Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
UDC 624.21.01:624.012.45
BS 5400-7:1978
Cooperating organizations
The Steel and Concrete Standards Committee, under whose direction this
British Standard was prepared, consists of representatives from the following
Government departments and scientific, technical and professional
organizations:
Contents
NOTE The numbering of the clauses and subclauses in this Part is similar to that in Part 8 for ease
of cross-reference.
Page
Cooperating organizations Inside front cover
Foreword iv
1 Scope 1
2 References 1
3 Concrete 1
3.1 Classification of concrete mixes 1
3.1.1 General 1
3.1.2 Ordinary structural concrete 1
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
BSI 12-1998 i
BS 5400-7:1978
Page
3.9.5 Water/cement ratio 7
3.9.6 Air content to fresh concrete 7
3.9.7 Additional tests on concrete for special purposes 7
3.10 Surface finishes of concrete 7
3.10.1 Trial panels 7
3.10.2 Control of colour 7
3.10.3 Release agents 7
3.10.4 Surface finishes for concrete 7
3.10.5 Protection 8
3.11 Construction with concrete 8
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
ii BSI 12-1998
BS 5400-7:1978
Page
5.1.2 Cold worked high tensile alloy bar 13
5.1.3 Stress-relieved seven-wire strand 13
5.1.4 Nineteen-wire strand 13
5.1.5 Testing 13
5.2 Handling and storage 13
5.3 Surface condition 13
5.4 Straightness 13
5.4.1 Wire 13
5.4.2 Strand 13
5.4.3 Bars 13
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
5.5 Cutting 13
5.6 Positioning of tendons, sheaths and duct formers 14
5.7 Tensioning the tendons 14
5.7.1 General 14
5.7.2 Tensioning apparatus 14
5.7.3 Pretensioning 14
5.7.4 Post-tensioning 14
5.8 Protection and bond of prestressing tendons 15
Table 1 Grades of concrete 2
Table 2 Prescribed mixes for general use 4
Table 3 Rates of sampling testing 6
Table 4 Normal curing periods 10
Standards publications referred to Inside back cover
Foreword
Summary of pages
This document comprises a front cover, an inside front cover, pages i to iv,
pages 1 to 16, an inside back cover and a back cover.
This standard has been updated (see copyright date) and may have had
amendments incorporated. This will be indicated in the amendment table on
the inside front cover.
1)
In course of preparation
iv BSI 12-1998
BS 5400-7:1978
BSI 12-1998 1
BS 5400-7:1978
2 BSI 12-1998
BS 5400-7:1978
3.6 Requirements for designed mixes Any change in the source of material or in mix
3.6.1 Target mean strength. The target mean proportions (except changes in cement content of not
strength specimen shall exceed the specified more than 20 kg/m3) shall be subject to the
characteristic strength by at least the current engineers prior
margin. The current margin for a concrete mix 3.6.3 Trial mixes. The contractor shall give notice
shall be determined by the contractor and shall be to enable the engineer to be present at the making
taken as the lesser of of trial mixes and preliminary testing of the cubes.
a) 1.64 times the standard deviation of cube tests The contractor shall prepare trial mixes, using
on at least 100 separate batches of concrete of samples of approved material typical of those he
nominally similar proportion of similar materials proposes to use in the works, for all grades to the
and produced over a period not exceeding 12 engineers satisfaction prior to commencement of
months by the same plant under similar concreting.
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
supervision, but not less than 2.5 N/mm2 for The contractor shall determine the workability of
concrete of grade 15 or 3.75 N/mm2 for concrete of the trial mixes.
grade 20 or above; Sampling and testing procedures shall be in
b) 1.64 times the standard deviation of cube tests accordance with BS 1881.
on at least 40 separate batches of concrete of The concreting plant and means of transport
nominally similar proportions of similar employed to make the trial mixes and to transport
materials and produced over a period exceeding 5 them representative distances shall be similar to
days but not exceeding 6 months by the same the corresponding plant and transport to be used in
plant under similar supervision, but not less the works. A clean dry mixer shall be used and the
than 5 N/mm2 for concrete of grade 15 first batches discarded. Test cubes shall be taken
or 7.5 N/mm2 for concrete of grade 20 or above. from trial mixes as follows. For each mix a set of six
Where there are insufficient data to satisfy a) or b) cubes shall be made from each of three consecutive
above, the margin for the initial mix design shall be batches. Three from each set of six shall be tested at
taken as 10 N/mm2 for concrete of grade 15 an age of 28 days and three at an earlier age
or 15.0 N/mm2 for concrete of grade 20 or above. approved by the engineer. The cubes shall be made,
This margin shall be used as the current margin cured, stored, transported and tested in
only until sufficient data are available to satisfy a) compression in accordance with the specification.
or b) above. However, subject to the engineers The tests shall be carried out in a laboratory
approval, when the specified characteristic strength approved by the engineer.
approaches the maximum possible strength of The average strength of the nine cubes tested at 28
concrete made with a particular aggregate, a days shall exceed the specified characteristic
smaller margin not less than 5 N/mm2 for concrete strength by the current margin minus 3.5 N/mm2.
of grade 15 or 7.5 N/mm2 for concrete of grade 20 or
above may be used for the initial mix design. 3.6.4 Additional trial mixes. During production
the contractor shall carry out trial mixes and tests,
3.6.2 Suitability of proposed mix proportions. if required by the engineer, before substantial
The contractor shall submit for the engineers changes are made in the materials or in the
approval, prior to the supply of any designed mix, proportions of the materials to be used, except when
the following information: adjustments to the mix proportions are carried out
a) the nature and source of each material; in accordance with 3.8.5.1.
