X-ray Radiographic System Based on High Frequency

Inverter

EVA-HF325/525
Operation Manual
ver 3.2

COMED Medical Systems Co.,Ltd.


Table of Contents

1. Quality Guarantee ---------------------------------------------------- 4

2. Introduction -------------------------------------------------------- 5

3. Composition ---------------------------------------------------------- 7
3.1 X-Ray radiographic device ----------------------------------------- 7
3.2 Options ------------------------------------------------------------- 7
3.3 Others ----------------------------------------------------------------- 7

4. Using safety Guide ----------------------------------------------- 8


4.1 Safety rule ---------------------------------------------------------- 8
4.2 electronic safety --------------------------------------------------- 10
4.3 Environmental risks and displacement --------------------------- 11

5. Specifications ------------------------------------------------------- 12
5.1 X-Ray tube device --------------------------------------------------- 12
5.2 X-Ray high-voltage device ----------------------------------------- 12
5.3 X-Ray Management ------------------------------------------------- 12
5.4 Instrument structure ------------------------------------------------ 13
5.5 Optional specifications -------------------------------------------- 13
5.6 using voltage -------------------------------------------------------- 13
5.7 Size and Weight ----------------------------------------------------- 13

6. Using environment condition --------------------------------- 14

7. Instrument running and Operation explanation -------- 15


7.1 handle bar ----------------------------------------------------------- 15
7.2 Photographic table -------------------------------------------------- 16
7.3 Bucky stand -------------------------------------------------------- 16
7.4 Cassette tray ------------------------------------------------------- 16

2
COMED Medical Systems Co.,Ltd.
8. X-RAY operating method ----------------------------------------- 17
8.1 OPERATION PANEL operating method -------------------------- 17
8.1.1 Display lamp ------------------------------------------------- 18
8.1.2 Operating panel PART 1 -------------------------------- 19
8.1.3 Operating panel PART 1 ----------------------------------------- 24
8.1.4 APR(Anatomical Programmed Radiography) ----------------- 26

9. Maintenance and repairing ---------------------------------- 28

10. Broke down and measures ------------------------------------ 39

11. Radiography condition table ----------------------------------- 31

12. Radiography skill ----------------------------------------------------------- 33

13. Application form of the protecting structure investigation - 40

3
COMED Medical Systems Co.,Ltd.
1. Quality Guarantee
Guarantee Range and Period
All Comed Co.,Ltd.s products are sold with 1 year guarantee. During the 1 year
guarantee period, any damage due to poor delivery and mechanical defect will receive
free service.

Under the following circumstances, little charge will be requested.

1) Any damage occurring after the guarantee period has elapsed.


2) Any damage due to natural disasters(fire, earthquake, lightening, and etc.).
3) Any damage due to misusage/treatment or carelessness after the installment.
4) Any damage due to poor repairing or remodeling done by non- Comed engineer or
non-authorized person.

Requirements for Service Requests


When a problem/damage occurs, stop the system and re-check the relevant DATA in the
operating manual.
Before requesting for repair, turn off the system, verify the model and product number,
as well as the date of purchase. Then, call the specified service department.

External damage does not account for return or exchange of products.


Comed Co.,Ltd. is not responsible for minor and indirect damages.
Comed Co.,Ltd. is not responsible for damages after 1 year of guarantee
period.
Quality guarantee comes before particular suitability guarantee or any
other guarantees.

Comed Medical Systems Co.,Ltd.

4
COMED Medical Systems Co.,Ltd.
2. Introductions
This manual is made for using instrument safe and rightly. This manual not respect
changing the running mode and safety from external damage to instrument.

This high frequency inverter type of the photo/imaging system is operated by the built-in
operation program. It is comfortably designed to satisfy the operator's comfort as well as to
enhance the efficiency and the quality of X-ray. Operator can easily select or change the
necessary conditions for necessary photographs/images.
(1) This manual is made for operating instrument safe and rightly

(2) This instrument must following this manual process.

