Target of this Workshop

Give you an overview about the basic functions in WinCC OA Video

Show you how to integrate WinCC OA Video in your Project

Show you how to configure and use WinCC OA Video


SIMATIC WinCC Open Architecture VIDEO
What is WinCC OA Video ?

Enables native integration of video management functions in a WinCC OA SCADA project.

Allows highly customized project-specific architectures, video features and user interfaces to be
implemented by the SCADA integrator for the customer.

Due to the open architecture of WinCC OA these individual project solutions can be maintained and
enhanced in the long term.

As with the WinCC OA SCADA applications, the project-specific video application changes can be made
online during system operation.
SIMATIC WinCC Open Architecture VIDEO
Benefits

SCADA and Video management in one system

Software based, digital and vendor neutral video management system with
redundant capability

Native Integration of video management functions into the WinCC OA


SCADA project

The configuration, operating messages and commands are stored in data


points. Changes can be made during system operation

It can be operated in parallel to the SCADA system in a common system, as


well as a separate system in the composite system as a distributed system
SIMATIC WinCC Open Architecture VIDEO
Benefits - SCADA and Video management in one system

WinCC OA Display Server offers a software multi-decoder for


the implementation of a video wall on the basis of standard
PCs. The number of graphic cards and monitors is not limited
by the software.

1, 2, 4, 6 or 24 videos can be displayed and decoded in


parallel in the video wall

Standard graphic object library for easy creation of SCADA


screens with video objects
SIMATIC WinCC Open Architecture VIDEO
Benefits

WinCC OA VIDEO - Free choice of video techniques

Image sources according to ONVIF 2.0 (Profile S) are supported

Additionally the common image source standard RTSP is supported

Cameras and video encoders with following video compression methods


are supported:

H.264
MPEG4
Motion JPG
SIMATIC WinCC Open Architecture VIDEO
Benefits - Free choice of video techniques

Supported image sources

ABUS Security-Center GmbH & Co KG


AXIS Communications GmbH
Basler AG
Bosch Sicherheitssysteme GmbH
D-LINK
MOBOTIX AG
MOXA
Santec Video Technologies
SANYO Europe
Siemens AG
UTC
Sony
Samsung

Note: detailed list of supported hardware is availble in the WinCC OA Video documentation
SIMATIC WinCC Open Architecture VIDEO
Requirements

WinCC OA Version 3.13

Supported operating systems:

Windows 7 Professional/Ultimate/Enterprise (32-Bit/64-Bit)


Windows 8 Professional/Enterprise (32-Bit/64-Bit)
Windows Server 2008 Windows Server 2008 R2 SP1 (64-Bit)
Windows Server 2012 Windows Server 2012 (64-Bit)

The installed vimacc services require the Microsoft Visual C++ 2010 Redistributable Package which is
automatically installed during the WinCC OA setup

Activate all used TCP ports for firewalls and setup the name resolution to IPV4 addresses over DNS,
NETBIOS or Hosts files.
SIMATIC WinCC Open Architecture VIDEO
License requirements

A Valid WinCC OA license file. Following license video-keywords are available:


video_in: Number of video inputs
video_out: Number of simultaneously displayable video streams over all workstations and
displayservers.
video_rec: Number of video streams which can be recorded

A vimacc video license (video options file "LicenseFeatures.opt") as well as a signature file
("LicenseFeatures.sgn") saved in the WinCC OA installation directory.
SIMATIC WinCC Open Architecture VIDEO
Installation options

Video Explorer

This option installs the WinCC OA sub project.

This option must be installed on all Computer, that will be


used as WinCC OA Server or WinCC OA Video workstation
(UI)
SIMATIC WinCC Open Architecture VIDEO
Installation options

Video Server

This option installs all Vimacc components needed for a video


server.

This option must be installed on all computers, that will be


used as Video-Server or as Video-Interface. WinCC OA
installation isn`t required on these computers.

The video server runs as an own software component.