b) either; 3.7 Requirements for prescribed mixes
1) appropriate existing data as evidence of 3.7.1 Prescribed mixes for ordinary structural
satisfactory previous performance for target concrete. Unless otherwise specified, the concrete
mean strength, current margin, workability mix shall be as detailed in Table 2.
and water/cement ratio, or
The material shall comply with the requirements
2) full details of tests on trial mixes carried out of 3.2 and, prior to the production of concrete, the
in accordance with 3.6.3, or contractor shall submit for the engineers approval
3) alternatively for ordinary structural details of the nature and source of each material.
concrete, a statement that, for initial Similar details shall be provided before substantial
production, the appropriate mix proportions changes are made in the materials to be used and, if
given in Table 2 will be used; required by the engineer, the contractor shall
c) the quantities of each material per cubic metre demonstrate the adequacy of the mix by means of
of fully compacted concrete. trial mixes and tests.
BSI 12-1998 3
BS 5400-7:1978
3.7.2 Prescribed mixes for special structural 3.8.2 Cement. Cement shall be stored in dry
concrete. The concrete mix shall comply with all weatherproof sheds with raised floors or in silos. If
the requirements described in the contract. in sheds, each consignment shall be kept separate
The material shall comply with the requirements and distinct. Any cement that has become
of 3.3 or 3.4. injuriously affected by damp or other causes shall be
removed from the site immediately.
3.8 Production of concrete
The contractor shall furnish, as directed by the
3.8.1 General. The contractor shall provide engineer, test certificates relating to the cement to
supervision to ensure the required standard of be used in the works. Each certificate shall indicate
control over materials and workmanship. results of tests and analysis by an approved firm
and shall state that the cement complies in all
respects with the requirements of the appropriate
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
4 BSI 12-1998
BS 5400-7:1978
3.8.3 Aggregate. Single-sized coarse aggregates The mixer shall comply with the requirements of
and fine aggregates shall be used, unless otherwise BS 1305 or BS 4251 where applicable. The mixing
authorized by the engineer, and stored in separate time shall be not less than that recommended by the
hoppers, or different stacks which shall be manufacturer, subject to the engineers approval of
separated from each other. Relative proportions of the trial mixes.
coarse aggregates to be used shall be determined on Mixers that have been out of use for more
the basis of the trial mixes. than 30 mm shall be thoroughly cleaned before any
All aggregates shall be kept free from contact with fresh concrete is mixed. Unless otherwise agreed by
deleterious matter With adequate provision for the engineer, the first batch of concrete through the
drainage, and shall be stored and handled so as to mixer shall then contain only two-thirds of the
avoid segregation. normal quantity of coarse aggregate. Mixing plant
The overall grading of the aggregates shall be such shall be thoroughly cleaned before changing from
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
as to produce concrete of the specified quality that one type of cement to another.
will work readily into position without segregation 3.8.5 Control of strength of designed mixes
and without the use of excessive water. The overall 3.8.5.1 Adjustment to mix proportions. Adjustments
grading shall be controlled throughout the work so to mix proportions shall be made subject to the
that it conforms closely to that assumed in the engineers approval, in order to minimize the
selection of the mix proportions. Each delivery shall variability of strength and to maintain the target
be inspected and, if required by the engineer, tested mean strength. Such adjustments shall not be taken
in accordance with BS 812. to imply any change in the current margin.
The contractor shall provide copies of the results of
3.8.5.2 Change of current margin. When required by
routine control tests carried out by the aggregate
the engineer, the contractor shall recalculate the
producer.
current margin in accordance with 3.6.1. The
3.8.4 Batching and mixing. The quantities of recalculated value shall be adopted as directed by
cement, fine aggregate and the various sizes of the engineer, and it shall become the current
coarse aggregate shall be measured by weight margin for concrete produced subsequently.
unless otherwise authorized by the engineer. 3.8.6 Ready-mixed concrete. Ready-mixed
A separate weighing machine shall be provided for concrete shall comply with the general
weighing the cement. Alternatively the cement may requirements of this specification and the following
be measured by using a whole number of bags in special requirements. The concrete shall be carried
each batch. in purpose-made agitators, operating continuously,
The quantity of water shall be measured. Any or truck mixers. The concrete shall be compacted
admixture to be added shall be measured and, if and in its final position within 2 h of the
solid, shall be measured by weight. Different types introduction of cement to the aggregate, unless a
of cement shall not be mixed. longer time is agreed by the engineer. The time of
such introduction shall be recorded on the Delivery
The batch weight of aggregate shall be adjusted to
allow for a moisture content typical of the aggregate Note together with the weight of the constituents of
being used. each mix.
All measuring equipment shall be maintained in a When truck-mixed concrete is used, water shall be
clean and serviceable condition; its accuracy shall be added under supervision either at the site or at the
checked over the range in use when set up at each central batching plant as agreed by the engineer,
site, and maintained thereafter. but in no circumstances shall water be added in
transit.
The accuracy of equipment shall fall within the
following limits: Unless otherwise agreed by the engineer, truck
mixer units and their mixing and discharge
Measurement of cement 3 % of the quantity of performance shall comply with the requirements of
BS 4251.
cement in each batch
Measurement of water 3 % of the quantity of
water in each batch
Measurement of 3 % of the total
aggregate quantity of aggregate
in each batch
Measurement of 5 % of the quantity of
admixture admixture in each
batch.
