Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
For RFC2544 testing, SmartClass tester can be configured in loopback mode at NodeB
side to set up a testing scenario with QT600 in MTX. This guide shows the way to
configure the SmartClass tester for Layer 3/Layer 2 RFC2544 testing at NodeB side.
For configuring Layer3 loopback testing, normally most of the setting can use the default
values, but for tagging setting and IP setting, users need to configure the actual VLAN
1.4 Select Link Settings, and configure the link setting as picture below:
1.5 Back to upper menu, select Ethernet settings and configure the
Ethernet settings as picture below:
1.6 Back to upper menu, select Tagging settings and configure the Tagging
mode as VLAN, VLANID as NodeB VLAN ID, user priority as 0.
1.7 Back to upper menu, select IP settings and configure the ARP Mode as
Enable, Dest Addr as QT IP, Source Addr as NodeB IP, Subnet Mask
as required subnet mask, Default Gateway IP as gateway IP.
1.8 Back to upper menu, select Ethernet Filter and configure Ethernet
Filter as below:
1.9 Back to upper menu, select IP Filter and configure IP Filter as below:
1.10 Back to upper menu, select Timed Test and configure Timed Test as
below:
1.11 Back to Electrical L3 Loopback menu, and select 3. Action to start the
loopback.
1.12 After start testing, the testing results can be viewed in Result->Link
Count Page. If the both Transmitted Frames amount and Received
Frames show throughput, it means the testing is succeed to run.
Otherwise, there may be some problems in this test.
Layer2 Loopback is similar to layer3 but dont need to configure the IP settings. The
configurations are same on the link setting, filter and timed test parts. Basically, users
2.3 Select Ethernet settings and configure the Ethernet settings as picture
below:
2.4 Select Tagging settings and configure the Tagging mode as VLAN,
VLANID as NodeB VLAN ID, user priority as 0.
2.5 Back to Electrical L2 Loopback menu, and select 3. Action to start the
loopback.