Sei sulla pagina 1di 8

Miraco

MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

COOL EER
R22 220V ~ 50Hz 1Ph HEAT COP

Heat Pump

High Wall Split Systems

12K - 18K - 24K 30K - 36K

Plasma Green
Tropical
Plasma Green

Smart LCD Auto Auto Auto Restart Refrigerant


Technology
Compressor Wireless Control Fan Speed Function Leak Detection
12K-18K-24K
Ionizer Ionizer Efficient My My Mode Save Auto 3 3 Minutes Easy Flexible
Technology AMS
AMS Mode Fucntion Mode Min. Time Delay Installation
30K-36K

IAQ Efficient Efficient Smart Independent Anti Anti-Freezing Easy Fast Service
Fans Airflow Dehumidification Freezing Protection & Maintenance
Anti-dust Filters

Self Clean Efficient Air flow Turbo High


Temp.
High Temp. Cleanable
Function Coils Auto Swing Function Protect Protection Front Panel

Fashion Inner Groove Auto Swing Follow Me Cold Draft Washable


Design Copper Tubing Vertical Air flow Function Protection Air Filters

LCD Hydrophilic Auto Swing ECO Sleep Defrost Optinal


Display Aluminum Fins Horizontal Air flow Function Protection WiFi WiFi Kit

LE Efficient Super Louver Position Timer Self diagnostic Can be connected


Operation Quiet Memory Function Functions function BMS with BMS
High Wall Split Systems
R22
Heat Pump
High Wall Split is the optimum air conditioning solution
for places which require high wall installation, elegant appearance and
ultimate comfort combined with efficient, quiet operation, optimum air
distribution, and efficient Indoor Air Quality (IAQ).
KEY FEATURES
Healthy and Clean Indoor Air Quality (IAQ)
Plasma Technology ( Only with Systems 12K - 18K - 24K )
Plasma Green air purifier generates a high voltage electrostatic field. Plasma Green

The air passing through this zone is converted to Plasma, and 95% of
the dust, smoke and pollen particles are attracted to an electronegative
filter for clean and healthy air.
Ionizer Technology ( Only with Systems 30K - 36K )
SMART CONTROL Ionizer generates large quantity of negative ions for refreshing air, Ionizer
killing germs, removing smoke and dust particles.
Ionizer gives an immediate sensation of energy and well-being.

Efficient carbon - electrostatic air filter for odors and microscopic


dust removal.

Efficient anti dust washable air filters. IAQ

Infrared wireless Self Clean function which is used after cooling mode to automatically
remote control clean and dry the indoor coil of indoor unit to prevent the bleeding of
odors and bacteria.
EFFICIENT, TROPICAL & QUIET
Modern Aesthetic Design
Attractive appearance with compact dimensions and light weight.
Fits any interior decor with space saving.
LE
Smart LCD display which shows control functions and error code
( in case of a malfunction ).

Efficient Tropical Operation with


Minimum Electrical Consumption
OUTDOOR UNIT Patented heat transfer and aerodynamics technologies to ensure LE
prefect tropical operation up to 52C outdoor ambient temperature
for energy saving and low operating cost.
Efficient super tropical compressor works in high ambient
temperature up to 52C with high efficiency and low electrical
consumption leading to true powerful system cooling.
12K - 18K - 24K 30K - 36K Efficient Air Management System (AMS) leading to maximum air
flow with minimum turbulence for minimum air resistance, smooth AMS
airflow and efficient operation.

Carrier innovative uneven aerofoil tangential blower technology


for efficient operation at all speeds with maximum air flow.

Efficient indoor and outdoor coils with large heat transfer surfaces
for minimum electrical consumption.
www.miraco.com.eg

Enviromental Safety
Efficient trapeziform Inner groove copper tubing compared with
Management System Management System traditional copper tubing, it allows more refrigerant flow, improves
ISO 14001 : 2004
Certificate No : 12 104 30334 TMS
BS OHSAS 18001 : 2007
Certificate No : 12 116 30334 TMS
heat exchange efficiency and lowers power consumption while
keeping the same capacity output level.

Precoated Hydrophilic Aluminum Fins of indoor coil to protect the coil


-MRA against corrosion and to allow easy and quick removal of unrestricted
condensate water between the fins to increase wet airflow, improve
2 EGAC heat exchange efficiency and accelerate cooling process.
Key Features
Quiet with Minimum Sound Level Durability
Patented cross flow fan, elephant ear propeller, new Anti-rust, weather proof and long life outdoor unit
heat exchangers, improved Air Management System sheet metal parts made of chemically treated and
(AMS), and quiet rotary compressor. zinc coated ( galvanized ) sheet metal.
Complete Control Functions for Comfort Powder painted casing of outdoor unit with
prefect adhesion of highly resistant ployester
Smart LCD infrared wireless remote control with paint 60-80 micros thick, which is electro-statically
complete control functions built in the control system applied and baked at a temperature of 220C.
to ensure comfort at all operating conditions.
Smart supply air flow for comfort cool or comfort Optional Pre-coated Aluminum Fins for outdoor
heat as per the selected mode for optimum coil to protect against corrosion in the coastal
distribution of supply air temperature and velocity installation areas.
inside the space to be air conditioned.
Complete Safety & Reliability Functions
Auto-swing horizontal supply air louver to up and down
for optimum distribution of supply air temperature and Auto restart function with backup memory.
velocity inside the space to be air conditioned. When the power failure is happened during the
air conditioner operation, the microprocessor of the
Auto-wing of vertical supply air louvers to right or left printed circuit board will memorize the operation
for optimum air distribution of supply air temperature setting. After the power is recovered, the air conditioner
and velocity inside the space to be air conditioned. operates automatically ( without remote control after
elapse of compressor time delay ), according to the
Louver Position Memory Function previous operation settings.
When you start the unit next time, the angle of
horizontal supply air louver will automatically move 3 (three) minutes safety time delay between 3
to the same position as you set last time. compressor turning off and turning on for
compressor protection against cycling. Min.
Auto fan speed function which automatically changes
the fan speed to high or medium or low speed by Auto Anti-freezing protection of indoor coil when the air
sensing the temperature difference between conditioner is operating in cool mode with excessive Anti
room temperature and setting temperature. dirt on the indoor coil and / or clogged air filters Freezing
Auto mode which automatically changes the and / or low ambient temperature operation of
operation mode and capacity output by sensing the cool mode.
temperature difference between room temperature High temperature protection of outdoor coil when Hi Temp.
and setting temperature. the air conditioner is operating in cool mode. Protect
Cool
Independent Dehumidification mode which efficiently This protection is only for heat pump system.
dehumidifies the room, but not lower the temperature Cold draft protection when the air conditioner is
so obviously as cooling mode. operating in heat mode to prevent blowing out of
My Mode save function which memorizes the cold air at the beginning of heat mode which in turn
preferred settings of mode, fan speed, temperature My avoids the user discomfort.
and supply air position. This function recalls preferred Mode Hi Temp.
High temperature protection of indoor coil when the
settings upon request. air conditioner is operating in heat mode.
Protect
Heat

