DC power supply)


LIMIT : VCCI Class A 10m
Except for the data below : adequate margin data below the limits. Horizontal
Vertical
Horizontal
[dBuV/m] << QP DATA >> Vertical
60

50

40

30

20

10

0
30M 50M 70M 100M 200M 300M 500M 700M 1G
Frequency[Hz]

Antenna Loss&
Frequen cy Reading Level Angle Height Limit Margin
DET Factor Gain Polar. Comment
[MHz] [dBuV] [dB/m] [dB] [dBuV/m ] [Deg] [cm] [dBuV/m ] [dB]
67.947 59.2 QP 6.7 -30.8 35.1 0 220 Vert. 40.0 4.9
120.271 45.0 QP 13.0 -30.1 27.9 285 400 Hori. 40.0 12.1
131.756 45.5 QP 13.8 -29.9 29.4 0 100 Vert. 40.0 10.6
131.739 43.1 QP 13.8 -29.9 27.0 329 348 Hori. 40.0 13.0
147.065 41.5 QP 14.6 -29.7 26.4 0 400 Hori. 40.0 13.6
147.407 44.2 QP 14.6 -29.7 29.1 254 100 Vert. 40.0 10.9
190.827 45.2 QP 16.3 -29.3 32.2 226 100 Vert. 40.0 7.8
374.999 48.8 QP 16.9 -27.6 38.1 238 273 Hori. 47.0 8.9
432.006 50.0 QP 17.8 -27.0 40.8 294 238 Hori. 47.0 6.2
687.496 40.9 QP 20.3 -25.1 36.1 165 100 Vert. 47.0 10.9
812.499 37.3 QP 22.0 -24.3 35.0 209 100 Vert. 47.0 12.0
874.989 39.1 QP 22.1 -24.0 37.2 349 100 Hori. 47.0 9.8

CHART:WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN


CALCULATION : RESULT = READING + ANT FACTOR + LOSS & GAIN(CABLE + ATTEN - GAIN(AMP))

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 26 of 36
Issued Date : March 1, 2016

Radiated disturbance
(DC Power source: Above 1GHz)

DATA OF RADIATED EMISSION TEST


UL Japan, Inc. Ise EMC Lab. No.1 Semi Anechoic Chamber
Date : 2016/02/09

Company : Radware Ltd. Report No. : 10700275H


Kind of EUT : On Demand Switch Power : DC -48V
Model No. : Alteon 8420 Extreme SSL Temp./Humi. : 22deg. C / 37% RH
Serial No. : - Engineer : Koji Yamamoto

Mode / Remarks : Communication test mode (DC power supply)


LIMIT : VCCI(CISPR Pub.22) Class A 3mPK
VCCI(CISPR Pub.22) Class A 3mAV Horizontal
Vertical
Horizontal
[dBuV/m] << AV/PEAK DATA >> Vertical
110
100

90
80

70

60
50

40

30
20

10

0
1G 2G 3G 5G 6G
Frequency[Hz]

Antenna Loss&
Frequen cy Reading Level Angle Height Limit Margin
DET Factor Gain Polar. Comment
[MHz] [dBuV] [dB/m] [dB] [dBuV/m ] [Deg] [cm] [dBuV/m ] [dB]
1700.01 0 54.8 PK 25.9 -32.8 47.9 300 100 Hori. 76.0 28.1
1700.01 0 51.1 AV 25.9 -32.8 44.2 300 100 Hori. 56.0 11.8
1700.00 0 50.3 AV 25.9 -32.8 43.4 90 100 Vert. 56.0 12.6
1700.00 0 54.0 PK 25.9 -32.8 47.1 90 100 Vert. 76.0 28.9

CHART:WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN


CALCULATION : RESULT = READING + ANT FACTOR + LOSS & GAIN(CABLE - GAIN(AMP)) + D.FACTOR

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 27 of 36
Issued Date : March 1, 2016

APPENDIX 2: Test instruments

EMI Test Instruments (1/2)


