Product Sheet | Detecon

Standard detectors
General information

Loop detectors and modules


The detector series offers ionisation smoke detectors, optical
smoke detectors, heat detectors and a multisensor detector,
communicating with the FMZ 5000 with a Loop AP module.
The series is supplemented by manual call points, modules,
isolators and other loop nodes.
Every product responds to queries and control commands
from the re alarm panels. It communicates with the re
alarm panel about the status, type and position as well as
external commands and other information contributing to the
alarm status. The signals are also checked for errors.
A some detectors ve different operating modes are
available which can be selected via the re alarm panel.
Each operating mode has specic response behaviour which
corresponds to the re criteria to be expected.

Conventional detectors
Conventional detectors with a wide range of supply voltages.

The interactive loop detectors dene a new standard in reliable re detection. Highly developed software algorithms and
strongly expanded functionalities set new standards. Fire characteristics are selected in such a way that a re will be safely
detected.
The various options for the individual adjustment of the detector sensitivity and several setup modes dependent on the time of
day guarantee the optimum detector adjustment to the area being monitored.

With these performance characteristics all safety concepts can be implemented and ensure maximum customer benet:
- Five detector sensitivity stages/algorithms for each application (for the standard loop detectors)
- Detector sensitivity that can be switched according to environmental conditions depending on the time of day (for the standard
loop detectors)
- Automatic drift compensation of the measuring system for constant sensitivity over the whole period of application
- Automatic contamination detection and early maintenance indication for the efcient deployment of maintenance personnel
- Automatic function monitoring including sensor technology for greatest availability
- Safe operation due to emergency running characteristics during a potential processor failure
- Non-volatile memory, e.g. date of commissioning, last service, reference number, value of the drift compensation

A variety of detector installation bases and numerous modules for adding contacts and issuing signals complete this system.
Visual and acoustic signal transmitters can also be switched directly on the loop to issue alarms.
P31.311.000en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 1
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, addressable

Optical smoke detector OMX95 Order no.: 907541


Analog addressable optical smoke detector. Designed for
use in areas where only low false alarm sources can be
expected.
Applicable for operation in re alarm panels FMZ 5000 with
Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.

Product features Not included in delivery


Constant function monitoring of the sensors, software Detector base see accessories
and hardware including the microcontroller. Address card 901297
Non-volatile memory for detector data.
Day/night switching via re alarm panel with different Connection / mounting
sensitivities. Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Technical specifications Electrostatic shielding not required
Detection method Infrared photo diode
Sensitivity modes
Technology / protocol Loop AP / Discovery
smoke tmin alarm
Integrated isolator no
1 1.4 % / m (39.4 inch) 5s
Operating voltage 17 V - 28 V DC
2 1.4 % / m (39.4 inch) 30 s
Quiescent current 0.65 mA
3 2.1 % / m (39.4 inch) 5s
Alarm current 3.4 mA
4 2.1 % / m (39.4 inch) 30 s
Alarm indication 2 red LEDs
5 2.8 % / m (39.4 inch) 5s
Operating temperature -20 C to +60 C (-4 F to 140 F)
IP rating (EN 60529) IP 43
Enclosure material White polycarbonate
Notes
The response sensitivity must be adjusted to the environmental
Relative humidity 0 to 95%
conditions. The settings can be changed at any time.
(IEC721-3-3) no condensation
Specication according to EN 54 Part 7
Weight 105 g (0.2 lbs)
100 x 42 mm (dia. x H)
Dimensions
3.9 x 1.7 inch (dia.xH)

Approvals / marking

G 208033 0832-CPD-0024
P31.311.120en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 2
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, addressable

Ionisation smoke detector IMX95 Order no.: 907544


Analog addressable ionisation smoke detector. Designed for
use in areas where occasional dust can be expected.
Applicable for operation in re alarm panels FMZ 5000 with
Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.

Product features Not included in delivery


Constant function monitoring of the sensors, software Detector base see accessories
and hardware including the microcontroller. Address card 901297
Non-volatile memory for detector data.
Day/night switching via re alarm panel with different Connection / mounting
sensitivities. Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Technical specifications
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Detection method Ionisation chamber Electrostatic shielding not required
Technology / protocol Loop AP / Discovery
Integrated isolator no Sensitivity modes
Radioactive isotope Americium 241 tmin alarm
Radioactivity 33.3 kBq 1 y = 0.45 5s
Air velocity Max. 10 m/s (394 inch) 2 y = 0.45 30 s
equivalent to 600 m (0.37 miles) 3 y = 0.70 5s
Atmospheric pressure
above MSL max.
Operating voltage 17 V - 28 V DC 4 y = 0.70 30 s

Quiescent current 0.5 mA 5 y = 1.00 5s

Alarm current 3.5 mA


Note
Alarm indication 2 red LEDs
The response sensitivity must be adjusted to the
Operating temperature -20 C to +60 C (-4F to +140 F) environmental conditions. The settings can be changed at
IP rating (EN 60529) IP 43 any time.
Enclosure material White polycarbonate The detector contains radioactive materials. The operating
instructions and current laws and relating to radiation
Relative humidity 0 to 95%
(IEC721-3-3) no condensation protection must be observed.
Specication according to EN 54 Part 7
Weight 105 g (0.2 lbs)
100 x 42 mm (dia. x H)
Dimensions
3.9 x 1.7 inch (DxH)
P31.311.160en / 01.14

Approvals / marking

G 208036 0832-CPD-0023

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 3
Product Sheet | Detecon

Standard detectors
Multisensor detectors, addressable

Multisensor detector OWMX95 Order no.: 907543


Analog addressable multisensor detector consisting of
a combination of an optical smoke detector and a heat
detector. Designed for use in areas where regular false alarm
sources can be expected.
Intended for operation in re alarm panels FMZ 5000 with
Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.

Product features Optional accessories


Constant function monitoring of the sensors, software Detector remote indicator MPX 070 905568
and hardware including the microcontroller.
Non-volatile memory for detector data. Not included in delivery
Day/night switching via re alarm panel with different Detector base see accessories
sensitivities. Address card 901297

Technical specifications Connection / mounting


Connection cable 2-lead
Smoke detection method Infrared photo diode Recommended cable, standard 747180
Heat detection method NTC temperature sensor J-Y(ST)Y-2x2x0.8 mm
Technology / protocol Loop AP / Discovery Conductor cross-section Max. 2.5 mm2 (0.004 square inch)
Integrated isolator no
Electrostatic shielding not required

Operating voltage 17 V - 28 V DC
Sensitivity modes
Quiescent current 0.75 mA
Alarm current 3.5 mA
Smoke Heat Trigger type tminAlarm
1 1.1 % / m high Multisensor 20 s
Alarm indication 2 red LEDs
(39 inch)
-20 C to +60 C
Operating temperature 2 2.1 % / m no trigger Optical 30 s
(-4 F to +140 F)
IP rating (EN 60529) IP 43 (39 inch)
Enclosure material White polycarbonate 3 2.8 % / m low Multisensor 20 s
Relative humidity 0 to 95% (39 inch)
(IEC721-3-3) no condensation 4 4.2 % / m high Multisensor 20 s
Specication according to EN 54 part 5 and 7 (39 inch)
Weight 105 g (0.2 lbs) 5 no trigger A1 class A1 30 s
100 x 50 mm (dia. x H) heat detector
Dimensions
3.9 x 2 inch (dia.xH)

Notes
Approvals / marking The response sensitivity must be adjusted to the ambient
conditions. The settings can be changed at any time.
G 208034 0832-CPD-0025
When using the detector in mode 5 the number of max.
P31.311.520en / 01.14

permitted monitoring areas for heat detectors must not be


exceeded.

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 4
Product Sheet | Detecon

Standard detectors
Heat detectors, addressable

Heat detector WMX95 Order no.: 907542


Analog addressable rate-of-rise and maximum heat detector
for use in areas where interference variables like smoke can
be expected (e.g. ofce/storage areas, industrial plants or
test stands).
Applicable for operation in re alarm panels FMZ 5000 with
Loop AP protocol.
3 response classes in accordance with EN54-5 and
2 temperature ranges adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.

Product features Optional accessories


Constant function monitoring of the sensors, software Parallel indicator LMX5000 908499
and hardware including the microcontroller.
Non-volatile memory for detector data. Not included in delivery
Day/night switching via re alarm panel with different Detector base see accessories
sensitivities. Address card 901297

Technical specifications Connection / mounting


Connection cable 2-lead
Detection method NTC temperature sensor
Recommended cable, standard 747180
Technology / protocol Loop AP / Discovery
J-Y(ST)Y-2x2x0.8 mm
Integrated isolator no Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Response classes A1R, A2, A2S Electrostatic shielding not required
Temperature ranges CR, CS
Operating voltage 17 V - 28 V DC Sensitivity modes
Quiescent current 0.5 mA class temperature
Alarm current 3.4 mA 1 A1R 54 C (129 F) to 65 C (149 F)
Alarm indication 2 red LEDs 2 A2 54 C (129 F) to 70 C (158 F)
+54 C to +100 C 3 A2S 54 C (129 F) to 70 C (158 F)
Response temperature
(+129.2 F to +212 F)
-20 C to +80 C 4 CR 84 C (129 F) to 100 C (212 F)
Operating temperature
(-4 F to +176 F) 5 CS 84 C (129 F) to 100 C (212 F)
IP rating (EN 60529) IP 53
Enclosure material White polycarbonate Notes
Relative humidity 0 to 95%
The response sensitivity must be adjusted to the environmental
(IEC721-3-3) no condensation
conditions. The settings can be changed at any time.
Specication according to EN 54 Part 5
Weight 105 g (0.2 lbs)
100 x 42 mm (dia. x H)
Dimensions
3.9 x 1.7 inch (DxH)

Approvals / marking
P31.311.220en / 01.14

G 208035 0832-CPD-0022

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 5
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable
Detector base BAX 210 Order no.: 901289

Base for all Loop AP detectors including address card with


large-size contact screws for all connections. Easy assembly
and simple insertion of the detectors by clockwise rotation
and catch. A connection for a detector remote indicator is
available.

Included in delivery
1 Detector base in standard design including address cards 1
to 126.

Not included in delivery


Mounting hardware
Technical specifications
Material PC
Integrated isolator no
Approvals / marking
IP rating (EN60529) IP 43
Colour White
-20 C to +70 C
Ambient temperature
(-4 F to +158 F)
Weight 55 g (0.1 lbs)
100 x 8 mm (dia. x H)
Dimensions
3.9 x 0.3 inch (dia. x H)

Detector base BAX 284 I Order no.: 910790

Base for all Loop AP detectors including address card


with dual isolator and large-size contact screws for all
connections. For the separation of individual line sections in
the event of short circuits in loop operation. Easy assembly
and simple insertion of the detectors by clockwise rotation
and catch. A connection for a detector remote indicator is
available.

Included in delivery
1 Detector base in standard design including address cards 1
to 126.

