An RRU3256, which is a remote radio unit for LTE TDD, supports four carriers.

Supported Modes and Frequency Bands


The following table lists the modes and frequency bands supported by an RRU3256.

Table 1 Modes and frequency bands supported by an RRU3256

Type Mode Frequency Band (MHz) Frequency Range (MHz)

RRU3256 LTE TDD 2300 (Band 40) 2300 to 2400

2500 (Band 41) 2496 to 2690

2600 (Band 38) 2570 to 2620

3500 (Band 42/43) 3400 to 3700

RF Specifications
Table 2 lists radio frequency (RF) specifications of an RRU3256.

NOTE:
ATBR in the RX and TX Channels column indicates that this RF module has A transmit channels and B
receive channels.
C x D W in the Output Power column indicates that this RF module is configured with C transmit channels and
the maximum output power of each transmit channel is D W.
Table 2 RF specifications of an RRU3256

Type Transmit Capacity Output Power Power Consumption


and Receive
Channels

RRU3256 4T4R Four carriers. The The RRU3256 See the RRU3256
bandwidth per carrier is supports the maximum sheet in 3900 Series
5, 10, 15, or 20 MHz. power configuration 4 Base Station Power
Consumption
x 30 W. The typical
Specifications.
configurations are as
follows:
Output power for the
RRU3256 (LTE TDD,
2300 MHz or 2500
MHz)
Output power for the
RRU3256 (LTE TDD,
3500 MHz)
For typical PA
configurations, see
Typical Power
Configuration for
RRU3256 in 3900
Series Base Station
Initial Configuration
Guide.

NOTE:
The output power of an RRU3256 working at 3500 MHz varies with the factors such as uplink-downlink
subframe configuration, filter insertion loss, and carrier configuration (contiguous or non-contiguous carriers).
When the frequency spacing between carriers is greater than 80 MHz, the rated output power of RF channels
must be decreased.
The output power per carrier in the output power table provides the maximum output power possible while
ensuring the network performance.

Table 3 Output power for the RRU3256 (LTE TDD, 2300 MHz or 2500 MHz)

Working mode Total Number of LTE Output Power per LTE Bandwidth of LTE TDD
TDD Carriers TDD Carrier (W) Carrier (MHz)

LTE TDD 1 (MIMO) 2 x 30 5,10,15,20

2 (MIMO) 2 x 15 5,10,15,20

3 (MIMO) 2 x 10 5,10,15,20
Table 3 Output power for the RRU3256 (LTE TDD, 2300 MHz or 2500 MHz)

Working mode Total Number of LTE Output Power per LTE Bandwidth of LTE TDD
TDD Carriers TDD Carrier (W) Carrier (MHz)

4 (MIMO) 2 x 7.5 5,10,15,20

1 (MIMO) 4 x 30 5,10,15,20

2 (MIMO) 4 x 15 5,10,15,20

3 (MIMO) 4 x 10 5,10,15,20

4 (MIMO) 4 x 7.5 5,10,15,20

Table 4 Output power for the RRU3256 (LTE TDD, 3500 MHz)

Working mode Total Number of LTE Output Power per LTE Bandwidth of LTE TDD
TDD Carriers TDD Carrier (W) Carrier (MHz)

LTE TDD 1 (MIMO) 2 x 15 5,10,15,20

2 (MIMO) 2 x 7.5 5,10,15,20

3 (MIMO) 2x5 5,10,15,20

4 (MIMO) 2 x 3.75 5,10,15,20

1 (MIMO) 4 x 15 5,10,15,20

2 (MIMO) 4 x 7.5 5,10,15,20

3 (MIMO) 4x5 5,10,15,20

4 (MIMO) 4 x 3.75 5,10,15,20

Engineering Specifications
The following table lists the equipment specifications of an RRU3256.
Table 5 Equipment specifications of an RRU3256

Type Input Power Dimension (H x W x D) Weight (kg)

RRU3256 -48 V DC; voltage range: 485 mm x 300 mm x 170 mm 21 (with the
-60 V DC to -32 V DC (24.7 L, with the housing) housing)
480 mm x 270 mm x 140 mm 19.5 (without the
(18 L, with the housing) housing)

The following table lists the environmental specifications of an RRU3256.

Table 6 Environmental specifications of an RRU3256

Type Operating Relative Absolute Atmospheric Storage Time


Temperature Humidity Humidity Pressure

RRU3256 With solar 5% RH to 100% 1 g/m3 to 30 70 kPa to 106 It is


radiation of 1120 RH g/m3 kPa recommended
2
W/m : -40C to that the device
+45C be installed
Without solar and used
radiation: -40C to within one
+50C year after its
delivery
because of the
failure rate.

The following table lists the compliance standards for an RRU3256.

Table 7 Compliance standards for an RRU3256

Type Operating Environment Anti-seismic Performance Protection Rating

RRU3256 3GPP TS 36.141 NEBS GR63 zone4 IP65


ETSI EN 300019-1-4
V2.1.2 (2003-04) Class
4.1: "Non-
weatherprotected
locations"

Table 8 lists the surge protection specifications of ports on an RRU3256.

NOTE:
Unless otherwise specified, the surge protection specifications depend on the surge waveform of 8/20 s.
All the surge current items, unless otherwise specified as Maximum discharge current, refer to Nominal
discharge current.

Table 8 Surge protection specifications of ports on an RRU3256

Port Usage Surge Protection Mode Specification


Scenario

Power supply Applicable to Surge Differential 2 kV (1.2/50 s)


port all scenarios mode

Common mode 4 kV (1.2/50 s)

Surge current Differential 10 kA


mode

Common mode 20 kA

RF port Applicable to Surge current Differential 8 kA


all scenarios mode

Common mode 40 kA

RET port Applicable to Surge current Differential 3 kA


all scenarios mode

Common mode 5 kA

Alarm port Applicable to Surge current Differential 250 A


all scenarios mode

Common mode 250 A

Specifications of CPRI Ports


The following table lists the specifications of CPRI ports on an RRU3256.
Table 9 Specifications of CPRI ports on an RRU3256

Type Number of CPRI Data Topology Cascading Maximum


CPRI Ports Rate (Gbit/s) Levels Distance from
the BBU (km)

RRU3256 2 4.9 or 9.8 Star, chain, or 4 If only one


ring level of RRUs
is configured,
the maximum
distance
between an
RRU and a
BBU is 10 km.
If multiple
levels of RRUs
are configured,
the maximum
distance
between an
RRU in the
lowest level
and a BBU is
20 km.

Antenna Capability
The following table lists the antenna capability of an RRU3256.

Table 10 Antenna capability of an RRU3256

Type TMA Support Supported RET Antennas

RRU3256 Not supported AISG2.0 and AISG1.1

NOTE:
For RF moudles supporting RET antennas, the feeding voltage is 12 V and feeding current is 2.3 A.

Parent topic: Technical Specifications of RRUs