It bundles all video streams and distributes them to all
recording or displaying components
SIMATIC WinCC Open Architecture VIDEO
Installation options

Display Server

This option installs all Vimacc components needed for a


Display Monitor.

The display monitor is a standalone software component to


display video streams of a video system.

This Option must be installed on all computer, that will be


used to display videos. WinCC OA installation isn`t required
on this computers.
SIMATIC WinCC Open Architecture VIDEO
Installation options

Export Client

This option installs all Vimacc components needed for the


Export Service.

This option must be installed on all computers, where videos


should be exported. WinCC OA installation isn`t required on
these computers.
SIMATIC WinCC Open Architecture VIDEO
Installation options

Video Recorder

This option installs all Vimacc components needed for a video


recorder.

This option must be installed on all computers, where videos


should be recorded. WinCC OA installation isn`t required on
these computers.
.
SIMATIC WinCC Open Architecture VIDEO
Vimacc video components

manual run of the script to start and


stop of vimacc services has to be done
Vimacc entries within always as administrator
Windows Start Menu:

Uninstall vimacc
Analyzing tool for experts
Start Display Monitor
Start all vimacc services
Stop all vimacc services
SIMATIC WinCC Open Architecture VIDEO
Vimacc video components

All components from vimacc are installed as services. The default start up type of the vimacc services is
Manual. Therefore, you have to launch the services after each restart of the computer or change the start up
type to Automatic.

The following services are started after running the script StartServices :
SIMATIC WinCC Open Architecture VIDEO
Vimacc video components
SIMATIC WinCC Open Architecture VIDEO
SCADA und Videomanagement in one System
SIMATIC WinCC Open Architecture VIDEO
Configuration VIDEO not redundant
SIMATIC WinCC Open Architecture VIDEO
Configuration VIDEO redundant
SIMATIC WinCC Open Architecture VIDEO
How to integrate WinCC OA VIDEO in your project

Integrate VIDEO_3.13 as a sub project into your project.


SIMATIC WinCC Open Architecture VIDEO
How to integrate WinCC OA VIDEO in your project

Start the project an import the ascii-file


VIDEO_OA_complete.dpl from the
subproject directory Video_3.13\dplist

Open the system management. A new tab


with following buttons is available:
Video Object Explorer
Camera lists
Sequences
Configurations
External events
Export
Video workstation
SIMATIC WinCC Open Architecture VIDEO
How to integrate WinCC OA VIDEO in your project

Add the following 2 managers to the console:


1. WCCOAvideoOA
2. WCCOActrl, start options: -f VIDEO_OA_scripts.lst

From now You can add and start


using video components by using
the object explorer object
SIMATIC WinCC Open Architecture VIDEO
Configuation of VIDEO Server

Chek and adjust the vimacc video server config


file AccVimaccConfig.conf in case of a
serversystem or a redundant system) .

Activate and Define the host name


for video server 1 respectively video server 2
In case of a redundant video server

Define which tasks the server should perform


In addition to the Control Interface.
The selected function is only executed if the
function itself is configured.
SIMATIC WinCC Open Architecture VIDEO
System Overview

Time and status of the last


computer name and port configuration update
number of Video Server 1
This area is displayed if
there is no video license
Status of Video Server available. ( 4 hours of
and WinCC OA video demo period)
componenets.

Status of the single


currently used license.
components

Operation mode (RC0, RC1, RC2 )


and state of the Current video master
SIMATIC WinCC Open Architecture VIDEO
Creating and Configuration of a camera object

create new object

select the camera type

Configure the camera (here the configuration panel of


an IP camera is shown)
SIMATIC WinCC Open Architecture VIDEO
Creating and Configuration of a workstation object

Each WinCC OA User Interface communicates with the video application via a workstation data point. For a
working system it is necessary that for each user interface number which is used in the system a work station data
point must be created.