Technical specifications Not included in delivery


Material PC Mounting hardware
Integrated isolator yes
Fault indication Yellow LED
Approvals / marking
IP rating (EN60529) IP 43
Colour White G 210033 0832-CPD-1011
-20 C to +60 C
Ambient temperature
(-4 F to +140 F)
P31.311.720en / 01.14

Weight 100 g (0.2 lbs)


100 x 24 mm (dia. x H)
Dimensions
3.9 x 0.9 inch (dia. x H)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 6
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable
Isolator base BAX 211 Order no.: 901294

Base for the ISX 720 I isolator with large-size contact screws
for all connections. Easy assembly and simple insertion of
the isolator by clockwise rotation and lock.

Included in delivery
1 Isolator base in standard design.

Not included in delivery


Mounting hardware
Isolator ISX 720 901293

Technical specifications
Material PC Approvals / marking
IP rating (EN60529) IP 43
Colour White
-20 C to +60 C
Ambient temperature
(-4 F to +140 F)
Weight 55 g (0.2 lbs)
100 x 23 mm (dia. x H)
Dimensions
3.9 x 0.9 inch (dia. x H)

Isolator ISX 720 I Order no.: 901293

Loop AP isolator for the separation of individual line sections


in the event of short circuits in loop operation. Easy assembly
and simple insertion of the isolator in the matching base by
means of clockwise rotation and lock.

Included in delivery
1 isolator for use in isolator base BAX 211.

Approvals / marking

G 200083 0832-CPD-0843
Technical specifications
Material PC
Fault indication Yellow LED
IP rating (EN60529) IP 43
Colour White
-20 C to +60 C
Ambient temperature
(-4 F to +140 F)
Weight 75 g (0.2 lbs)
P31.311.720en / 01.14

100 x 25 mm (dia. x H)
Dimensions
3.9 x 1 inch(dia. x H)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 7
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable

Isolator ISX 284 R Order no.: 914137

Loop AP isolator for the separation of individual line sections


in the event of short circuits in Loop operation. Easy assem-
bly for mounting on a mounting rail.

Included in delivery
1 isolator for mounting on a mounting rail

Approvals / marking

Technical specifications
Fault indication Yellow LED
- 20 C to + 60 C
Ambient temperatur
(-4 F to +140 F)
Weight 20 g
Dimensions 63 x 38.8 x 43 mm (BxHxT)

Bypass detector BMX1001 AP Order no.: 908689

The BMX1001 bypass box for the accomodation of an ana-


logue addressable optical smoke detector OMX95 to monitor
exhaust air and air conditioning ducts with higher air speeds.

Not included in delivery


Optical smoke detector OMX95 907541
Loctite AVK 586, bottle 50 ml 886226
Assembly tool for rivet nuts

Connection / mounting
Recommended cable J-Y (St) Y 2x2x0.8 mm, red
Technical specifications
Air ow
1 m (39 inch)/s to max. Note
20 m (787 inch)/s VdS approval only for bypass box with optical smoke detector
Detector slot 1 Detector base BAX 284-I OMX95.
Pipe for bypass detector
2 threaded pipes DN15 galvanized, Approval for the control of re damper does not exist.
540 mm
Enclosure material Aluminium diecast, grey
-20 C to +60 C
Ambient temperature
(-4 F to +140 F) Approvals / marking
IP rating IP 23
G 28406
Weight with 2 pipes 3500 g (7.7 lbs)
130 x 165 x 95 mm (BxHxT)
Dimensions
5.1 x 6.5 x 3.7 inch (BxHxT)
P31.311.720en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 8
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable

Isolator XP95 IP65, complete Order no.: 905702

Isolator for the separation of individual line sections during


short circuit in loop AP in robust design.
Easy assembly and simple insertion of the isolator with base
in the additional enclosure for industrial applications.

Included in delivery
1 Abox 100 905711
1 mounting plate, complete 908422
Technical specifications 1 Isolator ISX 720 901293
1 Isolator base BAX 211 901294
Material PC
IP rating (EN60529) IP 65 Not included in delivery
Colour of lower enclosure section grey Mounting hardware
Colour of upper enclosure section red
-20 C to +60 C
Ambient temperature
(-4 F to +140 F)
Weight 340 g (0.8 lbs)
140 x 140 x 70 mm (WxHxD)
Dimensions
5.5 x 5.5 x 2.8 inch (WxHxD)

Addressing card ACX 771 Order no.: 901297

Address cards for detectors type XP and DIS, unlabelled,


100 pcs per packaging unit.

Approvals / marking
P31.311.720en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 9
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, addressable, Ex

OMX95 Ex Order no.: 901318


Analog addressable optical smoke detector for Ex zone 0
designed for use in hazard areas where only low false alarm
sources can be expected.
Provided for operation on re alarm control panels FMZ 5000
with Loop AP protocol.
Addressing by means of separate address card. The address
can also be changed after installation.
Detector with intrinsically safe electronics for operation in
areas hazard.
Connection only via a safety barrier Ex Loop AP 24 V.

Product features Not included in delivery


Constant function monitoring of the sensors, software Detector base see accessories
and hardware including the microcontroller. Address card 901297
Safety barrier Ex Loop AP 24 V 901324
Detector for use in zone 0. Protokollinterface Loop AP 901322

Technical specifications Connection / mounting


Detection method Infrared photo diode Connection cable 2-lead
Recommended cable 747180
Technology / protocol Loop AP / XP95
J-Y(ST)Y-2x2x0.8 mm
Integrated isolator no Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Operating voltage 14 V - 22 V DC
Electrostatic shielding not required

Quiescent current 0.34 mA


Note
Alarm current 3.4 mA
-20 C to + 60 C Analog addressable detectors for hazard areas are to be
Operating temperature, T4 connected to the stub line of Loop AP. The protocol interface
(-4 F to +140 F)
-20 C to +45 C and the safety barrier Ex Loop AP have to be used.
Operating temperature, T5
(-4 F to +113 F)
IP rating (EN 60529) IP 43
Enclosure material White polycarbonate
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication to EN 54 part 7
Weight 105 g (0.2 lbs)
100 x 42 mm (DxH)
Dimensions
3.9 x 1.7 inch (DxH)

Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20C Ta +45C)
x II 1G Ex ia IIC T4 Ga (-20C Ta +60C)

EC type approval certicate: BAS 02 ATEX 1289


P31.311.130-2en / 01.14

Ex conformity Russia in acc. with TP TC 012/2011:


0Ex ia IIC T5/T4 Ga

0832-CPD-0313

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 10
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, addressable, Ex

IMX95 Ex Order no.: 901317


Analog addressable ionisation smoke detector for Ex zone 0
designed for use in areas where occasionally low dust levels
are encountered.
Provided for use on FMZ 5000 re alarm control panels with
Loop AP protocol.
Addressing via separate address card. The address can also
be changed after installation.
Detector with intrinsically safe electronics for operation in
hazard areas.
Connection only via an Ex Loop AP 24 V safety barrier.

Product features Not included in delivery


Constant monitoring of sensors, soft- and hardware inclu- Detector base see accessories
sive of microcontroller. Address card 901297
Safety barrier Ex standard 901324
Non-volatile memory for detector data. Loop AP protocol interface 901322
Day/night switchover via control panel with differing sen-
sitivities.
Connection / mounting
Detector for use in zone 0.
Connection cable 2-lead
Recommended cable, standard 747180
Technical specifications J-Y(ST)Y-2x2x0.8 mm
Detection method ionization chamber Conducter cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding not required
Technology / protocol Loop AP / XP95
Integrated isolator no
Note
Radioactive isotope Americium 241
Analog addressable detectors for hazard areas may be used
Radioactivity 33.3 kBq
used in the Loop AP branch. To archive this conguration the
Air speeds max. 10 m (394 inch)/s protocol interface and Ex Loop AP safety barrier have to be
corresponding to max. 600 m used.
Atmospheric pressure
(0.37 miles) a.s.l.
Operating voltage 14 V - 22 V DC Approvals / marking
Quiescent current 0.3 mA Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20C Ta +45C)
Alarm indication 1 LED red
x II 1G Ex ia IIC T4 Ga (-20C Ta +60C)
Operating temperature, T4 -20 C to +60 C (-4 F to +140 F)
Operating temperature, T5 -20 C to +45 C (-4 F to +113 F) EC type approval certicate: BAS 02 ATEX 1289
Ex conformity Russia in acc. with TP TC 012/2011:
IP rating (EN 60529) IP 43
0Ex ia IIC T5/T4 Ga
Enclosure material White polycarbonate
Relative humidity 0 to 95% 0832-CPD-0312
(IEC721-3-3) no condensation
Specication according to EN 54 Part 7
Weight 105 g (0.2 lbs)
100 x 42 mm (DxH)
Dimensions
3.9 x 1.7 inch (DxH)
P31.311.180-2en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 11
Product Sheet | Detecon

Standard detectors
Heat detectors, addressable, Ex

WMX95 Ex Order no.: 901319


Analog addressable maximum differential heat detector for
Ex zone 0 for use in areas in which interferance such as
smoke are likely to be encountered (e.g. ofce- and storage
areas, industrial plant or test facilities).
Provided for use on FMZ 5000 re alarm control panels with
Loop AP protocol.
Addressing via separate address card. The address can also
be changed after installation.
Detector with intrinsically safe electronics for operation in
areas hazard.
Connection only via an Ex Loop AP 24 V safety barrier.

Product fearures Not included in delivery


Constant monitoring of sensors, soft- and hardware inclu- Detector base see accessories
sive of microcontroller. Address card 901297
Safety barrier Ex standard 901324
Detector for use in Zone 0. Loop AP protocol interface 901322

Technical specifications Connection / mounting


Detection method NTC- temperature sensor Connection cable 2-lead
Recommended cable, standard 747180
Technology / protocol Loop AP / XP95
J-Y(ST)Y-2x2x0.8 mm
Integrated isolator no Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Operating voltage 14 V - 22 V DC Electrostatic shielding not required

Quiescent current 0.3 mA


Note
Alarm indication 1 LED red
Analog addressable detectors for hazard areas are to be
Activating temperature approx. +60 C (+140 F)
used in the Loop AP branch. For this purpose the protocol
-20 C to +60 C
Operating temperature, T4 interface and Ex Loop AP safety barrier have to be used.
(-4 F to +140 F)
-20 C to +45 C
Operating temperature, T5
(-4 F to +113 F)
IP rating (EN 60529) IP 53
Enclosure material White polycarbonate
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to EN 54 Part 5
Weight 105 g (0.2 lbs)
100 x 42 mm (DxH)
Dimensions
3.9 x 1.7 inch (DxH)

Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20C Ta +45C)
x II 1G Ex ia IIC T4 Ga (-20C Ta +60C)
P31.311.230 - 2en / 01.14

EC type approval certicate: BAS 02 ATEX 1289


Ex conformity Russia in acc. with TP TC 012/2011:
0Ex ia IIC T5/T4 Ga

0832-CPD-0311

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 12
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable, Ex
Detector base BAX 215 Ex Order no.: 901320

Base for all analog addressable Ex-detectors inc. address


card with large size contact screws for all connections. Simp-
le mounting and easy insertion of detectors by clockwork
rotation with subsequent locking. Plug-in a detector remote
indicator is available.
Base for use in areas with a risk of explosion.
Connection only via an Ex Loop AP 24 V Ex security barrier.

