- strength class;
- exposure classes;
- chloride content class;
- classes or target values specified for the property of self-compaction;
- limiting values of concrete composition, if specified;
- maximum nominal upper aggregate size;
- any other specified property.
NOTE: In the case of ready-mixed concrete, conformity is undertaken to verify that the claims made on
the delivery ticket are valid.
In the case of precast and site made concrete where the user and producer are the same party, testing
and verification is undertaken as part of the production control at the same rate of testing and using the
same criteria as for conformity. In this case, failure to satisfy the criteria does not lead to a declaration of
non-conformity but to an internal investigation to assess whether this indicates a non-conformity with the
requirements of the hardened concrete.
The rate of testing the slump-flow shall be that given in EN 206-1 for consistence or, in the case of precast
products, EN 13369 and/or other relevant product standards. The T500 value, V-funnel time, L-box testing
and sieve segregation resistance testing shall only be undertaken if specified.
Conformity to the properties of SCC is confirmed if the specified criteria satisfy the limits given in Table
A.6.
For the other properties and requirements specified, the rate of testing and conformity criteria given in EN
206-1 apply or, in the case of precast products, the relevant product standards and/or EN 13369.
SCC 028 46