Sei sulla pagina 1di 26

W 260 Photoelectric switches

Photoelectric
proximity switches, W 260: Standard photoelectric
BGS
Photoelectric
proximity switches,
switch series for a broad range
energetic

Photoelectric of applications
reflex switches

universal voltage 12 . . . 24 V DC
and 24 . . . 240 V AC with poten-
tial-free relay contact (SPDT) or,
alternatively, adjustable time
delay.

A variety of features make these


sensors particularly operator-
friendly. These include visible red
transmitted light used as an align-
ment aid, or the simple and
flexible connection system,
glass/stainless steel fibre-optic
cables for harsh operating condi-

T
tions in confined environments.
All of these benefits open up
The W 260 series with its applications far beyond hand-
impressive scanning ranges and ling/warehousing systems, the
Through-beam
photoelectric features has been specially packaging industry and wood
switches designed for a wide variety of working. All device variants
Photoelectric different applications. The have been granted UL and CSA
switches with
fibre-optic cable sensors, through-beam photo- approval.
Proximity mode electric switches, energetic
Photoelectric photoelectric proximity switches, One last highlight: the W 260
switches with
fibre-optic cable and photoelectric reflex switches complies with EN 50081-1
Through-beam mode with background suppression are (interference radiation). This
contained in robust plastic makes it the perfect sensor
housings. Handling is simple and solution for door and gate control
user-friendly. Two supply voltages systems in underground garages
are available: and for use in residential blocks
low voltage 10 . . . 30 V DC with or hotels.
PNP or NPN transistor switching
output and test input and

246 SENSICK CATALOGUE


W 260

n WS/WE 260

through-beam photo-
electric switches and
WT 260 photo-
electric proximity
switches used for
monitoring contours
in palletisation
systems to ensure
that no problems are
encountered during
packaging.

b A WT 260 photoelectric proximity switch

controlling a commissioning system used


in the wood-working industry.

v CE conformity to EN 50081-1 and,

therefore, the right choice for residential


and commercial applications: the WL 260
photoelectric reflex switch used to monitor
the closing edges in automatic door and
gate systems.

v WS/WE 260 through-beam photoelectric

switches used for detecting the outline of


vehicle bodies on assembly lines in the
automotive industry.

SENSICK CATALOGUE 247


WT 260 Photoelectric proximity switches, background suppression, infrared light -- DC

Dimensional drawing
Scanning distance
0 . . . 380 mm
25 63

1.5
Photoelectric proximity switches 5

Reliable detection of dark objects


even against light backgrounds
Scanning distance continuously 1 2

77.5
14
adjustable 3
4
Terminal chamber or M 12 plug,

39.5

19.5
4-pin or 5-pin
6
Test input
4

5.5
max.
21
Pre-failure signalling output
19.5
50
5.5 61

Adjustments possible 1 Standard direction of material being scanned


WT 260-P 260 2 Centre of optical axis, receiver
WT 260-P 460 3 Centre of optical axis, sender
WT 260-P 560 4 Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm optionally at
5 bottom or rear; or M 12 equipment plug bottom
SENS
5 LED signal strength indicator, red
L 6 Through hole l 5.2 mm on both sides for M 5 hex nut
7 D 8
MODE 7 Scanning distance adjustment
5 8 Light-/dark-switching
1
(L = light-switching, D = dark-switching)
4 9
2 9 Terminals
3

Connection types
WT 260-P 260 WT 260-P 460 WT 260-P 560

C   V

Accessories page Terminals 4-pin, M 12 5-pin, M 12


Cable receptacles M 12 496
Mounting brackets* 510 1 1
1 L+ 1 L+ 1 L+
3 3
* included with delivery 2 M 2 M 2 M
4 4
4 Q 4 Q 4 Q
5
3 VMA 3 3 VMA
2 2
5 TE 5 TE 5 TE

248 SENSICK CATALOGUE


WT 260

Technical data WT 260- P 260 P 460 P 560

Scanning distance Max.: 0 . . . 380 mm, adjustable 1)


Min.: 75 . . .160 mm, adjustable 1)
Scanning distance Adjustable, potentiometer 270

Light source 2), light type LED, infrared light


Light spot diameter Approx. 17 mm at 300 mm
Aperture angle sender Approx. 1.5

Supply voltage Vs 10 . . . 30 V DC 3)
Ripple 4) 5 VSS
Current consumption 5) 35 mA

Switching outputs PNP, open collector: Q


Output current IA max. 100 mA
Light receiver, switching mode Light-/dark-switching by sliding switch
Response time 6) 2 ms
Max. switching frequency 7) 250/s
Pre-failure signalling output VMA 8) 100 mA, static

Test input TE sender off PNP: TE to + VS

Connection types Terminal chamber


Plug M 12, 4-pin
Plug M 12, 5-pin
VDE protection class 9) V
Circuit protection 10) A, B, C, D
Enclosure rating IP 66

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Object with 90 % remission 5) Without load 10) A = Vs connections reverse-polarity 11) Black = 16 % remission
(based on standard white DIN 5033) 6) With resistive load protected Grey = 18 % remission
2) Average service life 100,000 h 7) With light/dark ratio 1:1 B = Inputs/outputs reverse-polarity White = 90 % remission
at TA = + 25 C 8) Operating reserve < 50 % protected
3) Limit values 9) Reference voltage 50 V DC C = Interference suppression
4) Must be within VS tolerances D = Outputs overcurrent and short-
circuit protected

Scanning distance Order information


Type Part no.
20
1 A 95 140 WT 260-P 260 6 009 471
6%/90% WT 260-P 460 1 011 540
1 B 50 300
1 WT 260-P 560 1 011 541
2 A 85 150
15
2 B 25 340

3 A 75 160
18%/90%
3 B 0 380 10
2
0 (mm) 100 200 300 400
% of scanning distance

1 Scanning range on black 11)/background white


2 Scanning range on grey 11)/background white 5
90%/90%
3 Scanning range on white 11)/background white
A Scanning distance control set to MIN 3
B Scanning distance control set to MAX
0
(mm) 150 200 250 300 350 400

