njsa%& ;g vkx.ku tuin y[ku gsrq Lohd`r orZeku 'ksM~;wy vkWQ jsV~l
U;wure cktkj njksa ij vk/kkfjr fo'ysf"kr njksa ij xfBr fd;k x;k gSA
voj vfHk;Urk
vuqj{k.k [k.M lgk;d vfHk;Urk
vuqj{k.k [k.M vf/k'kklh
vuqj{k.k vfHk;Urk
[k.M
ua0&1flfoy ua0&1flfoy ua0&1flfoy
yks0fu0fo0] y[ku yks0fu0fo0] y[ku yks0fu0fo0] y[ku
./13.., Dated-10-07-2013
d;k tk jgk gSA
vf/k'kklh
vuqj{k.k vfHk;Urk
[k.M
ua0&1flfoy
yks0fu0fo0] y[ku
CHECKING PROFORMA
Preliminary and Detailed Estimate
Sl.No. Particulars
1 Report-
(a) Proper reference have been quoted and attested copies attached with the estimate.
(b) In case of revised estimate the amounts of excess has been given Item wise in the
comparative statement with detailed reasons.
(c) Signatures of A.E., E.E., & S.E. exist.
(d) Details of forest land with name of village & chainage.
(e) Required certificates are mentioned or not.
(f) Name of JE/AE who surveyed the work for preparaion of estimate.
2 Specifications-
(a) Detailed specifications for each item of work are included in the estimate.
(b) Each design has been signed by E.E. & S.E. in the end, and important designs by C.E. as
well.
4 Analysis of Rates-
(a) Analysis of non-schedule items are based on the market rates is attached or not.
(b) Each analysis have been signed by J.E.,A.E., E.E. & S.E. in the end.
5 Details of measurements-
Each page has been signed by J.E.,A.E. & by E.E. in the end of each set.
6 Bill of Quantity-
Each page has signature of J.E. , A.E. and E.E. at the end of each set.
7 Summary of estimated cost-
These have been signed by J.E., A.E., E.E. & S.E.
8 Plans-
These have been signed by J.E., A.E., E.E. & S.E.
9 General-
1- Name and designation should exist, below all signature and corrections.
2- Each page of the design, analysis of rates, details of the measurements, bill of quantity and
summary of estimated cost should be certified 'checked and corrected' by JE(T) of
divisional office and circle office with their signature at the end.
10 Designation-
Divisional Office:- Construction Division No. 1, P.W.D., Lucknow
S.No. Name Designation
1 Er. Vijay Kumar Junior Engineer, M.D.-1 (civil), UPPWD, Lucknow.
Yes/NA
Yes/NA
Yes
NA
Yes
Yes
Yes
Yes/NA
Yes/NA
Yes/NA
Yes
Yes
Yes
Yes
Yes/NA
Yes
Yes
ucknow
Signature
Summarey of Estimated Cost
: Ykksd fuekZ.k foHkkx izeq[k vfHk;ark dk;kZy; ifjlj esa
Total = Rs.
Say Rs. In Lacs
Amount
277101.45
2771.01
4156.52
284028.99
2.84
Executive Engineer
Maint. Division No.-1(Civil)
P.W.D. Lucknow
fo"k; lwph
dz0la0 en dk fooj.k
1 'kh"kZd i`"B
2 tkap izi=
3 fo"k; lwph
4 izfrosnu
5 lUnHkZ
6 fof'kf"V;kW
7 nj fo'ys"k.k
9 ykxr dk lkjka'k
10 ekufp=
i`"B la[;k
--------
fof'kf"V;kW
UNIT
QTY.
911.80 Sqm
44.82 Sqm
11.50 Sqm
968.12 Sqm
DESIGN
: Ykksd fuekZ.k foHkkx izeq[k vfHk;ark dk;kZ
Sl.No. Description
1 Roof Toop Total Area
2 Average annual Rain Fall
3 Run-off co-efficient
4 Total availability of Water from roof
top area taken in to consideration
10 Type of aquifer
11 Proposed recharge structure
12 Rain water collecting system
13 Re-charge tank
14 Filtration chamber
15 Recharge well
Specification
988.12 Sqm
963.00 mm
0.80
988.12 x 0.963 = 951.56 cum/year
40 days
32.00 mtr
0.56 cm/year
Quaternary alluvium clay, kanker, silt
and sand
Unconfined
PVC Pipe
4.00 mt x 3.00 mt x 2.25 mt = 1 No
1.00 mt x 3.00 mt x 1.25 mt = 2 Nos
110 mm dia (100mm nominal size) 35
mt deep )=1 No
761.25 cumt
15225.00 cumt
DETAILS OF MEASUREMENTS AND BILL OF QUANTITY
: Ykksd fuekZ.k foHkkx izeq[k vfHk;ark dk;kZy; ifjlj esa
Sl. ITEM OF WORK MEASUREMENT UNIT
No. N0. L. B. H. QTY. RATE
1 Earth work in excavation by mechanical means (Hydraulic
excavator) / manual means over areas (exceeding 30cm in depth.