Included in delivery
1 detector socket in the standard version inc. address card
from 1 to 126.

Technical specifications
Material PC
Not included in delivery
Mounting materials
Integrated isolator no
IP rating (EN60529) IP 43
Colour white Approvals / marking
-20 C to +60 C Ex conformity in acc. with 94/9/EG
Operating temperature, T4
(-4 F to +140 F) x II 1G Ex ia IIC T5 Ga (-20C Ta +45C)
-20 C to + 45 C
Operating temperature, T5 x II 1G Ex ia IIC T4 Ga (-20C Ta +60C)
(-4 F to +113 F)
Weight 55 g (0.1 lbs)
EC type approval certicate: BAS 02 ATEX 1289
100 x 8 mm (DxH)
Dimensions
3.9 x 0.3 inch (DxH)
P31.311.730 - 1en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 13
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, conventional

OMX 1001C Order no.: 800831


Conventional optical smoke detector. Designed for use in
areas with smoke in case of re.
Smoke detector with drift compensation fore use in industrial
environments.

Product features Not included in delivery


Constant function monitoring of sensors, software and Detector base see accessories
hardware including the microcontroller. End of line-resistor 1.8 K / 0.5 W 675235
Dust cover 894760
Normal operation indication by green ashing light.
Automatic drift compensation.
Spare parts
Robust smoke detector
Insert OMX (Can) 801023
Basket IMX (Dust-proof grid) 253250
Technical specifications
Detection method Infrared photo diode Connection / mounting
Alarm threshold Connection cable standard detector 2-lead
approx. 0.16 dB/m (39 inch)
(light obscuration)
External Indication 1-lead
Technology conventional Max. Line length max. 700 m at 0.8 mm
Operating voltage 7.6 V - 13.2 V DC (max 0.43 miles at 0.03 inch)
Recommended cable JY (St) Y 2x2x0.8 mm
Quiescent current approx. 0.13 mA
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Alarm current approx. 18 mA
Alarm indication 1 LED red, permanent light Approvals / marking
Normal operation indication 1 LED green, ashing light
Electrostatic shielding existing G 200005 0786-CPD-20131

Operating temperature -20 C to +60 C (-4 F to +140 F)


IP rating (EN 60529) IP 43
Enclosure material white polycarbonate
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Weight 220 g (0.5 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
P31.311.110 - 2en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 14
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, conventional

IMX 1001E Order no.: 754450


Conventional ionisation smoke detector. Designed for use in
areas with smoke in case of re.
Robust smoke detector with a dual ionisation chamber for
use in industrial environments.

Product features Not included in delivery


Drift compensation by dual ionization. Detector base see accessories
End of line-resistor 1.8 K / 0.5 W 675235
Robust smoke detector.
Dust cover 894760

Technical specifications
Connection / mounting
Detection method double ionization chamber Connection cable standard detector 2-lead
Technology conventional
External Indication 1-lead
Recommended cable JY (St) Y 2x2x0.8 mm
Operating voltage 7.6 V - 13.2 V DC Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Quiescent current approx. 0.08 mA
Alarm current approx. 20 mA Notes
Alarm indication 1 LED red The detector contains radioactive materials. The operating
Sensitivity y = 0.8
instructions and current laws and regulations on radiation
protection must be observed.
Air ow max. 5 m/s
Radioactivity Am241 2.8 kBq
Approvals / marking
Electrostatic shielding existing
-20 C up to +60 C G 28107 0786-CPD-20211
Operating temperature
(-4 F to +140 F)
IP 43, with membrane plug and
IP rating (EN 60529)
sealing of the mounting holes
Enclosure material Polycarbonate white
Relative humidity max. 95%
(IEC721-3-3) Avoid condensation
Weight 230 g (0.5 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
P31.311.150en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 15
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional
WMX 1000D60 Order no.: 747866
Conventional combined differential and static head detector.
Designed for areas with rapid rise of temperature caused by
ames.
Heat detector with 2 temperature sensors for use in industrial
environments.

Product features Not included in delivery


Adaptation to ambient temperature by 2 temperature Detector base see accessories
sensors. End of line-resistor 1.8 K / 0.5 W 675235
Dust cover 894760
Combined differential and static measurement.
Robust heat detector.
Connection / mounting
Connection cable standard detector 2-lead
External Indication 1-lead
Technical specifications Recommended cable JY (St) Y 2x2x0.8 mm
Detection method NTC - Temperaturesensor
Conductor cross-section max. 2.5 mm2 (0.004 square inch)

Technology conventional
Operating voltage 7.6 V - 13.2 V DC
Approvals / marking
Quiescent current approx. 0.07 mA G 27611 0786-CPD-20208
Alarm current approx. 15 mA
Alarm indication 1 LED red
Temperature class, rate of Class A1,
rise measurement acc. to EN54-5: 2000 / A1:2002
+54 C to +62 C
Static threshold value
(+129.2 F to +143.9 F)
Electrostatic shielding not required
-20 C to +50 C
Operating temperature
(-4 F to +122 F)
IP 23, with membrane plug and
IP rating (EN 60529)
sealing of the mounting holes
Enclousure material white polycarbonate
Relative humidity max. 95%
(IEC721-3-3) no condensation
Weight 140 g (0.3 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
P31.311.210 - 1en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 16
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional

WMX1000D90 Order no.: 747878

Technical specifications Approvals / marking


Temperature class, rate of Class C,
rise measurement acc. to EN54-5: 2000 / A1:2002 G 29109 0786-CPD-20209
+84 C to +100 C
Static threshold value
(+183.2 F to +212 F)
-20 C to +80 C
Operating temperature
(-4 F to +176 F) Otherwise like Order no. 747866
Weight 140 g (0.3 lbs)
P31.311.210 - 1en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 17
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional
Detector base metric, 3-pin Order no.: 903502

Standard detector base.

Not included in delivery


Membrane plug M16x1.5 (side cable entry) 902313
Membrane plug M20 PE (rear cable entry) 902541
End cap white (side cable entry) 795007
End of line-resistor 1.8 K /0.5 W 675235
Technical specifications Clamping screws

Enclousure material Polycarbonate


Relative humidity max. 100 %
Spare parts
Contact blade 761756
Colour white Terminal 212400
Operating temperature
-40 C to +100 C Cheese-head screw M4x6 DIN84 237829
(-40 F to +212 F ) Serrated lock washer A4,3 DIN6798 606073
Weight 100 g (0.2 lbs)
113 mm (D)
Dimensions
4.5 inch (D)

Detector base metric, 5-pin Order no.: 903503

Detector base with remote indicator.

Not included in delivery


Membrane plug M16x1.5 (side cable entry) 902313
Membrane plug M20 PE (rear cable entry) 902541
End cap white (side cable entry) 795007
End of line-resistor 1.8 K /0.5 W 675235
Technical specifications Card clock module for remote indication 831953
Enclousure material Polycarbonate Clamping screws

Relative humidity max. 100 %


Colour white Spare parts
Contact blade 761756
-40 C to +100 C
Operating temperature Terminal 212400
(-40 F to +212 F)
Cheese-head screw M4x6 DIN84 237829
Weight 100 g (0.2 lbs)
Serrated lock washer A4.3 DIN6798 606073
P31.311.710 - 2en / 01.14

113 mm (D)
Dimensions
4.5 inch (D)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 18
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional

Dust cover for white detectors Order no.: 894760

Protection against pollution of the detector before commissio-


ning.

Included in delivery
1 packaging unit (50 Piece)

Note
Dust cover to be removed with detector servicing tool.
Technical specifications
Enclousure material PVC 0.4 mm (0.01 inch)
Colour orange
Weight 4 g (0.01 lbs)
80.5 x 23 mm (DxH)
Dimensions
3.2 x 0.9 inch (DxH)

Bypass detector BMX1001 Order no.: 719754

The BMX1001 bypass box for the accomodation of an optical


smoke detector OMX1001C to monitor exhaust air and air
conditioning ducts with higher air speeds.

Not included in delivery


Optical smoke detector OMX1001C 800831
Loctite AVK 586, bottle 50 ml 886226
Assembly tool for rivet nuts

Connection / mounting
Recommended cable J-Y (St) Y 2x2x0.8 mm, red
Technical specifications
Air ow
1 m (39 inch)/s to max. Note
20 m (787 inch)/s VdS approval only for bypass box with optical smoke detector
Detector slot 1 Detector base 5-pin OMX1001C.
Pipe for bypass detector
2 threaded pipes DN15 galvanized, An approval for the control of re damper does not exist.
540 mm (21.6 inch)
Enclousure material Aluminium diecast, grey
-20 C to +60 C
Approvals / marking
Ambient temperature
(-4 F to +140 F)
P31.311.710 - 2en / 01.14

IP rating IP 23 G 28406

Weight with 2 pipes 3500 g (7.7 lbs)


130 x 165 x 95 mm (BxHxT)
Dimensions
4.5 x 2.7 inch (DxHxT)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 19
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, conventional

OMX ORB Order no.: 905567


Conventional optical smoke detector for application in areas
where formation of smoke is to be anticipated in case of re.
Smoke detector with special design that uses algorithms for
evaluation, thus achieving high reliability in early re detec-
tion.

Product features Not included in delivery


Permanent function monitoring of the sensors, software Detector base BAX ORB 905564
and hardware by means of a microcontroller. End of line-resister 1.8 K / 0.5 W 675235
Relay socket BAR ORD R 906917
Algorithmic signal evaluation.
Adaptation to the environmental conditions through auto-
matic drift compensation. Connection / mounting
Connection cable 2-lead
Technical specifications External Indication 1-lead
Max. Line length max. 700 m at 0.8 mm
Detection method Infrared photo diode (max 0.43 miles at 0.03 inch)
Technology conventional Recommended cable JY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Operating voltage 8.5 V - 33 V DC
Quiescent current approx. 0.1 mA
Approvals / marking
40 mA at 24 V
Alarm current
20 mA at 12 V
G 204039 0832-CPD-0035
Alarm indication 1 LED red, steady light
-40 C to +70 C
Operating temperature
(-40 F to +158 F)
IP rating (EN 60529) IP 23D
Enclosure material white polycarbonate
Relative humidity 0 to 98%
(IEC721-3-3) no condensation
Weight 75 g (0.2 lbs)
100 x 42 mm (dia.xH)
Dimensions
3.9 x 1.7 inch (dia.xH)
P31.311.110 - 1en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 20
Product Sheet | Detecon

Standard detectors
Multisensor detectors, conventional

Multisensor detector OWMX ORB Order no.: 905566


Conventional multisensor detector consisting of a combinati-
on of optical smoke detector and heat detector. Designed for
the application in areas where periodically occurring sources
of deception are to be anticipated. The multisensor detector
is a thermally supported smoke detector. Its sensitivity is
considerably increased in case of aming res.

