OPERATING INSTRUCTIONS
MS2-1400
MS2-1500
MS2-1400
The suction bottle is made from polycarbonate resin strong against
shock and its mouth is large about 11 cm. In addition, since the detach-
able button and the handle can make you pour out suction things easily
and they are easy to handle.
Table of Contents
For Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cautions on Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Proper Handling
1. Preparations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2. Operations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3. Handling after Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4. Sterilization and Disinfection . . . . . . . . . . . . . . . . . . . . . . . . . 23
Reference Information (About Sterilization
and Disinfection of Suction Unit). . . . . . . . . . . . . . . . . . . . . . 26
5. Cleaning of Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6. Replacement of Exhaust Filter. . . . . . . . . . . . . . . . . . . . . . . . 29
Maintenance and Inspection
1. Daily Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2. Periodical Inspection (User Inspection) Check List. . . . . 31
3. About Scheduled Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . 33
Troubleshooting before calling a serviceman . . . . . . . . . . . 34
About Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
About the Marks Shown on This Manual . . . . . . . . . . . . . . . . 45
About Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
FOR SAFETY
This Operating Instructions contains the important safety
Warnings, Cautions and Notes for safe use of this medi-
cal equipment. Read these Operating Instructions carefully
before use and become thoroughly familiar with the opera-
tions and maintenance of this equipment.
WARNING
Failure to comply with the following items may result in seriously
dangerous condition to the patient(s) and damage(s) to the equipment
even if the equipment can be operated normally.
CAUTION
In addition to the Warnings, Contraindications and Prohibitions, the items
to be followed when using this equipment, when storing this equipment
and when performing maintenance of this equipment are described.
Failure to comply with these items may result in the troubles that normal
performance of this equipment cannot be obtained, medical practice is
threatened, or damage occurs to the equipment.
IN ORDER TO USE THE UNIT SAFELY
REQUEST
Before you will send this equipment for inspection or repair back to the
factory, empty the bottle and disinfect or sterilize it.
We cannot receive it when fear of infection is in it.
CAUTIONS ON USE
WARNING
Don't use this machine other than the skilled man.
Operate the unit under direction of medical practi-
cians or well-trained men
Maintenances and inspections should be performed
following this manual and the package insert.
Use the patient tube so that it should not be bent or
folded in any manner.
Strictly follow the specified type, dose and usage of
the chemicals.
Pour out secretion as early as possible before the
bottle becomes full.
Don't touch the power cord or the power supply
plug with wet hands.
The patient tube, suction bottle, accessories of suc-
tion bottle, and catheter holder should be sterilized
after washing.
(When this equipment is used at home, sterilize and
disinfect them as necessary.)
The consumables should be replaced periodically.
When replacing parts, use always the genuine parts
of our company.
Dont block the ventilation air outlet on the rear of
the housing.
When unplugging the power cord, hold it by the
plug. Pulling on the wire can cause the damage,
electrical shock and fire.
If secretion is suctioned and has entered in the suc-
tion pump side, it is very dangerous that the piping
is chocked inside the tube by the secretion.
The check and inspection by the repair contractor or
the manufacturer is definitely required.
WARNING
The PTFE suction filter (an optional accessory)
degenerates gradually as the mist of the secre-
tion adheres to the filter, causing clogging. The
effect of suction filter will be down in a month or
so. Replace the PTFE suction filter with a new
one when the suction power becomes weak and
it seems that the filter clogs.
If secretion is suctioned into the PTFE suction
filter (an optional accessory), the PTFE suction
filter will be clogged even at one time, and it
may not be able to suction any more.
CAUTIONS ON USE
CAUTION
Clean and dry the patient tube, the patient tube connection port, the
suction bottle and the accessories of the suction bottle thoroughly.
If cleaning and/or drying are insufficient, it may result in mold
(black or pink mold). After use, clean and dry them thoroughly.
Insert the suction bottle holder until it comes to the top of the suc-
tion bottle. Then, place the bottle cover. If the suction bottle holder
is stopped in the middle of the suction bottle, the bottle cover may
not be closed.
Carry out periodical cleaning and check. In order to use this unit
safely long, and prevent sudden failure and the like, be sure to ac-
cept the maintenance inspection (user inspection) and scheduled
inspection. (Refer to 30th page.)
When the equipment will not be used for a long period of time, dis-
connect the power plug from the wall outlet.
When this equipment was not used for a long period of time, use it
after taking it out to check for safety, and use it.
Be careful that the metal parts and the peripherals can be so hot
during the continuous run (maximum six hours).
