Sei sulla pagina 1di 20

PRODUCT RELEASE NOTES

Harmony First Mile 200 R2.5.1

Issue: 1.0

Harmony First Mile 200 Release Notes


For
Software Version R2.5.1

Last revised Mar. 31, 2014


Status: Issued

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
HISTORY

Status Date Reason


Initial release for Harmony First Mile 200 R2.5.1 software.
Harmony First Mile 200 R2.5.1 is a pure rebranding release. Before this release,
1.0 Mar. 31st, 2014 the product name is FlexiPacket FirstMile 200, which is with NSN (Nokia
Siemens Networks) logo. From this release, the product name is Harmony First
Mile 200 with DWI (DragonWave Inc.) logo.

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0

Release Date Mar. 31st, 2014

Released System Omni File Harmony First Mile 200:


SW bundle
File Names Current Release: R2.5.1
Current Build Version 2.5.1.2
Release Date: 31st Mar. 2014
WebLCT: 2.5.1.2
Previous Build Version: 2.5.4

Applicable Products Harmony IDU


System FM200 R2.5 supports the following ODU configuration:
Installation 1+0
Types 1+1 hot standby/space diversity
1+1 frequency diversity
2+0 frequency diversity
2+0 XPIC
2+2

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
System Type
Compatibility and FPR 1.3 FPR FPR 1.4 FPMR 2.1 FPMR 2.4 FPMR 2.5 FPMR 2.7
Interoperability 1.3EP1
FM200 R1.0EP1 - - -
FM200 R2.0 -
FM200 R2.0_1.0.0
FM200 R2.0_2.0.0
FM200 R2.5.1

FM200 R2.5.1 is managed from Netviewer 10.8.

Notes:
means the interoperability can be guaranteed.
- means the interoperability should be OK but without guarantee.
means the interoperability does work.

Major Features of Harmony First Mile 200:


General Features
Extended indoor temperature range (-5 to +55C)
Extended temperature range (-40 to +55C) in FOC with pre-heater
Low power consumption
On field MTBF > 100 years
Installation in FlexiOutdoor Case (FOC)
19-inch and 23-inch ETSI rack mounting
-48V DC inputs

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
Interfaces on The Base System
4x 10/100/1000Base-T, supporting Synchronous Ethernet, and two of them support P+E
2 x SFP interfaces, can be configured either as GE ports
8 x E1/ T1 CESoPSN and SAToP
1 x local management port (out-of-band or OOB), 1 x DCN port
Dry contact port with 2 inputs and 5 outputs
Interface for memory key
Ethernet Services
E-Line Service
E-LAN Service
Basic traffic classification rules: port, tagged/untagged, customer VLAN ID, customer 802.1p bits, and customer
DSCP bits
Advanced traffic classification rules: source/destination MAC address, EtherType, Inner VLAN ID, Inner 802.1p
bits, Source/Destination IP address, IP protocol, Source/Destination TCP/UDP port, etc.
VLAN Tag manipulation supports Translation and Transparent mode
Jumbo frame (up to 9600-byte MTU)
Automatic and configurable MAC address aging time
Support for static MAC addresses (not subject to MAC address aging)
MAC address flushing per VLAN
Per-service SLA

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
Tagged mapping rule
Hitless adding/removing port on E-LAN service
Hitless adding/removing a mapping rule to an UNI port
UNI port shutdown on remote UNI failure
Bridging Modes
802.1Q
802.1ad
Ethernet QoS
Traffic policing supporting CIR and PIR bandwidth profile
8 priority queues per port
Queue Scheduling: SP, SP+WRR, SP+WDRR
Support for Multi-QoS (i.e., multiple priorities per service)
Traffic Shaping per port and per queue
Congestion management with sRED
Rate limit on broadcast/multicast/unknown traffic per port for E-LAN service
Configurable shaping burst size
Configurable buffer allocation
Ethernet OAM
End-to-end performance monitoring according to Y.1731
End-to-end fault management according to 802.1ag