(3) Read this manual carefully before using the instrument. Keep this manual closely
for referring later.

(4) EVA HF325/525 is a radioactivity medical instrument and using under the medical
management. So it needs the authorized person who has the know-how about the
X-ray.

(5) High voltage generating circuit provides stable X-ray out put with little radiation
through rectifying electric wave method.

(6) X-ray tube system is made in rotary bipolar method which uses two foci(small
focus 1.0mm/ large focus 2.0mm) to enhance its durability.

(7) Control panel consists of x-ray controller and communication cable. So it can dealt
the X-Ray irradiation and control from the long distance. LCD display allows the
operator to irradiate at best X-ray irradiating conditions.

(8) Table and stand are connected into one single unit. Therefore, no extra stand rail
work is needed. Table moves in four directions to provide easy-positioning.

(9) Temperature sensor is attached to prevent TUBE from overheating. micom-


controller senses the temperature and protects the TUBE becoming too hot.

(10) X-ray Controlling device and high voltage radiation device are all built in one unit.
Therefore, it is easy to convey and possible to install even in a small space.

5
COMED Medical Systems Co.,Ltd.
(11) PSU(POWER STORAGE UNIT) does not need much power and works efficiently
under 2kW~3kW. Therefore, you could reduce electricity rate and save electricity cost.
(PSU OPTION)

(8) Wide selecting modes allow the operator to combine and create various working
conditions.

Only the legally authorized person(doctor, radio-diagnosis technician, X-ray diagnosis


engineer) has the permission to operate the system

6
COMED Medical Systems Co.,Ltd.
3. Composition

This is divide by following that X-Ray radiography stand, an accessory, option etc..

3.1 X-Ray radiography device


X-Ray tube
STAND
HANDLE BAR
COLLIMATOR
TABLE
RAIL
CONSOLE DISPLAY
CONTROLLER
HIGH TRANS

3.2 Option
CEILING (Ceiling support)
BUCKY STAND (Ground support)
PSU
STAND (Ceiling support)

3.3 The others


User Manual

7
COMED Medical Systems Co.,Ltd.
4. Using safety Guide

4.1 Safety rule

Comed Co, Ltd designs and builds this instrument complying with
related safety requirement.

Only the authorized personnel can remove the covers and/or have access to
the components under tension.

WARNING
This device has not been designed to be used in environments where vapours,
anaestethic mixes flammable with air, or oxygen and nitrous oxide can be
detected.

Avoid pouring water, even accidentally, or other liquids into the device, as this
cause short-circuits.

Before cleaning the device, please disconnect it from the line voltage

Wherever necessary, use the accessories, such the leaded aprons, to protect the
patient from radiation

While performing the radiography, no one, apart from the operator and the patient,
must remain in the room.

EVA-HF 325/525 has been built to support a continuous operation at intermittent


load.

Cooling down the storing heating at a radioactivity origin, must follow the
described use cycles.

8
COMED Medical Systems Co.,Ltd.
WARNING !
Though the X-ray quantity supplied by radioactivity units is quite low and
distributed on a small surface, the operator must adopt the precautions and fit
protections for the patient and himself, during the execution of radiography. It
is advisable to control the X-ray emission from a protected area, by means of
a remote control. If it is necessary to operate near the patient, stay as far as
the cable of the remote control allows it, or at least 2m far both from the X-ray
source and from the patient.

9
COMED Medical Systems Co.,Ltd.
4.2 Electronic safety

Before handling the system, be sure to check the following instructions.


Make sure the source power voltage and capacity match up to
AC220-240VAC(37.5kW/40kW). (When using PSU, DC voltage 370VDC)

Make sure all the connecting terminals(collimator, high voltage cable, bulky, and etc.) are
properly connected.

Make sure the system's grounding is perfectly done. (If the grounding is imperfect, there
may be noise.)