Product features Not included in delivery


Permanent function monitoring of the sensors, software Detector base BAX ORB 905564
and hardware including the microcontroller. End of line-resistor 1.8 K / 0.5 W 675235
Relay socket BAX ORB R 906917
Evaluation of the signals with algorithms.
Adaptation to the environmental conditions through auto-
matic drift compensation. Connection / mounting
Connection cable standard detector 2-lead
External indication 1-lead
Technical specifications Recommended cable JY (St) Y 2x2x0.8 mm
Detection method smoke Infrared photo diode Conductor cross-section max. 2.5 mm2 (0.004 square inch)

Detection method heat NTC - Temperatursensor


Technology conventional
Operating voltage 8.5 V - 33 V DC
Quiescent current 0.1 mA
40 mA at 24 V
Alarm current
20 mA at 12 V
Alarm indication 1 LED red
-40 C to +70 C
Operating temperature
(-40 F to +158 F)
IP rating (EN 60529) IP 23D
Enclousure material white polycarbonate
Relative humidity 0 to 98%
(IEC721-3-3) no condensation
Weight 80 g (0.2 lbs)
100 x 50 mm (dia.xH)
Dimensions
(3.9 x 2 inch (dia.xH)

Approvals / marking

G 204040 0832-CPD-0036
P31.311.510en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 21
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional

WMX ORB A1R Order no.: 905565


Conventional heat differential/maximum detector. Designed
for application in areas where rapid development of heat
through ames is to be anticipated.

Product features Not included in delivery


Combined differential/maximum evaluation of the Detector base BAX ORB 905564
increases in temperature. End of line-resistor 1.8 K / 0.5 W 675235
Relay socket BAX ORB R 906917

Technical specifications Connection / mounting


Detection method NTC - Temperaturesensor Connection cable standard detector 2-lead
External indication 1-lead
Technology conventional
Recommended cable JBY (St) Y 2x2x0.8 mm (0.03inch)
Operating voltage 8.5 V - 33 V DC Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Quiescent current approx. 0.1 mA

Alarm current
40 mA at 24 V Approvals / marking
20 mA at 12 V
Alarm indication 1 LED red
G 204033 0832-CPD-0029
Temperature class, Class A1,
rate of rise measurement acc. EN54-5: 2000 / A1:2002
+54 C to +62 C
Statically trip point
(+129.2 F to +143.6 F )
-40 C to +70 C
Operating temperature
(-40 F to +158 F)
IP rating (EN 60529) IP 23 D
Enclousure material white polycarbonate
Relative humidity max. 98%
(IEC721-3-3) no condensation
Weight 70 g (0.2 lbs)
100 x 42 mm (dia.xH)
Dimensions
3.9 x 1.7 inch (dia.xH)
P31.311.210 - 2en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 22
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional
Detector base BAX ORB Order no.: 905564

Standard detector base.

Not included in delivery


Mounting hardware.

Technical specifications Approvals / marking


Enclousure material Polycarbonate
G 204039 0832-CPD-0035
0 to 98 %
Relative humidity
no condensation
Colour white
-40 C to +70 C
Operating temperature
(-40 F to +158 F)
Weight 60 g (0.1 lbs)
100 mm (D)
Dimensions
3.9 inch (D)

Relay base BAX ORB R Order no.: 906917

Standard detector base with relay.

Not included in delivery


mounting hardware.

Technical specifications Approvals / marking


Enclousure material Polycarbonate
G 204039 0832-CPD-0035
0 to 98 %
Relative humidity
no condensation
Colour white
-40 C to +70 C
Operating temperature
(-40 F to +158 F)
Weight 80 g (0.2 lbs)
P31.311.710 - 1en / 01.14

100 mm (D)
Dimensions
3.9 inch (D)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 23
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, conventional, Ex

OMX 1001C Ex Order no.: 800833


Conventional intrinsically safe optical smoke detector for Ex
zone 1. Designed for use in areas with smoke in case of re.
Robust smoke detector with drift compensation for use in
industrial environments.
Designed for use in hazard areas connected to a safety
barrier Ex Standard 9 V. The barrier has to be placed in non
hazard areas.

Product features Included in delivery


Constant funktion monitoring of sensors, software and 1 Optical smoke detector
hardware including the microcontroller. 1 Operating manual, German 901123
1 Operating manual, English 901772
Normal operation indication by green ashing light.
Automatic drift compensation.
Not included in delivery
Robust smoke detector.
Detector base 903502 or 903503
see detectors accessories, conventional
Technical specifications End of line-resistor 1.8 K / 0.5 W 675235
Dust cover 894760
Detection method Infrared photo diode
Safety barrier IS conventional 9 V 904991
Measurement chamber
approx. 0.16 dB/m (39.4 inch)
sensitivity
Number of detectors per line max. 24 Connection / mounting
Technology conventional Connection cable standard detector 2-lead
External Indication 1-lead
Operating voltage 7.6 V - 13.2 V DC Recommended cable
Quiescent current approx. 0.35 mA JEY (St) Y 2x2x0.8 mm, blue
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Alarm current approx. 18 mA
Alarm indication 1 LED red, permanent light
Note
Normal operation indication 1 LED green, ashing light The detector housing has a high surface resistance. Avoid
Electrostatic shielding existing electrostatic charging.
-20 C to +60 C
Operating temperature, T4
(-4 F to +140 F) Approvals / marking
-20 C to +40 C
Operating temperature, T6 Ex conformity in acc. with 94/9/EG
(-4 F to +104 F)
-40 C to +85 C x II 2G Ex ia IIC T6...T4 Gb
Storage temperature
(-40 F to +185 F) EC type approval certicate: DMT 00 ATEX E 043
IP 43, with membrane plug and
IP rating (EN 60529) Ex conformity Russia in acc. with TP TC 012/2011:
sealing of the mounting holes
1Ex ia IIC T6/T4 Gb
Enclosure material white polycarbonate
Relative humidity max. 95% at 35 C (+95 F)
G 200005 0786-CPD-20131
(IEC721-3-3) no condensation
Weight 240 g (0,5 lbs)
113 x 68 mm (DxH)
P31.311.130 - 1en / 01.14

Dimensions
4.5 x 2.7 inch (DxH)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 24
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, conventional, Ex
IMX 1001E Ex Order no: 782410
Conventional ionisation smoke detector for Ex zone 1. Desi-
gned for use in areas with smoke in case of re.
Robust smoke detector with a dual ionisation chamber for
use in industrial environments.
Designed for use in hazard areas connected to a safety
barrier Ex Standard 9 V. The barrier has to be placed in non
hazard areas.

Product features Not included in delivery


Drift compensation by dual ionization. Detector base 903502 or 903503
see detectors accessories, conventional
Robust smoke detector.
End of line-resister 1.8 K / 0.5 W 675235
Dust cover 894760
Technical specifications Safety barrier IS conventional 9 V 904991

Detection method two coupled ionization chambers


Connection / mounting
Sensitivity y = 0.8
Connection cable standard detector 2-lead
Technology conventional External Indication 1-lead
Operating voltage 7.6 V - 13.2 V DC Recommended cable JEY (St) Y 2x2x0.8 mm2, blue
Conductor cross-section max. 2.5 mm2
Quiescent current approx. 0.08 mA
Alarm current approx. 20 mA
Note
Alarm indication 1 LED red The detector housing has a high surface resistance. Avoid
Electrostatic shielding existing electrostatic charging
-20 C to +75 C The detector contains radioactive materials. The operating
Operating temperature T4
(-4 F to +167 F) instructions and current laws and regulations on radiation
-20 C to +40 C protection must be observed.
Operating temperature T6
(-4 F to +104 F)
-30 C to +80 C
Storage temperature
(-22 F to +176 F)
Max. usage height above Approvals / marking
approx. 3500 m (2.17 miles)
sea level Ex conformity in acc. with 94/9/EG
IP 43, with membrane plug and x II 2G Ex ib IIC T6...T4 Gb
IP rating (EN 60529)
sealing of the mounting holes
EC type approval certicate: BVS 03 ATEX 2110
Enclosure material white polycarbonate
Relative humidity max. 98% bei 35C (+95 F)
G 28119 0786-CPD-20211
(IEC721-3-3) Avoid condensation
Weight 230 g (0.5 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
P31.311.180 - 1en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 25
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional, Ex

WMX 1000D60 Ex Order no.: 782422


Conventional combined rate of rise and static heat detector
for Ex zone 1. Designed for areas with rapid rase of tempera-
ture by ames.
Heat detector with 2 temperature sensors for use in industrial
environments.
Designed for use in hazard areas connected to a safety
barrier Ex Standard 9 V. The barrier has to be placed in non
hazard areas.

Product features Not included in delivery


Adaptation to ambient temperature by 2 temperature Detector base 903502 or 903503
sensors. see detectors accessories, conventional
End of line-resistor 1.8 K / 0.5 W 675235
Combined differential and static measurement.
Dust cover 894760
Robust heat detector. Safety barrier IS conventional 9 V 904991

Technical specifications Connection / mounting


Connection cable standard detector 2-lead
Detection method NTC - temperature sensor
External Indication 1-lead
Technology conventional Recommended cable
Operating voltage 7.6 V - 13.2 V DC JEY (St) Y 2x2x0.8 mm, blue
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Quiescent current approx. 0.07 mA
Alarm current approx. 15 mA
Note
Alarm indication 1 LED red The detector housing has a high surface resistance. Avoid
Temperature class, rate of Class A1, electrostatic charging.
rise measurement acc. to EN54-5: 2000 / A1:2002
+54 C to +62 C
Static threshold value
(+129.2 F to +143.6 F) Approvals / marking
Elektrostatic shielding recommended Ex conformity in acc. with 94/9/EG
Operating temperature
-20 C to +50 C x II 2G Ex ib IIC T6...T4 Gb
(-4 F to +122 F) EC type approval certicate: BVS 03 ATEX E 104
IP 23, with membrane plug and Ex conformity Russia in acc. with TP TC 012/2011:
IP rating (EN 60529)
sealing of the mounting holes
1Ex ia IIC T5/T4 Gb
Enclosure material white polycarbonate
Relative humidity max. 95% G 27918 0786-CPD-20208
(IEC721-3-3) no condensation
Weight 140 g (0.3 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
P31.311.230 - 1en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 26
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional, Ex

WMX1000D90 Ex Order no.: 782434

Technical specifications Approvals / marking


Temperature class, rate of Class C, Ex conformity in acc. with 94/9/EG
rise measurement acc. to EN54-5: 2000 / A1:2002 x II 2G Ex ib IIC T6...T4 Gb
+84 C to +100 C EC type approval certicate: BVS 03 ATEX E 104
Static threshold value
(+183.2 F to +212 F)
-20 C to +80 C Ex conformity Russia in acc. with TP TC 012/2011:
Operating temperature 1Ex ia IIC T5/T4 Gb
(-4 F to +176 F)
Weight 140 g (0.3 lbs)
G 27918 0786-CPD-20209