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
End-to-end performance of services per port:
RMON/RMON2
Service (E-Line/E-LAN) Statistics
16 * 15 minutes and 4 * 24 hours period statistics
UNI port shutdown on service failure
Protection
1+1 ODU hot-standby on one IDU
xSTP for E-LAN service
Link OAM for xSTP
802.1ad LAG support on UNI ports
CES Linear Protection
TDM Circuit Emulation Service (CES)
E1/T1 CESoPSN
SAToP for E1
Clock Synchronization
Differential Clock Recovery
Synchronous Ethernet, supporting SSM
Any E1/T1 interface as line and external clock source
Management and Security
SNMPv3 with encryption, SSH, SFTP

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
DCN Configuration Auto Recovery
ANSI Support
ANSI support (regulatory, T1)
Licenses and License Management
The following functions require software license.
From Basic to 6 Interfaces + Hot Stand By
MSTP/RSTP
Ethernet OAM
Security
CES Linear Protection
G.8031 linear Protection
G.8032 ring Protection
License Management is via CLicS. See section License Management.

Supported HW
T555FME0.20 Harmony First Mile 200
T555IFMMK.21 Harmony First Mile ETSI/21" mounting kit
T555IFMMK.19 Harmony First Mile 19" mounting kit
T555IFMAF.00 Harmony First Mile Alarm Cable for FOC
T555IFMAK.00 Harmony First Mile Alarm Connector kit
T555ACR2.00 Harmony First Mile Alarm Cable reel 200m

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
Applicable User Manual R2.5.1
Harmony First Mile 200 Rel.2.5.1, Documentation Guide
Identification number: PM-000015-01-EN

Harmony First Mile 200 Rel.2.5.1, IDU Product Description


Identification number: PM-000016-01-EN

Harmony First Mile 200 Rel.2.5.1, IDU Accessories Product Description


Identification number: PM-000017-01-EN

Harmony First Mile 200 Rel.2.5.1, IDU HW Install


Identification number: PM-000018-01-EN

Harmony First Mile 200 Rel.2.5.1, Operate & Maintain


Identification number: PM-000020-01-EN

Harmony First Mile 200 Rel.2.5.1, Troubleshoot


Identification number: PM-000021-01-EN

Harmony First Mile 200 Rel.2.5.1, IDU and Accessories Order Codes Reference
Identification number: PM-000019-01-EN

Harmony First Mile 200 Rel.2.5.1, Environmental Product Declaration


Identification number: EPD-000016-01-EN

Known fatal bugs R2.5.1


None

Operation Considerations
and Hints 1.1. Operating the System
It is strongly recommended not to frequently plug and unplug the memory key with short
interval. This interval must be at least 1 minute.
Whenever the system is booting up, it takes some time to read the memory key. Please make

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
sure that the current active software image is up and running for at least 6 minutes before
switching to the backup software image.

1.2. License Management


To get the license key for a dedicated feature, follow the following steps:
1. Customer releases the purchase order and provides the product target ID information to
DWI OPS (Operations Dept.).
2. DWI OPS generates the license key according to the purchase order.
3. DWI OPS ships the license key back to the customer.

1.3. OOB Interface


A local terminal can be directly connected to the OOB interface of the IDU with the IP address
192.168.254.100/24.
This IP address is not configurable.

1.4. Public IP Address of DCN Interface


DCN Port System IP address is user-configurable via WebLCT.
Default IP address: 192.168.255.100/24
The management VLAN ID must be set (permitted values 51 ~ 4094) in order to use In-Band
Management. Default management VLAN ID is 127.

1.5. Service VLAN ID Range for E-LAN and E-Line Service


E-LAN Service and E-Line Service need to use value 51~4094 for Service VLAN Tag.
WebLCT can be used to create E-LAN and E-Line service.

1.6. CES over Ethernet Service


CES Service (both CESoP and SAToP) needs to use either an E-LAN or an E-Line service as

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
the underlying transmit vehicle (a.k.a. pseudo-wire or PW). So when setting up a CES service,
either an E-LAN or an E-Line service must be created firstly, and then CES parameters are
added to the E-LAN or E-Line service so that the CES service is established.
WebLCT can be used to create CES service.

