Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
TECNOLOGIA DE LA
CONCRETO ARMADO II
CONSTRUCCION
ACERO DE REFUERZO
ENCOFRADO
10:09:37 p.m. 1
PREDIMENCIONAMIENTO
CONFIGURACION ESTRUCTURAL SISMO
RESISTENTE
UBICACIN DE LOS EJES DE LOS PORTICOS
UBICACIN Y DIMENSIONAMIENTO DE LAS
COLUMNAS Y PLACAS
DIMENSIONAMIENTO DE LAS VIGAS Y LOSA
EVITAR LAS IRREGULARIDADES ESTRUCTURALES
EN ALTURA
EVITAR PISO BLANDO
IRREGULARIDADES ESTRUCTURALES EN PLANTA
10:09:37 p.m. 2
LOSA ARMADA EN LAS DOS
VIGA DIRECCIONES
10:09:37 p.m. 3
PREDIMENSIONAMIENTO
b
EN COLUMNAS:
T
=
4.41
USO
PARA UNA LOSA
VIVIENDAS
EN VIGAS: ALIGERADA DE 0.20m. 12.47
MULTIFAMILIARES S/C=200
DE ESPESOR
12.06
= = OFICINAS S/C= 250 Kg/m2
4.41 20 GARAJES Y TIENDA S/C =
10.63
h 500 Kg/m2
DEPOSITOS Y BIBLIOTECA
9.6
b S/C= 750 Kg/m2
10:09:37 p.m. 4
10:09:37 p.m. 5
1Mpa<>0.0980665Kgf/cm2
L=28.58 cm
10:09:37 p.m. 7
DOBLECES
10:09:37 p.m. 8
DETALLE DE DOBLECES DEL
ACERO EN ESTRIBOS
10:09:37 p.m. 9
RECUBRIMIENTOS
10:09:37 p.m. 10
DETALLES DE LAS ARMADURAS
10:09:37 p.m. 11
DETALLES DE LAS ARMADURAS
10:09:37 p.m. 12
DETALLES DE LAS ARMADURAS
10:09:37 p.m. 13
DETALLES DE LAS ARMADURAS
10:09:37 p.m. 14
DIAGRAMA DE MOMENTO FLECTOR COMBINACION (D y L)
10:09:37 p.m. 15
DIAGRAMA DE MOMENTO FLECTOR COMBINACION (D y E)
10:09:37 p.m. 16
DIAGRAMA DE MOMENTO FLECTOR - ENVOLVENTE
10:09:37 p.m. 17
AREA DEL ACERO DE REFUERZO LONGITUDINAL
10:09:37 p.m. 18
CARACTERISTICAS GEOMETRICAS Y PESO DE
LAS VARILLAS
DE ACERO DE REFUERZO
DIAMETRO DENOMINACION AREA PERIMERTO PESO NOMINAL % DE
DLI NOMINAL cm2 NOMINAL Kg/m DESPERDICIO
10:09:37 p.m. 19
ANCHO MNIMO Y DISTRIBUCIN DE VARILLAS EN VIGA(cm.)
NMERO DE VARILLAS EN UNA CAPA Incremento
2 3 4 5 6 7 8
por c/cabilla
adicional
10:09:37 p.m. 20
DIAGRAMA DE MOMENTO FLECTOR - ENVOLVENTE
10:09:37 p.m. 21
DIAGRAMA DE FUERZA CORTANTE - ENVOLVENTE
10:09:37 p.m. 22
AREA DEL ACERO DE REFUERZO LONGITUDINAL
10:09:37 p.m. 23
DIAGRAMA DE MOMENTO FLECTOR - ENVOLVENTE
10:09:37 p.m. 24
AREA DEL ACERO DE REFUERZO LONGITUDINAL
10:09:37 p.m. 25
DIAGRAMA DE MOMENTO FLECTOR - ENVOLVENTE
10:09:37 p.m. 26
AREA DEL ACERO DE REFUERZO LONGITUDINAL
10:09:37 p.m. 27
10:09:37 p.m. 28
10:09:37 p.m. 29
EMPALMES
ACERO DE REFUERZO
10:09:37 p.m. 30
ADHERENCIA ENTRE EL ACERO Y EL HORMIGN
Para lograr el funcionamiento integrado del concreto con el acero es
necesario que se generen fuerzas de adherencia en la superficie de
contacto de los 2 materiales.
