KP Green Energy-Renewable Energy Division

Project Proposal for

Installation of Sustainable Street lights


system for IIM Indore

BY:-
KP GREEN ENERGY
Ph:- 0731-3914666
1|Page
KP Green Energy-Renewable Energy Division

Table of Contents
Executive Summary ................................................................................................................ 3
Why to change HPSL lights with LED Lights: - ............................................................... 3
Major reasons to use LED Street Lights are ............................................................... 3
Improved Illumination ............................................................................................... 4
Why centralize solar system? ............................................................................................. 4
Proposal ..................................................................................................................................... 5
Quotation for centralized street light (AC) .................................................................... 6
Saving .......................................................................................................................................... 6
Operating cost & Recovery period .................................................................................... 7
Delivery TimeLine .................................................................................................................. 8
Warranty of Product .............................................................................................................. 8
Maintenance ............................................................................................................................. 8
Payment Terms ........................................................................................................................ 8
SWOT Analysis ......................................................................................................................... 9
Strength: - ...................................................................................................................................... 9
Weakness: -.................................................................................................................................... 9
Opportunity: - ................................................................................................................................ 9
Threat: - ......................................................................................................................................... 9

2|Page
KP Green Energy-Renewable Energy Division

Executive Summary
This report summaries Installation of LED Street Light and solarize the same at your site at IIM
Indore Campus in Indore. KP Green Energy will take responsibility for designing, Installation
and maintenance* of the lights.
We are proposing the replacement of HPSL(High Pressure Sodium Lamp) 150W with
LED Lamps 55W (Make:- RENESOLA) along with Solar PV System to power up the street
lights at IIM Indore campus. This proposal is based on the information we got from your end
and we have suggested the equivalent wattage of LED lamps required, However at later stage
we will visit the site and we will design the LED eco-system, which would be powered by solar
panels and provide high-class lights, which would be much energy and cost effective.

Why to change HPSL lights with LED Lights: -


Driven by promises of major energy, maintenance saving LED Street light is the next generation
technologies in field of green energy technology. LED lights provide better Illumination than
HPMH lamps of higher wattage. When solar is paired with LED it creates a zero carbon
emission street light

Major reasons to use LED Street Lights are


Less Power consumption: - hence require small capacity solar power system
Energy Saving: - LED Lights save 41-70% energy in compare to traditional
HPMH Fixtures
Less Maintenance: - With Long Life of LEDs, Light and portable design LED
Street light are having less maintenance and long life span as compare to
conventional Street lights
Good for environment: - Reduce greenhouse gas (CO2) emission hence reduce
climate change.
Easy to Control: - Can be operated automatically with Dust to down controller
which will turn lights on when low environmental lightings. Also it is having
multi stage brightness control to provide battery saving.
Improve Illumination: - LED Lights will result in improved illumination and
hence improve road safety

3|Page
KP Green Energy-Renewable Energy Division
600 565
500
500 420
400
300
206
200 144
100 50
0
Energy Consumption ( Running Operation Life (hundred
Thousand kWh/Year) cost(thousand/Year) hrs)

Sodium Vappor LED

Comparison of LED and HPS

Improved Illumination
Some of the picture showing the difference between LED and HPS lamps is
given below.

Why centralize solar system?


With many advantages over discreet solar powered street light system centralize
system will be the best suitable for the project. Some of the benefits are

Fewer Changes: - We could use existing infrastructure (poles and cabling) and hence
make system more viable.
Improved Aesthetics: - We do not need to add panel and batteries on all the poles
which make system look abrupt
Cost Effective system: - With centralization of solar power we could make system more
cost effective in several ways
Easy for maintenance: - Solar panels for all lights together it will be easier to clean
panels and also will be easy to monitor panels & batteries through UPS.
Improved quality: - In current scenario we are having least brand choice for DC Street
light

4|Page
KP Green Energy-Renewable Energy Division

Proposal
We would propose to Installation of Sustainable LED Lights power by solar power
pack.

860Nos. 55W RENESOLA high power bulb


75KW Solar Panels
12 X 5000VA Solar PCUs
2V 600AH Cell/battery bank (72 Cells)

5|Page
KP Green Energy-Renewable Energy Division

Quotation for centralized street light (AC)


Centralized light (55W)
S. Products Make Specification Qty Total
No. (Nos.
)
1 LED High Power Lamp Renesola 55W 860
16,51,200.0
2 Solar Panels (96KW) Jinko/ 250W 384
Renesola/equivalent

3 Solar UPS (60KVA) Flin Energy FLINSLIM-5K- 12


MPPT
5 Solar cells (48V HBL 2V 600AH 72
2400AH) 73,30,320.0
6 Panel Stand Flin Energy/ Custom for 96 KW 96
Make System

8 installation accessories AS Req AS Req 1


and installation

Total 89,81,520.0

Saving
Savings Analysis
Particulars HPS LED Unit
Lamps Lamps
Power Rating 150 55 W
Qty 860 860 Nos
Operating Hr. every day 12 12 Hrs.
Power consume 1548 567.6 KWh
Price of electricity 7 0* Rs/Kwh
Operation cost per day 10,836 0 Rs/Day
Operation cost per year 39,55,140 0 Rs/Year
Maintenance Cost 2,50,000* Rs/Year
2,50,00**

* for Replacement of Lamps


** for general inspection and maintenance

6|Page
KP Green Energy-Renewable Energy Division
SAVING CHART

MONEY SAVING RS.(LAKHS) CO2 SAVING (MT/ YEAR) ENERGY SAVING (KWH/YEAR)

SAVING CHART

Operating cost & Recovery period


0th 1st 2nd 3rd 4th 5th 6th 7th 8th
Column1
year Year year year year year year year year
LED +
90 93 95 97 99 117 119 121 123
Solar
Sodium
2 44 86 128 170 212 254 296 338
Vappor

(Assumptions
Life of HPS Lamp 2 Years
Life of LED Lamp 4 Years)

Graph Shows the Costing of installation and operation on yearly basis


400
350
300
250
Axis Title

200
LED + Solar
150
HPS Lamps
100
50
0
1 2 3 4 5 6 7 8 9
Axis Title

Graph Cleary shows that in as less as 4 years costing of LED and Solar PV system will be
recovered and there will be huge saving thereafter.

7|Page
KP Green Energy-Renewable Energy Division

Delivery TimeLine
Installation will be done 6-9 weeks after receiving PO.

Warranty of Product
Panels: -
o 5 Year Against Manufacturing Defect
o 10 Year for min 90% power generation
o 25 years for min 80% Power generation

Cells/Batteries: -
o 60 Month warranty (terms as in warranty card)

Renesola LED Lights


o 24 Month replacment Warranty

Inverter(PCUs)
o 24 Month Warranty

Maintenance
One-year free maintenance of complete system
Chargeable @ 1% of project cost for second year
From third year 1.5% of project cost

Payment Terms
50% Advance against work order
30% of material cost against delivery of material
20% after installation and commissioning and testing of system

8|Page
KP Green Energy-Renewable Energy Division

SWOT Analysis
Strength: -
Project promises huge saving of electricity & Maintenance with payback as less
4 years. Also we get good Illumination for better visibility, which make area safer.

Weakness: -
Initial Investment is quite high.

Opportunity: -
LED St Light is step toward green feature and it will be easier to integrate with
solar panels

Threat: -
Huge chances of getting unbalanced if not purchased with trusted installer.

Attachments
Leaflet of FLIN- MPPT Inverter
Catalog of Renesola LED Light
Renesola Panel Catalog
HBL Cell Catalog

9|Page