BSI 12-1998 5
BS 5400-7:1978
3.9 Compliance with specified requirements If only one cube result fails to meet the second
3.9.1 General. All sampling and testing of requirement b), then that result may be considered
constituent materials shall be carried out in to represent only the particular batch of concrete
accordance with the provisions of the appropriate from which that cube was taken.
British Standard. In particular, sampling and If the average strength of any group of four
testing of fresh and of hardened concrete shall be consecutive test cubes fails to meet the first
carried out in accordance with the provisions of requirement a), then all the concrete in all the
BS 1881 unless such provision is at variance with batches represented by all such cubes shall be
this specification. deemed not to comply with the strength
3.9.2 Strength requirements. For the purposes of this clause the
batches of concrete represented by a group of four
3.9.2.1 General. Compliance with the specified consecutive test cubes shall include the batches
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
characteristic strength shall be based on tests made from which samples were taken to make the first
on cubes at an age of 28 days unless there is and the last cubes in the group of four, together with
evidence, satisfactory to the engineer, that a all the intervening batches.
particular testing regime is capable of predicting the
3.9.2.3 Testing plan B. The contractor shall use
strength at 28 days of concrete tested at an earlier
testing plan B for single batches of concrete as
age.
directed by the engineer. One test cube shall be
Unless otherwise directed by the engineer, the rate made from each of two independent representative
of sampling shall be as given in Table 3, but not less samples taken from every batch of concrete selected
than one sample shall be taken on each day that for testing using plan B.
concrete of that grade is used.
The average strength of the two test cubes taken
Table 3 Rates of sampling and testing from the same batch of concrete shall exceed the
Rate of Sample from one batch selected specified characteristic strength by not less
Sampling randomly to represent an average
volume of not more than the lesser of:
than 2.0 N/mm2 or one-tenth of the specified
strength, whichever is the smaller.
Rate 1 10 m3 or 10 batches If the average strength of the test specimens taken
Rate 2 20 m3 or 20 batches to represent a given batch of concrete fails to meet
Rate 3 the appropriate requirement, the whole of that
50 m3 or 50 batches
batch of concrete represented by those specimens
3.9.2.2 Testing plan A. Each cube shall be made shall be deemed not to comply with the strength
from a single sample taken from a randomly requirements of the specification. Compliance with
selected batch of concrete. The samples shall be this requirement in respect of a given batch of
taken at the point of discharge from the mixer or, in concrete shall not be adduced as evidence of
the case of ready-mixed concrete, at the point of compliance in respect of any other batch.
discharge from the delivery vehicle. 3.9.2.4 Action to be taken in the event of
At least one sample shall be taken on each day that non-compliance with testing plans A and B. The
concrete of that particular grade is used. The times contractor shall take such remedial action as the
of day at which samples are taken shall be chosen at engineer may order, including the removal of the
random. relevant concrete, and shall, before proceeding with
For compliance purposes the concreting, submit for the engineers approval
details of the action proposed to ensure that the
a) the average strength determined from any concrete still to be placed in the works will comply
group of four consecutive test cubes shall exceed with the requirements of the specification.
the specified characteristic strength by not less
than 0.5 times the current margin; 3.9.3 Cement content. The cement content of any
batch of concrete shall be not less than the specified
b) each individual test result shall be greater minimum value less 5 % of that value, nor more
than 85 % of the specified characteristic strength. than the specified maximum value plus 5 % of that
The current margin shall be taken as 10 N/mm2 value.
for concrete of grade 15 or 15 N/mm2 for concrete of
grade 20 or above, unless in accordance with 3.6.1
or 3.8.5.2 a smaller margin has been established to
the satisfaction of the engineer.
6 BSI 12-1998
BS 5400-7:1978
3.9.4 Workability. The workability of the fresh 3.10.2 Control of colour. When specified, the
concrete shall be such that the concrete is suitable contractor shall obtain each constituent material
for the conditions of handling and placing from a single consistent source. The aggregates
(see 3.11.3) so that after compaction (see 3.11.3) it shall be durable and free of any impurities that may
surrounds all reinforcement, tendons and ducts and cause staining. The mix proportions and the
completely fills the formwork. Workability shall be grading, particularly of the fine aggregate, shall be
measured at least once a day using one of the maintained constant. In formwork the same type of
following tests in accordance with BS 1881, and plywood or timber shall be used throughout similar
shall be within the following limits of the required exposed areas, and individual plywood sheets or
values: sections of timber in large panels shall not be
replaced.
Slump 25 mm or one-third of the required 3.10.3 Release agents. Release agents for
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
value, whichever is the greater formwork shall be to the approval of the engineer.
Compacting 0.03, where the required value Where a concrete surface is to be permanently
factor is 0.90 or more exposed, only one agent shall be used throughout
0.04 where the required value is the entire area. Release agents shall be applied
between 0.80 and 0.90 evenly and contact with reinforcement and
0.05, where the required value prestressing tendons shall be avoided.
is 0.80 or less 3.10.4 Surface finishes for concrete. Unless
Vebe 3 s or one-fifth of the required otherwise specified, the surface finish shall be one of
value, whichever is the greater the following.