1.5 m in width as well as 10 sqm on plan) including disposal of
excavated earth, lead upto 50m and lift upto 1.5m, disposed earth
to be levelled and neatly dressed.All kinds of soil (Item Code DSR-
2013-2.6.1)
10 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm
to 2 mm in recharge pit, in required thickness over gravel layer, for all
leads & lifts, all complete as per direction of Engineer -in-charge
5054.25
13770.00
64220.00
18541.60
22455.90
AMOUNT
21618.90
4794.00
28455.00
3414.60
3414.60
4980.00
13938.75
AMOUNT
8477.00
6708.75
7377.00
6553.20
25920.00
AMOUNT
17212.20
195.70
277101.45
BILL OF QUANTITY
dk;Z dk uke & fo'oS'ojS;k izs{kk x`g ds lq/kkjhdj.k ,oa lkSn
dk;ZA
2 Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering-all work upto plinth level 1:4:8 (1 cement:4
coarse sand:8 graded stone aggregate 40mm nominal size) Cum
3 Class- 150 brick work in 1:4 mortar (1 cement:4 coarse sand) in foundation and
plinth including supply of all materials, labour, T&P etc. required for proper
completion of the work. Cum
4 20 mm Cement plaster in single coat on rough side of single or half brick wall for
interior plastering upto floor two level including internal rounded angles
chamfers, and rounded angles not exceeding 80 mm. in girth and finished even
and smooth.( 1 Cement :3 coarse sand ) including Extra for providing and mixing
water proofing material in cement plaster work in proportion recommended by Sqm
the manufacturers.
5 R.C.C. works with cement approved coarse sand 2cm (3/4") gauge approved
stone ballast in the proporation 1:1.5:3 ( 1 cement :4.5 aggregate) in slabs
excluding supply of reinforcement and its bending the same with 24 B.W. G.G.I.
binding wire and includuing necessary centering and shuttering etc. and also
including supply of all materials, labour, T&P etc. required for proper completion Cum
of works. Strength of the concrete shall not be less than M- 20.
6 R.C.C. works with cement approved coarse sand 2cm (3/4") gauge approved
stone ballast in the proporation 1:1.5:3 ( 1 cement :4.5 aggregate) in slabs
excluding supply of reinforcement and its bending the same with 24 B.W. G.G.I.
binding wire and includuing necessary centering and shuttering etc. and also
including supply of all materials, labour, T&P etc. required for proper completion Kg
of works. Strength of the concrete shall no be less than M- 20.
7 Providing and fixing factory made precast RCC perforated drain covers, having
concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced
with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars,
including providing 50 mm dia perforations @ 100 to 125 mm c/c, including
providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as Each
per direction of Engineer-in-charge. ( Item Code DSR-2013-24.9)
10 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2
mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all
complete as per direction of Engineer -in-charge Cum
11 supply of Stainless steel wire guage (Grade-304) aperture 1.4 mm and 0.50 mm
Sqm
dia wire ( Item Code DSR-2013-8737)
12 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable
method prescribed in IS: 2800 (part I), including collecting samples from different
strata, preparing and submitting strata chart/ bore log, including hire & running
charges of all equipments, tools, plants & machineries required for the job, all
complete as per direction of Engineer -in-charge, upto 90 metre depth below Rmt
ground level.All types of soil 300 mm dia ( Item Code DSR-2013-24.1.1.1
15 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to
establish maximum rate of usable water yield without sand content (beyond
permissible limit), with required capacity air compressor, running the compressor
for required time till well is fully developed, measuring yield of well by "V" notch
method or any other approved method, measuring static level & draw down etc.
by step draw down method, collecting water samples & getting tested in
approved laboratory, i/c disinfection of tubewell, all complete, including hire &
labour charges of air compressor, tools & accessories etc., all as per Hr.
requirement and direction of Engineer-in-charge. ( Item Code DSR-2013-24.12)
16 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe
of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required
size complete.100 mm clamp . ( Item Code DSR-2013-24.14.1) Each
17 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes 6.0
kg.cm2 pressure conforming to IS : 13592 Type A, including jointing with seal
ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single Rmt
socketed pipes.including all fittings 110mm dia
19 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe
assembly of tubewell as per IS:2800 (part I)..100 mm dia . ( Item Code DSR-
2013-24.15.1) Each
TOTAL AMOUNT
Say
GENERAL CONDATATION
1 All the work shall be carried out as per latest P.W.D. specifications and as per instructions of Eng
2 VAT/Trade Tax and Income tax/Labour Cess shall be deduct as per rule.
3 T-I and T-II form will part of the agreement.
4 The quantities given in the bill of quantity are approximate and are liable to wide variation either
compensation shall be considered expect a resonable extension of time for increased quantities
5 Each tender should accompany general stamp of Rs. 100/- alongwith 1/- revenue stamp pasted
Bill of Qty
Qty. Rate AMOUNT (in Rs.)
2.70 13770.00
5100.00
275882.55
Rs. 275,883.00
ION
as per instructions of Engineer-in-charge
e to wide variation either side for which no claim or
e for increased quantities.
)............... ( ) /
Sig. of Contractor
with name and address
dk;Z dk uke
- 04
.
- 04 - M-2-1191