SENSICK CATALOGUE 249


WT 260 Photoelectric proximity switches, background suppression, infrared light -- UC

Dimensional drawing
Scanning distance
0 . . . 380 mm
25 63

1.5
Photoelectric proximity switches 5

Reliable detection of dark objects


even against light backgrounds
Scanning distance continuously 1 2

77.5
14
adjustable 3
4
Terminal chamber

39.5

19.5
Universal current supply,
6
relay output, SPST, timer optional

5.5
4

5.5
19.5
50 5.5
5.5 61

Adjustments possible 1 Standard direction of material being scanned


WT 260-S 260 WT 260-R 260 2 Centre of optical axis, receiver
3 Centre of optical axis, sender
4 Cable entry gland 1/2HH PF thread for cable
5 diameters from 6 to 10 mm optionally at
bottom or rear
OUTPUT TIMER
SENS.

7 1 1 5 LED signal strength indicator, red


SENS.

7
L.ON D.ON 0.1 5(SEC)

6 Through hole l 5.2 mm on both sides for


MODE

1 2 3 4
L. ON D. ON

8 1 2 M 5 hex nut
MODE

MODE

8
7 Scanning distance adjustment
TIMER

4 NORMAL
3 ON.D.
2 OFF.D.
1 O.S.D.

9
8 Light/dark rotary switch
3 1 3 1 (L.ON = light-switching, D.ON = dark-switching)
1 0 9 Time range control
4 2 4 2
1 0 Terminals
1 1 Red LED status indicator; switching output
active
1 2 Time delay selector switch
O.S.D. = One Shot
OFF.D. = OFF delay
ON.D. = ON delay
Normal = No delay

C   V Connection type Time delay


WT 260-S 260 t = 0.1 5 s
WT 260-R 260
Light
beam Uninterrupted
Timer mode Interrupted
NORMAL ON
OFF
ON
1 23 4 OFF
O.S.D. ON
T T T OFF
ON
1 23 4 T T T OFF
OFF.D. ON
Accessories page Terminals T T T OFF
Mounting brackets* 510 ON
1 23 4 T OFF
* included with delivery ON.D. ON
1 L1 T
OFF
2 N T T T
ON
1 23 4 OFF
3
Setting mode: X light-switching
4 x dark-switching

250 SENSICK CATALOGUE


WT 260

Technical data WT 260- S 260 R 260

Scanning distance Max.: 0 . . . 380 mm, adjustable 1)


Min.: 75 . . .160 mm, adjustable 1)
Scanning distance Adjustable, potentiometer 270

Light source 2), light type LED, infrared light


Light spot diameter Approx. 17 mm at 300 mm
Angle of dispersion, sender Approx. 1.5

Supply voltage Vs3) 12 . . . 240 V DC


24 . . . 240 V AC
Power consumption 5 VA

Switching outputs Relay, SPST, electrically isolated


Switching current IA max. 4) 3 A/240 V AC; 3 A/30 V DC
Light receiver, switching mode Light-/dark-switching by rotary switch
Response time 20 ms
Max. switching frequency 5) 25/s
Time delay With LED display: switching output active
Switch position: 1 O.S.D. One shot
2 OFF.D. OFF delay
3 ON.D. ON delay
4 Normal No delay
Delay Adjustable, 0.1. . . 5 s; potentiom. 270

Connection type Terminal chamber

VDE protection class 6) V


Circuit protection 7) A, C
Enclosure rating IP 66

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Object with 90 % remission (based on 3) 10 % 6) Reference voltage 250 V UC 8) Black = 16 % remission
standard white DIN 5033) 4) Provide suitable spark suppression for 7) A = Vs connections reverse-polarity Grey = 18 % remission
2) Average service life 100,000 h inductive or capacitive loads protected White = 90 % remission
at TA = + 25 C 5) With light/dark ratio 1:1 C = Interference suppression

Scanning distance Order information


Type Part no.
20
1 A 95 140 WT 260-S 260 6 009 473
6%/90% WT 260-R 260 6 009 472
1 B 50 300
1
2 A 85 150
15
2 B 25 340

3 A 75 160
18%/90%
3 B 0 380 10
2
0 (mm) 100 200 300 400
% of scanning distance

1 Scanning range on black 8)/background white


2 Scanning range on grey 8)/background white 5
90%/90%
3 Scanning range on white 8)/background white
3
A Scanning distance control set to MIN
B Scanning distance control set to MAX
0
(mm) 150 200 250 300 350 400

SENSICK CATALOGUE 251


WT 260 Photoelectric proximity switches, energetic, infrared light -- DC

Dimensional drawing
Scanning distance
10 . . . 3200 mm
25 63

1,5
Photoelectric proximity switches 4

Adjustable sensitivity
Terminal chamber or M 12,
4-pin plug 1

16.7

78
Test input 2
3

33.1

20
5

6
max.
3

15
19.5
50 5.5
5.5 61

Adjustments possible 1 Centre of optical axis, receiver


WT 260-F 280 2 Centre of optical axis, sender
WT 260-F 480 3 Cable entry gland 1/2HH PF thread for cable
WT 260-E 280 diameters from 6 to 10 mm optionally at bottom or
rear; or M 12 equipment plug, bottom
4 4 LED signal strength indicator, yellow,
switching output active
5 Through hole 5.2 mm on both sides for
7
6 D.ON L.ON M 5 hex nut
SENS.
6 Sensitivity adjustment
7 Light/dark rotary switch
3
1 L.ON = light-switching, D.ON = dark-switching
8
4 8 Terminals
2

Connection types
WT 260-F 280 WT 260-F 480

C   V WT 260-E 280

Accessories page Terminals 4-pin, M 12


Cable receptacles 496
Mounting brackets* 510 1
1 L+ 1 L+
3
* included with delivery 2 M 2 M
4
4 Q 4 Q
2
3 TE 3 TE