3.9.5 Water/cement ratio. The water/cement ratio Type A finish. This finish shall be obtained by the
of a batch of concrete shall not exceed the specified use of properly designed formwork or moulds of
maximum value by more than 5 % of that value. closely jointed sawn boards. The surface shall be
free from voids, honeycombing or other large
3.9.6 Air content of fresh concrete. The blemishes.
percentage air content determined from individual
Type B finish. This finish shall be obtained by the
samples taken at the point of placing the concrete
and representative of any given batch of concrete use of properly designed forms of closely jointed
shall be within 1.5 % of the specified value. The wrought boards. Alternatively, steel or other
suitable material may be used for the forms. The
average percentage air content from any four
surface shall be free from voids, honeycombing or
consecutive determinations from separate batches
other large blemishes.
shall be within 1.0 % of the specified value.
Type C finish. This finish shall be obtained by
3.9.7 Additional tests on concrete for special
using properly designed forms having a hard,
purposes. When required by the engineer,
smooth surface. The concrete surfaces shall be
additional cubes shall be made and tested in
smooth with true, clean arrises. Only very minor
accordance with BS 1881. The method of sampling,
surface blemishes shall be permitted and there shall
identification and storage of the concrete cubes shall
be no staining or discoloration.
be as directed by the engineer.
Type D finish. This finish shall be obtained by first
3.10 Surface finish of concrete producing a type B finish on thoroughly
3.10.1 Trial panels. When required by the compacted, high-quality concrete cast in properly
engineer, the contractor shall prepare, prior to designed forms. The surface shall then be improved
concreting, a sample panel of size and surface by carefully removing all fins and other projections,
texture to be agreed by the engineer. The panel shall thoroughly washing down and then filling the most
contain reinforcement fixed to represent the most noticeable surface blemishes with a cement and fine
congested part of the work. The panel shall be filled aggregate paste. Consistency of the colour of the
with the proposed concrete mix compacted by the concrete shall be to the approval of the engineer.
method to be used in the work. As soon as
practicable after compaction, the side forms shall be
removed to enable the engineer to check the surface
finish and compaction achieved.
BSI 12-1998 7
BS 5400-7:1978
Type E finish. This finish shall be obtained by first Formwork (including supports) shall be sufficiently
producing a type C finish and then, while the rigid to maintain the forms in their correct position,
concrete is still green, filling all surface blemishes shape and profile within the limits of the
with a fresh, specially prepared cement and fine dimensional tolerances where specified. The
aggregate paste. Consistency of the colour of the supports shall be designed to withstand the worst
concrete shall be to the approval of the engineer. combination of self-weight, formwork weight,
After the concrete has been properly cured, the faces formwork forces, reinforcement weight, wet
shall be rubbed down where necessary to produce a concrete weight, construction and wind loads,
smooth and even surface. together with all incidental dynamic effects caused
3.10.5 Protection. permanently exposed surfaces by placing, vibrating and compacting the concrete.
shall be protected from spillage, stains and damage The formwork shall be so arranged as to be readily
of any sort. dismantled and removable from the cast concrete
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
8 BSI 12-1998
BS 5400-7:1978
All placing shall be carried out under the direct 3.11.4.2 Striking period. Where the concrete
supervision of a competent member of the compressive strength is confirmed by tests on
contractors staff. Concreting operations shall not be concrete cubes stored under conditions that
permitted to displace reinforcement, tendon ducts, simulate the field conditions, formwork supporting
tendon anchorages or formwork or to damage the concrete in bending may be struck when the cube
faces of formwork. strength is 10 N/mm2 or twice the stress to which it
Concrete shall be thoroughly compacted by will be subjected, whichever is the greater.
vibration, unless otherwise agreed by the engineer, In the absence of control cubes, the periods before
during the operation of placing, and thoroughly striking shall be as the engineer directs.
worked around the reinforcement, tendons or duct 3.11.5 Curing of concrete
formers, around embedded fixtures and into corners
of the formwork to form a solid mass free from voids. 3.11.5.1 Curing methods. The method of curing
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
When vibrators are used to compact the concrete, shall prevent loss of moisture from the concrete.
vibration shall be applied continuously during the Immediately after compaction and for 7 days
placing of each batch of concrete until the expulsion thereafter, except where elevated temperature
of air has practically ceased and in a manner that curing is used, concrete shall be protected against
does not promote segregation of the ingredients. harmful effects of weather, including rain, rapid
temperature changes and frost, and from drying
Particular care shall be taken when concreting
out.
bridge decks of substantial thickness to avoid
layering of concrete, and the whole thickness shall The curing time shall be the number of days given
be placed in one pass. In deck slabs where void in Table 4 unless the average temperature of the
formers are used, adequate means to prevent concrete during the required number of days falls
flotation shall be employed and care taken to ensure below 10 C, in which case the period of curing shall
adequate compaction of the concrete placed beneath be extended until the maturity of the concrete
the void formers. reaches the value given in the table.
A sufficient number of vibrators in serviceable Details of all curing methods used shall be subject to
condition shall be on site to ensure that spare the approval of the engineer.
equipment is always available in the event of 3.11.5.2 Accelerated curing. Elevated-temperature
breakdowns. curing may be used only with ordinary Portland
Internal vibrators shall be capable of producing not cement. After the completion of the placing of the
less than 10 000 cycles per minute, and external concrete, 4 h shall elapse before its temperature is
vibrators not less than 3 000 cycles per minute. raised. The rise in temperature within any period
Vibration shall not be applied by way of the of 30 min shall not exceed 10 C and the maximum
reinforcement. Where vibrators of the immersion temperature attained shall not exceed 70 C. The
type are used, contact with reinforcement and all rate of subsequent cooling shall not exceed the rate
inserts shall be avoided. of heating.
