Sei sulla pagina 1di 5

Dynamic Modelling (DSL Workshop)

The two-day workshop Dynamic Modelling complements the DIgSILENT seminar Power Sys-
tem Stability. The whole procedure of translating a physical system into a set of mathematical
equations and implementing it using the PowerFactory simulation language DSL (DIgSILENT
Simulation Language) will be introduced and practiced.

Various aspects of the DSL language, like the description of differential equations, issuing simu-
lation events, coding dead-times etc. will be introduced systematically and each participant will
practice extensively the implementation process of various DSL models.

The number of participants is limited to 10. One workstation per participant will be available
in the training room for the exercises. Each participant should have basic knowledge about
the PowerFactory software being familiar with the PowerFactory time domain simulation func-
tions (RMS-simulation or EMT-simulation) is also required for successfully participating in
this workshop.

DIgSILENT PowerFactory Trainings Program 1


Dynamic Modelling (DSL Workshop)

Time Schedule

2 Days Training

Time Duration
Start of the training 9:00 -
1st Coffee break 10:30 30 min
Lunch break 12:30 60 min
2nd Coffee break 15:00 30 min
End of the training 17:00 -

Program

Introduction
Welcome
Presentation

1 Introduction to DSL (DIgSILENT Simulation Language)

Purpose: Build a voltage controller model using macros from the library;
Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Introduction.
Writing DSL Macros.
Initialisation.
Dynamic Models.

Level: Intermediate.

DIgSILENT PowerFactory Trainings Program 2


2 Hydro Turbine and Governor

Purpose: Build a turbine and governor model modifying existing macros and cre-
ating new ones;
Update the frame diagram;
Define Common Model, update the Composite Models and run some
tests.

Contents: Hydraulic Turbine.

Level: Intermediate.

3 Dynamic Load Model

Purpose: Define a dynamic load model using equations;


Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Dynamic Load Model.

Level: Intermediate.

4 Under-voltage Relay

Purpose: Define an under voltage relay model using the DSL event function;
Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Under-voltage Relay.

Level: Intermediate.

DIgSILENT PowerFactory Trainings Program 3


5 Switched Shunts

Purpose: Define a shunt controller model using the DSL event function;
Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Switched Shunts.

Level: Intermediate.

6 Steam Turbine and Governor

Purpose: Define a steam plant model including turbine and governor;


Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Steam Turbine and Governor.

Level: Intermediate.

7 User-defined Excitation System

Purpose: Define an excitation system;


Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Excitation system.

Level: Advanced.

DIgSILENT PowerFactory Trainings Program 4


8 STATCOM

Purpose: Define a STATCOM model;


Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: STATCOM excercise.

Level: Advanced.

9 Fully Rated Converter Wind Turbine

Purpose: Define a Fully rated Converter Wind Turbine model;


Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Fully rated Converter Wind Turbine exercise.

Level: Advanced.

10 Fixed Speed Induction Generator (FSIG) Model

Purpose: Define a FSIG model;


Build a frame diagram;
Define Common and Composite Models, run some tests.

Contents: Fixed Speed Induction Generator (FSIG) exercise.

Level: Advanced.

DIgSILENT PowerFactory Trainings Program 5

Potrebbero piacerti anche