252 SENSICK CATALOGUE


WT 260

Technical data WT 260- F 280 F 480 E 280

Scanning distance 0 . . . 3200 mm, adjustable 1)


Operating distance 15 . . . 2500 mm, adjustable 1)
Sensitivity Adjustable, potentimeter 270

Light source 2), light type LED, infrared light


Light spot diameter Approx. 80 mm at 2500 mm
Angle of dispersion, sender Approx. 1.8

Supply voltage Vs 10 . . . 30 V DC 3)
Ripple 4) 5 VSS
Current consumption 5) 35 mA

Switching outputs PNP, open collector: Q


NPN, open collector: Q
Output current IA max. 100 mA
Light receiver, switching mode Light-/dark-switching by rotary switch
Response time 6) 5.0 ms
Max. switching frequency 7) 100/s

Test input TE sender off PNP: TE to + VS


NPN: TE to 0 V

Connection types Terminal chamber


Plug M 12, 4-pin

VDE protection class 8) V


Circuit protection 9) A, B, C, D
Enclosure rating IP 67

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Object with 90 % remission (based on 4) Must be within VS tolerances 9) A = Vs connections reverse-polarity
standard white DIN 5033) 5) Without load protected
2) Average service life 100,000 h 6) With resistive load B = Inputs/outputs reverse-polarity
at TA = + 25 C 7) With light/dark ratio 1:1 protected
3) Limit values 8) Reference voltage 50 V DC C = Interference suppression
D = Outputs overcurrent and short-circuit
protected

Scanning distance Order information


Type Part no.
100
1 10 40 800 1200 WT 260-F 280 6 020 982
WT 260-F 480 6 020 983
2 10 15 1500 2000
WT 260-E 280 6 020 984
3 10 15 2500 3200
90%
0 (mm)2000 3000 3

Operating distance Scanning distance,


max. typical 10

1 Scanning range on black , 6 % remission


2 Scanning range on grey, 18 % remission 18%
3 Scanning range on white, 90 % remission 2
Operating reserve

1 Operating
6% distance

1
Scanning distance, max. typical
(mm) 500 1000 1500 2000 2500 3000 3500

SENSICK CATALOGUE 253


WT 260 Photoelectric proximity switches, energetic, infrared light -- UC

Dimensional drawing
Scanning distance
10 . . . 3500 mm
25 63

1,5
Photoelectric proximity switches 4

Adjustable sensitivity
Terminal chamber
Universal current supply, 1

16.7

78
relay output, SPDT, timer optional, 2
tON and tOFF can be connected 3

33.1
separately

20
5
Enclosure rating IP 67

6
3
CE noise radiation EN 50081-1

5.5
19.5
(Residential standard) 50 5.5
5.5 61

Adjustments possible 1 Centre of optical axis, receiver


WT 260-S 280 WT 260-R 280 2 Centre of optical axis, sender
3 Cable entry gland 1/2HH PF thread
4 for cable diameters from 6 to 10 mm
optionally at bottom or rear
7
6 ON. DLY 4 LED signal strength indicator, red
SENS. SENS.
8 5 Through hole l 5.2 mm on both sides
OFF. DLY
for M 5 hex nut
3 3
1 6 Sensitivity adjustment
9 1
4 4 7 Time control ON-delay tON
2
2 8 Time control OFF-delay tOFF
5 5
9 Terminals

Connection type Time delay


WT 260-S 280 t = 0.1 10 s
C   V WT 260-R 280
VS ON
OFF
Light received yes
no
Relay active yes
no

tON tOFF

4 4 4
3 3 3
5 5 5
Accessories page Terminals
Mounting brackets* 510
* included with delivery 1 L1
2 N
4
3
5

254 SENSICK CATALOGUE


WT 260

Technical data WT 260- S 280 R 280

Scanning distance, max. typical 10 . . . 3500 mm, adjustable 1)


Operating distance 20 . . . 3000 mm, adjustable 1)
Sensitivity Adjustable, potentiometer 270

Light source 2), light type LED, infrared light


Light spot diameter Approx. 95 mm at 3000 mm
Angle of dispersion, sender Approx. 1.7

Supply voltage VS 3) 12 . . . 240 V DC


24 . . . 240 V AC
Power consumption 5 VA

Switching output Relay, SPDT, electrically isolated


Switching current I max 4) 3 A/240 V AC; 3 A/30 V DC
Light receiver, switching mode Light-switching
Response time 20 ms
Max. switching frequency 5) 25/s

Time delays
ON delay tON 0.1. . .10 s, can be connected separately
OFF delay tOFF 0.1. . .10 s, can be connected separately

Connection type Terminal chamber


CE noise radiation Level EN 50081-1
(Residential standard)
VDE protection class 6) V
Circuit protection 7) A, C
Enclosure rating IP 67

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Object with 90 % remission (based on 3) 10 % 6) Reference voltage 250 V UC
standard white DIN 5033) 4) Provide suitable spark suppression for 7) A = Vs connections reverse-polarity
2) Average service life 100,000 h inductive or capacitive loads protected
at TA = + 25 C 5) With light/dark ratio 1:1 C = Interference suppression

Scanning distance Order information


Type Part no.
100
1 30 40 800 1100 WT 260-S 280 6 020 771
WT 260-R 280 6 020 772
2 10 20 1500 2000

3 10 20 3000 3500

0 (mm) 1000 2000 3000 4000

Operating distance Scanning distance,


max. typical 10

1 Scanning range on black , 6 % remission 90%


2 Scanning range on grey, 18 % remission 3
3 Scanning range on white, 90 % remission
Operating reserve

Operating
18%
distance
2
1
1
6% Scanning distance, max. typical
(mm) 1000 2000 3000