Concrete shall not be subjected to disturbance The use of accelerated curing methods for concrete
between 4 h and 24 h after compaction. containing other types of cement or any admixture
shall be subject to the engineers approval.
Whenever vibration has to be applied externally,
the design of formwork and disposition of vibrators 3.11.6 Cold weather work. When concrete is
shall ensure efficient compaction and the avoidance placed at air temperatures below 2 C, the following
of surface blemishes. requirements shall be met.
The mix shall be such that there will be no excess a) The aggregates and water used in the mix shall
water on the top surface on completion of be free from snow, ice and frost.
compaction. b) The surface temperature of the concrete at the
3.11.4 Striking of formwork time of placing shall be at least 5 C and shall not
exceed 30 C.
3.11.4.1 General. The removal shall be done in such
a manner as not to damage the concrete, and shall c) The surface temperature of the concrete shall
take place at times to suit the requirements for its be maintained at not less than 5 C until it
curing and to prevent restraint that may arise from reaches a strength of 5 N/mm2 as determined by
elastic shortening, shrinkage or creep. tests on cubes that were cured under identical
conditions to the structural concrete.
BSI 12-1998 9
BS 5400-7:1978
d) Before placing concrete, the formwork, Where the engineer requires tests to be carried out,
reinforcement, prestressing steel and any surface no members to which the tests relate shall be
with which the fresh concrete will be in contact dispatched to the site until the tests have been
shall be free from snow, ice and frost. satisfactorily completed.
e) Cement shall not be allowed to come into All members shall be indelibly marked to show the
contact with water at a temperature greater Member Mark as described in the contract, the
than 60 C. production line on which they were manufactured,
3.11.7 Hot weather work. During hot weather the the date on which the concrete was cast and, if they
contractor shall ensure that the constituent are symmetrical section, the face that will be
materials of the concrete are sufficiently cool to uppermost when the member is in its correct
prevent the concrete from stiffening in the interval position in the works. The markings shall be so
between its discharge from the mixer and located that they are not exposed to view when the
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
10 BSI 12-1998
BS 5400-7:1978
3.11.8.4 Assembly and erection. The method of 3.12.4 Grouting equipment. The mixing
assembly and erection described in the contract equipment shall produce a grout of homogeneous
shall be strictly adhered to on site. Immediately a consistency and shall be capable of providing a
unit is in position, and before the lifting equipment continuous supply to the injection equipment.
is removed, temporary supports or connections The injection equipment shall be capable of
between members, as necessary, shall be provided. continuous operation with little variation of
The final structural connections shall be completed pressure and shall include a system for
as soon as is practicable. recirculating the grout while actual grouting is not
3.11.8.5 Forming structural connections. No in progress. Compressed air shall not be used.
structural connections shall be made until the The equipment shall have a sensibly constant
engineers approval has been given. delivery pressure not exceeding 1 N/mm2. All piping
Unless otherwise agreed by the engineer, the to the grout pump shall have a minimum of bends,
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
composition and water/cement ratio of the in-situ valves and changes in diameter. All baffles to the
concrete or mortar used in any connection and the pump shall be fitted with 1.18 mm sieve strainers.
packing of joints shall be in accordance with the All equipment, especially piping, shall be
assembly instructions. thoroughly washed through with clean water after
Levelling devices shall only be released or removed every series of operations and at the end of use for
with the engineers approval. each day. The interval between washings shall not
exceed 3 h.
3.11.8.6 Protection. At all stages of construction,
The equipment shall be capable of maintaining
precast concrete units and other concrete associated
pressure on completely grouted ducts and shall be
therewith shall be properly protected to prevent
fitted with a valve that can be locked off without loss
damage to permanently exposed concrete surfaces,
of pressure in the duct.
especially arrises and decorative features.
3.12.5 Mixing. Water shall be added to the mixer
3.12 Grouting of prestressing tendons
first, then the cement. When these are thoroughly
3.12.1 General. The contractor shall undertake mixed, the admixture, if any, shall be added. Mixing
grouting trials when required by the engineer. shall continue until a uniform consistency is
3.12.2 Materials. Unless otherwise directed or obtained. The water/cement ratio of the mix shall
agreed by the engineer as a result of grouting trials, not exceed 0.45 by weight unless otherwise agreed
the grout shall consist only of ordinary Portland by the engineer. Mixing shall not be by hand.
cement and water. The water/cement ratio shall be 3.12.6 Injecting grout. Grouting shall be carried
as low as possible consistent with the necessary out as soon as is practicable after the tendons in
workability. them have been stressed and the engineers
The grout shall not be subject to bleeding in excess permission to commence has been obtained.
of 2 % after 3 h or 4 % maximum when measured Injection shall be continuous, and it shall be slow
at 18 C in a covered cylinder enough to avoid producing segregation of the grout.
approximately 100 mm diameter with a height of The method of injecting grout shall ensure complete
grout of approximately 100 mm, and the water shall filling of the ducts and complete surrounding of the
be reabsorbed by the grout during the 24 h after steel. Grout shall be allowed to flow from the free
mixing. end of the duct until its consistency is equivalent to
Admixtures may be used with the written that of the grout injected. The opening shall then be
permission of the engineer and shall be applied firmly closed. Any vents shall be closed in a similar
strictly in accordance with the manufacturers manner one after another in the direction of the
instructions. flow. After an appropriate time, further injections
shall be carried out to fill any possible cavities.
