Sei sulla pagina 1di 11

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP
UB

PIN
REP

ES

STANDARD BARANGAY HEALTH STATION


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
PERSPECTIVE

A C E A C E

PROPERTY LINE

PROPERTY LINE
1 1

2 2
PROPERTY LINE

PROPERTY LINE

BOTON BHS BOTON BHS

FLOOR PLAN ROOF PLAN


SCALE 1 : 100 M SCALE 1 : 100 M

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

1
UB

PIN
REP

A
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
A B D E 3 1

NEO - PATRIOT TYPE BHS NEO - PATRIOT TYPE BHS

FRONT ELEVATION RIGHT SIDE ELEVATION


SCALE 1 : 100 M SCALE 1 : 100 M

E C A 1 3

NEO - PATRIOT TYPE BHS NEO - PATRIOT TYPE BHS

REAR ELEVATION LEFT SIDE ELEVATION


SCALE 1 : 100 M SCALE 1 : 100 M

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

2
UB

PIN
REP

A
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
A C E

2
SCHEDULE OF DOORS & WINDOWS

REFLECTED CEILING PLAN


SCALE 1 : 100 M

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

3
UB

PIN
REP

A
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
A C E A C E

1 1

2 2

FOUNDATION PLAN ROOF FRAMING PLAN


SCALE 1 : 100 M SCALE 1 : 100 M

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

1
UB

PIN
REP

S
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
COLUMN FOOTING PLAN COLUMN FOOTING SECTION

REINF. BARS
TYP. DETAIL OF COLUMN FOOTING TYPICAL DETAIL
SCALE 1:20 MTS
SCALE 1 : 40 M

F-1

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

2
UB

PIN
REP

S
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
A-A B-B A-A

BOTTOM BARS
BEAM SECTION A-A BEAM SECTION B-B
AT SUPPORT AT MID SPAN
FLOOR BEAM/ROOF CANTILIVER BEAM
BEAM/GIRDER

TYP. BEAM LONGITUDINAL SECTION


SCALE 1 : 20 M

WF-1 SECTION WF-2 SECTION a


b
c
d
e

WALL FOOTING DETAIL


SCALE 1 :30 M TRUSS DIAGRAMS
SCALE 1 :100 M

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

3
UB

PIN
REP

S
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
A C E A C E

1 1

2 2

WATERLINE LAYOUT SEWAGE LAYOUT


SCALE 1 : 100 M SCALE 1 : 100 M

SEWAGE DIRECT FEED/COLD WATERLINE


RISER DIAGRAM SCHEMATIC RISER DIAGRAM
NOT TO SCALE NOT TO SCALE

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

1
UB

PIN
REP

P
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
INLET SECONDARY THIRD
COMPARTMENT COMPARTMENT COMPARTMENT

TO SEWER
PLAN

AIR SPACE AIR SPACE


AIR SPACE
WATER LEVEL
WATER LEVEL
WATER LEVEL

TO SEWER

INLET SECONDARY THIRD


COMPARTMENT COMPARTMENT COMPARTMENT

SEPTIC TANK DETAILS


SCALE 1:20 MTS
SECTION
PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

2
UB

PIN
REP

P
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
PLUMBING LEGEND:
GENERAL NOTES AND SPECIFICATIONS:
1. IT IS NOT INTENDED THAT THE DRAWINGS SHALL SHOW EVERY PIPE GATE VALVE SV SHOWER VALVE
FITTING, VALVE AND APPURTENANCE. ALL SUCH ITEMS WHETHER KS KITCHEN SINK
SPECIFICALLY MENTIONED OR NOT, OR INDICATED ON THE DRAWINGS CHECK VALVE
LT LAUNDRY TRAY
SHALL BE FURNISHED AND INSTALLED IF NECESSARY TO COMPLETE THE F FAUCET
SYSTEM TO THE SATISFACTION OF THE OWNER. FD FLOOR DRAIN
M WATER METER