Warning !
Through this unit has been designed with a quite acceptable protection level
from electromagnetic interferences, it is advisable to install it a certain
distance from electrical energy transformation chambers, from Uninterruptible
Power Supply(UPS) units, from portable receiving-transmitting units.

Mobile telephones are only admitted at a distance of more than 1,5 m from
any component if the device.

Other medical instruments and devices that must be used in the same
installation area of the unit must comply the Electromagnetic Compatibility
rules in force.

Non-complying instruments, of which the poor immunity from electromagnetic


fields in well known, must be installed at least 3m far from the EVA-
HF325/525 and supplied by a different electrical line.

4.3 Environmental risks and displacement

10
COMED Medical Systems Co.,Ltd.
The device contains in some of its parts, materials and liquids that at the end of the units
life, must be disposed of at the fit disposal centers.

Particularly the device contains the following materials and components

Tube: dielectric oil, lead, copper, iron, aluminium, glass, tungsten,


beryllium.
Control, HIGH TRANS : iron, dielectric oil, brass, acryloyl, non-biodegradable
plastix material packaging
Instrument structure : iron, brass, non-biodegradable plastix material packaging

Warning !
Part dismantle of the instrument must performed by the staff of COMED
Co, Ltd or qualified technicians authorized personnel

COEMD Co, Ltd or the agent is not responsible for the displacement
of the device performed by the user and for the related costs.

11
COMED Medical Systems Co.,Ltd.
5. Specifications
5.1 X-ray tube device (X-ray TUBE)
Focal Spot :
Large Focus : 2.0 mm
Small Focus : 1.0 mm
Anode Speed :
50 Hz : 2700 rpm (Min)
60 Hz : 3200 rpm (Min)
Maximum Anode Heat Dissipation Rate : 667Hu/s

5.2 X-ray high-voltage device


1) EVA-HF325
Tube-current adjustment : 25mA ~ 300mA
Tube-voltage adjustment : 40kV ~ 125kV
Time adjustment : 0.001 ~ 5sec
Rated :
125kVp / 200mA / 1sec(200mAs)
90kVp / 200ma / 3sec(600mAs)
total 0.025mAs ~ 600mAs possibly adjustment

2) EVA-HF525
Tube-current adjustment : 25mA ~ 500mA
Tube-voltage adjustment : 40kV ~ 125kV
Time adjustment : 0.001 ~ 5sec
Rated :
125kVp / 200mA / 1sec(200mAs)
90kVp / 200ma / 3sec(600mAs)
total 0.025mAs ~ 600mAs possibly adustment

5.3 X-ray control


method MICRO PROCESSOR control digital display
radiography MANUAL
APR(Anatomical Programalbe Radiography)

12
COMED Medical Systems Co.,Ltd.
5.4 Instrument structure
1) Tube
Forward-backward movement range : 185mm
X-axis center rotating angle range : over 90
Z-axis center rotating angle range : over 90
Max height : above ground 1720 mm (Tube photosphere standard)
Min height : above ground 650 mm (Tube photosphere standard)
Up-down movement range : 1170 mm
Left-right movement range : 1940 mm
2) TABLE
Forward-backward movement range : 200mm
Left-right movement range : 600mm

5.5 Optional specifications


All-in-one type
Ceiling support type

5.6 Using voltage


Power single phase 220V
Outward Power 37.5kW/40kW

5.7 Size and weight


Height : 2070 mm
Width : 2600 mm
Range : 1350 mm
Weight : 398 Kg

13
COMED Medical Systems Co.,Ltd.
6. Using environmental condition

When using this instrument avoid following the place

The place that direct rays


The place that a lit of dust and high humidity
The place that badly ventilated
The place that saltiness
The place that has chemical material and gas
The place that high vibration

Keep the temperature and humidity for the normal running.