1.7. The Number of Service


Total Number of T1/E1 CESoP Services:
Due to TDM port of FM200 is 8, maximum of CES services is suggested to be 8, including
CESoP and CES protection services.
Total Number of Ethernet Services:
128 E-LAN and 256 E-Line services shall be supported. The maximum of total service is 256
in any case.

1.8. CES TDM Mode Switching


Changing TDM Mode between E1/T1/J1 will make system reboot. Note that all the TDM
configurations in the system will be automatically deleted after rebooting if the TDM Mode in
the configuration file is not consistent with that of the system.

1.9. 1+1 Hot-Standby ODU Function


When a LPG is created, a dedicated service will also be created for P-CCM between two
ODUs.
P-CCM can be enabled via the Bridge configuration and Port Configuration.

1.10. Power-Plus-Ethernet (P+E) Deployment

Important Note: The P+E solution is not compatible with Power-over-Ethernet (PoE)
defined by IEEE 802.3af and 802.3at since P+E intends to provide higher power than that
provided by the two standards. Thus, it is harmful to connect FM200 P+E interfaces to
This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
other devices than DWIs Harmony ODUs.
Warning: It is forbidden to connect other P+E ports (for example, the P+E ports of the
external Power Injector) to the P+E ports of FM200 whether or not the P+E function of
FM200 is disabled or enabled.
It is also highly risky to connect SPD (Surge Protection Device) to P+E ports of FM200.
Fm200 and its Power Injector Card have surge protection on P+E ports. External SPD
will not help protecting FM200 but may damage it.

R2.5.1 Bug list


Bug ID Short Description From Release
Known Issues or Limitations in R2.5.1
System
ID_13186 System is suspended after frequently cold reboot. R2.5
In very few cases, system may be suspended during cold reboot
if cold reboot frequently. It can be solved by cold reboot again.
Management and WebLCT
ID_12944 WebLCT display wrong status for connection R2.5
Sometime, WebLCT displays disconnect, but the ping is ok and
the WebLCT also can be operated.
ID_12993 DCN port down in serial port but LED display up R2.5
In very few cases, DCN port cannot ping successfully while the
LED is still up.
Protection

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
ID_13137 In a few cases, G.8032 switching overtime. R2.5
Description: In below cases, switching time of G.8032
is a little longer than 50ms, most likely between 60 to
80ms.
- When trigger 8032 switching by down GE port which
connects with ODU.
- When G.8032 and G.8031 work in same port.
ID_13174 The log for G.8032 status change is not user friendly R2.5
When G.8032 status changes, the log only records
ERPSStateChange which is difficult to understand. It will be
corrected in next release.
ID_13178 G.8032 cannot be enabled in interworking environment R2.5
In very few cases, G.8032 cannot enable in the interworking
environment of FM200 with FPH800. The workaround is
Delete it and rebuild it.
Known Issues or Limitations From Previous Releases
System
FR_0000002942 Old FlexiPacket Radio requires no lower than 42.5VDC power
input to IDU in order to get powered by P+E port of IDU.
Description: When a P+E port of IDU is working under 40.5VDC
input and is connected with the old HW Packet Radio (FPR)
that requires minimum 32VDC power input, the FPR cant be
powered on. This is a normal behavior. If the IDU DC power
input is increased above 42.5VDC, there will be no such
problem.
The new FPR that supports 28VDC can be powered up by
FM200 via P+E port with 40.5VDC input.
Supported maximum P+E cable length is:
For old FPR (32VDC), it can be 65m.
For new FRP (28VDC), it can be 100m.
FR_0000003752 Do NOT power off/on system during its warm restart.