Son las fuerzas de adherencia el mecanismo bsico de transferencia
de las solicitaciones que actan desde el concreto hacia el acero de
refuerzo, y desde el acero de refuerzo hacia el concreto.
10:09:37 p.m. 31
EMPALME POR TRASLAPE
10:09:37 p.m. 32
EMPALME POR SOLDADURA
10:09:37 p.m. 33
10:09:37 p.m. 34
10:09:37 p.m. 35
10:09:37 p.m. 36
ESPECIFICACIONES
10:09:37 p.m. 38
UNIONES MECANICAS
Las uniones mecnicas de manguitos enroscables, por ltimo, son muy utilizadas en
pases del primer mundo, pero prcticamente no se los emplea en nuestro pas por
su costo elevado. Por tener rosca interior en los 2 extremos que deben unirse,
requieren que las varillas a integrar sean roscadas en los extremos de unin, lo que
se lo puede hacer en obra o se puede adquirir en fbrica
10:09:37 p.m. 39
DETALLE DE LA UBICACION Y LONGITUD
DE EMPALMES TRASLAPADOS PARA COLUMNAS
L/6
2L/3
E1
L
L/6
10:09:37 p.m. 40
DETALLE DE LA UBICACION Y LONGITUD
DE EMPALMES TRASLAPADOS PARA VIGAS
L/3 L/3 L/3
M superior
M inferior
10:09:37 p.m. 41
PAQUETES DE VARILLAS EN VIGAS
10:09:37 p.m. 42
2.5cm.
PAQUETES DE VARILLAS EN VIGAS
5cm. Mnimo
5cm. Mnimo
7cm. Mnimo
2.5cm. Mnimo
10:09:37 p.m. 43
ESPECIFICACIONES:
10:09:37 p.m. 44
PROCESO CONSTRUCTIVO
10:09:37 p.m. 45
DESCARGA DE LAS BARRAS DE ACERO
10:09:37 p.m. 46
ALMACENAMIENTO DEL FIERRO DE CONSTRUCCION
10:09:37 p.m. 47
PROCEDIMIENTO CONSTRUCTIVO DEL ACERO DE
REFUERZO
ARMADO
HABILITADO MONTAJE
10:09:37 p.m. 48
HABILITADO
10:09:37 p.m. 49
HABILITADO
10:09:37 p.m. 51
HABILITADO - ARMADO
10:09:37 p.m. 52
ERROR FRECUENTE
10:09:37 p.m. 53
10:09:37 p.m. 54
POCO RECUBRIMIENTO
10:09:37 p.m. 55
ARMADO DEL ACERO DE REFUERZO PARA COLUMNAS
10:09:37 p.m. 56
ARMADO DEL ACERO DE REFUERZO PARA COLUMNAS
10:09:37 p.m. 57
MONTAJE
10:09:37 p.m. 58
MONTAJE
10:09:37 p.m. 59
ARMADO DEL ACERO DE REFUERZO DE COLUMNAS, PLACAS, MUROS EN EL
LUGAR DONDE SE INDICA EN LOS PLANOS DE CIMENTACION.
10:09:37 p.m. 60
DISTRIBUCION DEL ACERO DE REFUERZO EN MUROS
10:09:37 p.m. 61
DISTRIBUCION DEL ACERO DE REFUERZO EN VIGA DE CIMENTACION
10:09:37 p.m. 62
LOS FIERROS QUE ESTAN PARCIALMENTE DENTRO DEL CONCRETO NO DEBERAN
DOBLARSE.
LAS VARILLAS QUE HAN SIDO DOBLADOS NO PODRAN SER ENDEREZADOS, NI
DEBERAN VOLVERSE A DOBLAR.