Otherwise like Order no.: 782422

WMX1000D105 Ex Order no.: 907368

Technical specifications Approvals / marking


Temperature class, rate of Class D, Ex conformity in acc. with 94/9/EG
rise measurement acc. to EN54-5: 2000 / A1:2002 x II 2G Ex ib IIC T6...T4 Gb
+100 C to +115 C EC type approval certicate: BVS 03 ATEX E 104
Static threshold value
(+212 F to +239 F)
-20 C to +80 C
Ex conformity Russia in acc. with TP TC 012/2011:
Operating temperature 1Ex ia IIC T5/T4 Gb
(-4 F to +176 F)
Weight 140 g (0.3 lbs)

Otherwise like Order no.: 782422

WMX1000D80M Ex Order no.: 903508

Technical specifications Approvals / marking


+77 C to +83 C Ex conformity in acc. with 94/9/EG
Static threshold value
(+170.6 F to +181.4 F) x II 2G Ex ib IIC T6...T4 Gb
-20 C to +70 C EC type approval certicate: BVS 03 ATEX E 104
Operating temperature
(-4 F to +158 F)
Ex conformity Russia in acc. with TP TC 012/2011:
Weight 130 g (0.3 lbs) 1Ex ia IIC T5/T4 Gb
P31.311.230 - 1en / 01.14

Otherwise like Order no.: 782422

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 27
Product Sheet | Detecon

Standard detectors
Detector accessories

Deckhead mounting box ACX 196 Order no.: 905403

Back box for detector base for surface mounting, with lateral
cable entry for M20 cable glands. Stable ABS enclosure in
robust design.

Not included in delivery


Cable glands M20x1.5 902901
Blind plug 902922

Technical specifications
Material ABS
Weight 404 g (0.9 lbs)
146 x 38 mm (dia. x H)
Dimensions
5.8 x 1.5 inch (dia. x H)

Cable floor-detector holder BHX 1000, Order no.: 908691


d=20 mm to 25 mm (0.78 to 0.98)
Cable oor-detector holder for underoor installation.
The standard fastener is designed for round pipes with a
diameter of 20 - 25 mm (0.78 to 0.98 inch). Other fasteners
on request.
The plate area is designed for smoke and heat detector
bases of many detector suppliers.

Included in delivery
1 packaging unit (10 x)
Cable oor-detector holder BHX 1000
2 mounting screws 4.2 x 13 (DIN 7981-St)

Technical specifications
Material Sheet steel, powder-coated
Colour RAL 7035
-20 C to +70 C
Operating temperature
(-4 F to +158 F)
Weight 290 g (0.6 lbs)
112 x 330 mm (dia. x H)
Dimensions
4.4 x 13 inch (dia. x H)
P31.311.740en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 28
Product Sheet | Detecon

Standard detectors
Detector accessories

Parallel indicator LMX5000 Order no.: 908499

Additional alarm indication for detectors with non visible


alarm LED e.g. in false oors.
Insertable for Loop AP, MxLoop and conventional technolo-
gy.
Do not use the parallel indicator in hazard areas.

Not included in delivery


Clamping screws

Technical specifications Approvals / marking


Nominal voltage Loop AP 24 V DC
MxLoop 12 V DC
conventional 9 V DC
Electrostatic shielding not required
Enclosure material ABS, RAL9010 - white
Relative humidity 98 %, avoid condensation
-10 C to +60 C
Ambient temperature
(-14 F to +140 F)
IP rating IP 30
Weight 66 g (0.2 lbs)
84 x 84 x 35 mm (WxHxD)
Dimensions
3.3 x 3.3 x 1.4 inch (WxHxD)
P31.311.740en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 29
Product Sheet | Detecon

Standard detectors
Detector accessories
Junction box ACX 204 Order no.: 901247

Junction box for ush mounted installation by the customer in


concrete ceiling slabs, with prefabricated attachment points
for the detector base. Break-off tabs for cable entries, M16
and M20 wiring conduit.

Notes
Not applicable in combination with:
- detector base metric, 3-pin 903502
- detector base metric, 5-pin 903503
- and the associated detectors series

Technical specifications Approvals / marking


Material PC
100 x 8 mm (dia. x H)
Dimensions
3.9 x 0.3 inch (dia. x H)

Backplate ACX 233 Order no.: 901245

Protection plate against dust and water to add to the detector


base during assembly. When using addressable detectors
the number identication must be removed and inserted at
the points provided in the backplate.

Notes
Not applicable in combination with:
- detector base metric, 3-pin 903502
- detector base metric, 5-pin 903503
- and the associated detectors series

Approvals / marking
P31.311.740en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 30
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional,Ex
Junction box Ex Order no.: 900288

Junction box for hazard areas, can be used in zone 1

Included in delivery
1 Junction box Ex with 4 cable glands M25 for cable 10 -
17 mm and 2 closures M25.
6 clamps, clamping range to 2.5 mm2 (0.004 square inch)
Technical specifications
Material Polyamid
Not included in delivery
IP rating (EN60529) IP 66 Mounting hardware
Colour black

Operating temperature
-20 C to +40 C Approvals / marking
(-4 F to +104 F)
Ex conformity in acc. with 94/9/EG
Weight 300 g ( 0.66 lbs)
x II 2G Ex dem ia II, IIC T6
122 x 180 x 61 mm (WxHxD)
Dimensions EC type approval certicate: PTB 00 ATEX 3108
4.8 x 7.1 x 2.4 inch (WxHxD)
P31.311.730 - 2en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 31
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input module IUX 760 M-I Order no.: 908531


Miniature interface for use in devices with little space.
The mini switch monitor monitors the state of one or more dry
normally open contacts and reports the status to a re alarm
panel.
Applicable for operation in re alarm panels with Loop AP
protocol.
Optional equipped with interrupt for rapid alarm signals as
with a manual call point.
The states "quiescent", "pre-alarm", "alarm" and "fault" are
recognised.
Addressing via DIP switches; the address can also be
modied after installation.

Inputs : 1 Connection / mounting


Outputs : 0 Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Technical specifications Conductor cross-section max. 1,5 mm2 (0.002 square inch)
Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Quiescent current at 24 V DC: Contact input:
Min. (quiescent) 0.2 mA Voltage at contact input 9 - 11 V DC
Max. (alarm input) 3.6 mA
Cable resistance max. 50 Ohm
Alarm indication red LED Terminating resistor 20 kOhm
Bus activity indication green LED Pre-alarm resistance 10 kOhm
Main alarm resistance 1 kOhm
Short-circuit indication yellow LED
Integrated isolator yes
-20 C to +70 C
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 20
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Weight 30 g (0.1 lbs)
39 x 39 x 20 mm (WxHxD)
Dimensions
1.5 x 1.5 x 0.8 inch (WxHxD)

Approvals / marking

G 210034 0832-CPD-1072
P31.311.810 - 3en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 32
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input module IUX 822 R Order no.: 905395


Analog addressable input module for monitoring a dry contact
including line monitoring.
DIN rail (R) installation version.
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.

Inputs : 1 Connection / mounting


Outputs : 0 Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Technical specifications Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Quiescent current at 24 V DC: Contact input:
Min. (quiescent) 0.73 mA Voltage at contact input 9 - 11 V DC
Max (short circuit input, Cable resistance max. 50 Ohm
LED on) 5.6 mA
Terminating resistor 20 kOhm
Indication of closed input red LED Pre-alarm resistance 10 kOhm
Fault indication yellow LED Main alarm resistance 1 kOhm
Integrated isolator no
-20 C to +70 C
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 20
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)

Approvals

0832-CPD-0857
P31.311.810 - 1en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 33
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input/output module IOX 821 R Order no.: 905558


Analog addressable input module for monitoring a dry contact
including line monitoring.
DIN rail installation version.
The states "quiescent", "alarm" and "fault" are recognised.
The alarm status can be set with 30 seconds delay via a
DIP switch.
An opto-isolator output is available and can be used with
additional electronics to reset detectors.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.

Inputs : 1
Outputs : 1 (opto-isolator)

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 0.73 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max. (short circuit input, Electrostatic shielding not required
LED on) 5.6 mA
Indication of closed input red LED Contact input:
Fault indication yellow LED Voltage at contact input 9 - 11 V DC
Cable resistance max. 50 Ohm
Integrated isolator no
Terminating resistor 20 kOhm
-20 C to +70 C
Operating temperature Pre-alarm resistance 10 kOhm
(-4 F to +158 F)
Main alarm resistance 1 kOhm
IP rating (EN 60529) IP 20
Technology / protocol Loop AP / XP95 Opto-isolator output:
Relative humidity 0 to 95% Voltage range 5 - 30 V DC
(IEC721-3-3) no condensation Guaranteed current 1 mA
Specication according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)

Approvals / marking

0832-CPD-0856
P31.311.810 - 4en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 34
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input/output module IOX 803 R Order no.: 905803


Analog addressable input/output module for monitoring a dry
contact including line monitoring and additional opto-isolator
input, and for controlling an output via a relay.
DIN rail installation version.
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.

Inputs : 2 (of which 1 opto-isolator)


Outputs : 1

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 0.73 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (short circuit input, Electrostatic shielding not required
LED on) 5.6 mA
Indication of closed input red LED Contact input:
Active output indication red LED Voltage at contact input 9 - 11 V DC
Cable resistance max. 50 Ohm
Fault indication yellow LED
Terminating resistor 20 kOhm
Integrated isolator no Pre-alarm resistance 10 kOhm
-20 C to +70 C Main alarm resistance 1 kOhm
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 20 Opto-isolator input:
Technology / protocol Loop AP / XP95
Voltage range max. 35 V DC
Impedance 10 kOhm
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Relay output:
Specication according to CEA GEI 1-052 (6/97)
Voltage max. 30 V DC
Weight 95 g (0.2 lbs) Current max. 1 A DC
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)

Approvals / marking

0832-CPD-0854
P31.311.810 - 6en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 35
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Output module OUX 804 R Order no.: 905402


Analog addressable output module for controlling a dry
contact.
DIN rail (R) installation versions.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.

Inputs : 0
Outputs : 1

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 0.73 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (relay activated Electrostatic shielding not required
and LEDs on) 5.6 mA
Alarm indication red LED Relay output:
Integrated isolator no Voltage max. 30 V DC
-20 C to +70 C Current max. 1 A DC
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 20
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)

Approvals / marking

0832-CPD-0855
P31.311.810 - 12en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 36
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Sounder control module SCX 182 R Order no.: 905396


Analog addressable sounder control module for controlling
sounders in continuous or pulse-controlled operation with
additional contact input for monitoring the external power
supply of the sounders.
DIN rail (R) installation versions.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.