Possible Storage Temp.,Humidity Range: 5 40C , 5 90%RH

Possible Usage Temp.,Humidity Range: 10 35C , 30 85%RH

Best Preferred Temp.,Humidity Range: 17 23C , 40 60%RH

7. Instrument running and operation instructions

14
COMED Medical Systems Co.,Ltd.
Preparations
1)Turn on the main power supply switch. Supply power to X-ray controlling system
and check out for any extraordinary or odd.
2) Warm up the system for at least 30 minutes before taking radiography.

7.1 HANDLE BAR operating method

When this button pressed condition, TUBE can rotate to


WALL BUCKY and side of the patients

When this button pressed condition, TUBE can move


forward and backward direction.

When this button pressed condition, TUBE can move up


and down direction.

When this button pressed condition, TUBE can move left


and right direction.

When this button pressed condition, body of the STAND


can rotate.

When this button pressed condition, TUBE can move all


direction.

15
COMED Medical Systems Co.,Ltd.
7.2 Radiography TABLE operating method
Using table at this device select 4way table that operator easily decide radiography
part of the patients body.
- Placed patient over the bed, pressed button of the collimator, and under pressed the
foot switch. The operator placed radiography part of the patients.
- When Table and Grid Center are same location that sounded buzzer like beep~.

7.3 BUCKY STAND operating method


1) Placed the patients front of the bucky stand, and decide the place adjust the patients
body size that move the cassette tray up and down
2) Input the cassette with a file to the Cassette holder
3) X-ray output window of the tube look at the bucky stand direction, and adjust angle of
the handle bar to 90 degree.
4) Press the button of collimator and decide the position with pressing the up /down
button of the handle bar that the center of the light to the radiography target part of
the patient.

7.4 CASSETTE TRAY operating method


1) At first placed the radiate position of the patients, and move the center light of the
collimator to the radiate position.
2) Pull out the cassette hold and move the tray to the radiated position and the tube in a
straight line.
3) Input cassette within the film and fixed. And the cassette holder push into the tray that
cassette fixed right position.

16
COMED Medical Systems Co.,Ltd.
8. X RAY operating method

8.1 OPERATION PANEL operating method

8.1.1 Display lamp

A READY display lamp

EXPOSURE display
B lamp

SMALL FOCUS display


C lamp

LARGE FOCUS display


D lamp

E ERROR display lamp

F OVER LOAD display


lamp

17
COMED Medical Systems Co.,Ltd.
A. READY display lamp

While the READY S/W is pressed, this lamp turn on.


B. EXPOSURE display lamp

When pressed the READY S/W and press the EXPOSURE S/W this lamp turned on
during the X-ray radiation times
C. SMALL FOCUS dislplay lamp

If the focus of the Tube is the small focus, this display lamp will turn on.
(below 4mAs condition.)
D. LARGE FOCUS display lamp

If the focus of the Tube is the large focus, this display lamp will turn on.
(over 4mAs condition.)
E. ERROR display lamp

After the controller self-exam. if error occurred then error display lamp will turn on.
F. OVER LOAD display lamp

Exceed the capacity of the tube or abnormal condition that overload display lamp will
turn on.

18
COMED Medical Systems Co.,Ltd.
8.1.2 Operating panel PART1(Operating panel left side)

A POWER OFF S/W

B POWR ON S/W

C kV adjustment S/W

D mA adjustment S/W

E TIME adjustment S/W

F DENSITY adjustment S/W

19
COMED Medical Systems Co.,Ltd.
G TUBE 1 SELECT S/W

H TUBE 2 SELECT S/W

I TIME, mAs CHANGE S/W

AUTO EXPOSURE
J CONTROL POSITION S/W

K BUCKY 1 SELECT S/W

L BUCKY 2 SELECT S/W

M BUCKY 3 SELECT S/W

20
COMED Medical Systems Co.,Ltd.
A. POWER OFF S/W

Press this button, all power turned off.

B. POWR ON S/W

Press this button, all power turned on.

C. kV adjustment S/W

The button adjust the value of the Kv. Press upper triangle, increase the value of the
Kv and press downward triangle, decrease the value of the Kv.