10:09:37 p.m. 63
CONCLUSIONES
EN LOS PLANOS DE CONSTRUCCION DEBEN ESTAR INDICADOS LOS DETALLES DE FORMA
CLARA Y PRECISA.
DEBE VERIFICARSE QUE EL CORTADO Y DOBLES DEL ACERO DEBE ESTAR DE ACUERDO A
LO INDICADO EN EL DETALLES CONSTRUCTIVOS MOSTRADO EN LOS PLANOS.
DEBE VERIFICARSE LA DISTRIBUCION DE LOS ESTRIBOS Y EL RECUBRIMIENTO DE
ACUERDO A LO INDICADO EN LOS PLANOS.
LOS TRABAJOS DE HABILITADO Y DOBLECES DEBEN HACERSE CON LOS EQUIPOS Y
HERRAMIENTAS ADECUADAS.
EN LOS TRABAJOS DEL ACERO DE REFUERZO, SIEMPRE SE TENDRA ENCUENTA LA
SEGURIDAD.
CUANDO SE VA A COLOCAR EL CONCRETO EN LOS ELEMENTOS QUE TIENEN
ARMADURAS, ESTAS DEBEN REVISARSE A FIN DE QUE NO TENGAN RESIDUOS QUE
EMPIDAN LA ADHERENCIA DEL CONCRETO Y EL ACERO.
EL ACERO EN LA INTEMPERIE SE OXIDA, Y ESTOS DEBERAN LIMPIERSE CON ESCOBILLA DE
ACERO TAL QUE SE ELIMINE EL TOTAL DE OXIDOS A FIN DE LOGRAR LA ADHERENCIA
ENTRE EL CONCRETO Y EL ACERO.
10:09:37 p.m. 64
QUE PASA CUANDO NOS OLVIDAMOS
DE LAS CONSIDERACIONES DEL
DISEO
10:09:37 p.m. 65
RAJADURAS POR AUSENCIA DE ACERO MINIMO Y CALIDAD DEL CONCRETO
10:09:37 p.m. 66
* MALA UBICACIN DE LA JUNTA SISMICA.
* ESPESOR DE LA JUNTA INAPROPIADA.
10:09:37 p.m. 67
1
10:09:37 p.m. 68
* INADECUADA PROPORCION ENTRE EL ANCHO Y LARGO DEL EDIFICIO
* PROBLEMA DE EXCENTRICIDAD GENERA MOMENTOS DE TORSIN
10:09:37 p.m. 69
10:09:37 p.m. 70
ZONA DE CONFINAMIENTO SIN ESTRIBOS
10:09:37 p.m. 71
FALLA POR CORTE
10:09:37 p.m. 72
FALLA POR COLUMNA CORTA
10:09:37 p.m. 73
EL REFUERZO DE LA COLUMNA NO FUNCIONO
10:09:37 p.m. 74
RECUBRIMIENTO INADECUADO Y
FALTA DE PROTECCION
10:09:37 p.m. 75
* CONCRETO Fc=210 kg/m2; CEMENTO PORTLAD TIPO I; MATERIALES
INADECUADO
* FALTA DE PROTECCION ADECUADA A LAS COLUMNAS
* RECUBRIMIENTO INADECUADO.
10:09:37 p.m. 76
REFORZAMIENTO DEL ESTRIBO
10:09:37 p.m. 77
EL ACERO HORIZONTAL NO GUARDA
PROPORCION CON EL ACERO VERTICAL
10:09:37 p.m. 78
RECOMENDACION
REVISAR EN VARIAS OPORTUNIDADES LOS
PLANOS DE DISEO.
SOLICITAR QUE SE ELABORE LOS DETALLES
CONSTRUCTIVOS.
REVISAR LA MEMORIA DE CALCULO.
LAS MODIFICACIONES QUE SE REALICEN POR
PROCESOS CONSTRUCTIVOS DEBEN SER
CONSULTADAS AL PROYECTISTA.
10:09:37 p.m. 79
10:09:37 p.m. 80