SENSICK CATALOGUE 255


WT 260 Photoelectric proximity switches, energetic, red light -- DC

Dimensional drawing
Scanning distance
5 . . . 1500 mm
25 63

1.5
Photoelectric proximity switches 4

Adjustable sensitivity
Terminal chamber or
M 12, 4-pin plug 1

16.7

78
Test input 2
3

33.1

20
5

6
max.
3

15
19.5
50 5.5
5.5 61

Adjustments possible 1 Centre of optical axis, receiver


WT 260-F 270 2 Centre of optical axis, sender
WT 260-F 470 3 Cable entry gland 1/2HH PF thread for cable
WT 260-E 270 diameters from 6 to 10 mm optionally at bottom or
rear; or M 12 equipment plug, bottom
4 4 LED signal strength indicator, yellow,
switching output active
5 Through hole 5.2 mm on both sides for
7
6 D.ON L.ON M 5 hex nut
SENS.
6 Sensitivity adjustment
7 Light/dark rotary switch
3
1 L.ON = light-switching, D.ON = dark-switching
8
4 8 Terminals
2

Connection types
WT 260-F 270 WT 260-F 470

C   V WT 260-E 270

Accessories page Terminals 4-pin, M 12


Cable receptacles 496
Mounting brackets* 510 1
1 L+ 1 L+
* included with delivery 3
2 M 2 M
4
4 Q 4 Q
2
3 TE 3 TE

256 SENSICK CATALOGUE


WT 260

Technical data WT 260- F 270 F 470 E 270

Scanning distance 5 . . .1500 mm, adjustable 1)


Operating distance 5 . . .1000 mm, adjustable 1)
Sensitivity Adjustable, potentimeter 270

Light source 2), light type LED, infrared light


Light spot diameter Approx. 45 mm at 1000 mm
Angle of dispersion, sender Approx. 2.5

Supply voltage Vs 10 . . . 30 V DC 3)
Ripple 4) 5 VSS
Current consumption 5) 35 mA

Switching outputs PNP, open collector: Q


NPN, open collector: Q
Output current IA max. 100 mA
Light receiver, switching mode Light-/dark-switching by rotary switch
Response time 6) 1.5 ms
Max. switching frequency 7) 333/s

Test input TE sender off PNP: TE to + VS


NPN: TE to 0 V

Connection types Terminal chamber


Plug M 12, 4-pin

VDE protection class 8) V


Circuit protection 9) A, B, C, D
Enclosure rating IP 67

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Object with 90 % remission (based on 4) Must be within VS tolerances 9) A = Vs connections reverse-polarity C = Interference suppression
standard white DIN 5033) 5) Without load protected D = Outputs overcurrent and short-circuit
2) Average service life 100,000 h 6) With resistive load B = Inputs/outputs reverse-polarity protected
at TA = + 25 C 7) With light/dark ratio 1:1 protected
3) Limit values 8) Reference voltage 50 V DC

Scanning distance Order information


Type Part no.
100
1 10 20 350 500 WT 260-F 270 6 020 979
WT 260-F 470 6 020 980
2 5 10 650 900
WT 260-E 270 6 020 981
3 5 1000 1500
90%
0 (mm) 300 600 900 1200 1500 3
Operating distance Scanning distance,
max. typical 10

1 Scanning range on black , 6 % remission


Operating
2 Scanning range on grey, 18 % remission distance
3 Scanning range on white, 90 % remission
Operating reserve

6% 18%
1 2

1
Scanning distance, max. typical
(mm) 500 1000 1500

SENSICK CATALOGUE 257


WT 260 Photoelectric proximity switches, energetic, red light -- UC

Dimensional drawing
Scanning distance
5 . . . 1700 mm
25 63

1.5
Photoelectric proximity switches 4

Adjustable sensitivity
Terminal chamber
Universal current supply, 1

16.7

78
Relay output, SPDT, timer optional, 2
tON and tOFF can be connected 3

33.1
separately

20
5
Enclosure rating IP 67

6
3
CE noise radiation EN 50081-1

5.5
19.5
(Residential standard) 50 5.5
5.5 61

Adjustments possible 1 Centre of optical axis, receiver


WT 260-S 270 WT 260-R 270 2 Centre of optical axis, sender
3 Cable entry gland 1/2HH PF thread
4 for cable diameters from 6 to 10 mm
optionally at bottom or rear
7
6 ON. DLY 4 LED signal strength indicator, red
SENS. SENS.
8 5 Through hole l 5.2 mm on both sides
OFF. DLY
for M 5 hex nut
3 3
1 6 Sensitivity adjustment
9 1
4 4 7 Time control ON-delay tON
2
2 8 Time control OFF-delay tOFF
5 5
9 Terminals

Connection type Time delay


WT 260-S 270 t = 0.1 10 s
C   V WT 260-R 270
VS ON
OFF
Light received yes
no
Relay active yes
no

tON tOFF

4 4 4
3 3 3
5 5 5
Accessories page Terminals
Mounting brackets* 510
* included with delivery 1 L1
2 N
4
3
5

258 SENSICK CATALOGUE


WT 260

Technical data WT 260- S 270 R 270

Scanning distance, max. typical 5 . . .1700 mm, adjustable 1)


Operating distance 5 . . .1300 mm, adjustable 1)
Sensitivity Adjustable, potentiometer 270

Light source 2), light type LED, infrared light


Light spot diameter Approx. 60 mm at 1300 mm
Angle of dispersion, sender Approx. 1.8

Supply voltage VS 3) 12 . . . 240 V DC


24 . . . 240 V AC
Power consumption 5 VA

Switching output Relay, SPDT, electrically isolated


Switching current I max 4) 3 A/240 V AC; 3 A/30 V DC
Light receiver, switching mode Light-switching
Response time 20 ms
Max. switching frequency 5) 25/s

Time delays
ON-delay tON 0.1. . .10 s, can be connected separately
OFF-delay tOFF 0.1. . .10 s, can be connected separately

Connection type Terminal chamber


CE noise radiation Level EN 50081-1
(Residential standard)
VDE protection class 6) V
Circuit protection 7) A, C
Enclosure rating IP 67

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Object with 90 % remission (based on 3) 10 % 6) Reference voltage 250 V UC
standard white DIN 5033) 4) Provide suitable spark suppression for 7) A = Vs connections reverse-polarity
2) Average service life 100,000 h inductive or capacitive loads protected
at TA = + 25 C 5) With light/dark ratio 1:1 C = Interference suppression