2. ALL PLUMBING WORKS SHALL BE INSTALLED IN ACCORDANCE WITH THE HB HOSE BIBB
PROVISION OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES, THE WC WATER CLOSET
CWL
REQUIREMENTS OF THE LOCAL PLUMBING INSPECTION OFFICE, PERTINENT COLD WATERLINE
LAV LAVATORY
PROVISIONS OF THE UNIFORM BUILDING CODE AND THE NATIONAL
BUILDING CODE OF THE PHILIPPINES. WASTE PIPE
BT BATH TUB
FB FOOT BATH
3. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND
SPECIFICATION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY SOIL PIPE CWR COLD WATER RISER
DESCREPANCY FOUND THEREIN. VSTR VENT STACK THRU ROOF
4. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY CO CLEAN OUT
STORM DRAIN PIPE
RELOCATIONS REQUIRED FOR PROPER EXECUTION OF OTHER TRADE SD SHOWER DRAIN
SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT. VP VENT PIPE
VENT PIPE WP WASTE PIPE
5. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL
LOCATION, DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND SP SOIL PIPE
STRUCTURES AS VERIFIED BY THE CONTRACTOR. CB CATCH BASIN MV MAIN VENT
6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% UNLESS VAC VENT ABOVE CEILING
OTHERWISE SPECIFIED. AD AREA DRAIN FCO FLOOR CLEANOUT
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS. UFV UNDER FLOOR VENT
CCO CEILING
8. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT THE SITE, CLEAN OUT HRP HORIZONTAL
COORDINATE THE WORKS WITH THE SEWER LINE EFFLUENT DISPOSAL RAINWATER PIPING
POINT AND WATER LINE SERVICE CONNECTING POINT, UNLESS OTHERWISE DS DOWNSPOUT CP CONDENSATE PIPE
SPECIFIED. DS DOWNSPOUT
9. ALL FIXTURES SHALL BE INDIVIDUALLY VENTED. RECEPTOR
RD ROOF DRAIN
10. THE INVERT OF THE INLET PIPE OF A SEPTIC TANK SHALL BE AT A LEVEL TB TERMINAL BOX

11.
NOT LESS THAN 50.8mm (2") ABOVE THE INVERT OF THE OUTLET PIPE.
TO PREVENT CONTAMINATION OF UNDERGROUND WATER SOURCE NO SELF CLEANING WATER
VS VENT STACK
CATCH BASIN DETAILS
FILTER (AQUA FILTRO BRAND SCALE 1:20 MTS
SEPTIC TANK SHALL BE CONSTRUCTED LESS THAN 1.20m ABOVE THE OR APPROVED EQUAL)
WATER TABLE LEVEL. F
12. ALL PIPE SIZE ARE IN MILLIMETERS AND ALL DIMENSIONS ARE IN METERS
UNLESS OTHERWISE SPECIFIED. MATERIALS SPECIFICATIONS:
13. MINIMUM SEWAGE PIPE SIZE SHALL BE AS FOLLOWS:
SOIL PIPE
WASTE PIPE
VENT PIPES
DOWNSPOUT
14. ALL PLUMBING INSTALLATION INCLUDED HEREIN SHALL BE UNDER THE
DIRECT SUPERVISION OF A DULY REGISTERED AND LICENSED MASTER
PLUMBER.

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

3
UB

PIN
REP

P
ES

STANDARD BARANGAY HEALTH STATION 3


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION
A C E A C E

1 1

2 2

LIGHTING LAYOUT POWER LAYOUT


SCALE 1 : 100 M SCALE 1 : 100 M

S
Sab
Sxyz

PROJECT TITLE : DESIGNER : CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET NUMBER :

OF T HE PHI
C L
LI
IP

1
UB

PIN
REP

E
ES

STANDARD BARANGAY HEALTH STATION 1


TH
DE

LEGAZPI CITY
AL
PA

RT
ME HE CROMWELL C. PADUA, UAP, RMP ROENGEN N. PUNZALAN CE,SE MYRNA J. LISTANCO MD,MPH. GLORIA J. BALBOA MD, MPH, MHA, CEO VI, CESO III
NT OF
Architect II RCE Chief - LHSD Regional Director
LOCATION : BICOL REGION

Potrebbero piacerti anche