Sei sulla pagina 1di 1

CL

Yp

YD
PROBE
P
D
D

d
CL B

t
Yp LD

Xp Q

B = BEAM ANGLE
D = DEFECT
PQD = `P' METAL PATH READ FROM CRT
Yp = DISTANCE OF PROBE FROM WELD CENTRE LINE
MEASURED DURING UT
A = MAX.AMPLITUDE OF DEFECT ECHO AS % FULL SCALE HEIGHT
L D = LENGTH OF DEFECT MEASURED BY 6 dB DROP METHOD
t = WALL THICKNESS / WELD THICKNESS
YD = DISTANCE OF DEFECT FROM WELD CENTRE LINE
= Yp - p SIN B
d = DEPTH LOCATION OF DEFECT
= p COS B - 2 tn
A R = MAXIMUM AMPLITUDE AS % REF.ECHO HEIGHT ( REH )
A x 100
=
REH AT `p'

NOTE : IF YD IS + ve , DEFECT IS ON SAME SIDE OF WELD CENTRE LINE AS PROBE.


IF Y D IS -ve , DEFECT IS ON THE OTHER SIDE OF WELD CENTRE LINE.

REF. LV/UT-2/TAPS/1996

DRN NUCLEAR POWER CORPORATION APPD

DATE 16-7-2006 TARAPUR ATOMIC POWER STATION DATE

CHKD WELD UT : FLAW LOCATION CALCULATIONS


REWD ( FOR UT-II TRAINING PROGRAMME )
SCALE REV
DRG.NO.
SHEET 1 OF 2 0
ARK/MECH/WELD UT SHT-1