The voltage signal must be perfect ... because distortion may occur at the
at the source... end of the line
Schneider Electric 4
I. Introduction
lV.Conclusion
Schneider Electric 5
II. What is a harmonic waveform?
H1 = 50Hz Hn = n x 50Hz
1.5 1.5 1.5
1 1 1
0 0 0
-1 -1 -1
THD (U or I) % = 100 x
Schneider Electric 6
II. Current distortion
100
Single-phase loads
50
Computers
0
Phones H1 H3 H5 H7 H9 H11 H13 H15 H17
Danger
Lighting ...
Schneider Electric 7
II. The effects of harmonics
Voltage distortion:
Excessive temperature rise in motors
Electrical noises
Sensitive electronic equipment malfunction
LV
Main LV
Switchboard (MLVS) Increased RMS current
Secondary
switchboard
Non-linear current
circulating in the cables
feeder S1 feeder S2 feeder S3
Final distribution
enclosure
Increased THDU
M M M
Schneider Electric 9
II. The effects of harmonics
S= P2 + Q2
ST (VA)
Schneider Electric 10
II. The effects of harmonics
0 Phase 2
0 90 180 270 360 450
Phase 3
-6
Schneider Electric 11
II. Harmonics mitigation solutions
Electromechanical solutions
Active filters
Normal or replacement
sources
1
h3 h9 h5 h7
D D D Y L F
Over-sizing of sources,
cables, etc. yn y y
d y 5 6
1 - The harmonics are not 3 4
eliminated. Tuned
p1 = p2 p1 = p2 Anti-harm.
- Very costly filters
2 reactors
&
Transformers with series filters
different couplings
3 and 4 attenuate h5 and 5 Attenuates harmonics
2 Limits h3 and multiples. h7 (6-pulse bridge) at the tuning frequency.
6 Decreases THD(i).
Schneider Electric 12
II. Passive filter: architecture & design
Ph
No capacitors
Lo No power electronics
Schneider Electric 13
II. Cleanwave: solution for neutral currents
At A Glance:
Zero sequence harmonic filter
Reduces neutral currents in input
commercial & industrial buildings
Balancing of 3-phase currents output
12-280 kVA (expandable)
3-phase low voltage applications
Customer benefits
Simple and highly reliable design
Reduction of neutral currents by 10:1
Compliance with harmonic standards
Capacity upgrade by parallel
connection
Operational savings
Easy integration into power
distribution cabinets (Chassis Format)
Schneider Electric
Easy sizing and installer friendly 14
II. Sizing cleanwave
Schneider Electric 15
II. Unbalanced load tests
I1: 150A I1: 126A I1: 112A I1: 126A I1: 107A I1: 154A
I2: 149A I2: 126A I2: 122A I2: 126A I2: 46A I2: 0A
I3: 151A I3: 127A I3: 65A I3: 0A I3: 46A I3: 0A
In: 21A In: 242A In: 25A In: 201A In: 25A In: 150A
In in In in
In in
I1 out I1 out
I1 out
In out In out
In out
Schneider Electric 16
II. Active harmonic conditioner: architecture &
design
I source I load
Power Non-linear
source load
I conditioner
Active
harmonic
conditioner
2 2 2
1,5 1,5 1,5
1 1 1
=
0,5
+
0,5 0,5
0 0 0
-0,5 -0,5 -0,5
-1 -1 -1
-1,5 -1,5
-2 -2 -2
4 3
Active
The conditioner 1
harmonics are supplies the 2
eliminated Equipment is the
required CTs analyze the
upstream and source of
harmonics to harmonics harmonics
apparent the load required by the
power is load
reduced
Schneider Electric 18
II. Sinewave standard solution: 20-480A of
harmonic compensation
Schneider Electric 19
II. Sinewave features
Input
Voltage : 400 V , - 20% , + 15%
Phases : 3-phase with or without neutral. Compatible
Operation with single phase and unbalanced load
Frequency : 50 Hz or 60 Hz, +/- 8% auto-sensing
Compensation characteristics
Harmonics covered : H 2 to H 25
Type of compensation : Harmonics - cos phi - mixed (Hn + cos)
Compensation mode : Overall or selective (specific harmonics)
Attenuation ratio : >10 at full load ( THDI)
Cos phi correction : Up to 1
THDU reduction : According to the installation parameters, THDU
reduction will be determinated by the SITE AUDIT
Response time : < 40 ms in overall current compensation mode
Overload : Automatic current limitation
Schneider Electric 20
II. Example: Variable Speed Drive load
2
2
1,5
1,5
1
1
0.5
0.5
0 0
-0.5 -0.5
-1 -1
-1,5 -1,5
-2 -2
Schneider Electric 21
II. Example: Variable Speed Drive load
120 120
100 100
80 80
60 60
40 40
20 20
0 0
H1
H3
H5
H7
H9
H11
H13
H15
H17
H19
H21
H1
H3
H5
H7
H9
H11
H13
H15
H17
H19
H21
Harmonic current without SineWave Harmonic current with SineWave
Schneider Electric 22
II. Accusine solution
Schneider Electric 23
II. Accusine features
Input
Voltage : 208-480V, - 10% , + 10%; auto sensing
Phases : 3-phase, 3-wire with or without neutral.
Compatible Operation with single phase
and unbalanced load
Frequency : 50 Hz or 60 Hz, +/- 5% auto-sensing
Compensation characteristics
Harmonics covered : H 2 to H 50 (no filtering on neutral conductor)
Type of compensation : Harmonics - cos phi - mixed (Hn +
cos)
Compensation mode : overall
Attenuation ratio : 10:1 overall
Cos phi correction : Up to unity; can also inject lagging
VARS
THDU reduction : Guaranteed compliance with
IEEE519; UK G5/4 or
IEC 61000-2-3
Response time : < 10 ms
Schneider Electric Overload : Automatic current limitation 24
II. Customer benefits / active power solutions
Schneider Electric 26
III. Accusine application case study
Schneider Electric 27
III. Accusine application case study
95.2%
Schneider Electric 28
I. Introduction
lV.Conclusion
Schneider Electric 29
lV. Conclusion
Even more so for Oil & Gas processes where the availability and quality
of Power is quite critical,
Schneider Electric 30
The 3 main messages
Investing in power quality will improve both your operations and profits