Dry materials shall be measured by weight.
The injection tubes shall then be sealed off under
3.12.3 Ducts. Air vents shall be provided at any pressure until the grout has set.
crests in the duct profile and elsewhere as specified.
The filled ducts shall not be subjected to shock or
All ducts shall be thoroughly clean before grouting. vibration within 1 day of grouting.
Ducts formed without metal sheathing shall be
Not less than 2 days after grouting, the level of
provided with effective drainage and, unless
grout in the injection and vent tubes shall be
otherwise directed by the engineer, shall be flushed
inspected and made good as necessary.
with water before grouting. All surplus water shall
be removed by compressed air injection. All
anchorages shall be sealed or fitted with grouting
connections.
BSI 12-1998 11
BS 5400-7:1978
The contractor shall keep full records of grouting Any reinforcement bar that has already been bent
including the date each duct was grouted, the shall not be rebent at the location of the original
proportion of the grout and any admixtures used, bend without the engineers permission.
the pressure, details of any interruptions and 4.3
topping up required. Copies of these records shall be 4.4 Fixing. Reinforcement shall be secured against
supplied to the engineer within 3 days of grouting. displacement. Unless specified otherwise, the actual
concrete cover shall be not less than the required
Where required by the engineer, the contractor shall nominal cover minus 5 mm.
provide facilities and attendance for the
radiographic testing of ducts. In a member where the nominal cover is
dimensioned to the links, spacers between the links
3.12.7 Grouting during cold weather. When the and formwork shall be the same dimensions as the
weather is cold, accurate temperature records shall nominal cover.
be kept covering maximum and minimum air
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
temperatures, and temperatures of the structures to Cover blocks required for ensuring that the
be grouted. No materials in which frost or ice is reinforcement is correctly positioned shall be as
present shall be used, and the ducts and equipment small as possible consistant with their purpose, of a
shall be completely free of frost and ice. shape acceptable to the engineer and designed so
that they will not overturn when the concrete is
No grout shall be placed when the temperature of placed. They shall be made of concrete with 10 mm
the structure is below 5 C, or is likely to fall maximum aggregate size and they shall be of the
below 5 C during the next 48 h, unless the member same strength and material source as the adjacent
is heated so as to maintain the temperature of the concrete. Wire cast in the block for the purpose of
placed grout above 5 C for at least 48 h. tying it to the reinforcement shall be as described in
Ducts shall not be warmed with steam unless the contract. Stainless steel tying wire shall be used
accompanied by general heating of the member or in cover blocks to exposed surfaces.
structure externally. Other types of spacers may be used only with the
3.12.8 Strength of grout. The compressive approval of the engineer. Pieces of wood, metal, tile
strength of 100 mm cubes made of the grout shall or porous material shall not be used as cover blocks.
exceed 17 N/mm2 at 7 days. Cubes shall be cured in Projecting ends of ties or clips shall not encroach
a moist atmosphere for the first 24 h, and into the concrete cover. Tying wires shall be either
subsequently in water. a) 1.6 mm diameter soft annealed iron wire for
unexposed surfaces, or
4 Reinforcement
b) 1.2 mm diameter stainless steel wire for in situ
4.1 Material exposed surfaces.
4.1.1 Hot rolled bars. Hot rolled mild steel bars The position of reinforcement shall be checked
and hot rolled high yield bars shall comply with the before and during concreting.
requirements of BS 4449.
4.5 Surface condition. Immediately before
4.1.2 Cold worked bars. Cold worked steel bars concrete is placed around it, reinforcement shall be
shall comply with the requirements of BS 4461. clean, free from mud, oil, paint, retarders, loose
4.1.3 Hard drawn steel wire. Hard drawn mild rust, loose mill scale, snow, ice, grease or any other
steel wire shall comply with the requirements of substance that can be shown to affect adversely the
BS 4482. steel or concrete chemically, or to reduce the bond.
4.1.4 Steel fabric. Steel fabric reinforcement shall 4.6 Laps and joints. Laps and joints including
comply with the requirements of BS 4483 and shall sleeving, threading and other mechanical
be delivered to the site in flat mats. connections shall be made only by the methods
specified and at the positions shown on the
4.1.5 Bond strength. The classification of deformed
drawings or as agreed by the engineer.
bars as type (1) or (2) for bond strength shall be in
accordance with appendix E of CP 110-1:1972.
4.2 and 4.3 Bar schedule dimensions; cutting
and bending. Reinforcement shall be scheduled in
accordance with BS 4466 and shall be cut or cut and
bent to the dimensions specified in the contract.
Bending at temperatures below 5 C or in excess
of 100 C may only be carried out with the
engineers approval and under his supervision.
12 BSI 12-1998
BS 5400-7:1978
accordance with BS 5135 and the recommendations as galvanizing. This does not preclude cutting as
of the reinforcement manufacturers, subject to the specified in 5.5.
approval of the engineer and the satisfactory
performance of trial joints. 5.3 Surface condition. Prestressing tendons and
internal and external surfaces of sheaths or ducts
4.7.4 Other methods. Other methods of welding shall be clean and free from pitting, loose rust and
may be used subject to the approval of the engineer loose scale at the time of incorporation in the work.
and to their satisfactory performance in trial joints.
