BOD METERS

M
BODT-1, Biological Oxygen Demand, With Integral Incubator
The Quick BODT-1 takes significant steps to do away with the weaknesses of
biosensor BOD measuring apparatus entailed by trouble and time required
to replace and load microbe membrane and with an exchangeable
electrode. Unit that makes it easy to use right away provides improved
operability and maintainability standard and buffer bacteriostatic solutions
and antibacterial tubing allow stable measurements for long terms The
dedicated shipping and recovery box for Used and replacement electrode
units may be reused any number of times and the exclusion of apparatus
environmentally friendly and easy to use .
Model BODT-1
Measurement method Biosensor
BODT-1 Measurable Liquid samples containing soluble organic matter such
as drainage and river water
Features: 0-20 mg/l (base Measurement range)
Exchangeable microbe electrode units Measurement range Variable with pump rpm and sample
make operation smoother and less Contact time
time-consuming than loading and 60 min/specimen
Measurement time (assuming calibration for each specimen)
replacing conventional membranes.
Electrode units may be used for one Calibration Single-point calibration with glucose glutamic solution
month continuously or for three Readout LCD, 20 characters x 2 lines
months intermittently with standard Precision up to 0.1 mg/L
samples. (Electrode units should be Reproducibility Full-scale within 5%
stored in refrigerators when not taking Recorder output (0-5 V analog output)
measurements.) Output Hot output (0-5 V analog output)
Front panel allows simple, pushbutton Printer output (Printy 3 serial thermal printer)
operation. Temperature controller Adjustable within 35C0.2C
Ease of replacement by installing Rated power source AC 100V10V,50/60HZ,3A max
electrode units or tubing into the
opened door in the front panel. Dimensions W370 D350 H300 mm
Anti-reflux valves and antibacterial Weight 14kg
tubing reduce the frequency of Ambient temperature 5-40C
maintenance.
Bacteriostatic is mixed into standard Ambient humidity 90% RH max (Without condensation)
and buffer solutions, so measurements Peripherals Standard solution, buffer solution, antibacterial tubing
are stable over the long term. set, printer
Measurements in regions of low concentration are especially stable.
Changing pump rpm or sample contact time allows measurements in regions of high concentration.
The optional microbe fixation kit enables the use of other microbes and, therefore, a variety of water samples.
Making no use of dangerous reagents and emitting no harmful effluents, the Quick BODT-1 is environmentally friendly.
BODT-5, BOD Tester
Application: Apply to Surface Water, Sewage, Industrial Wastewater in the BOD.
Features:
Display the trend curve
Printer output
Link to the compute through USB interface
Mercury-free devices to ensure the accuracy & safety of the BOD measurement
Real-time clock display
Automatic collection and storage of data
Depict BOD curves for the user to view
Link to the computer to print curves
No parameter and data loss after sudden cut-off
LCD humanization interface display, easy operation
1-30days of the test time, setting by the keys
Store data and update the result, observe the change rate of BOD in the
BODT-5 LCD screen during any testing time, store 240 data points and 20 groups
data of each sample.
Principle of Operation:
The instrument is designed by the Model BODT-5
pressure-difference method, simulating liquid containing soluble organic matter, such as
Measurable drainage and river water
the degradation of natural organic
0-35, 0-70, 0-350, 0-700mg/L (without dilution)
matter. 21% of the oxygen in the air on Range 700-4000 mg/L (need to dilute)
the top of Test Bottle continuously
Sample Quantity 6 Bottle Capacity: 500mL
replenish the dissolved oxygen
consumed in water, carbon dioxide Repeatability 5%
(CO2) produced in the process of 0.1mg/L (0-35, 0-70mg/L)
organic matter degradation is absorbed Resolution 1mg/L (0-350mg/L, 0- 700mg/L)
by Sodium hydroxide coming from sealed Dimension 350400350mm
cap, pressure sensor monitor constantly
Display LED
the pressure change of sample bottle.
There is a correlation between Power Supply AC 220 50Hz
Biochemical oxygen demand BOD (correspond to the consumption of oxygen in the test bottle) & Gas pressure, such
relevance is dealt with by this instrument, direct display of Biochemical oxygen demand BOD value on the screen.