115 Years + of
Innovation
We have been a leader in fire protection since 1898. As a privately held business, Potter is able
to quickly respond and react to our customers needs and provide the individual attention and
service that each of our customers deserve. Potters reputation for quality and service has been
the catalyst towards our focus for the design, development, and manufacture of the highest quality
and most reliable life safety products avalable today.
This is the reason Potter provides an industry leading 5-year warranty on all major products.
With this new line of fire panels and our full complement of modules, detectors, and notification
devices, we begin a new era in the fire alarm industry. As an independent manufacturer with a full
line, we know youll find it easy to do business with us. Give us a call, send us an email, or visit our
website. We look forward to serving you!
A different kind of
fire alarm company.
Addressable Fire Alarm Control Panels P-Link Circuit
10A Power / 320 2 5A Power / 315 2 5A Power / 315 2 3.5A Power / 313.5 2
160 Character LCD 160 Character LCD 32 Character LCD 32 Character LCD
RA-6500 RA-6075 LED-16
160 Character LCD Remote Annunciator 32 Character LCD Remote Annunciator LED Remote Annunciator
(E) - Extra large cabinet for P-Link Remote Booster Panels 1,000 Messages
Expanders
Fire Fighter Telephone Capable
SCI DCM-4 MOM-4 TRM-4 CIZM-4 SCM-4
Short Circuit Isolator Dual Contact Module Monitored Output Twin Relay Module Conventional Initiating Single Contact
Conventional Fire Alarm Control Panels Module Zone Module Module
MCM
Mini Contact Module
1
With the addition of SLCE-127 expansion cards. PFC-6800 supports 7 total cards, PFC-6200 supports 1.
2
Capacity with maximum of 31 PSN-1000(E) Intelligent Power Supplies.
Fire Panel Connections
SLC Loop
P-Link Circuit
Facility
To Central Management Potters Stacker Bracket allows
Station Software for multiple expansion cards to be
placed in a smaller area, multiplying
the capabilities of your system
WAN LAN
P-Link Circuit
Potter / System
NAC Circuit
Amseco Wheelock
Gentex Sensor
IP Connectivity
Communication Options
With todays ever-expanding means of communication, its important to communication allows for event information to be sent to the central
be able to incorporate the same technology into your fire control system. station within seconds. Potters PFC-6000 Series fire alarm control panels are capable of both
We took this technology into account when we designed IP connectivity Potters PFC Series fire panels are NFPA 72 2013, 26.6.3.1.5 compliant IP and phone line communication to central station. The PFC-6006
within our new panels. and allow for a single path of communication over IP. The PFC Series Sprinkler Monitoring Panel complies with new NFPA 72 2013 code by
By eliminating the cost of phone lines, save big when using your line is also factory set to program for NFPA 72 2013 test time interval providing both out of the box.
buildings existing network infrastructure. Additionally, the speed of IP changes of 6 hours from 24 hours.
Reports and the configuration file can be requested from the panel at
any time by sending an email directly to the panel. Additionally, enhance
your business by creating email reminders for your customers to
schedule system tests or even to purchase new batteries.
Communication Over IP
The world of communication in fire alarm is changing. The
installation of POTs lines is being replaced by more reliable and faster
communicating IP connections to monitoring stations.
Panel Programming
The PFC-6000 Series fire panels have the ability to connect to a
Local or Wide Area Network (LAN or WAN) and obtain an IP address.
Once connected, the panel configuration software allows custom
programming and configuration for all points using the network or a
stand-alone computer.
Potter offers a variety of ways to receive training on our full line of fire
Potter provides unmatched education and training opportunities on our industry-leading technology. Training videos are available to be
alarm systems.
full line of fire alarm systems. With multiple ways to receive training, you completed on your time with optional factory certification. Additionally,
choose your preferred method. Webinars on panel hardware, software, live training seminars are provided for advanced training in the PFC To get started, scan the QR code or visit:
and network/communications will bring you up to speed on our series installation and programming.
www.pottersignal.com/training
10A Power / 320 2 5A Power / 315 2 5A Power / 315 2 3.5A Power / 313.5 2
Panel Connections
Facility
4 I/O Circuits 2 I/O Circuits 2 I/O Circuits - To Central Management
NAC Circuit Station Software
160 Character LCD 160 Character LCD 32 Character LCD 32 Character LCD
Intelligent Power Expanders All PFC-6000 Series addressable fire alarm control panels include a built-
in UL Listed sole path IP communicator for communication to primary
central station.