Scanning distance Order information


Type Part no.
100
1 10 20 400 450 WT 260-S 270 6 020 769
WT 260-R 270 6 020 770
2 5 800 900

3 5 1300 1700

0 (mm) 500 1000 1500 2000

Operating distance Scanning distance,


max. typical 10
90%
1 Scanning range on black , 6 % remission
3
2 Scanning range on grey, 18 % remission
3 Scanning range on white, 90 % remission
Operating reserve

Operating
2 distance
1 18%
1
6% Scanning distance, max. typical
(mm) 500 1000 1500

SENSICK CATALOGUE 259


WL 260 Photoelectric reflex switches, red light -- DC

Dimensional drawing
Scanning range
0.01 . . . 14 m
25 63

1.5
Photoelectric reflex switches 4

Polarising filter providing reliable


detection even of objects with
reflective surfaces 1

16.7

78
Adjustable sensitivity 2
Terminal chamber or M 12, 3

33.1
4-pin plug

20
5
Test input

6
max.
3

15
19.5
50 5.5
5.5 61

Adjustments possible 1 Centre of optical axis, receiver


WL 260-F 270 2 Centre of optical axis, sender
WL 260-F 470 3 Cable entry gland 1/2HH PF thread for cable
WL 260-E 270 diameters from 6 to 10 mm optionally at bottom or
rear; or M 12 equipment plug, bottom
4 4 LED signal strength indicator, yellow,
switching output active
5 Through hole 5.2 mm on both sides for
7
6 D.ON L.ON M 5 hex nut
SENS.
6 Sensitivity adjustment
7 Light/dark rotary switch
3
1 L.ON = light-switching, D.ON = dark-switching
8
4 8 Terminals
2

Connection types
WL 260-F 270 WL 260-F 470

C   V WL 260-E 270

Accessories page Terminals 4-pin, M 12


Cable receptacles 496
Mounting brackets* 510 1
1 L+ 1 L+
Reflector P 250* 520 3
2 M 2 M
* included with delivery 4
4 Q 4 Q
2
3 TE 3 TE

260 SENSICK CATALOGUE


WL 260

Technical data WL 260- F 270 F 470 E 270

Scanning range, max. typical/ on refl. 0.01. . .14 m / PL 80 A


max. typical/ on refl. 0.01. . . 9.5 m / P 250 (included)
Operating range 0.01. . . 8 m / P 250
Sensitivity Adjustable, potentiometer 270
Light source 1), light type LED, visible red light
with polarising filter
Light spot diameter Approx. 240 mm at 8 m
Angle of dispersion, sender Approx. 1.7
Supply voltage Vs 10 . . . 30 V DC 2)
Ripple 3) 5 VSS
Current consumption 4) 35 mA
Switching outputs PNP, open collector: Q
NPN, open collector: Q
Output current IA max. 100 mA
Light receiver, switching mode Light /dark-switching by rotary switch
Response time 5) 1.5 ms
Max. switching frequency 6) 333/s

Test input TE sender off PNP: TE to + VS


NPN: TE to 0 V

Connection types Terminal chamber


M 12 plug, 4-pin

VDE protection class 7) V


Circuit protection 8) A, B, C, D
Enclosure rating IP 67

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PMMA
1) Average service life 100,000 h 5) With resistive load 8) A = Vs connections reverse-polarity C = Interference suppression
at TA = +25 C 6) With light/dark ratio 1:1 protected D = Outputs overcurrent and short-
2) Limit values 7) Reference voltage 50 V DC B = Inputs/outputs reverse-polarity circuit protected
3) Must be within VS tolerances protected
4) Without load

Scanning range and operating reserve Order information


Type Part no.
100
1 0.01 11.5 14 WL 260-F 270 6 020 976
WL 260-F 470 6 020 977
2 0.01 8 9.5
WL 260-E 270 6 020 978
3 0.01 9 11

4 0.01 7 8.5 1
5 0.01 5.5 7
10
6 0.02 4 5.5

0 (m) 4 6 8 10 14 6 2 Operating
Operating range Scanning range, range
Operating reserve

max. typical
5
Reflector type Operating range
1 PL 80 A 0.01. . .11.5 m 1
2 P 250 0.01. . . 8.0 m Scanning range, max. typical
3 PL 50 A or 0.01. . . 9.0 m (m) 2 4 6 8 10 12 14
PL 40 A
4 PL 30 A or 0.01. . . 7.0 m
PL 31 A
5 PL 20 A 0.01. . . 5.5 m
6 Reflective tape 0.02 . . . 4.0 m
Diamond Grade
SENSICK CATALOGUE 261
WL 260 Photoelectric reflex switches, red light -- UC

Dimensional drawing
Scanning range
0.01 . . . 15 m
25 63

1,5
Photoelectric reflex switches 4

Polarising filter providing reliable


detection even of objects with
reflective surfaces 1

16.7

78
Terminal chamber
2
Universal current supply, 3

33.1
relay output, SPDT, timer optional,

20
tON and tOFF can be connected 5

6
separately 3

5.5
19.5
Enclosure rating IP 67 50 5.5
CE noise radiation EN 50081-1 5.5 61

(Residential standard)
Adjustments possible 1 Centre of optical axis, receiver
WL 260-S 270 WL 260-R 270 2 Centre of optical axis, sender
3 Cable entry gland 1/2HH PF thread
4 for cable diameters from 6 to 10 mm
optionally at bottom or rear
7
6 ON. DLY 4 LED signal strength indicator, red
SENS. SENS.
8 5 Through hole l 5.2 mm on both sides
OFF. DLY
for M 5 hex nut
3 3
1 6 Sensitivity adjustment
9 1
4 4 7 Time control ON-delay tON
2
2 8 Time control OFF-delay tOFF
5 5 9 Terminals