D. mA adjustment S/W

The button adjust the value of the mA. Press upper triangle, increase the value of the
mA and press downward triangle, decrease the value of the mA.

21
COMED Medical Systems Co.,Ltd.
E. TIME adjustment S/W

The button adjust the time of the radiation. Press upper triangle, increase the time of
the radiation and press downward triangle, decrease the time of the radiation.

F. DENSITY adjustment S/W

The button adjust the density. (Not use at this machine.)

G. TUBE 1 SELECT S/W

Select the 1st tube, when use two tubes.


(Only one tube use at this machine.)

H. TUBE 2 SELECT S/W

Select the 2nd tube, when use two tubes.


(Not use at this machine.)

22
COMED Medical Systems Co.,Ltd.
I. TIME, mAs CHANGE S/W

If press this button then display screen change time to mAs


(If press one more then change mAs to time...)

J. AUTO EXPOSURE CONTROL POSITION S/W

Three button like above the picture, When using AEC functions.
(Not use at this machine)

K. BUCKY 1 SELECT S/W

1st Burky button. Press this button then select the table burky running at this
instrument.

L. BUCKY 2 SELECT S/W

Optional specification. If has the burky-stand. Press this button then select the burky
running at burky-stand.
M. BUCKY 3 SELECT S/W

Functions select burky running of the other instrument.

23
COMED Medical Systems Co.,Ltd.
8.1.3 Operating panel PART1(Operating panel right-side)

A Body size SELECT S/W

B Body part SELECT S/W

Detail body part SELECT


C S/W

D Save condition S/W

E Gree n READY S/W

F Yellow
w
EXPOSURE S/W

A. Body size SELECT S/W

The button select the body size, it divide patients to large, medium, small and child.

B. Body part SELECT S/W

The button selects the body part. The button select the wanted part at a picture.

24
COMED Medical Systems Co.,Ltd.
C. Detail body part SELECT S/W

The button selects the detail body part. Press the wanted part from the right LCD
window.
D. Save condition S/W

The button saves the condition. When save the condition, press this button 2 second.
E. READY S/W

Green

READY S/W. While pressing this button, READY display lamp turned on.
F. EXPOSURE S/W

Yello
w

EXPOSE S/W. During turning on the READY display lamp, press this button then the
X-ray is generated.

Warning !
Please the X-RAY ON KEY switch press until end of the X-RAY
radiation for completing the X-ray radiation.

25
COMED Medical Systems Co.,Ltd.
8.1.4 APR(Anatomical Programable Radiography) saving method

See operating panel menu.


1. Select the body size.

Large

Medium

Small

Child

2. Select the body part.

SKULL

PNS

CHEST

SPINE

ABDOMEN

UPPER EXTREMITY

LOWER EXTREMITY

3. Select the detail body part.

(See above display window and select one from 6 kind of the detail body part then
marked symbol .)

26
COMED Medical Systems Co.,Ltd.
4. Select the value of Kv and mAs.

5. When save the setting condition, press the SET/SW until sounding the
buzzer(about 1 second).

27
COMED Medical Systems Co.,Ltd.
9. Maintenance and repairing

General

We recommend this instrument always have a periodical inspection every year for
confidence and renew

Must have a periodical inspection by the authorized technician.

CLEANING

No a periodical cleaning cycle, cleaning the unit when the instrument become dirty
after operating

To clean the main-part of the instrument, at first turn power off and pull the plug out
from the socket then do cleaning.

When cleaning the main-part of the instrument, using a soft piece of close and clean
softly for not scratching the main-part

28
COMED Medical Systems Co.,Ltd.
10. Broke down and measures
ERROR MESSAGE
When specific ERROR occurred at this machine, easily recognized the error because
CONSOLE DILSPLAY window show the ERROR MESSAEG due to self-exam functions
of the CONTROLLER.

ERROR
Reason
CODE
E 29 Filament not pre-heating

E 30 Filament over-heating

Not charging at the input power storing


E 31
condenser.

