Sei sulla pagina 1di 1

12/6/2017 Visual Interior Tool

File Help Tools


Visual Interior Tool
Settings Calculation Results [ D ]
Units Meters - Footcandles Illuminance 51fc
Power Density 20.71W/m
Room Dimensions Quantity 2

Length [X] 3.58 m Spacing Results [ D ]


Width [Y] m Spacing 1.83 x 3.2984m
3.2984
Arrangement 2x1
Height [Z] 3 m Outside Spacing X 0.61m
Outside Spacing Y 1.06m
Workplane 1 m
Ceiling Type 2x2 Comparison
Luminaire FC W/M Count
Room Reflectances A 65 14.23 3
Ceiling 50 % B 60 19.99 2
Walls 50 % C 63 29.98 3
D 51 20.71 2
Floor 20 %
Display
Criteria
Illuminance 50 fc

Power Density W/m


Dimensions Room Layout
Quantity Show Zonal Cavity Info [+]

Constraints
Spacing X [SC=2.7] m

Spacing Y [SC=2.5] m

Rows

Columns

Project Information

A B C D

EATON - METALUX (FORMER COOPER LIGHTING)


[ D ] - 2GR5-254T5A125-UNV-EBT1
Light Loss Factor 0.7 Symbol Shape Rectangular Lamp Quantity 2

Suspension Length 0 Symbol Length .53 Lumens Per Lamp 4400

Orientation 0 Symbol Width 1.17 Wattage 122.3

Copyright 2011-2017, Acuity Brands Lighting, Inc. Visual Interior Tool version: 2.0.3.1. Results generated by this tool are provided for informational purposes only, without any warranty as to
accuracy, completeness, reliability or otherwise. The calculated results may be dependent on user provided data or data provided from publicly available sources, and do not take into
account all factors and circumstances. The Visual Support Center is available at support@visual-3D.com