Connection type Time delay


WL 260-S 270 t = 0.1 10 s
WL 260-R 270

C   V VS ON
OFF
Light received yes
no
Relay active yes
no

tON tOFF

4 4 4
3 3 3
5 5 5
Accessories page Terminals
Mounting brackets* 510
Reflector P 250* 520 1 L1
* included with delivery 2 N
4
3
5

262 SENSICK CATALOGUE


WL 260

Technical data WL 260- S 270 R 270

Scanning range, max. typical/ on refl. 0.01. . .15 m / PL 80 A


max. typical/ on refl. 0.01. . .11 m/ P 250 (included)
Operating range 0.01. . .10 m/ P 250
Sensitivity Adjustable, potentiometer 270

Light source 1), light type LED, visible red light


with polarising filter
Light spot diameter Approx. 300 mm at 10 m
Angle of dispersion, sender Approx. 1.7

Supply voltage Vs2) 12 . . . 240 V DC


24 . . . 240 V AC
Power consumption 5 VA

Switching output Relay, SPDT, electrically isolated


Switching current IA max. 3) 3 A/240 V AC; 3 A/30 V DC
Light receiver, switching mode Light-switching
Response time 20 ms
Max. switching frequency 4) 25/s
Time delays
ON delay tON 0.1. . .10 s, can be connected separately
OFF delay tOFF 0.1. . .10 s, can be connected separately

Connection type Terminal chamber


CE noise radiation Level EN 50081-1
(Residential standard)
VDE protection class 5) V
Circuit protection 6) A, C
Enclosure rating IP 67

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PMMA
1) Average service life 100,000 h 3) Provide suitable spark suppression for 5) Reference voltage 250 V UC
at TA = + 25 C inductive or capacitive loads 6) A = Vs connections reverse-polarity
2) 10 % 4) With light/dark ratio 1:1 protected
C = Interference suppression

Scanning range and operating reserve Order information


Type Part no.
100
1 0.01 13 15 WL 260-S 270 6 020 767
WL 260-R 270 6 020 768
2 0.01 10 11

3 0.01 11.5 12.5

4 0.01 8.5 9.7


4
5 0.01 6.5 7.8

6 0.02 5.3 6.5 10

0 (m) 2 4 6 8 10 12 14 16 1
Operating range Scanning range,
Operating reserve

max. typical 6
Operating
Reflector type Operating range range 2
1 PL 80 A 0.01. . .13.0 m
1
2 P 250 0.01. . .10.0 m Scanning range, max. typical
3 PL 50 A or 0.01. . .11.5 m (m) 5 10 15
PL 40 A
4 PL 30 A or 0.01. . . 8.5 m
PL 31 A
5 PL 20 A 0.01. . . 6.5 m
6 Reflective tape 0.01. . . 5.3 m
Diamond Grade SENSICK CATALOGUE 263
WS/WE 260 Through-beam photoelectric switches, infrared light -- DC

Dimensional drawing
Scanning range
30 m
25 63

1.5
Through-beam photoelectric switches 3

Adjustable sensitivity
Terminal chamber or M 12,
4-pin plug 1

77.5
Test input

51.5
2

19.5
4

max.
2

15
5.5
19.5
50 5.5
5.5 61

Adjustments possible 1 Centre of optical axis, sender/receiver


WS/WE 260-F 230 2 Cable entry gland 1/2HH PF thread
WS/WE 260-F 430 for cable diameters from 6 to 10 mm
WS/WE 260-E 230 optionally at bottom or rear;
or M 12 equipment plug, bottom
3 LED signal strength indicator, red
3 4 Through hole l 5.2 mm on both sides
for M 5 hex nut
SENS.

5 Sensitivity adjustment
Min. Max.

5 6 Light/dark rotary switch


L.ON = light-switching, D.ON = dark-switching
L. ON D. ON

7 Terminals
6
MODE

3 1
7
4 2

Connection types
WS/WE 260-F 230 WS/WE 260-F 430
WS/WE 260-E 230

C   V

Terminals 4-pin, M 12
WS 260- G 230 WS 260- G 430
Accessories page Sender 1
1 L+ 1 L+
Cable receptacles M 12 496 3
M
2 M 2
Mounting brackets* 510 4
3 TE NC
2
Slotted masks 556 3 TE

* included with delivery

Receiver WE 260- E 230 WE 260- F 430


WE 260- F 230
1
1 L+ 1 L+
3
2 M 2 M
4
4 Q 4 Q
2
NC

264 SENSICK CATALOGUE


WS/WE 260

Technical data WS/WE 260- F 230 F 430 E 230

Scanning range, max. typical 30 m


Operating range 20 m
Sensitivity Adjustable, potentiometer 270

Light source 1), light type LED, infrared light


Light spot diameter Approx. 350 mm at 20 m
Angle of dispersion, sender Approx. 1
Angle of dispersion, receiver Approx. 20
Supply voltage VS 10 . . . 30 V DC 2)
Ripple 3) 5 VSS
Current consumption 4)
sender 20 mA
receiver 35 mA

Switching outputs PNP, open collector: Q


NPN, open collector: Q
Output current IA max. 100 mA
Light receiver, switching mode Light-/dark-switching by rotary switch
Response time 5) 1 ms
Max. switching frequency 6) 500/s

Test input TE sender off PNP, NPN: TE to 0 V

Connection types Terminal chamber


M 12 plug, 4 pin

VDE protection class 7) V


Circuit protection 8)
sender A, B
receiver A, B, C, D
Enclosure rating IP 66

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Average service life 100000 h 5) With resistive load 8) A = Vs connections reverse-polarity C = Interference suppression
at TA = + 25 C 6) With light/dark ratio 1:1 protected D = Outputs overcurrent and short-
2) Limit values 7) Reference voltage 50 V DC B = Inputs/outputs reverse-polarity circuit protected
3) Must be within VS tolerances protected
4) Without load

Scanning range and operating reserve Order information


Type Part no.
100
1 0 20 30 WS/WE 260-F 230 6 020 052
WS/WE 260-E 230 6 020 051
2 0 6 7
WS/WE 260-F 430 6 020 053
3 0 3 4

