Exhaust gas recirculation system - exploded view Page 1 of 2

Exhaust gas recirculation system - exploded view


1 - 25 Nm
 Renew

2 - Lower
connecting
pipe for
exhaust gas
recirculation
 When
installing,
first tighten
finger-tight
and then
tighten to
specified
torque

3 - 22 Nm

4 - Gasket
 Renew

5 - Coolant hoses

6 - Exhaust gas
recirculation
valve -N18-
with exhaust
gas
recirculation
potentiometer -
G212-

7 - 10 Nm

8 - O-ring
 Renew

9 - 10 Nm

10 - Air hose
 Fitting instructions Fig.

11 - Seal
 Renew if damaged or leaking

12 - Intake manifold connection


 With intake manifold flap motor -V157-

13 - O-ring
 Renew

14 - Intake manifold
 Removing and installing Rep. Gr.23

15 - Gasket
 Renew

16 - 22 Nm

vw-wi://rl/A.en-GB.A03.5909.89.wi::35546235.xml?xsl=3 29/01/2012
Exhaust gas recirculation system - exploded view Page 2 of 2

17 - Upper connecting pipe for exhaust gas recirculation


 When installing, first tighten finger-tight and then tighten to specified torque

18 - 22 Nm

19 - Gasket
 Renew

20 - Gasket
 Renew
 Note installation position

21 - 25 Nm

22 - Exhaust gas recirculation cooler


 Removing and installing Chapter

23 - 10 Nm

24 - Gasket
 Renew

Fitting instructions for air intake hoses


When installing air intake hoses with plug-
in connectors, ensure that the securing clip
-arrow- engages audibly on the retaining
lug -A-.

vw-wi://rl/A.en-GB.A03.5909.89.wi::35546235.xml?xsl=3 29/01/2012