Inputs : 1 (contact input)


Outputs : 1

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 1.9 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (relay activated Electrostatic shielding not required
and LEDs on) 4.5 mA
Alarm indication red LED External power supply 9 - 50 V DC
Fault indication yellow LED
Contact input NC/NO contact

Integrated isolator no Relay output:


-20 C to +70 C Voltage max. 35 V DC
Operating temperature
(-4 F to +158 F) Current max. 4 A DC
IP rating (EN 60529) IP 20
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)

Approvals / marking

G 201095 0832-CPD-0852
P31.311.810 - 14en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 37
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

FMZ5000 loop coupler module Order no.: 902954

Functional module for use in all design variants of the re


alarm system FMZ 5000.
The loop coupler module is a loop node on a loop of the
loop module. It includes 4 conventional detector zones with
their own addresses, which are detected and dealt with by
the re alarm panel like four detectors of the detector loop.
The status of the detector zones and the detectors are re-
ported to the re alarm panel via the congured address.
Detectors can be connected in two-detector dependancies
and groups can be connected in group dependancies.
For use in hazard areas, detectors in intrinsically safe design
can be connected via Zener barriers.
The detector lines have a common base address, which is
Product features set in increments of 4 for all detector lines.
The module has a default conguration that can be modied
For the interface connection of conventional detectors to using the conguration software MxLoopCon,
a loop of the loop module. Order no. 904001.

The module has four conventional detector zones.

Alarm and pre-alarm of every zone are transmitted. Application


The zones can be deactivated individually via the loop. Mainly for the interface connection of industrial detectors in
conventional detector technology to a Loop AP.
Technical specifications A maximum of 32 automatic Minimax conventional detectors
or any type of conventional detector from other manufactur-
Operating voltage 19 V - 29 V DC ers with suitable electrical detector parameters (see Techni-
approx. 20 mA cal specications) or 10 manual call points may be connected
Quiescent current
without line terminations to one conventional line.
Current consumption per line max. 100 mA DC The module can be used directly in a re alarm panel.
In such a scenario it is supplied with power via the panel.
Line voltage, min 9 V - 19 V DC
Up to 30 modules can be connected to a detector loop.
Technology / protocol Loop AP / XP95 To supply the conventional lines, the loop coupler module
Alarm / 470 Ohm /
requires an external 24 V DC power supply.
terminating resistor 1.8 kOhm
Number of lines per module 4
Number of detectors per line 32
Included in delivery
Max. terminal cross-section 2.5 mm (0.004 square inch)
2
Module completely assembled and ready for installation in
Integrated isolator no the re alarm panel.
-5 C to +40 C
Ambient temperature
(+23 F to +104 F)
Relative humidity max. 95 % Application in potentially explosive atmospheres
(IEC721-3-3) no condensation Only permitted for use with barrier:
IP rating (EN60529) IP 20 Safety barrier standard 9 V 904991

Enclosure Polyamide PA6.6, green


Note
Installation position Vertical
The module may not be plugged in together with the other
Mounting rail 35 DIN 46277,
Mounting modules.
top hat prole
Weight 200 g (0.4 lbs)
P31.311.810 - 10en / 01.14

35 x 99 x 114.5 mm (WxHxD)
Dimensions
1.4 x 3.9 x 4.5 inch (WxHxD)

Approvals / marking

G 209028

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 38
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input module IUX 843 W-I Order no.: 905399


Analog addressable input module for monitoring a dry contact
including line monitoring.
In the version for wall-mounted installation (W).
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.
The electronics features an integrated isolator; fault
condition, short circuit or open line is indicated.

Inputs : 1 Connection / mounting


Outputs : 0 Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Technical specifications Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Quiescent current at 24 V DC: Contact input:
Min. (quiescent) 1.25 mA Voltage at contact input 9 - 11 V DC
Max (short circuit input, Cable resistance max. 50 Ohm
LED on) 3.6 mA
Terminating resistor 20 kOhm
Indication of closed input red LED Pre-alarm resistance 10 kOhm
Fault indication 2 yellow LEDs Main alarm resistance 1 kOhm
Integrated isolator yes
-20 C to +70 C
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)

Approvals / marking

G 201033 0832-CPD-0867
P31.311.810 - 2en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 39
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 841 W-I Order no.: 905398


Analog addressable input module for monitoring a dry contact
including line monitoring.
Wall-mounted installation version.
The states "quiescent", "alarm" and "fault" are recognised.
The alarm status can be set with 30 seconds delay via a
DIP switch.
An opto-isolator output is available and can be used with
additional electronics to reset detectors.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.
The electronics features an integrated isolator; a fault,
Inputs : 1 short circuit or open line is indicated.
Outputs : 1 (opto-isolator)

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 1.25 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (short circuit input, Electrostatic shielding not required
LED on) 4.2 mA
Indication of closed input red LED Contact input:
Fault indication 2 yellow LEDs Voltage at contact input 9 - 11 V DC
Cable resistance max. 50 Ohm
Integrated isolator yes
Terminating resistor 20 kOhm
-20 C to +70 C
Operating temperature Pre-alarm resistance 10 kOhm
(-4 F to +158 F)
Main alarm resistance 1 kOhm
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95 Opto-isolator output:
Relative humidity 0 to 95% Voltage range 5 - 30 V DC
(IEC721-3-3) no condensation Guaranteed current 1 mA
Specication according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)

Approvals / marking

G 201033 0832-CPD-0866
P31.311.810 - 5en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 40
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 847 W-I Order no.: 905400


Analog addressable input/output module for monitoring a dry
contact including line monitoring and additional opto-isolator
input, and for controlling an output via a relay.
In the wall-mounted installation version.
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.
The electronics features an integrated isolator; a fault, short
circuit or open line is indicated.

Inputs : 2 (of which 1 opto-isolator)


Outputs : 1

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 1.25 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (short circuit input, Electrostatic shielding not required
LED on) 3.6 mA
Indication of closed input red LED Contact input:
Active output indication red LED Voltage at contact input 9 - 11 V DC
Cable resistance max. 50 Ohm
Fault indication 2 yellow LEDs
Terminating resistor 20 kOhm
Integrated isolator yes Pre-alarm resistance 10 kOhm
-20 C to +70 C Main alarm resistance 1 kOhm
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 54 Opto-isolator input:
Voltage range max. 35 V DC
Technology / protocol Loop AP / XP95
Impedance 10 kOhm
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Relay output:
Specication according to CEA GEI 1-052 (6/97)
Voltage max. 30 V DC
Weight 240 g (0.5 lbs) Current max. 1 A DC
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)

Approvals / marking

G 201032 0832-CPD-0869
P31.311.810 - 7en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 41
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 875 W-I AC Order no.: 905561


Analog addressable input/output module for monitoring a dry
contact including line monitoring and for controlling an output
via a relay (230 V AC switchable).
In the version for wall-mounted installation (W).
The inputs can recognise the states "quiescent", "alarm" and
"fault".
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.

Inputs : 1
Outputs : 1

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 1.2 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (relay activated and Electrostatic shielding not required
LEDs on) 3.5 mA
Indication of closed input red LED Contact input:
Active output indication red LED Voltage at contact input 9 - 11 V DC
Cable resistance max. 50 Ohm
Fault indication yellow LED
Terminating resistor 20 kOhm
Integrated isolator no Main alarm resistance 470 Ohm
-20 C to +70 C
Operating temperature
(-4 F to +158 F) Relay output:
IP rating (EN 60529) IP 54 Voltage max. 48 V DC / 250 V AC
Technology / protocol Loop AP / XP95
Current max. 2 A DC / 5 A AC
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)

Approvals / marking

0832-CPD-0860
P31.311.810 - 8en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 42
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 588 W-I Order no.: 905557


Analog addressable input/output module for monitoring dry
contacts including line monitoring and for controlling outputs
via relays.
Version for ush-mounted wall installation (W).
The inputs can recognise the states "quiescent", "alarm" and
"fault".
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.
The electronics features an integrated isolator; a fault, short
circuit or open line is indicated.

Inputs : 3
Outputs : 3

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 3.0 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (all relays activated and Electrostatic shielding not required
LEDs o) 7.5 mA
Indication of closed input 3 red LEDs Contact input:
Active output indication 3 red LEDs Voltage at contact input 9 - 11 V DC
Cable resistance max. 50 Ohm
Fault indication input 3 yellow LEDs
Terminating resistor 20 kOhm
Fault indication isolator yellow LED Main alarm resistance 4.7 kOhm
Integrated isolator yes
Relay output:
-20 C to +70 C
Operating temperature
(-4 F to +158 F)
Voltage max. 30 V DC
Current max. 1 A DC
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Weight 621 g (1.4 lbs)
250 x 175 x 75 mm (WxHxD)
Dimensions
9.8 x 6.9 x 3 inch (WxHxD)

Approvals / marking

G 202052 0832-CPD-0864
P31.311.810 - 9en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 43
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Output module OUX 849 W-I Order no.: 905401


Analog addressable output module for controlling a dry
contact.
Flush-mounted wall-mounted installation (W).
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.

Inputs : 0
Outputs : 1

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 1.25 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (relay activated Electrostatic shielding not required
and LEDs on) 3.6 mA
Alarm indication red LED Relay output:
Fault indication yellow LED
Voltage max. 30 V DC
Current max. 1 A DC
Integrated isolator yes
-20 C to +70 C
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)

Approvals / marking

G 201032 0832-CPD-0870
P31.311.810 - 13en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 44
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Sounder control module SCX 852 W-I Order no.: 905560


Analog addressable sounder control module for controlling
sounders in continuous or pulse-controlled operation with
additional contact input for monitoring the external power
supply of the sounders.
Flush-mount wall installation type (W).
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.

Inputs : 1 (contact input)


Outputs : 1

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Quiescent current at 24 V DC: J-Y(ST)Y-2x2x0.8 mm
Min. (quiescent) 1.25 mA Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Max (relay activated Electrostatic shielding not required
and LEDs on) 1.5 mA
Alarm indication red LED External power supply 9 - 50 V DC
Fault indication 2 yellow LEDs
Contact input NC/NO contact

Integrated isolator yes Relay output:


-20 C to +70 C Voltage max. 30 V DC
Operating temperature
(-4 F to +158 F) Current max. 1 A DC
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)

Approvals / marking

G 201095 0832-CPD-0871
P31.311.810 - 15en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 45
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Conventional zone module ZMX 845 W-I Order no.: 905804


Analog addressable module for monitoring a conventional
zone. Automatic detectors and manual call points using
conventional technology can be connected.
Flush-mount wall installation type (W).
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modied after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.