4 0 1.5 2
0(m) 4 8 12 16 20 24 28 30

Operating range Scanning range,


max. typical
10

Scanning range reduction when using slotted masks


1 Without slotted mask Operating range
Operating reserve

2 Slot width 5 mm
3 Slot width 2 mm
4 Slot width 1 mm Scanning range, max. typical
1

(m) 4 8 12 16 20 24 28

SENSICK CATALOGUE 265


WS/WE 260 Through-beam photoelectric switches, red light -- UC

Dimensional drawing
Scanning range
45 m
25 63

1.5
Through-beam photoelectric switches 3

Adjustable sensitivity
Terminal chamber
Universal current supply, 1

78
relay output, SPDT, timer optional,

49.8
tON and tOFF can be connected 2
separately

20
Enclosure rating IP 67 4

6
CE noise radiation EN 50081-1 2

5.5
19.5
(Residential standard) 50 5.5
5.5 61

Adjustments possible 1 Centre of optical axis, sender and receiver


WS/WE 260-S 270 WS/WE 260-R 270 2 Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm
3 optionally at bottom or rear
3 LED signal strength indicator, red
6
5 ON. DLY 4 Through hole l 5.2 mm on both sides
SENS. SENS.
7 for M 5 hex nut
OFF. DLY
5 Sensitivity adjustment
3 3
1 6 Time control ON-delay tON
8 1
4 4 7 Time control OFF-delay tOFF
2
2 8 Terminals
5 5

Connection type Time delay


WS/WE 260-S 270 t = 0.1 10 s
WS/WE 260-R 270
VS ON
OFF
Light received yes

C   V
no
Relay active yes
no

tON tOFF

4 4 4
3 3 3
5 5 5
Terminals
Accessories page Sender WS 260-S 270
Mounting brackets* 510
* included with delivery 1 L1
2 N

Receiver WE 260-S 270


WE 260-R 270

1 L1
2 N
4
3
5

266 SENSICK CATALOGUE


WS/WE 260

Technical data WS/WE 260- S 270 R 270

Scanning range, max. typical 45 m


Operating range 40 m
Sensitivity Adjustable, potentiometer 270

Light source 1), light type LED, visible red light


Light spot diameter Approx. 700 mm at 40 m
Angle of dispersion, sender Approx. 1
Angle of dispersion, receiver Approx. 20

Supply voltage VS2) 12 . . . 240 V DC


24 . . . 240 V AC
Power consumption
Sender 4 VA
Receiver 5 VA

Switching output Relay, SPDT, electrically isolated


Switching current IA max. 3) 3 A/240 V AC; 3 A/30 V DC
Light receiver, switching mode Light-switching
Response time 20 ms
Max. switching frequency 4) 25/s

Time delays
ON-delay tON 0.1. . .10 s, can be connected separately
OFF-delay tOFF 0.1. . .10 s, can be connected separately

Connection type Terminal chamber

CE noise radiation Level EN 50081-1


(Residential standard)
VDE protection class 5) V
Circuit protection 6) A, C
Enclosure rating IP 67

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS; optics: PC
1) Average service life 100,000 h 3) Provide suitable spark suppression for 5) Reference voltage 250 V UC
at TA = + 25 C inductive or capacitive loads 6) A = Vs connections reverse-polarity
2) 10 % 4) With light/dark ratio 1:1 protected
C = Interference suppression

Scanning range and operating reserve Order information


Type Part no.
100
WS/WE 260-S 270 6 020 773
WS/WE 260-R 270 6 020 774
0 40 45

0 (m) 10 20 30 40 50

Operating range Scanning range,


max. typical
10
Operating reserve

Operating range
Scanning range, max. typical
1

(m) 10 20 30 40 50

SENSICK CATALOGUE 267


WLL 260 Photoelectric switches for fibre-optic cable, red light -- DC

Dimensional drawing
Scanning range
max. 800 mm
25 63

1.5
Through-beam systems 4

Scanning distance
max. 65 (110) mm
Proximity systems
1

77.5
12
Wide range of fibre-optic cables 2
for through-beam and proximity 3

39.5
applications

19.5
Easy adaption of fibre-optic cable 5

using cap nut

5.5
3

max.
21
Adjustable sensitivity
19.5
Terminal chamber, at bottom or 50
5.5 61
rear or M 12 plug, 4-pin
Test input

Adjustments possible 1 Centre of optical axis, receiver


WLL 260-F 240 2 Centre of optical axis, sender
WLL 260-F 440 3 Cable entry gland 1/2HH PF thread for cable diameters
WLL 260-E 240 from 6 to 10 mm optionally at bottom or rear;
or M 12 equipment plug, bottom
4 LED signal strength indicator, red
5 Through hole l 5.2 mm on both sides for M 5 hex nut
4 6 Sensitivity adjustment
SENS.

7 Light/dark rotary switch


Min. Max.

6 L.ON = light-switching, D.ON = dark-switching


8 Terminals
L. ON D. ON

7
MODE

3 1
8
4 2

Connection types
WLL 260-E 240 WLL 260-F 440
WLL 260-F 240

C   V

Accessories page Terminals 4-pin, M 12


Cable receptacles 496
Mounting brackets* 510 1
1 L+ 1 L+
Fibre-optic cable 528 3
2 M 2 M
* included with delivery 4
4 Q 4 Q
2
3 TE 3 TE

268 SENSICK CATALOGUE


WLL 260

Technical data WLL 260- F 240 F 440 E 240

Suitable fibre-optic cables Fibre-optic cable series LIS/LBS


see page 552
Scanning distance/ranges Depends on the fibre-optic cable used
Through-beam system
Scanning distance, max. typical 1) 0 . . . 65 mm
0 . . .110 mm w. special fibre-optic cable
Scanning range 1) 0 . . . 50 mm
0 . . . 90 mm w. special fibre-optic cable
Proximity system
Scanning range, max. typical 0 . . . 800 mm
Operating range 0 . . . 700 mm
Sensitivity Adjustable, potentiometer 270

