A B 350 C D E F G

MIN

MULTI UNIT DEVELOPMENT


GROUND FLOOR SLAB

Fall
CW1
OVER
CW1
OVER
CW1
OVER
CW1
OVER
BC1
OVER
GENERAL ARRANGEMENT PLAN
01
450 DENOTES SLAB THICKNESS

Step
Step
420 CONCRETE GRADE = N40
Step Step Fall 350
420 C MIN
COVER TO REINFORCEMENT
D S211
Step
INTERNAL - 20 TOP AND BOTTOM
CC1 S211
UNDER 420 EXTERNAL - 40 TOP, 20 BOTTOM
450
CC1
Step
LEGEND
UNDER CC1 800x300 CONCRETE COLUMN, REFER DRG. No. 16157/S111 FOR DETAILS.

Step
Step

UNDER
CC1
Step CW1 190 THICK CONCRETE WALL, REFER SECTION C ON DRG. No. 16157/S211.
02 F

Step
Step
EF1 SLAB EDGE FOOTING, REFER DRG. No. 16157/S211 FOR DETAILS.
S211 EF2 SLAB EDGE FOOTING, REFER SECTION A ON DRG. No. 16157/S211.
Step
420 Step
EF3 SLAB EDGE FOOTING, REFER DRG. No. 16157/S211 FOR DETAILS.
RW5

450 420 IF1 SLAB INTERNAL FOOTING, REFER DRG. No. 16157/S211 FOR DETAILS.
PWF1 SLAB PARTY WALL FOOTING, REFER SECTION A ON DRG. No. 16157/S211.
B CC1
UNDER RETAINING WALL RW2. PF1 PAD FOOTING, REFER DRG. No. 16157/S211 FOR DETAIL.
S211 Step REFER DWG. No. 16157/S101.
Step RW3 RETAINING WALL, REFER SECTION K ON DRG. No. 16157/S211.
Step
420
420 RW4 RETAINING WALL, REFER DRG. No. 16157/S212 FOR DETAILS.
350

Step
MIN CC1 RW5 RETAINING WALL, REFER DRG. No. 16157/S212 FOR DETAILS.

UNDER
Fall UNDER 420 Step

CC1
SF1 RW6 RETAINING WALL, REFER DRG. No. 16157/S212 FOR DETAILS.

Step
SF1 STRIP FOOTING, REFER DRG. No. 16157/S212 FOR DETAILS.
Step
E SF1
1000x450 MASS
DENOTES CONCRETE COLUMN UNDER.
420 S211 DENOTES CONCRETE COLUMN OVER.

SF1
CONCRETE BACK
DENOTES LOAD BEARING BLOCKWORK UNDER.

SJ2
HOE PIER.
03 350 DENOTES BLOCKWORK OVER.

Step
Step MIN RW4
SJ2
450 Fall
H

RW4
420
Step Step
S211
J BAR LAP & COG SCHEDULE
CW1 350 CW1 S211 RW4 BAR SIZE LAP LENGTH COG LENGTH
SJ2
Step

Step
RW5 OVER MIN OVER N12 500 160
04 CW1 N16 600 190
OVER CC1 N20 800 220
UNDER CC1 G PATH SLAB

SJ2
SJ2

SJ2

SJ2

SJ2

SJ2

SJ2

SJ2

SJ2

SJ2

SJ2
UNDER RW3 N24 1000 250
S211

SF1 Step NOTE:


Fall
RW5

Soffit 350 FOR ALL STEPS AND FALLS REFER


step ARCHITECTURAL DRAWINGS.

7/450 DIA. BORED PIERS TO FOUND 300 MIN. 300


BELOW MULTI UNIT BASEMENT FOOTING. MIN K
Soffit
TOWNHOUSE & HOUSE

Soffit
REINFORCE WITH 4/N16 VERTICAL AND R10 Step

Step
step

step
300 S211
RW5

SPIRAL AT 250 PITCH.

05
RW5
RW12 RELOCATION SLAB ON GROUND

1
PF
PF
EF2 EF2 EF2 M PF
1 100 DENOTES SLAB THICKNESS

PF
PF

PF

PF

PF
1

1
1

1
S212
EF1

IF1

IF1

CONCRETE GRADE = N20


SJ2 PF REINFORCE SLAB WITH SL82 MESH IN CENTRE.

PF

PF

PF

PF
1 EXISTING CAST SLAB ON VAPOUR BARRIER OVER 25mm SAND

1
IF1 IF1 RETAINING
BEDDING.
A
EF1

1 WALL
PF

1
DENOTES 150 THICK SLAB ON GROUND

PF

PF

PF

PF
S211 1
100 SJ2 PF REINFORCE WITH SL82 MESH TOP AND BOTTOM.
1 DENOTES 1 STRIP OF 3-L11TM TRIMMER x 1500 LONG.
PF
IF1

TOP.
EF1

RW6
IF1

FOOTINGS
IF1 IF1 REFER DETAILS AND SECTIONS FOR SIZE AND
SJ2 1
PF

1
PF

PF

PF

PF
EF1 REINFORCEMENT.
EF1

SJ2
IF1

1
CONCRETE GRADE = N25

PF
PWF1 PWF1 PWF1 PWF1
SJ2
06 1
200 PF
SF1

RW5

PF
EF1

1
IF1

IF1

PF
1

1
PF 1

PF

PF
SJ2 EF1 EF3
L PF
1
IF1 IF1 S212
EF1

100
SJ2
EF1

1 IF1
IF1

PF

1
PF

PF
EF1

1
IF1

RW6
RW5

PF

1
PF
IF1 IF1

EF3
SJ2 100 EXISTING
EF1 RETAINING
EF1

SJ2
IF1

EF1 WALL
PWF1 PWF1 PWF1 PWF1
SJ2 1
07 PF
1

1
PF
PF

PF
1

1
PF
1
PF
EF1

IF1

IF1

SF1

1
PF
SJ2 PATH SLAB
1
PF

EF3
IF1 IF1
EF1

RW5
100 SJ2 RW5
PF

PF

PF

PF
1

1
IF1
EF1

IF1

IF1 IF1
SJ2
EF1
SJ2

SJ2

08
RW5 RW4 RW5

J K L M N

E AMENDMENTS AS CLOUDED 05.07.17 P.D.


1:100 PROPOSED RESIDENTIAL DEVELOPMENT GROUND FLOOR SLAB GENERAL
D CONSTRUCTION ISSUE 23.06.17 P.D.
D.T. W.J. ARRANGEMENT PLAN
C AMENDMENTS AS CLOUDED 09.06.17 P.D.

B TENDER ISSUE 03.03.17 P.D. P.D. FEB '17

A PRELIMINARY 10.02.17 P.D.

16157 S201 E