Do not set the Power switch to On when the suction pressure re-
mains (i.e., in the state that the vacuum gauge needle does not re-
turn to 0) in this equipment. Doing so may result in the trouble
that this equipment does not work, or fuse may blow.
When you will dispose of this equipment (inclusive of the acces-
sories and optional parts), please be directed by the administrator
of your residential area. It can cause environmental pollution.
USER INTERFACE
MS2-1400
Suction Bottle
Cover
Power Cord
Suction Bottle
Holder Patient Tube
Cover
Detachable
L - Joint
Button
Patient Tube Receptacles
Suction Bottle (right and left)
(Plastic)
Catheter Holder (1 pc.)
Suction Bottle Holder
REAR of HOUSING
Exhaust Filter
10
MS2-1500
Patient Tube
Connection Port
(Inner Diameter
6 mm)
Power Cord
Suction Bottle
Cap
Patient Tube
Cover
Suction Bottle
L - Joint
Holder
Patient Tube Receptacles
(right and left)
Suction Bottle (Glass)
Catheter Holder (1 pc.)
BOTTOM of HOUSING
Fuse Holder
Fuse
11
USER INTERFACE
STANDARAD ACCESSORIES
Check before use whether any accessories are missing.
Adapter
12
PROPER HANDLING
1. Preparations
CAUTION When using this equipment for the first time in a
day, perform the daily inspection without fail.
(Refer to 30th page.)
1 Place this equipment on the level and stable place.
2 Check that the bottle cover (suction bottle cap) and the connecting
tubes are set so securely that there may be no leak.
13
PROPER HANDLING
5 Connect a catheter and the catheter connector S6 with the patient tube.
Patient Tube
14
2. Operations
1 When the power switch is set to On, the suction pump starts suction-
ing.
2 Put a catheter in the patient's affected part such as mouth cavity, throat
or nasal cavity.
3 When the suction pressure is low or high, turn the HIGH-LOW pres-
sure control dial gently while watching the vacuum gauge dial carefully
to regulate the suction pressure to the specified value.
Cushion
Suction Bottle
Cover
LOW
HIGH
HIGH-LOW Pressure
Control Dial
(Adjusting the Suction
Pressure)
Vacuum Gauge
The more secretion in the suction bottle, the float will rise along
with the volume of the secretion until the float activates the float
stopper (the suction stop float valve). When the suction stop float
valve is activated, it reduces the infiltration of secretion to the
suction pump.
If the float stopper does not work, the float remains rose in the top
of the suction bottle. In such a case, open the bottle cover and make
sure that the float can move up and down.
Float Stopper
Float
16
When stop suctioning temporarily
When stop suctioning temporarily, hold to fix the patient tube in the
receptacle for it, and put the catheter (Example 1) or patient tube
(Example 2) in the catheter holder as illustrated below.
Patient Tube
Cathete
Patient Tube
Receptacle
Patient Tube
Receptacle Catheter
Holder
Catheter
Holder
Example 1 Example 2
17
PROPER HANDLING
Detachable Button
Suction Bottle
Holder
18
Removing the Cover for Cushion
4 Remove all the parts shown on the next page and wash them in clean
water. Be careful of the parts missing when washing them.
19
PROPER HANDLING
Patient Tube Inlet Tubing between Bottle Cover and Suction Unit
Adapter (white)
(with nozzle)
Patient Tube
Section
"O"-ring
Cover for (2 pcs) Toward the Bottle
Cushion Cover
Filter for
Cushion
Suction Bottle
Cover How to Fix the Bottle Packing
In fixing the bottle packing, match the
Bottle Packing hook on the bottle packing and the
recess on the bottle cover, and set it.
(Foolproof mechanism)
Float Stopper
Float Top Up
The float stopper has an
Float Guide orientation. Pay attention
to the orientation when
fixing it.
Float
Suction
Bottle
20
MS2-1500
Suction Bottle
Cap
Suction Bottle
Head
Up
Float Top
The float stopper has an
orientation. Pay attention
Float Guide to the orientation when
fixing it.
Float
Suction Bottle
21
PROPER HANDLING
5 Check to see that the stains are removed well. Then, disinfect or
sterilize the parts. (Refer to 23th page.)
* When using at home, sterilize and disinfect the parts as needed.
22
4. Sterilization and Disinfection
CAUTION
23
PROPER HANDLING
3. After Disinfection
After disinfection, wash out and
dry well. After disinfection, set the
suction bottle assembly as it was
before, and put it on the unit. Be
sure and put the packing in properly. Hook
(Refer to 20th page.)