5.4 Straightness
4.7.5 Location of welded joints. Welded joints
shall not be made at bends in reinforcement. Unless 5.4.1 Wire. Unless otherwise agreed by the
otherwise agreed by the engineer, joints in parallel engineer, low relaxation and normal relaxation wire
bars of the principal tensile reinforcement shall be shall be in coils of sufficiently large diameter to
staggered in the longitudinal direction at a distance ensure that the wire pays off straight.
not less than the end anchorage length for the bar. 5.4.2 Strand. Prestressing strand, however
4.7.6 Strength of structural welded joints. The manufactured, shall be in coils of sufficiently large
strength of all structural welded joints shall be diameter to ensure that the strand pays off
assessed following tests on trial joints to reasonably straight.
demonstrate that they achieve the strength of the 5.4.3 Bars. Prestressing bars as-delivered shall be
bar. straight. Any small adjustments for straightness
that are necessary on site shall be made by hand
5 Prestressing tendons under the supervision of the engineer. Bars bent in
the threaded portion shall be rejected. Any
5.1 Materials
straightening of bars shall be carried out cold but at
5.1.1 Steel wire. Steel wire shall comply with the a temperature of not less than 5 C. Any necessary
requirements of BS 2691. heating shall be by means of steam or hot water.
5.1.2 Cold worked high tensile alloy bar. Cold 5.5 Cutting. All cutting of wire, strand or bar shall
worked high tensile alloy steel bars for prestressed be carried out using either
concrete shall comply with the requirements of
a) a high-speed abrasive cutting wheel, friction
BS 4486.
saw or any other mechanical method approved by
5.1.3 Stress-relieved seven-wire strand. the engineer, or
Stress-relieved seven-wire strand shall comply with
b) an oxy-acetylene cutting flame, using excess
the requirements in BS 3617 or have properties that
oxygen to ensure a cutting rather than a melting
are not inferior.
action. Care shall be taken that neither the flame
5.1.4 Nineteen-wire strand. Nineteen-wire steel nor splashes come into contact with either the
strand shall comply with the requirements of anchorage or other tendons.
BS 4757. In post-tensioning systems, the cutting action as
5.1.5 Testing. Where directed by the engineer, the in a) and b) shall be not less than one diameter from
contractor shall arrange for samples of the steel the anchor, and the temperature of the tendon
intended for use in the works to be tested at an adjacent to the anchor shall be not greater
approved independent testing laboratory. than 200 C.
BSI 12-1998 13
BS 5400-7:1978
5.6 Positioning of tendons, sheaths and duct 5.7.3 Pretensioning. Where pretensioning
formers. The tendons, sheaths and duct formers methods are used, the tension shall be fully
shall be accurately located and maintained in maintained by some positive means during the
position both vertically and horizontally as shown period between tensioning and transfer. The
on the drawings. Unless otherwise shown on the transfer of stress shall take place slowly to minimize
drawings, the tolerance in the location of the centre shock.
line of sheath or duct shall be 5 mm. 5.7.3.1 Straight tendons. In the long-line method of
5.7 Tensioning the tendons pretensioning, sufficient locator plates shall be
5.7.1 General. All wires, strands or bars stressed in distributed throughout the length of the bed to
one operation shall be taken, where possible, from ensure that the wires or strands are maintained in
the same parcel. Each cable shall be tagged with its their proper position during concreting. Where a
number from which the coil numbers of the steel number of units are made in line, they shall be free
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
used can be identified. Cables shall not be kinked or to slide in the direction of their length and thus
twisted. Individual wires and strands for which permit transfer of the prestressing force to the
extensions are to be measured shall be readily concrete along the whole line.
identifiable at each end of the member. No strand In the individual mould system, the moulds shall be
that has become unravelled shall be used. sufficiently rigid to provide the reaction to the
5.7.2 Tensioning apparatus. The tensioning prestressing force without distortion.
apparatus shall meet the following general 5.7.3.2 Deflected tendons. Where possible the
requirements. mechanisms for holding down or holding up tendons
a) The means of attachment of the tendon to the shall ensure that the part in contact with the tendon
jack or tensioning device shall be safe and secure. is free to move in the line of the tendon so that
frictional losses are nullified. If, however, a system
b) Where two or more wires or strands are is used that develops a frictional force, this force
stressed simultaneously, they shall be shall be determined by test and due allowance
approximately of equal length between made.
anchorage points at the datum of load and
extension measurement. The degree of variation For single tendons the deflector in contact with the
shall be small compared with the expected tendon shall have a radius of not less than 5 times
extension. the tendon diameter for wire or 10 times the tendon
diameter for a strand, and the total angle of
c) The tensioning apparatus shall be such that a
deflection shall not exceed 15
controlled total force is imposed gradually and no
dangerous secondary stresses are induced in the The transfer of the prestressing force to the concrete
tendons, anchorage or concrete. shall be effected in conjunction with the release of
hold-down and hold-up forces as approved by the
d) The force in the tendons during tensioning
engineer.
shall be measured by direct-reading load cells or
obtained indirectly from gauges fitted in the 5.7.4 Post-tensioning
hydraulic system to determine the pressure in 5.7.4.1 Arrangement of tendons. Where wires,
the jacks. Facilities shall be provided for the strands or bars in a tendon are not stressed
measurement of the extension of the tendon and simultaneously, the use of spacers shall be in
of any movement of the tendon in the gripping accordance with the recommendations of the system
devices. The load-measuring device shall be manufacturer.
calibrated to an accuracy within 2 % and
5.7.4.2 Anchorages. Anchorages shall be tested in
checked at intervals to the approval of the
accordance with the requirements of BS 4447.
engineer. Elongation of the tendon shall be
measured to an accuracy within 2 % or 2 mm, For each anchorage system used in the works, the
whichever is the more accurate. characteristic value for anchorage efficiency shall be
e) The tensioning equipment shall be calibrated not less than 90 %.
before the tensioning operation and at intervals Proprietary anchorages shall be handled and used
to the approval of the engineer. strictly in accordance with the manufacturers
instructions and recommendations.