Control No. Instrument Manufacturer Model No Serial No Test Item Calibration Date *
Interval(month)
MLS-25 LISN(AMN) Schwarzbeck NSLK8127 8127-731 CE(EUT) 2015/07/17 * 12
MLS-26 LISN(AMN) Schwarzbeck NSLK8127 8127-732 CE(AE) 2015/07/17 * 12
MLS-10 LISN Kyoritsu KNW-407 8-1851-1 CE(AE) 2015/12/09 * 12
MTA-30 Terminator TME CT-01 - CE 2016/01/15 * 12
MTA-51 Terminator TME CT-01BP - CE 2015/12/01 * 12
MCC-03 Coaxial Cable Fujikura/Suhner/TSJ 5D-2W(20m)/ -/01068 CE 2015/09/29 * 12
3D-2W(7.5m)/
(Switcher)
RG400u(1.5m)/
RFM-E421(Switcher)
MAT-64 Attenuator(13dB) JFW Industries, Inc. 50FP-013H2 N - CE 2016/01/14 * 12
ISN-07 Impedance Stabilization TESEQ ISN ST08 39818 CE 2015/03/13 * 12
Network
MAEC-03 Semi Anechoic TDK Semi Anechoic DA-10005 CE 2015/10/01 * 12
Chamber(NSA) Chamber 3m
MOS-13 Thermo-Hygrometer Custom CTH-180 1301 CE 2016/01/21 * 12
MJM-16 Measure KOMELON KMC-36 - CE -
MSA-03 Spectrum Analyzer Agilent E4448A MY44020357 CE 2015/05/18 * 12
MTR-08 Test Receiver Rohde & Schwarz ESCI 100767 CE 2015/09/02 * 12
MLS-23 LISN(AMN) Schwarzbeck NSLK8127 8127-729 CE(AE) 2015/07/10 * 12
MLS-24 LISN(AMN) Schwarzbeck NSLK8127 8127-730 CE(AE) 2015/07/10 * 12
MTA-31 Terminator TME CT-01 - CE 2016/01/12 * 12
MCC-112 Coaxial cable Fujikura/Suhner/TSJ 5D-2W(10m)/ -/00640 CE 2015/07/02 * 12
SFM141(3m)/
sucoform141-PE(1m)/
421-010(1.5m)/
RFM-E321(Switcher)
MTA-28 Terminator TME CT-01 - CE 2015/11/12 * 12
MMM-08 DIGITAL HiTESTER Hioki 3805 051201197 CE 2016/01/13 * 12
MLS-13 LISN Kyoritsu KNW-407 8-1851-4 CE 2015/12/09 * 12
MTA-53 Terminator TME CT-01BP - CE 2015/12/01 * 12

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 28 of 36
Issued Date : March 1, 2016

EMI Test Instruments (2/2)


Control No. Instrument Manufacturer Model No Serial No Test Item Calibration Date *
Interval(month)
MAEC-01 Semi Anechoic TDK Semi Anechoic DA-06881 RE/CE 2015/09/19 * 12
Chamber(NSA) Chamber 10m
MOS-27 Thermo-Hygrometer CUSTOM CTH-201 A08Q26 RE/CE 2016/01/21 * 12
MJM-25 Measure KOMELON KMC-36 - RE/CE -
COTS-MEMI EMI measurement TSJ TEPTO-DV - RE/CE -
program
MTR-09 EMI Test Receiver Rohde & Schwarz ESU26 100412 RE/CE 2015/06/08 * 12
KBA-05 Biconical Antenna Schwarzbeck BBA9106 2513 RE 2015/11/02 * 12
KLA-04 Logperiodic Antenna Schwarzbeck USLP9143 361 RE 2015/11/03 * 12
MAT-08 Attenuator(6dB) Weinschel Corp 2 BK7971 RE 2015/11/10 * 12
MCC-02 Coaxial Cable Suhner/storm/Agilent - - RE 2015/09/29 * 12
/TSJ
MPA-19 Pre Amplifier MITEQ MLA-10K01-B01-35 1237616 RE 2015/02/03 * 12
MMM-03 Digital Tester Fluke FLUKE 26-3 78030621 RE/CE 2015/08/19 * 12
MAEC-02 Semi Anechoic TDK Semi Anechoic DA-06902 RE 2015/07/01 * 12
Chamber(NSA) Chamber 3m
MOS-22 Thermo-Hygrometer Custom CTH-201 0003 RE 2016/01/21 * 12
MJM-14 Measure KOMELON KMC-36 - RE -
MHA-05 Horn Antenna 1-18GHz Schwarzbeck BBHA9120D 253 RE 2015/05/18 * 12
MCC-165 Microwave Cable Junkosha MWX221 1203S213(1m) / RE 2015/11/10 * 12
1311S166(5m)
MPA-01 Pre Amplifier Agilent 8449B 3008A01671 RE 2015/02/04 * 12

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or international
standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of an
unbroken chains of calibrations.

Test Item:
CE: Conducted disturbance at mains ports / at telecommunication ports
RE: Radiated disturbance

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 29 of 36
Issued Date : March 1, 2016

APPENDIX 3: Photographs of test setup

Conducted disturbance at mains ports


(AC Power source)

Photo 1

Photo 2

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 30 of 36
Issued Date : March 1, 2016

Conducted disturbance at mains ports


(DC Power source)

Photo 1

Photo 2

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 31 of 36
Issued Date : March 1, 2016

Conducted disturbance at telecommunication ports


(AC Power source)

Photo 1

Photo 2

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 32 of 36
Issued Date : March 1, 2016

Conducted disturbance at telecommunication ports


(DC Power source)

Photo 1

Photo 2

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 33 of 36
Issued Date : March 1, 2016

Radiated disturbance
(AC Power source: Below 1GHz)

Photo 1

Photo 2

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 34 of 36
Issued Date : March 1, 2016

Radiated disturbance
(AC Power source: Above 1GHz)

Photo 1

Photo 2

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 35 of 36
Issued Date : March 1, 2016

Radiated disturbance
(DC Power source: Below 1GHz)

Photo 1

Photo 2

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken, 516-0021 JAPAN
Tel: +81-596-24-8999
Fax: +81-596-24-8124
Test Report No. : 10700275H
Page : 36 of 36
Issued Date : March 1, 2016

Radiated disturbance
(DC Power source: Above 1GHz)

Photo 1

Photo 2

End of Report