In fixing the bottle cover on the
suction bottle, hook it on the bottle
holder and set it.
24
CAUTION Insert the suction
bottle holder until it
comes to the top of the
suction bottle. Then,
place the bottle cover.
If the suction bottle
holder is stopped
in the middle of the
suction bottle, the
bottle cover may not
be closed.
When not in use, the patient tube can be wrapped around the patient
tube cover. Hold the tip of the patient tube as shown in the figure.
To remove the patient tube cover, turn it counter-clockwise. (Refer to
22th page.)
Patient Tube
25
PROPER HANDLING
Reference Information About Sterilization and Disinfection of
Usable Usable (There are changes in appearance or of feeling.) Prohibited
(Type of disinfectant)
Name of typical product
(Chlorhexidine gluconate)
Hibitane solution, Hexizac solution
(Invert soaps)
Osvan solution, Hyamine solution
(Phtharal)
Disopa
(Alcohol)
Ethanol disinfectant, Isopropanol
(Sodium hypochlorite)
Milton, Purelox
* Metal corrosion
(Povidone-iodine)
Isodine
Boiling sterilization
(Inclusive of washer-disinfectors)
High pressure steam sterilization
(autoclaved sterilization)
Ethylene Oxide Gas (EOG)
disinfection
* As the bottle holder contains the stainless steel parts, metal corrosion of these parts
will occur.
Phenol, and povidone-iodine may cause crack, dissolution or coloration.
26
Suction Unit
Stain
O-ring
Tube hardening
hardening
O-ring Crystallization
deterioration inside the tube
Crack
O-ring
Pungent odor Tube hardening
hardening
Boiling sterilization and high pressure steam sterilization (autoclaved sterilization) may
cause deformation.
Note: This filter cannot be reused even it is sterilized. Replace it with a new one.
27
PROPER HANDLING
Reference Information About Sterilization and Disinfection of Suction Unit
Usable Usable (There are changes in appearance or of feeling.) Prohibited
(Type of disinfectant)
Name of typical product
(Chlorhexidine gluconate)
Hibitane solution, Hexizac solution
(Invert soaps)
Osvan solution, Hyamine solution
(Phtharal)
Disopa
(Alcohol)
Ethanol disinfectant, Isopropanol
(Sodium hypochlorite)
Milton, Purelox
Deterioration
28
5. Cleaning of Housing
Wash the dirt off the outside of the housing with a wet cloth adding a little
bit neutral cleanser, and wipe it off with a dry cloth.
CAUTION
Exhaust Filter
29
MAINTENANCE AND INSPECTION
1. Daily Inspection
CAUTION Before operation be sure to inspect the following
items.
Inspect that the AC power cord plug is not deformed.
Inspect that the appearance of the suction bottle and its accessories
shows no crack and any other abnormalities..
Inspect that the connecting parts, dial and the like are not loose, and
work smoothly.
Check that on and off of the power switch moves smooth. Check that
the vacuum gauge indicator changes smoothly when the patient tube is
folded with fingers and turning the HIGH-LOW pressure control dial.
Check whether the exhaust filter stains or not. (Refer to 29th page.)
Vacuum Gauge
HIGH-LOW Pressure
Control Dial
Patient Tube
30
2. Periodical Inspection (User Inspection)
Check List
This is a user's inspection. Make use of the following list, and inspect the
unit periodically every 3 months. (Copy P31 to 32 and use them)
Function Check
Serial No.
Inspection Date : Year, month, day Inspector :
Call the seller when function check results in wrong and request the seller
or repair contractor for repair.
31
MAINTENANCE AND INSPECTION
Crack or no Crack or
Description Equipped or not crack on deterioration, Re-
deformity, marks
appearance stain
Suction Unit Connecting
equip not equip equip not equip
Tubing
Patient Tube (with Adapter) equip not equip equip not equip
Catheter Connector
equip not equip equip not equip
S-6
Catheter Holder equip not equip equip not equip
HIGH-LOW Pressure
equip not equip
Control Dial
Power Switch equip not equip
Fuse Holder equip not equip
Vacuum Gauge equip not equip
Exhaust Filter equip not equip equip not equip
Power Cord equip not equip
Outside of Housing equip not equip
Patient Tube Cover equip not equip equip not equip
Cover for Cushion equip not equip equip not equip
Filter for Cushion equip not equip equip not equip
Others
Suction Bottle and Related Parts
MS2-1400
Suction Bottle (Plastic) equip not equip
Suction Bottle Cover equip not equip
Suction Bottle Holder equip not equip
Bottle Packing equip not equip equip not equip
MS2-1500
Suction Bottle (Glass) equip not equip
Suction Bottle Head equip not equip
Suction Bottle Packing equip not equip equip not equip
When the components are missing or degrading for spare, place orders with
the seller.