Light source 2), light type LED, visible red light


Light spot diameter Depends on scanning range
Aperture fibre-optic cable Approx. 65

Supply voltage VS 10 . . . 30 V DC 3)
Ripple 4) 5 VSS
Current consumption 5) 35 mA

Switching outputs PNP, open collector: Q


NPN, open collector: Q
Output current IA max. 100 mA
Light receiver, switching mode Light-/dark-switching by rotary switch
Response time 6) 0.7 ms
Max. switching frequency 7) 700/s

Test input TE sender off PNP: TE to + VS


NPN: TE to 0 V

Connection types Terminal chamber


Plug M 12, 4-pin

VDE protection class 8) V


Circuit protection 9) A, B, C, D
Enclosure rating IP 66

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS
1) Object with 90 % remission (based on 5) Without load 9) A = Vs connections reverse-polarity
standard white DIN 5033) 6) With resistive load protected
2) Average service life 100,000 h 7) With light/dark ratio 1:1 B = Inputs/outputs reverse-polarity
at TA = + 25 C 8) Reference voltage 50 V DC protected
3) Limit values C = Interference suppression
4) Must be within VS tolerances D = Outputs overcurrent and short-
circuit protected

Order information
Type Part no.
WLL 260-F 240 6 020 064
WLL 260-F 440 6 020 065
WLL 260-E 240 6 020 063

SENSICK CATALOGUE 269


WLL 260 Photoelectric switches for fibre-optic cable, red light -- UC

Dimensional drawing
Scanning range
max. 800 mm
25 63

1.5
Through-beam systems 4

Scanning distance
max. 65 (110) mm
Proximity systems
1

77.5
12
Wide range of fibre-optic cables 2
for through-beam and proximity 3

39.5
applications

19.5
Easy adaption of fibre-optic cable 5

using cap nut

5.5
3

5.5
19.5
Adjustable sensitivity 50 5.5
Terminal chamber, at bottom or rear 5.5 61

Universal current supply, relay


output, SPST, timer optional Adjustments possible 1 Centre of optical axis, receiver
WLL 260-S 240 WLL 260-R 240 2 Centre of optical axis, sender
3 Cable entry gland 1/2HH PF thread for cable
diameters from 6 to 10 mm optionally at
bottom or rear
4
4 LED signal strength indicator, red
OUTPUT TIMER
SENS.

6 1 0 5 Through hole l 5.2 mm on both sides


SENS.

6
L.ON D.ON 0.1 5(SEC)

for M 5 hex nut


MODE

1 2 3 4

7 1 1 6 Sensitivity adjustment
L. ON D. ON

MODE
MODE

7 7 Light/dark rotary switch


TIMER

4 NORMAL
3 ON.D.
2 OFF.D.
1 O.S.D.

8
L.ON = light-switching,
4 1 3 1 D.ON = dark-switching
9 8 Time range control
3 2 4 2
9 Terminals
1 0 Red LED status indicator, switching output
active
1 1 Time delay selector switch
O.S.D. = One Shot
OFF.D. = OFF delay
ON.D. = ON delay
Normal = No delay

Connection type Time delay

C   V WLL 260-S 240


WLL 260-R 240
t = 0.1 5 s

Light
beam Uninterrupted
Mode Interrupted
NORMAL ON
OFF
ON
1 23 4 OFF
O.S.D. ON
T T T OFF
ON
1 23 4 T T T OFF
OFF.D. ON
Accessories page Terminals T T T OFF
ON
Mounting brackets* 510
1 23 4 T OFF
Fibre-optic cable 528 1 ON
V DC ON.D.
T
OFF
* included with delivery 2 V AC ON
1 23 4 T T T
OFF
3
Switching mode: X light-switching
4 x dark-switching

270 SENSICK CATALOGUE


WLL 260

Technical data WLL 260- S 240 R 440

Suitable fibre-optic cable Fibre-optic cable series LIS/LBS


see page 552
Scanning distance/ranges Depends on the fibre-optic cable used
Through-beam system
Scanning distance, max. typical 1) 0 . . . 65 mm
0 . . .110 mm w. special fibre-optic cable
Scanning range 1) 0 . . . 50 mm
0 . . . 90 mm w. special fibre-optic cable
Proximity system
Scanning range, max. typical 0 . . . 800 mm
Operating range 0 . . . 700 mm
Sensitivity Adjustable, potentiometer 270

Light source 2), light type LED, visible red light


Light spot diameter Depends on scanning range
Aperture fibre-optic cable Approx. 65

Supply voltage VS3) 12 . . . 240 V DC


24 . . . 240 V AC
Power consumption 5 VA

Switching output Relay, SPST, electrically isolated


Switching current IA max. 4) 3 A/240 V AC; 3 A/30 V DC
Light receiver, switching mode Light-/dark-switching by rotary switch
Response time 20 ms
Max. switching frequency 5) 25/s

Time delays With indicator LED: switching


output active
Switch position: 1 O.S.D. 1: One shot
2 OFF.D. OFF delay tOFF
3 ON.D. ON delay tON
4 Normal No delay
Time range Adjustable, 0.1. . . 5 s;
potentiometer 270

Connection type Terminal chamber

VDE protection class 6) V


Circuit protection 7) A, C
Enclosure rating IP 66

Ambient temperature TA Operation 25 C . . . + 55 C


Storage 40 C . . . + 70 C
Weight Approx. 120 g
Material Housing: ABS
1) Object with 90 % remission (based on 3) 10 % 6) Reference voltage 50 V DC
standard white DIN 5033) 4) Provide suitable spark suppression for 7) A = Vs connections reverse-polarity
2) Average service life 100,000 h inductive or capacitive loads protected
at TA = + 25 C 5) With light/dark ratio 1:1 C = Interference suppression

Order information
Type Part no.
WLL 260-S 240 6 009 504
WLL 260-R 240 6 009 503

SENSICK CATALOGUE 271

Potrebbero piacerti anche