Sei sulla pagina 1di 4

Our Locations

Wausau - North/Corporate Wausau - South


5101 Mesker Street Schofield, WI 54476 1730 County Road XX Rothschild, WI 54474
715-359-3155 t/f: 800-283-8332 fx: 715-355-5931 715-359-4860 t/f: 888-246-1249 fx: 715-359-9450

Sturtevant Appleton
10200 Durand Ave Sturtevant, WI 53177 2820 N Roemer Rd Appleton, WI 54911
262-886-1875 t/f: 800-367-7676 fx: 262-886-9202 920-730-0203 t/f: 800-283-5564 fx: 920-730-0937

Minneapolis Duluth
9300 Evergreen Blvd NW Minneapolis, MN 55433 4413 Venture Ave Duluth, MN 55811
763-780-3234 t/f: 800-290-9320 fx: 763-780-3957 218-729-3375 t/f: 800-943-9549 fx: 218-729-3382

Menominee Hydro Solutions


1100 56th Ave Menominee, MI 49858 1810 County Road XX Rothschild, WI 54474
906-864-2500 t/f: 800-864-2507 fx: 906-864-3672 715-359-0551 t/f: 877-258-5128 fx: 715-355-5948

Visit our website


Dedicated People, Quality
Products, and above all, Service
L&S Electric 2014 CS14 www.lselectric.com
L&S Electric Commissioning Services Relay Commissioning CTS, PTS, CVTS, CCVTS
L&S Electric offers a comprehensive line of electrical Setting installation Insulation resistance
commissioning services to meet your needs, regardless of voltage. Fault interpretation Ratio
Protective element calibration Polarity
Our team of qualified field services engineers are knowledgeable Automated test plan set up Saturation
about all types of power systems and their components. Logic strings tested Burden
Input / Output operation Power factor
Our Power Service Specialists are available 24 hours a day,
Satellite relay testing on multiple lines Dielectric withstand
seven days a week. Primary injection for bus differential Excitation
All protection schemes: differential, breaker Single point ground
Substation Commissioning failure, POTT, block fast trip, etc.
Apparatus testing Relays All apparatus Controls and Functional Tests
Breakers Microprocessor tested
Switch Commissioning Injection of AC circuits
SF6 Solid state Thermography, MODs Verification/operation of DC circuits
Vacuum EM ultrasound, and EODs Testing/operation of all protection schemes
OCB Manually and radio interference Insulation resistance End-to-end line relay testing via satellite
Air breakers electrically Controls Contact resistance Multiple terminal lines
Transformers operated switches Functional testing Power factor Verification/operation of control
GSU Cables Communication Dielectric withstand Verification of RTU, SCADA, and DCS points
Large power CTs, PTs, CVTs, testing Alignment
Station Service CCVTs, and SAs Cam adjustment
Timing VLF / Tan Delta
Breaker Commissioning Comprehensive battery of Definitive baseline test to establish trend
Electrical testing, troubleshooting, and commissioning of electric electrical tests performed on-site IEEE 400.2 Standard
power systems is essential to the safe start up of any electrical sys-
Maximum voltage of 44k Vrms
tem for the first time, regardless of size or industry. Our experienced Thermographic Surveys True sine wave low frequency output
Power Service team provides expertise that will avoid prolonged Sophisticated Equipment Capable of testing 1 microfarad at .01 Hz
delays in the start up which can lead to costly productivity losses. Long wave system, which is less and 60 kV peak
Our technicians perform a variety of other maintenance services susceptible to reflections, allows Recognized power generation market leader
that include insulation and contact resistance, timing, dielectric accurate temperature measurement
in adverse environments
withstand tests, and more.
Measurements from 14 F to 2732 F Partial Discharge Testing
Insulation Power factor Proper operation [-10 C to +1500 C] with 0.1 C accuracy IEEE 400.3 Standard
resistance Minimum pick up of auxiliary devices Scanning distances up to 60 feet Industry standard for validating
Contact resistance tests for coils Comprehensive new installations
Timing SF6 gas work battery of electrical On-Site Report Workmanship defects
Dielectric tests performed Immediate preliminary analysis Signal attenuation is the limitation for all PD
withstand tests on-site Details potentially hazardous problems Testing. Attenuation occurs >5k feet, splices,
Transformer Commissioning joints, etc. increase attenuation
Millivolt signal
Transformer maintenance and proper installation of power trans-
No power limitation
formers is critical for extending the life of your transformer. Our
0 PD is the limit
skilled, experienced technicians install, assemble, and vacuum-fill
6pC or 6000 the test specimen fails
new and rebuilt transformers.
Test technician needs to differentiate
Our technicians perform a variety of other maintenance services between noise and signal
that include oil sampling and testing, oil retrofilling, regasketing,
bushing replacement, radiator replacement, welding repairs, load Cable Commissioning
tap changers, and transformer painting. Formal Thermographic Report Insulation resistance
Complete dress out SFRA Oil analysis Indicates each piece of equipment that Shield continuity
Turns ratio Tap changer Comprehensive has been scanned DC hipot
Insulation controls and set-up battery of electrical Summarizes all problems found and AC hipot
resistance All gauges and tests performed recommends solutions Tan-Delta
Winding resistance peripheral on-site Identifies each problem by equipment name VLF
Excitation devices tested and location, provides a detailed description, Partial discharge
Power factor and states a recommended action for repair
L&S Electric Commissioning Services Relay Commissioning CTS, PTS, CVTS, CCVTS
L&S Electric offers a comprehensive line of electrical Setting installation Insulation resistance
commissioning services to meet your needs, regardless of voltage. Fault interpretation Ratio
Protective element calibration Polarity
Our team of qualified field services engineers are knowledgeable Automated test plan set up Saturation
about all types of power systems and their components. Logic strings tested Burden
Input / Output operation Power factor
Our Power Service Specialists are available 24 hours a day,
Satellite relay testing on multiple lines Dielectric withstand
seven days a week. Primary injection for bus differential Excitation
All protection schemes: differential, breaker Single point ground
Substation Commissioning failure, POTT, block fast trip, etc.
Apparatus testing Relays All apparatus Controls and Functional Tests
Breakers Microprocessor tested
Switch Commissioning Injection of AC circuits
SF6 Solid state Thermography, MODs Verification/operation of DC circuits
Vacuum EM ultrasound, and EODs Testing/operation of all protection schemes
OCB Manually and radio interference Insulation resistance End-to-end line relay testing via satellite
Air breakers electrically Controls Contact resistance Multiple terminal lines
Transformers operated switches Functional testing Power factor Verification/operation of control
GSU Cables Communication Dielectric withstand Verification of RTU, SCADA, and DCS points
Large power CTs, PTs, CVTs, testing Alignment
Station Service CCVTs, and SAs Cam adjustment
Timing VLF / Tan Delta
Breaker Commissioning Comprehensive battery of Definitive baseline test to establish trend
Electrical testing, troubleshooting, and commissioning of electric electrical tests performed on-site IEEE 400.2 Standard
power systems is essential to the safe start up of any electrical sys-
Maximum voltage of 44k Vrms
tem for the first time, regardless of size or industry. Our experienced Thermographic Surveys True sine wave low frequency output
Power Service team provides expertise that will avoid prolonged Sophisticated Equipment Capable of testing 1 microfarad at .01 Hz
delays in the start up which can lead to costly productivity losses. Long wave system, which is less and 60 kV peak
Our technicians perform a variety of other maintenance services susceptible to reflections, allows Recognized power generation market leader
that include insulation and contact resistance, timing, dielectric accurate temperature measurement
in adverse environments
withstand tests, and more.
Measurements from 14 F to 2732 F Partial Discharge Testing
Insulation Power factor Proper operation [-10 C to +1500 C] with 0.1 C accuracy IEEE 400.3 Standard
resistance Minimum pick up of auxiliary devices Scanning distances up to 60 feet Industry standard for validating
Contact resistance tests for coils Comprehensive new installations
Timing SF6 gas work battery of electrical On-Site Report Workmanship defects
Dielectric tests performed Immediate preliminary analysis Signal attenuation is the limitation for all PD
withstand tests on-site Details potentially hazardous problems Testing. Attenuation occurs >5k feet, splices,
Transformer Commissioning joints, etc. increase attenuation
Millivolt signal
Transformer maintenance and proper installation of power trans-
No power limitation
formers is critical for extending the life of your transformer. Our
0 PD is the limit
skilled, experienced technicians install, assemble, and vacuum-fill
6pC or 6000 the test specimen fails
new and rebuilt transformers.
Test technician needs to differentiate
Our technicians perform a variety of other maintenance services between noise and signal
that include oil sampling and testing, oil retrofilling, regasketing,
bushing replacement, radiator replacement, welding repairs, load Cable Commissioning
tap changers, and transformer painting. Formal Thermographic Report Insulation resistance
Complete dress out SFRA Oil analysis Indicates each piece of equipment that Shield continuity
Turns ratio Tap changer Comprehensive has been scanned DC hipot
Insulation controls and set-up battery of electrical Summarizes all problems found and AC hipot
resistance All gauges and tests performed recommends solutions Tan-Delta
Winding resistance peripheral on-site Identifies each problem by equipment name VLF
Excitation devices tested and location, provides a detailed description, Partial discharge
Power factor and states a recommended action for repair
Our Locations