14 BSI 12-1998
BS 5400-7:1978
5.7.4.3 Deflected tendons. The deflector in contact Stressing shall continue until the required
with the tendon shall, where possible, have a radius extension and tendon load are reached or are to the
of not less than 50 times the diameter of the tendon, engineers satisfaction.
and the total angle of deflection shall not exceed 15. The extension shall allow for any draw-in of the
Where the radius is less than 50 times the diameter tendon occurring at the non-jacking end, but
of the tendon and the angle of deflection measurement shall not commence until any slack in
exceeds 15, the loss of strength of the tendon shall the tendon has been taken up.
be determined by test and due allowance made.
After the tendons have been anchored, the force
5.7.4.4 Tensioning procedure. Before tensioning, exerted by the tensioning apparatus shall be
where the design permits, the contractor shall decreased gradually and steadily so as to avoid
demonstrate that all tendons are free to move in the shock to the tendon or the anchorage. Full records
ducts. Tensioning shall be carried out under shall be kept of all tensioning operations, including
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
competent supervision in such a manner that the the measured extensions, pressure-gauge or
stress in the tendons increases at a gradual and load-cell readings, and the amount of draw-in at
steady rate. Tensioning shall not be carried out at a each anchorage. Copies of these records shall be
temperature below 0 C without the approval of the supplied to the engineer within 24 h of each
engineer. tensioning operation.
The supervisor in charge of stressing shall be Unless otherwise agreed by the engineer, tendons
provided with particulars of the required tendon shall not be cut less than 3 days after grouting.
loads, order of stressing and extensions. Allowance 5.8 Protection and bond of prestressing
shall be made during stressing for the friction in the tendons. The prestressing tendons shall be
jack and in the anchorage, although the former is
protected in their permanent positions from both
not necessary when using load cells.
mechanical damage and corrosion in accordance
Any allowance for draw-in of the tendon during with the requirements of the contract.
anchoring shall be in accordance with the engineers
instructions.
BSI 12-1998 15
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
16
blank
BS 5400-7:1978
BSI 12-1998
|
|
|
|
|
|
|
|
|
BSI British Standards Institution
|
|
|
|
|
|
| BSI is the independent national body responsible for preparing British Standards. It
|
| presents the UK view on standards in Europe and at the international level. It is
| incorporated by Royal Charter.
|
|
| Revisions
|
|
| British Standards are updated by amendment or revision. Users of British Standards
|
| should make sure that they possess the latest amendments or editions.
|
|
| It is the constant aim of BSI to improve the quality of our products and services. We
|
| would be grateful if anyone finding an inaccuracy or ambiguity while using this
| British Standard would inform the Secretary of the technical committee responsible,
|
| the identity of which can be found on the inside front cover. Tel: 020 8996 9000.
|
| Fax: 020 8996 7400.
Licensed Copy: Sheffield University, University of Sheffield, 18 December 2002, Uncontrolled Copy, (c) BSI
|
|
| BSI offers members an individual updating service called PLUS which ensures that
|
| subscribers automatically receive the latest editions of standards.
|
|
| Buying standards
|
| Orders for all BSI, international and foreign standards publications should be
|
| addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001.
|
|
| In response to orders for international standards, it is BSI policy to supply the BSI
|
| implementation of those that have been published as British Standards, unless
|
| otherwise requested.
|
|
| Information on standards
|
| BSI provides a wide range of information on national, European and international
|
| standards through its Library and its Technical Help to Exporters Service. Various
|
| BSI electronic information services are also available which give details on all its
|
| products and services. Contact the Information Centre. Tel: 020 8996 7111.
|
| Fax: 020 8996 7048.
|
|
| Subscribing members of BSI are kept up to date with standards developments and
| receive substantial discounts on the purchase price of standards. For details of
|
| these and other benefits contact Membership Administration. Tel: 020 8996 7002.
|
| Fax: 020 8996 7001.
|
|
| Copyright
|
|
| Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of
|
| the publications of the international standardization bodies. Except as permitted
| under the Copyright, Designs and Patents Act 1988 no extract may be reproduced,
|
| stored in a retrieval system or transmitted in any form or by any means electronic,
|
| photocopying, recording or otherwise without prior written permission from BSI.
|
|
| This does not preclude the free use, in the course of implementing the standard, of
|
| necessary details such as symbols, and size, type or grade designations. If these
|
| details are to be used for any other purpose than implementation then the prior
| written permission of BSI must be obtained.
|
|
| If permission is granted, the terms may include royalty payments or a licensing
|
| agreement. Details and advice can be obtained from the Copyright Manager.
|
| Tel: 020 8996 7070.
|
|
|
|
|
|
|
|
|
BSI |
|
389 Chiswick High Road |
|
London |
|
W4 4AL |
|
|
|
|
|
|