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
Powering off/on the system during its warm restart may cause
the systems flash memory to be defective.
FR_0000003850 Flash memory may become defective in rare cases.
In rare cases (1~2%), powering off the system may cause some
parts of the flash memory defective, but the system will
continue to work.
FR_0000004051 WebLCT May Lose Communication with The System.
When the speed of the Ethernet interface of the PC running
WebLCT is forced (by manual configuration) to 10Mbps, the PC
will not be able to communicate with the system.
Solution: Do not manually configure 10Mbps on the network
interface of the PC.
FR_0000007980 Back-to-back connected IDU can be powered up by port GE3
or GE4 of the other IDU.
When two IDUs are connected together via Ethernet ports, in
case one of the ports between the two IDUs is P+E port and
P+E function is enabled on one IDU, the other IDU can be
powered up unexpectedly by this P+E port.To avoid this issue,
the two IDUs can be connected via non-P+E ports or P+E
function is disabled.
FR_0000009990 SW file is not able to copy directly between Win7 SP1 and
WindowsXP.
Sometimes directly copying SW file between Windows XP and
Win7, the file size may be changed. It will be failed to
download the file with changed size to NE.
Workaround: Compress the SW file by winRAR or winZip
firstly. Copy this compressed file between winXP and win7
wont change the file size.
FR_0000010021 The LAG protection on the SFP port needs ALS enabled and
the switch time is long.

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
When SFP ports configure LAG protection, the ALS must to be
enabled. Otherwise the protection doesnt work. The
protection switch time will be over 500ms, it is because it
takes time that ALS Tx shutdowns switch.

E-LAN Servises
FR_0000005453 Rebooting the system shortly after a service is created may
cause service disabled.
Description: Rebooting the system in less than 10 seconds
after a service is created or service configuration is changed,
the service will become disabled. This is because the system
has not finished saving the configurations when it is reboot.
Suggestion: Do not reboot the system right away after creating
or reconfiguring a service.
FR_0000001582 Actual MAC address aging time exceeds the configured aging
time.
Description: Actual MAC address aging time exceeds the
configured aging time. For example,
When the configured aging time is 300sec, the actual aging
time is 400sec.
When the configured aging time is 1000sec, the actual aging
time is 1600sec.
When the configured aging time is 5000sec, the actual aging
This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
time is 9000sec.
QoS
FR_0000001740 WRR scheduling is not always accurate.
WRR scheduling is not always accurate when frame MTU is
larger than 1000 bytes, in which case, queue 7 and queue8
demonstrate the same weight regardless of the actual weight
configured for them.
FR_0000001741 DRR scheduling is not always accurate.
DRR scheduling is not always accurate same phenomenon as
FR_0000001740.
FR_0000004848 Rate limiting is not accurate
Description: Rate limiting is not accurate when both Whole
Traffic Policer and BC/MC/Unknown Policer are applied at the
same time.

Note: Whole Traffic Policer is an independent traffic policer


that can be applied to a port and limit the rate of all the traffic
on this port. BC/MC/Unknown Policer is the traffic policer that
limits all the Broadcast, Multicast and Known-Address traffic
rate on a port for all the E-LAN services on this port.

Workaround solution: In most cases, Whole Traffic Policer is


not used because each service has its own traffic policer. In
this case, Whole Traffic Policer is disabled and this problem
will not appear.
Protection
FR_0000003311 Temporary loops may exist when system is warm restarting. R2.5
When the system is warm restarting, temporary loops may
exist in the network until xSTP is up and running.

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
FR_0000006640 Ethernet port performance statistics is lost if LAG on this port R2.0
is deleted firstly.
Description: When a LAG is deleted before it is
administratively disabled, the Ethernet ports in this LAG will
not have Ethernet Port performance statistics anymore.
Recreating LAG on these ports does not address the issue.
Solution: Disable the admin status of LAG before deleting it.
OAM
FR_0000007938 Spanning Tree enabling/disabling sometimes causes E-CCM R2.0
loss
Description: E-CCM is the continuity check message between
IDU and ODUs to detect the status of the ODUs working in 1+1
hot-standby mode. E-CCM is generated by the CPU of the
system. As the operation of enabling or disabling xSTP may
make CPU very busy, E-CCM could get lost for a short period of
time, which will force the active and standby ODU to switch
their roles, and switch again when xSTP gets converged.
FR_0000008853 Loss Measurement and Service Statistics cant be enabled at
the same time.
Loss Measurement and Service Statistics cant be enabled at
the same time. Enabling one of them will stop the other
automatically. This is because that they are using the same
counters and enabling one function will clear the counters,
making the counter values inaccurate for the other function.
FR_0000008687 Service PM disable/enable will cause packet dropping.
When service performance measure (PM) is disabled or
enabled, there will be a loss of few packets. This is because
enabling/disabling service PM will cause the switch chip to re-
apply the mapping rules.
CES