SLC Loop
WAN LAN
1
With the addition of SLCE-127 expansion cards. PFC-6800 supports 7 total IP Connectivity
cards, PFC-6200 supports 1.
2
Capacity with maximum of 31 PSN-1000(E) Intelligent Power Supplies.
PSN-1000(E) PSN-1000
Expansion Enclosures
10A Power 10A Power
Expand your Potter Fire System with the AE-8 and
6 NACs 6 NACs AE-14 expansion enclosures. These accomodate
3A Each NAC 3A Each NAC up to 14 standard size P-Link stacker bracket
expansion cards, boosting the capabilities of your
Intelligent Power Supply Intelligent Power Supply
system.
Extra large cabinet for P-Link -
Expanders AE-14 - 14 Card Enclosure
2 dry contact inputs
AE-8 - 8 Card Enclosure
From 30 addressable points to 1,016, Potters PFC Series line of fire alarm control
panels offer unmatched flexibility.
Short Circuit Isolator Dual Contact Module Monitored Output Module Twin Relay Module
SLC Expandability
With Potters SLCE-127 on the P-Link circuit, your system can be expanded to an
additional 127 addressable points per card. the PFC-6800 fire alarm control panel
supports up to seven SLCE-127 cards for a total addressable point capacity of
1,016. The PFC-6200 fire alarm control panel supports one SLCE-127 cards for a
total addressable point capacity of 254.
CIZM-4 SCM-4 MCM APS-SA/DA
Conventional Initiating Zone Module Single Contact Module Miniature Contact Module Addressable Pull Station
DDA
MHT Series Mini Horns HS/S Series Horns & Strobes FASPKR/SPKSTR Series Speakers & Strobes
NAC Circuits
Wall Mount Devices Ceiling Mount Devices C Series Colored Lens Devices
WP Series Weather Proof Devices PBA/MBA Series Bells Low Frequency Devices
BVL
PFC-6075R PFC-4410RC
From Air Supply Bleeder Valve
75 Addressable Points Conventional Releasing Panel
2 NACs / 190 2 4 Class B Initiating Circuits
5A Power / 315 2 2 Class B Supervisory Circuits
2 I/O Circuits 4 Class B Output Circuits PSA/RHA/FHA DCM-4 PS10-1
32 Character LCD Programmable Cross Zoning Addressable Dual Contact Waterflow Alarm
Smoke/Heat Detector Module
Manual
Releasing Circuit from Panel NAC or I/O
160 Character LCD Remote 32 Character LCD Remote Remote Annunciator for the
Deluge Valve
Annunciator with Releasing Annunciator with Releasing PFC-4410RC Releasing Panel RCDS-1
SLC Loop
Releasing Circuit
Disable Switch
Diagnostic LEDs
Each NAC has an indicator LED which provides two
functions. The primary function is to follow the pattern
NAC Circuits
that its NAC is programmed to output. The secondary
function is to provide trouble indication alerting the
installer as to which NAC is in trouble. This allows for
quick and accurate troubleshooting. Each LED has
trouble memory which can save considerable trouble
shooting time when trying to identify a circuit with an
intermittent problem.
Potter / Gentex Amseco System Sensor Wheelock
Built-in dual line DACT 4 Class B or 2 Class A Zones 8 Class B or 4 Class A Zones 8 Class B or 4 Class A Zones
NFPA 72 2013 Compliance
(Expandable to 8)
Sole Path IP Communicator 4 Class A/B NAC Circuits 4 Class A/B NAC Circuits NFPA 72 2013, 26.6.3.2.1.4 states that a second phone line is no
2 Class A/B NAC Circuits longer an acceptable backup means of communication. The PFC-6006
Email events & service reminders (Expandable to 4) 5 amp Power Supply 5 amp Power Supply
complies with this code with both IP communication and a dual-line
Quadrasync strobe synchronization 5 amp Power Supply Built-in 2-Line Digital Communicator DACT included!