Wausau - North/Corporate Wausau - South


5101 Mesker Street Schofield, WI 54476 1730 County Road XX Rothschild, WI 54474
715-359-3155 t/f: 800-283-8332 fx: 715-355-5931 715-359-4860 t/f: 888-246-1249 fx: 715-359-9450

Sturtevant Appleton
10200 Durand Ave Sturtevant, WI 53177 2820 N Roemer Rd Appleton, WI 54911
262-886-1875 t/f: 800-367-7676 fx: 262-886-9202 920-730-0203 t/f: 800-283-5564 fx: 920-730-0937

Minneapolis Duluth
9300 Evergreen Blvd NW Minneapolis, MN 55433 4413 Venture Ave Duluth, MN 55811
763-780-3234 t/f: 800-290-9320 fx: 763-780-3957 218-729-3375 t/f: 800-943-9549 fx: 218-729-3382

Menominee Hydro Solutions


1100 56th Ave Menominee, MI 49858 1810 County Road XX Rothschild, WI 54474
906-864-2500 t/f: 800-864-2507 fx: 906-864-3672 715-359-0551 t/f: 877-258-5128 fx: 715-355-5948

Visit our website


Dedicated People, Quality
Products, and above all, Service
L&S Electric 2014 CS14 www.lselectric.com

Potrebbero piacerti anche