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
FR_0000004032 SSRC range doesnt fully comply with standard CESoPSN and
SAToP.
SSRC (Synchronization Source) range does not fully comply
with the standard CESoPSN (RFC5086) and SAToP (RFC4553).
The supported range is 0x00000000~0x7FFFFFFF. Range
0x80000000 ~ 0xFFFFFFFF is not supported.
ID_09681 PW PM can only count 3 loss packets for CESoP service.
When 3 consecutive CES frames get lost, the CES service is
perceived as down, thus PM stops counting and PM counter
is reset.
ID_10227 The failure of CESoP modification may make the CESoP
service broken.
When the CVLAN ID of CESoP is modified to conflict with a
used one, the CESoP service will break and need to be re-
configured.
Clock Synchronization
FR_000006917 SFP port with electrical SFP cannot be used as timing source.
when the SFP port of the system is configured as GE port and
electrical SFP is inserted in this port, it cannot be used as
Synchronous Ethernet clock source.
Management and WebLCT
FR_000003930 Too many MAC addresses will by displayed on WebLCT very
slowly.
When the system learns a large number of MAC addresses, it
may take a few to tens of seconds for WebLCT to display all
the MAC addresses.
FR_0000005994 Menu item Statistics -> SLA does not work if Service
Performance Measurement is not enabled.
In WebLCT, menu item Statistics -> SLA (which shows the
statistics of Green Packets and Total Packets of each service)

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
does not work if Service Performance Measurement (i.e.,
Service PM) is not enabled. To enable service PM, operators
can go to menu item Performance -> Ethernet Service ->
Switch and enable Service PM for the selected services.
FR_000009179 LPG Admin and Operation status disappear after NE is
upgraded from R1.0EP1 to R2.0.
When the LPG is configured in R1.0 EP1 with Admin status
enable and Operation status up, the Admin status and
Operation status disappear after the NE is updated to R2.0.
The traffic is not impacted and the LPG remains unchanged.
The abnormal status can be eliminated after removing and re-
configuring the LPG in R2.0.

This release will be R2.6


superseded by
Upgrade and Downgrade Please refer to PM-000020-01-EN, Harmony FirstMile 200 Rel.2.5.1, Operate & Maintain
Chapter 4.4.5 Upgrade and downgrade the NE.

Backwards Compatibility Release 2.5.1 is backwards compatible with any previous releases.
Major differences in this The product is renamed as Harmony First Mile 200, while the name in previous releases is Flexi
version Packet First Mile 200.

Minor features None


PTS/Bug fixes Bug fixed from R2.5
Bug ID Short Description Original
Release
ID_11703 RMON counter not only count received packets. R2.0 EP2
RMON counters should only count received packets but
currently received and sent packets are both counted.

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.
PRODUCT RELEASE NOTES
Harmony First Mile 200 R2.5.1

Issue: 1.0
ID_12712 CVLAN is not ordered by number but string. R2.0 EP2
In mapping rule part of WebLCT, click "rank by order" of
CVLAN, after that the CVLAN is not ordered by number but by
string.

This document contains confidential information which is proprietary to DragonWave. No part of its contents may be used, copied, disclosed, or conveyed to
any party in any manner whatsoever without prior written permission from DragonWave.
Note that the original signed off document is held in Documentation Control. When printed this document is uncontrolled.
DragonWave Inc.

Potrebbero piacerti anche