E 32 Tube over-heating.

E 00 X-ray radiation interrupting.

When occur the Error code, Turn power off and contact the SERVISE
PART.

Collimator lamp replace method


1. back-cover release

Release the bolt by the hand, which display two circles from above picture. Lifting and
pull out back-cover of the collimator.
2. Lamp back-cover release

29
COMED Medical Systems Co.,Ltd.
Release the bolt a little by the screwdriver, which display the circles from above
picture. Push the arrow-direction and pull the lamp back-cover.

3. Lamp pull out

pull out the lamp the arrow-direction , which display the while-circle from above picture.

4. Lamp sticking
Sticking of the lamp is reversed pull out of the lamp
Warning Replacement lamp(new lamp) never touch by the hand
(Long-time running lamp is very hot, so dont touch.)

30
COMED Medical Systems Co.,Ltd.
11. Radiography condition table
Divisi Child Small
on
Body part kVp mA mAs Grid kVp mA mAs Grid
AP/PA 70 200 10 1 73 200 15 1
Lateral 68 200 10 1 70 200 15 1
Townes 70 200 15 1 73 200 20 1
SKULL
PA 50 100 10 . 73 200 15 1
Mandible
Axial Later 50 100 7 . 70 200 15 1
Nasal Lateral 43 100 3.2 . 43 100 5 .
Waters 70 100 10 1 70 100 30 1
PNS Caldwell 70 100 7.5 1 70 100 20 1
Lateral 70 100 7.5 1 70 100 15 1
PNS
Law 70 100 5 1 75 100 20 1
Mastoid Stenvers 65 100 5 1 72 100 10 1
Towns 70 100 7.5 1 72 100 20 1
PA 70 100 4 . 80 200 15 2
Chest
Lateral 70 100 6 . 85 200 20 2
AP 50 100 6 . 70 150 20 2
CHEST Rib
Both obliq 55 100 6 . 70 200 25 2
Clavicle AP 50 100 7.5 . 70 200 15 2
Shoulder AP 50 100 7.5 . 70 200 15 2
Supine 55 100 7.5 . 70 200 20 1
Erect 55 100 7.5 . 65 200 20 1
KUB 55 100 7.5 . 65 200 20 1
ABDOMEN
AP 55 100 7.5 . 70 200 20 1
Pelvis
Lateral 60 100 10 . 85 200 30 1
Hip Lateral 55 100 5 . 72 200 20 1
AP 50 100 3 . 56 200 15 2
C-spine
Lateral 55 100 5 . 52 200 15 2
AP 55 100 5 . 58 200 20 1
SPINE T-spine
Lateral 60 100 10 . 65 200 25 1
AP 55 100 7.5 . 70 200 20 1
L-spine
Lateral 65 100 10 . 85 200 30 1
Finger AP 40 100 1.5 . 40 100 4.5 .
Hand AP 45 100 2 . 45 100 4.5 .
Upper Wrist AP 50 100 2 . 50 100 4.5 .
EXTREMITY Foream AP 50 100 3.2 . 50 100 7 .
Elbow AP 50 100 3.2 . 50 100 7 .
Humerus AP 50 100 3.6 . 55 100 9 .
Foot AP 45 100 3.2 . 45 100 4 .
Ankle AP 50 100 3.2 . 53 100 4 .
Lower Tibia AP 50 100 3.2 . 55 100 4 .
EXTREMITY Knee AP 50 100 5 . 57 100 6 .
Merchant 53 100 5 . 60 100 6 .
Femur 55 100 4 . 60 100 6 .