Create and configure the workstation


Activate Human Interface Devices
(HID) connected to the workstation:
Joysticks , jog shuttles ,
SIMATIC WinCC Open Architecture VIDEO
Creating and Configuration of a display monitor

Adapt the AccVimaccDisplay.conf and


AccVimaccDisplay<id>.conf config files
per used monitor. Create and configure the camera (here the
Adapt the display start script configuration panel of an IP camera is shown)
vimaccStartDisplays.bat
SIMATIC WinCC Open Architecture VIDEO
Creating, Configuration and activation of recording

Each host which shall be available as recording server must have a video server or recording server installation.
Additionally the host must be configured as recording server. If the recording server shall have an video interface, it
must be specified during the host configuration

Create and configure


the recording
Activate the recording per stream
(cameras / encoder)
SIMATIC WinCC Open Architecture VIDEO
Configuration of video sequences
SIMATIC WinCC Open Architecture VIDEO
more functions

Alarm display: enables the configuration of actions as reactions to a WinCC OA DPE alert, e.g. In case of an
alert the camera_0001 is opened on the display monitor 1

FTP Alarm Receiver: In order to receive alarm images, a FTP server is set up within the Video OA system. In
case of an alert all video devices transfer their images and alerts to the server.

External events: Depending on the type, cameras or encoder can send messages via their control protocol
or a separate IP channel to VIDEO OA. This events are written on the data point element .object.device.alarm
and can be assigned to any data point element.. Currently only binary events are supported.
The events are passed as key value pair with a keyword and a value. The keyword depends on the device
type. In case of some device types it is possible to define the keyword during the device configuration

Export: Export of the recorded video streams including time information

RTSP Server (Real Time Streaming Protocol): Camera images (live or playback ) can be forwarded via
RTSP interface to external systems or external player
.
SIMATIC WinCC Open Architecture VIDEO
more functions

Crossbar: VIDEO OA allows to manage cameras which are connected to an external crossbar (see also
Configuration of analog cameras via external crossbar).

Encoder : Configuration and display of an encoder - In order to use analog cameras a fitting encoder is
necessary.

Serial device:In order to use serial junction boxes for analog cameras you have to create and configure them
beforehand. Communication with the junction box is only possible via TCP not UDP.
SIMATIC WinCC Open Architecture VIDEO
Symbol Library

The framework provides various graphical objects for easy and quick creating video applications. These objects
can be found under /panels/object/VIDEO_OA or in the VIDEO_OA object catalogue. Here are some of these
objects:

cameras cameraDisplay displayGrid


displayControl

display_keys, ewo_keys
display_slider, ewo_slider
display_playbackState
Video EWO
SIMATIC WinCC Open Architecture VIDEO
Configuration and panel examples

The framework provides 110 configuration and sample panels ready for quick use and integration in your
application. These panels can be found under /panels/VIDEO_OA or in the VIDEO_OA panels catalogue.

Panel for displaying live- and


playback stream of a camera
Panel for WinCC OA Video Management Workstation
SIMATIC WinCC Open Architecture VIDEO
Security information

Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, solutions, machines, equipment and/or networks. They are
important components in a holistic industrial security concept. With this in mind, Siemens
products and solutions undergo continuous development. Siemens recommends strongly that
you regularly check for product updates.

For the secure operation of Siemens products and solutions, it is necessary to take suitable
preventive action (e.g. cell protection concept) and integrate each component into a holistic,
state-of-the-art industrial security concept. Third-party products that may be in use should also
be considered. For more information about industrial security, visit
http://www.siemens.com/industrialsecurity.

To stay informed about product updates as they occur, sign up for a product-specific newsletter.
For more information, visit http://support.automation.siemens.com.
SIMATIC WinCC Open Architecture VIDEO

Thank you for your attention!


SIMATIC WinCC Open Architecture VIDEO
Contact page

ETM professional control GmbH A Siemens Company

Marktstrasse 3
7000 Eisenstadt
Austria
Telefon: +43 (2682) 741-0
Fax: +43 (2682) 741-52555

E-Mail:
wincc_oa.at@siemens.com

siemens.com/wincc-oa-user-days-2015

Potrebbero piacerti anche