Inputs : 1 (conventional zone)


Outputs : 0

Technical specifications Connection / mounting


Connection cable 2-lead
Operating voltage 17 V - 28 V DC Recommended cable, standard 747180
Voltage output 19 V DC or J-Y(ST)Y-2x2x0.8 mm
Limit value zone Operating voltage - 1,5 V Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Quiescent current at 24 V DC: Electrostatic shielding not required
Min. (quiescent) 4.0 mA + detector
Max (alarm event) 19.0 mA + detector Limit value zone:
Zone alarm indication red LED Voltage 19 V DC or
Fault indication yellow LED Operating voltage - 1.5 V
Cable capacity max. 50 F
Integrated isolator yes
Terminating resistor 5.1 kOhm
-20 C to +70 C
Operating temperature
(-4 F to +158 F)
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Weight 230 g (0.5 lbs)
250 x 175 x 75 mm (WxHxD)
Dimensions
9.8 x 6.9 x 3 inch (WxHxD)

Approvals / marking

G 201094 0832-CPD-0868
P31.311.810 - 16en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 46
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

FMZ5000 loop coupler Order no.: 908131


The loop coupler consists of a loop coupler module, Order
no.: 902954, which is mounted in a ushmount wall enclosure
with IP 65 protection rating. According to DIN VDE 0833-2,
Section 6.2.5, no more than the following may be connected
to an FMZ 5000 loop coupler:
e.g. max. 1 detection range with max. 1600 m (1913 square
yard) or 32 automatic detectors of a detection range or
10 manual call points of a detection range.
The only loop coupler module that may only be tted outside
the re alarm panel is the FMZ 5000 loop coupler.

Product features Application


For the interface connection of industrial detectors in
For the interface connection of limit monitors to a loop of conventional technology to a Loop AP.
the loop module.
The FMZ 5000 loop coupler can be installed directly in the
The device has a loop coupler module.
monitoring area. The voltage supply can be provided via
Can be expanded by adding another loop coupler the re alarm panel or a separate power supply unit (in
module. accordance with EN54-4 A2). If more than 32 detectors are
connected, the power supply line must have a redundant
design.
Technical specifications To supply the conventional lines, the loop coupler module
requires an external 24 V DC power supply.
Operating voltage 19 V - 28 V DC
approx. 20 mA
Quiescent current consumption
without line terminations
Current consumption, approx. 40 mA Included in delivery
2 modules without line terminations Device completely assembled and ready for installation in the
Line voltage, min 9 - 19 V DC area.
Alarm / 470 Ohm /
Supplementary sheet.
terminating resistor 1.8 kiloOhm
Number of detectors per line 32 Not included in delivery
Technology / protocol Loop AP / XP95 Mounting hardware, further cable glands.
Number of loop coupler
1, expandable to 2
modules Note
IP rating (EN 60529) IP 65 To install the device or an additional module the loop coupler
Conductor cross-section 2.5 mm (0.004 square inch)
2 supplementary sheet, Order no.:908048, needs to be
observed.
Integrated isolator no
-5 C to +40 C
Ambient temperature
(+23 F to +104 F)
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specication according to CEA GEI 1-052 (6/97)
Enclosure transparent plastic
Installation position vertical
Weight 350 g (0.8 lbs)
P31.311.810 - 11en / 01.14

187.5 x 250 x 175 mm (WxHxD)


Dimensions
7.4 x 9.8 x 6.9 inch (WxHxD)

Approvals / marking

G 209028 0786-CPD-20684

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 47
Product Sheet | Detecon

Standard detectors
Modules, addressable

SUX5000 AP monitoring module Order no.: 906973


The SUX5000 AP is a monitoring module for the installation
of fault and alarm signal transmitters in two-wire loop
systems with individual identication.
It allows the individual addressing of dry contactors such as
pressure switches, limit switches, extinguishing agent level
sensors or temperature sensors, with plain text information to
the FMZ 5000 re alarm system or Loop AP-compatible re
alarm system.

Product features Included in delivery


Integration into the switching device to be monitored. 1 packaging unit (5x)
Monitored signal path. SUX5000 AP monitoring module
Loop integration, addressing via DIP switch on module.
Special applications: Not included in delivery
connection to external contact, connection of LEDs, Fault signal transmitter
hardware fault signal suppression.

Notes
Technical specifications The SUX5000 AP can be used in combination with the
following devices:
Operating voltage 17 V - 28 V DC Universal card adapter SUX50 902698
Rated voltage 24 V DC Reed contact limit switch 886343
Float switch monitoring 879475
Quiescent current 230 A
Float switch monitoring pump house 842358
Operating current 300 A Pressure switch PM-3 792183
Integrated isolator no Pressure switch PM-10 810564
Pressure switch PMA-3 116512
-40 C to +80 C
Operating temperature
(-40 F to +176 F)
Technology / protocol Loop AP / XP95
Relative humidity 0 to 93%
(IEC721-3-3) no condensation
Weight 4 g (0.01 lbs)
38.5 x 28.5 x 8 mm (WxHxD)
Dimensions
1.5 x 1.1 x 0.3 inch (WxHxD)

Approvals / marking

G 208059 0786-CPD-20416
P31.311.810 - 17en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 48
Product Sheet | Detecon

Standard detectors
Modules, conventional

Card L leakage detector Order no.: 800707


Monitoring card for connection of LKM2001 ow detector to
FMZ 4100 and FMZ 5000 control units.

Connection / mounting
Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), solid conductor
max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve
Cable length max. 700 m (0.43 miles), at 0.8 mm
(0.03 inch) lead
Technical specifications
Number of leak detectors
max. 10
per line
-20 C to +60 C
Operating temperature
(-4 F to +140 F)
Weight 10 g (0.02 lbs) Approvals / marking
28 x 28 mm (LxB)
Dimensions
1.1 x 1.1 inch (LxB)

Card MVA L Order no.: 782239


Module for monitoring the feed cable and the solenoid of a
solenoid valve for wire break and short circuit. The card is
integrated in the valve connection box. Monitoring and trigge-
ring must be carried out with a primary control group.

Connection / mounting
Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), dolid conductor
max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve
Technical specifications
Input voltage:
- Triggering 17 V - 29 V DC Approvals / marking
- Monitoring 0 V - 10 V DC
Ampacity max. 2 A
Rated capacity of the
max. 38 W
solenoid valve at 24 V
Display, triggering 1 LED red
-20 C to +60 C
Operating temperature
(-4 F to +140 F)
P31.311.820en / 01.14

Weight 10 g (0.02 lbs)


28 x 28 mm (LxB)
Dimensions
1.1 x 1.1 inch (LxB)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 49
Product Sheet | Detecon

Standard detectors
Modules, conventional

MVA L redundant card Order no.: 904585


Using the monitoring module the feed lines to the coil of a
solenoid valve or trigger magnets are monitored for disconti-
nuity and short circuit and whether the coil is connected.
The module must be used for monitoring when a trigger ele-
ment in a re extinguishing system is responsible for several
extinguishing zones and therefore the control and the feed
lines have to be solved in a redundant design.
The module must be used within the connection housing of
the valve.

Connection / mounting
Recommended cable 2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch),
solid conductor
Technical specifications max. 1.5 mm2 (0.002 square inch), exible wire with ferrule
Input voltage
- Activation 17 V - 29 V DC Note
- Monitoring 0 V - 10 V DC
Current carrying capacity max. 2 A To monitor and control the triggering, two control groups of
two different control group modules must be used.
Power rating of
max. 38 W
solenoid valve at 24 V
Anzeige, Ansteuerung 1 LED red

Operating temperature
-20 C to + 50 C Approvals / marking
(-4 F to +122 F)
Weight 10 g (0.02 lbs)
28 x 28 mm (LxW)
Dimensions
1.1 x 1.1 inch (LxW)

Card module Sounder Order no.: 782240


Module for monitoring the feed cable of an optical and acou-
stic alarm device for wire break and short circuit. The card
must be installed into the housing of each alarm device.

Connection / mounting
Connection cable 2-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), solid conductor
max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve

Technical specifications Approvals / marking


Input voltage:
- Triggering 19 V - 29 V DC
- Monitoring 0 V - 10 V DC
Ampacity max. 0.5 A
P31.311.820en / 01.14

-20 C to +60 C
Operating temperature
(-4 F to +140 F)
Weight 20 g (0.04 lbs)
80 x 40 mm (LxB)
Dimensions
3.2 x 1.6 inch (LxB)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 50
Product Sheet | Detecon

Standard detectors
Modules, conventional

Card MVA impulse Order no.: 800112


Module for monitoring the feed cable and the solenoid of a
2/2-way solenoid valve of the impulse type for wire break and
short circuit. The NC solenoid is also connected to the card.
The card is integrated in the valve connection box. Monitoring
and triggering must be carried out with a primary control
group.

Connection / mounting
Connection cable 3-lead
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), solid conductor
Technical specifications max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve
Input voltage:
- Triggering 19 V - 29 V DC
- Monitoring 0 V - 10 V DC Approvals / marking
Ampacity max. 2 A
Display, triggering 1 LED red
-20 C to +60 C
Operating temperature
(-4 F to +140 F)
Weight 10 g (0.02 lbs)
28 x 28 mm (LxB)
Dimensions
1.1 x 1.1 inch (LxB)
P31.311.820en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 51
Product Sheet | Detecon

Standard detectors
Test equipment

Multifunction tester S1000 Order no.: 908595


Smoke & heat detector The multistimulus detector tester S1000 is intended for the
functional testing of point-type re detectors with single or
multiple sensors. As the test of different detector types can
be conducted with one test tool, it is no longer necessary to
switch between several test tools. The substances releasing
smoke and heat are generated in the test tool. The test tool
is suitable for all optical smoke detectors, ionization detectors
and heat detectors (differential and maximum detectors).
The test of the different sensors can be conducted either
individually, successively or simultaneously for all of them at
once. The required stimulus in each case is generated at the
time of the test from the corresponding smoke capsule. The
multilingual selection of the testing stimuli, as well as their
combination and sequence is menu-driven via the navigation
Product features keys and displayed on the screen. Compared to the areosol
cans the smoke capsule offers higher test capacities.
Generation of smoke and heat during one only test.
Easier and speedier maintenance procedure.
Used for optical smoke detectors, ionisation smoke Included in delivery
detectors and heat detectors (differential and maximum 1 smoke and heat detector tester head unit only
detectors). 1 smoke capsule
Reduction of testing periods.
Note
Increased testing capacity of the smoke capsules. Only heat detectors with a release temperature of up to 60 C
Automatic infrared identication of the detector. (140 F) can be tested.
Colour code LED for feedback to the operator.
Top adjustable in several positions.
Optimised method for smoke generation. Approvals / marking

Technical specifications
IP rating IP 20
+5 C to +45 C
Working temperature
(+41 F to +113 F)
-10 C to +50 C
Storage temperature
(+14 F to +122 F)
Relative humidity 0 to 85 %,
(IEC721-3-3) no condensation
Weight 750 g (1.7 lbs)
153 x 397 mm (WxH)
Dimensions
6 x 15.6 inch (WxH)
P31.311.911en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 52
Product Sheet | Detecon