Email Capabilities
Email notification, event history, and even configuration files can be sent
from the panel to 20 separate email addresses! Additionally, enhance
your business by creating email reminders for your customers to
schedule system tests or even to purchase new batteries.
Conventional Fire Panel Conventional Detectors Conventional Bases Conventional Fire Pull Stations
Accessories
Special Application Fire Pull Beam Detectors Conventional Duct Detectors Explosion Proof Devices
Stations
Voice Evacuation
To Fireman
PVC Series PVX Series PVE-802 VAB-802
Phone
High Rise Evacuation System 25-200 watt conventional voice Voice Evacuation Control Panel Audio Booster for PVE-802 Distributed Panel
system
Distributed amplifier panels from Listed for use in low frequency Listed for use in low frequency
25-200 Watts 4-16 speaker circuits expandable 520hz sounder applicatoins 520hz sounder applicatoins
8 speaker circuits per panel Mass notification listed options Includes two 50 Watt amplifiers Includes two 50 Watt amplifiers
Fire fighter phone options available Paging microphone Booster mode provides additional
power/circuits
2 speaker circuits, expandable to 4
with optional splitter Operates as standalone
voice system when live voice
To Fire Alarm
announcements arent required
Control Panel
Master Panel
(1st Floor)
Max SLC Loop Distance 10,000 feet 10,000 feet 10,000 feet 10,000 feet 10,000 feet 10,000 feet
System Sensor/
SLC Protocol Potter /Nohmi
7
Fire-Lite
Hochiki /SK 3
Potter /Nohmi
7
System Sensor
Hochiki
NAC Power Supply (Amps) 5 2.5 6 10 7 6
WASHINGTON
# of NACs 2 Class A, 4 Class B 4 Class B 2 Class A, 4 Class B 6 Class A/B, 4 Class B 2 Class A, 4 Class B 6 Class A/B
5
MONTANA NORTH DAKOTA MAINE 3 amps each,
NAC Circuit Rating 3 amps each 2.5 amp each 3 amp each 3 amps each 3 amps each
I/O 1 amp each
1
MICHIGAN
OREGON VT
MINNESOTA NH On-Board Programmable I/O 2 0 0 4 0 5
IDAHO
SOUTH DAKOTA WISCONSIN NEW YORK MASS E-mailing Capabilities5
Built-In No No Built-In No No
CONN RI
IP Communicator Included Optional Optional Included Optional Optional
3
WYOMING MICHIGAN
4
OKLAHOMA
ARIZONA SOUTH CAROLINA
Auto Programming Yes Yes Yes Yes Yes Yes
2
ARKANSAS
NEW MEXICO
Auto Programming finds/adds/
ALABAMA GEORGIA deletes/device-type changes Yes Finds/Adds Only No Yes Finds/Adds Only No
LOUISIANA
without affecting installed program
MISSISSIPPI
TEXAS Programming Zones 99 99 125 1,500 99 125
Programming Port Cable Standard Ethernet USB Serial or USB Standard Ethernet PS-2 Keyboard Serial Cable
ALASKA
Annunciators 31 32 8 31 8 8
HAWAII FLORIDA
Battery Size in cabinet (x2) 18 18 18 18 18 18
Battery Charging Capability 55 18 35 55 26 35
QUALITY is the first order of business. Since 1898, we have served the fire and security industries
on a worldwide basis. Today, we produce a wide array of products including the most innovative
IP-based fire alarm control systems and monitoring devices. At Potter, we supply our customers
with products that provide real world solutions for their unique needs and strive to provide them
unequaled service and technical support.
Office Hours:
Monday - Friday
8:00 am - 5:00 pm, CST