FOUNTATION Calculation Sheet
Automatic Irrigation System Calculation

Irrigation Water Demand Requirement

Plant Description Area / Quantity Watering Rate LPD


Shrubs 431.47 m2 16 liters/ day/m2 6903.52
Turf or Grass 1872 m2 12 liters/ day/m2 22464
Ground Cover 1160 m 2
12 liters/ day/m2 13920
Trees 115 No. 120 liters/ day/m2 13800
Palms 8 No. 150 liters/ day/m2 1200
Total Watering Rate 58287.52
Adding 2% as Factor Of Safety 59453.27

From Perivious Data Get


Storage tank for 1 day = 59.5 m3
Storage tank for 2 days = 119 m3
Fountain Design

The basic point in design of fountain from catalogue according to the shape of fountain
and water height and water through and degree of water

From Catalogue chose the type of Nozzle you want


Insert Following Data

Nozzel Model = MC-125


Nozzel Flow Rate = 72 L/min
Nozzel Tip Pressure = 9.8 m
Maximum Flow Height = 1 m
Size of Inlet Pipe = 1.25 Inch
Quantity = 1 Unit

No. Of pump will used = 1 Pump


No. Of standby pumps = 1 Pump

Get pump flow rate = 4.32 m3/hr

Assuming flow from drain outlet to vacum point = 50 %

Suction pipe maximum velocity will be 1.2 m/s from skimmer & drain outlet
Pump flow rate = 2.16 m3/hr
No. Of outlet = 2 Outlet
Each outlet give flow rate = 1.08 m3/hr

Dia 1 = 17.66692 Taking it = 50 mm.


Dia 2 = 24.9848 Taking it = 50 mm.
Dia 3 = 30.6 Taking it = 50 mm.
Dia 4 = 35.33384 Taking it = 50 mm.

NOTE :-
No. of pipe will be taken according to No. of outlet for 2 outlet in series take to Dia 2

Vacum pipe maximum velocity will be 1.2 m/s from skimmer & drain outlet
Pump flow rate = 2.16 m3/hr
No. Of Vacum Point = 1 Outlet
Each outlet give flow rate = 2.16 m3/hr

Dia 1 = 24.9848 Taking it = 40 mm.


Dia 2 = 35.33384 Taking it = 40 mm.
Dia 3 = 43.27494 Taking it = 40 mm.
Dia 4 = 49.96959 Taking it = 50 mm.

NOTE :-
No. of pipe will be taken according to No. of outlet for 2 outlet in series take to Dia 2
Supply pipe maximum velocity will be 2 m/s

Dia 1 = 27.6 Taking it = 40 mm.


Dia 2 = 39.1 Taking it = 40 mm.
Dia 3 = 47.9 Taking it = 50 mm.
Dia 4 = 55.3 Taking it = 50 mm.

NOTE :-
No. of pipe will be taken according to No. of outlet for 2 outlet in series take to Dia 2

Getting the filter area to be used


Pump flow rate = 4.32 m3/hr
Filter area = 0.1 m2 at 15 Gpm / ft2
Assume we have to use a filter with diameter = 60 cm
No. of filter required = 1 Filter

Fountain Lighting :
For lighting we need about 5.4 watt to 16.30 watt for each 1m1
Surface Area of Fountain Pool = 4 m2
Take the watt required for each 1m2 = 15 Watt
Total watt required = 60 Watt
for lamp have capacity of = 50 Watt
No. of lamp required = 2 Lamp

Pump head calculation for swimming pools


Filter pressure drop = 2 f
Chlorination auto pilot unit = 2 f
Maximum distance from farest way to pump = 3 f
Static head heat pump = 1 f

Pump head = 44.7 f


Pump HP = 6 HP

Filteration Pump 108 GPM & 19 PSI & 6 HP


No. of Pumps 1 Duty & 1 Standby
No. Of Filter 1 Filter with Diameter 60 cm

NOTE :-
you can use Submersible or filteration pump