32
3. About Scheduled Inspection
In order to prevent sudden accidents and use this product in safety, the
scheduled inspection every 2 years by the manufacturer or the repair
contractor and overhaul every 5 years are required. In scheduled inspec-
tion, perform function and performance test in addition to replacement of
consumables such as rubber products.
On the structure of the unit, the longer the hours worked become, the
more the degeneration of parts progress. And also accumulations of dust,
mist suctioned and the like have progressed. It becomes difficult for the
unit to keep the ability by only performing the periodical inspection over
a certain period of time. The overhaul with the parts replacements for
new ones and a very thorough examination is essential to returning the
unit to the ability as it was. (The scheduled inspection is charged sepa-
rately.)
33
TROUBLE SHOOTING BEFORE CALLING A SERVICEMAN
Before contacting the store of purchase, serve the following remedies.
It may operate normally. If this does not remedy the phenomenon, and
when you cannot operate normally, do not disassemble the unit, but con-
tact the store of purchase.
PHENOMENON CAUSE REMADY
The pump The power cord separat- Insert the power cord in
does not ed from the wall outlet the outlet correctly. Call
run. (The or it disconnected. the store you bought after
electric moving a code and check-
power is not ing condition, when it
switched disconnected or may have
on.). disconnected.
The pump
stops occa-
sionally.
34
PHENOMENON CAUSE REMADY
35
TROUBLE SHOOTING BEFORE CALLING A SERVICEMAN
The pump The suction stop float Remove the bottle cover,
runs, but valve is activated. and separate the float from
does not (The float adheres to the float stopper. When any
suction. the float stopper.) secretion or the like is rec-
Or the suc- ognized attached to the float
tion is weak. guide, disassemble them.
After washing, cleaning
and drying, set them as they
were set before. (Refer to 20
or 21th page.)
36
ABOUT OPTIONAL ACCESSORIES
The following products are prepared as the optional accessories of Minic
S-II. Use them in order to use Minic S-II effectively.
- Optional Accessories -
Description Usage
PTFE Suction Filter Prevent the mist of the secre-
(Water breakthrough point: 14 psi) tion and the liquid moisture
(*) from flowing into the pump.
Recommend you to use this
filter for preventing infection.
With "O"-ring
Description Usage
Olive Tube Kit It is used to suction the
Component parts: nasal discharge. Since it is
Olive (ultra-small, small, large, ball) available in four different
Joint sized, it can be used from
Patient Tube (with Adapter) children to adults. It is made
Catalog number: 140030155 of silicon rubber. Suctioning
Packing unit: 1 set without damaging the nasal
cavity is possible.
38
Description Usage
Special Carry Bag With the shoulder belt
Catalog number: 200190224
supplied, it is convenient
Packing unit: 1 piece
to carry. Since the top
cover can be opened
immediately, user can
respond quickly in an
emergency.
When placing orders with the seller, specify the name of the product,
catalog number and quantity.
39
ABOUT OPTIONAL ACCESSORIES
40
2. Installation of Olive Tube Kit
Patient Tube
Joint
Olive
41
ABOUT OPTIONAL ACCESSORIES
- Replacement Parts -
42
10. Filter 11. Catheter Holder 12. Suction Bottle
* Only filter of above item Tube (blue)
Catalog number: 200190037
7. Cover for Cushion (with
Packing unit: 1 piece Catalog number: 200191262
filter)
Packing unit: 5 pieces
Catalog number: 200191256
Packing unit: 5 pieces
When placing orders with the seller, specify the name of the product,
catalog number and quantity.
43
SPECIFICATIONS
Model Minic S-II
Approval No. 22300BZX00311000
Type MS2-1400 MS2-1500
45
ABOUT DISPOSAL
When you will dispose of this unit (inclusive of the accessories
and optional parts), please be directed by the administrator of your
residential area. (It can cause environmental pollution.)
46
Memorandum
47
MANUFACTURER
SANKO MANUFACTURING CO., LTD.
SAITAMA, JAPAN
25026
ISO 9001
QMS
JET-0475 CM013
12BT000-1