31
COMED Medical Systems Co.,Ltd.
Divis Medium Large
ion
Body part kVp mA mAs Grid kVp mA mAs Grid
AP/PA 70 200 20 1 75 200 25 1
Lateral 75 200 15 1 75 200 20 1
Townes 75 200 25 1 80 200 30 1
SKULL
PA 70 200 20 1 70 200 25 1
Mandible
Axial Later 70 200 15 1 70 200 20 1
Nasal Lateral 45 100 5 . 45 100 7 .
Waters 80 100 25 1 85 100 30 1
PNS Caldwell 70 100 30 1 75 100 30 1
Lateral 75 100 20 1 78 100 20 1
PNS
Law 78 100 30 1 85 100 30 1
Mastoid Stenvers 70 100 20 1 73 200 20 1
Towns 73 100 30 1 78 200 30 1
PA 90 200 8 2 95 200 10 2
Chest
Lateral 88 200 20 2 95 200 25 2
AP 70 200 20 2 73 200 25 2
CHEST Rib
Both obliq 75 200 30 2 80 200 30 2
Clavicle AP 70 200 20 2 70 200 25 2
Shoulder AP 70 200 20 2 70 200 25 2
Supine 75 200 45 1 75 200 50 1
Erect 75 200 45 2 75 200 50 2
KUB 75 200 50 1 75 200 55 1
ABDOMEN
AP 72 200 50 1 75 200 55 1
Pelvis
Lateral 85 200 50 1 95 200 50 1
Hip Lateral 75 200 25 1 80 200 25 1
AP 60 200 25 2 64 200 30 2
C-spine
Lateral 60 200 30 2 65 200 30 2
AP 62 200 25 1 66 200 30 1
SPINE T-spine
Lateral 72 200 40 1 72 200 60 1
AP 72 200 30 1 76 200 40 1
L-spine
Lateral 90 200 45 1 95 200 60 1
Finger AP 42 100 2.8 . 45 100 2.8 .
Hand AP 45 100 5.5 . 48 100 6 .
Upper Wrist AP 50 100 5 . 50 100 7 .
EXTREMITY Foream AP 48 100 7 . 50 100 9 .
Elbow AP 50 100 8 . 50 100 10 .
Humerus AP 46 100 10 . 50 100 15 .
Foot AP 48 100 8 . 48 100 10 .
Ankle AP 55 100 7 . 55 100 10 .
Lower Tibia AP 54 100 10 . 55 100 10 .
EXTREMITY Knee AP 55 100 15 . 60 100 15 .
Merchant 60 100 8 . 60 100 10 .
Femur 60 100 15 . 55 100 15 .

Note !
Above condition table is not the absolute value,
So operator adjust and save to using above condition

32
COMED Medical Systems Co.,Ltd.
11. Radiography skill

HAND PA HAND Lateral

Wrist PA Wrist Lateral Forearm AP Forearm Lateral

33
COMED Medical Systems Co.,Ltd.
Humerus AP Humerus Lateral Elbow AP

Glenoid fossa Shoulder axial Elbow Lateral

34
COMED Medical Systems Co.,Ltd.
FOOT AP FOOT Lateral Ankle joint AP

LEG AP LEG lateral Ankle joint lateral

35
COMED Medical Systems Co.,Ltd.
KLEE joint AP KLEE joint Lateral Femur AP

Hip joint AP Hip joint Lateral Femur Lateral

36
COMED Medical Systems Co.,Ltd.
Pelvis AP Pelvis inlet Pelvis oblique

C spine AP C spine lateral C-Open Mouth C-oblique

Chest AP Chest Lateral

37
COMED Medical Systems Co.,Ltd.
COCCYX AP COCCYX Lateral Pelvis outlet

L-spine AP L-spine Lateral L-spine oblique

38
COMED Medical Systems Co.,Ltd.
Skull AP Skull Lateral Skull Town's

PNS AP PNS Lateral PNS waters

39
COMED Medical Systems Co.,Ltd.
Memo

Note !

This instrument can changed no pre-notify for the efficiency and the safety

Purchasing agency : ( )
Manufacturing company : Comed Co,Ltd ( +82-31-764-7321 )
Selling company : ( )
A/S company : ( )

40
COMED Medical Systems Co.,Ltd.