Standard detectors
Test equipment

Multifunction test set S1001 Order no.: 908596


Smoke & heat detector The multistimulus detector tester kit S1001 is intended for
the functional testing of point-type re detectors with single
or multiple sensors. As the test of different detector types can
be conducted with one test tool, it is no longer necessary to
switch between several test tools. The substances releasing
smoke and heat are generated in the test tool. The test tool
is suitable for all optical smoke detectors, ionization detectors
and heat detectors (differential and maximum detectors).
The test of the different sensors can be conducted either
individually, successively or simultaneously for all of them at
once. The required stimulus in each case is generated at the
time of the test from the corresponding smoke capsule. The
multilingual selection of the testing stimuli, as well as their
combination and sequence is menu-driven via the navigation
Product features keys and displayed on the screen. Compared to the areosol
cans the smoke capsule offers higher test capacities.
Generation of smoke and heat during one only test run.
Easier and speedier maintenance procedure.
Included in delivery
Used for optical smoke detectors, ionisation smoke 1 smoke and heat detector tester head unit only
detectors and heat detectors (differential and maximum 1 smoke capsule
detector). 2 NiMH battery packs
Reduction of testing periods. 1 rapid charger 220/240 V AC; 12 V DC
Increased testing capacity of the smoke capsules.
Note
Automatic infrared identication of the detector.
Only heat detectors with a release temperature of up to 60 C
Colour code LED for feedback to the operator. (140 F) are testable.
Top adjustable in several positions.
Optimised method for smoke generation.
Approvals / marking

Technical specifications
Battery charging time 75 - 90 min.
Battery baton 7.2 V 2.2 Ah NiMH
IP rating IP 20
+5 C to +45 C
Working temperature
(+41 F to +113 F)
-10 C to +50 C
Storage temperature
(+14 F to +122 F)
Relative humidity 0 to 85 %,
(IEC721-3-3) no condensation
Weight 1250 g (2.8 lbs)
153 x 397 mm (WxH)
Dimensions
6 x 15.4 inch (WxH)
P31.311.911en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 53
Product Sheet | Detecon

Standard detectors
Test equipment

Smoke detector test kit S834 Order no.: 906947


The universal device kit with extendable breglass poles for
testing smoke detectors up to a height of approx. 6 m
(374 inch).
The smoke detector testing device can be used with the
SA3 aerosol for all smoke detectors. The swivel frame also
facilitates the testing of detectors that are difcult to access.
The test aerosol is released by touch, with a patented
membrane allowing the efcient use of the aerosol.
The aerosol is designed for use with the smoke detector
testing device to test ionisation and optical smoke detectors.
Features of the aerosol include reliable test triggering of
the detectors, residue-free use, rapid clearing and low
consumption.

Product features Included in delivery


Universal gripper for removing / mounting detectors. 1 telescopic pole 4.5 m (177.16 inch)
1 smoke detector testing device
Telescopic poles for working heights of up to 6 m 2 carrying bags
(374 inch).
Smoke detector tester for optical and ionisation smoke
detectors.

Technical specifications
Max. working height approx. 6 m (236 inch)
+10 C to +35 C
Working temperature
(+50 F to +95 F)
- 10 C to +50 C
Storage temperature
(+14 F to +122 F)
Weight 2210 g (4.9 lbs)
100 x 1290 mm (dia. x L)
Size of bag for telescopic poles
3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag
20.1 x 17.3 x 10.6 inch (WxHxD)
P31.311.911en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 54
Product Sheet | Detecon

Standard detectors
Test equipment

Smoke detector test kit S811 Order no.: 906946


The universal device kit includes everything needed for
removing, inserting and testing smoke detectors.
Extendable breglass poles are for testing and installing
detectors up to a height of approx. 6 m.
By adjusting the three-point gripper a six-stage division for
different detector diameters is possible.
The smoke detector testing device can be used with the
SA3 aerosol for all smoke detectors. The swivel frame also
facilitates the testing of detectors that are difcult to access.
The test aerosol is released by touch, with a patented
membrane allowing the efcient use of the aerosol.
The aerosol is designed for use with the smoke detector
testing device to test ionisation and optical smoke detectors.
Features of the aerosol include reliable test triggering of
Product features the detectors, residue-free use, rapid clearing and low
consumption.
Universal gripper for removing / mounting detectors.
Telescopic poles for working heights of up to 6 m
(374 inch).
Included in delivery
Smoke detector tester for optical and ionisation smoke
detectors. 1 telescopic pole 4.5 m (177.16 inch)
1 detector removal tool
1 smoke detector testing device
Technical specifications
2 carrying bags
Adjustment range 65 mm to 110 mm
of three-point gripper (2.56 inch to 4.33 inch)
Max. working height approx. 6 m (236.22 inch)
+10 C to +45 C
Working temperature
(+50 F to +95 F)
-10 C to +50 C
Storage temperature
(+14 F to +122F)
Weight 3310 g (7.3 lbs)
100 x 1290 mm (dia. x L)
Size of bag for telescopic poles
3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag 20.1 x 17.3 x 10.6 inch
(WxHxD)
P31.311.911en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 55
Product Sheet | Detecon

Standard detectors
Test equipment

Heat detector test kit S461 Order no.: 901340


Fully automated, battery-operated heat detector testing
device.
Easy to use and energy-saving thanks to activation of the
heating process when the testing device is placed on the
detector.
The detector test is carried out completely ame-free through
the use of a warm stream of air horizontal to the testing head
cup. This stream of air comes into direct contact with the
sensor chamber, allowing the detector's alarm to be triggered
rapidly and in a reproducible manner.

Product features Included in delivery


Heat radiation without an open ame. 1 heat detector testing device
Battery operated. 2 batteries
1 rapid charger 220/240 V AC; 12 V DC
Rapid battery charger for 230V AC or 12V DC on-board
power supply.
Red and green LEDs for testing status indication.
Testing time limit of max. 120 seconds.
Internal fan cools down heating element.
Energy efciency mode, automatic shutdown after
5 minutes of inactivity.

Technical specifications
Capacity 50 tests, 30 seconds each
Rapid battery charge 75 - 90 minutes
+5 C to +45 C
Working temperature
(+41 F to +113 F)
-10 C to +50 C
Storage temperature
(+14 F to +122 F)
Relative humidity 0 to 85 %,
(IEC721-3-3) no condensation
Weight 1100 g (2.4 lbs)
135 x 330 mm (dia. x L)
Dimensions
5.3 x 13 inch (dia. x L)
P31.311.911en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 56
Product Sheet | Detecon

Standard detectors
Test equipment
Smoke & heat detector test kit S823 Order no.: 906948
The complete device kit includes everything needed for
removing, replacing and testing smoke and heat detectors.
Extendable breglass poles are for testing and installing
detectors up to a height of approx. 9,3 m (366 inch).
By adjusting the three-point gripper a six-stage division for
different detector diameters is possible.
The detector test is carried out completely ame-free through
the use of a warm stream of air horizontal to the testing head
cup. This stream of air comes into direct contact with the
sensor chamber, allowing the detector's alarm to be triggered
rapidly and in a reproducible manner.
The smoke detector testing device can be used with the
SA3 aerosol for all smoke detectors. The test aerosol is
released by touch, with a patented membrane allowing the
Product features efcient use of the aerosol.
The aerosol is designed for use with the smoke detector
Universal gripper for removing / mounting detectors.
testing device to test ionisation and optical smoke detectors.
Heat detector test, battery-operated, without an open Features of the aerosol include reliable test triggering of
ame. the detectors, residue-free use, rapid clearing and low
Telescopic poles for working heights of up to 9.3 m consumption.
(366 inch).
Smoke detector tester for optical and ionisation smoke Included in delivery
detectors. 3 telescopic poles 1.1 m (43.30 inch)
1 telescopic pole 4.5 m (177.16 inch)
Technical specifications 1 detector removal tool
Adjustment range 65 mm to 110 mm 1 smoke detector testing device
of three-point gripper (2.56 inch to 4.33 inch)
Dimensions of heat detector 135 x 330 mm (dia. x L) 1 heat detector testing device
tester 5.3 x 13 inch (dia. x L) 2 batteries
Capacity heat detector tester 50 tests, 30 seconds each 1 rapid charger 220/240 V AC; 12 V DC
Rapid battery charge 75 - 90 minutes 2 carrying bags
Max. working height approx. 9.3 m (366 inch)
+10 C to +35 C
Working temperature
(+50 F to +95 F)
-10 C to +50 C
Storage temperature
(+14 F to +122 F)
Relative humidity 0 to 85 %,
(IEC721-3-3) no condensation
Weight 3300 g (7.3 lbs)
100 x 1290 mm (dia. x L)
Size of bag for telescopic poles
3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag
20.1 x 17.3 x 10.6 inch (WxHxD)
P31.311.911en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 57
Product Sheet | Detecon

Standard detectors
Test equipment

Test clamp WMX D Order no.: 719857

Function test of differential/maximum heat detectors of open


design (WMX type D).

Note
This procedure is a substit for a coarse heat test, as the
release resistance is adapted to the specic type and a
detector would not respond if the heat detector or any other
important component is defective.

Not included in delivery


Pipe extension service devices 756549
Technical specifications
Weight 380 g (0.8 lbs)
75 x 118 x 85 mm (LxWxH)
Dimensions
3 x 4.7 x 3.4 inch (LxWxH)
P31.311.911en / 01.14

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 58
Product Sheet | Detecon

Standard detectors
Test equipment, accessories

Telescopic pole 1.1 m (43 inch) Order no.: 901344

Telescopic pole 2.5 m (98 inch) Order no.: 906951

Telescopic pole 4.5 m (177 inch) Order no.: 901345

Carrying bag for telescopic poles Order no.: 906952

Detector removal tool Order no.: 906955

Set of batteries Order no.: 906954

Rapid charger 220/240 V AC, 12 V DC Order no.: 906953

Silicone membrane for testing cup Order no.: 906949


For S834, S811, S461 and S823

Aerosol retaining cup Order no.: 906950


For S834, S811 and S823

Test aerosol SA3 Order no.: 905904


For S834, S811 and S823

Smoke capsule Order no.: 908597


For S1000 and S1001

Test fire mat type 1640 Order no.: 723014

Technical specifications Operational test.

Material PU foam
Gaseous combustion products:
Carbon dioxide,
Carbon monoxide 1.55 Vol.%, 1.21 Vol.% Not included in delivery
Methane, Ethane 0.41 Vol.%, 0.02 Vol.% Base e.g. aluminium foil
Propane, Ethylene 0.01 Vol.%, 0.21 Vol.%
Propylene, Acetylen 0.11 Vol.%, 0.03 Vol.%
Hydrochlorid acid,
Note
Fluoride acid not
Customers permission for burning the mat required. Aerosols
Nitrous gases 0.035 mg/l may effect electronic devices. Pollution of magnetic mass
Ammonia and Organic bases, storages.
traces of Hydrocyamic acid 0.16 mg/l
P31.311.914en / 02.13

Weight 70 g (0.15 lbs)


500 x 400 x 20 mm (WxHxD)
Dimensions 19.68 x 15.74 x 0.78 inch
(WxHxD)

Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 59