Turbo function which automatically changes the fan


speed to maximum speed to maximize the cooling Defrost protection of outdoor coil when the
capacity output to cool down the room rapidly and to air conditioner is operating in heat mode at very
attain the desired temperature in the shortest time. low ambient temperature.

Follow Me function for smart control of comfortable Smart self-diagnostic function for malfunctions
temperature when you stay close to the remote detection for easy fast service and maintenance.
control. With this technology, an efficient
temperature sensor is built in the remote control just Smart Refrigerant leak detection by sensitive sensor
like the air conditioner is following you. mounted on the indoor coil for easy fast service and
maintenance.
ECO ( sleep ) function for energy saving, quiet and
comfortable healthy sleep which automatically The components of both indoor and outdoor units
changes fan speed to low speed and controls both comply with international standards of performance
set and room temperatures. and safety.
Programmable timer for easy on and off selection Easy Installation, Service and Maintenance
with energy savings including off timer, on timer,
off/on timer and on/off timer functions. Flexible multi outlet locations for piping from the
indoor unit, easy piping connections and easy electrical
Optional Smart WiFi Kit connections between outdoor and indoor units.
Carrier has introduced an Android app or IOS App,
which can be used to control the operation of your Easy accessibility to all key components.
WiFi
Rev. (0) - 2017

air conditioner remotely via an app called Net Home Common spare parts across product family.
Plus. through your smart mobile phone.
Easy removal of front panel for cleaning by easy
disassembly of panel engagement with the cabinet
The air conditioner can be connected to Building of indoor unit.
Management System (BMS) BMS
Easy removal of washable air filters for cleaning
by opening the hinged front panel up and then
pulling filters down outside the indoor unit. 3
High Wall Split Systems

Key Features
Plasma Green

Plasma Green Technology ( Only with Systems 12K - 18K - 24K )


Plasma Green air purifier generates a high voltage electrostatic field. The air passing through this zone is
converted to Plasma, and 95% of the dust, smoke and pollen particles are attracted to an electronegative filter.
High electric volatge field Electronegative filter

Polluted Air Fresh Air

Oders
+5KV Dust electrode
Particles Generating plasma
discharge

Ionizer
Ionizer Technology ( Only with Systems 30K - 36K )
Ionizer generates large quantity of negative ions for refreshing air, killing germs, removing smoke and dust
particles. Ionizer gives an immediate sensation of energy and well-being.
Ionizer has the following advantages :

Eliminates bacteria and dust mites.


Remove bad odors, smoke and domestic smells.
Eliminates potentially pollutants and chemicals.
Alleviates fatigue, allergies, body paints and disease.
Increase feeling of calmness, reducing irritability
and depression.
Improves energy and alertness.

Self Clean Function


Self Clean function which is used after automatically cooling mode to clean and dry the indoor coil of indoor
unit to prevent the bleeding of odors and bacteria.
When Self Clean function is activated, firstly, the indoor unit operates as fan - only mode with low fan speed
initially. Then during this period the condensed water will take away some dust on the fins of indoor coil.
After that the indoor unit turns to heat mode with low fan speed which dries the inside of indoor unit.
Finally the indoor unit turns to fan-only mode and blows away the wet air.
The whole process cleans the internal side of indoor unit and
www.miraco.com.eg

prevents the aspiration of bacteria.

Fan Only Mode Heat Mode Fan Only Mode


With Low Fan Speed With Low Fan Speed Operation

4
Key Features
Smart Air flow
Smart supply air flow for comfort cool and heat as per selected mode for optimal air distribution of supply air
temperature and velocity inside the air conditioned space.
During cool mode, the supply air flap is opened
counter-clockwise, which leads the supply air to blow out
horizontally and then fall down by its gravitation. This results
in effectively reducing the temperature difference between top
and bottom air space and achieve uniform temperature inside
the room in the fastest way.
Cool Mode

During heat mode, the supply air flap is opened clockwise, which
leads the warm air to fall directly on the floor vertically. Since hot
air is lighter than cold air around, it will diffuses upward quickly.
This results in effectively reducing the temperature difference
between top and air space.
Heat Mode

Follow Me Function
Carrier Follow Me technology makes your air Ordinary temperature Follow Me temperature
conditioner follow you for smart comfortable sensor location sensor is built-in to the remote control
temperature.
When Follow Me function is activated, the room
temperature sensor built into the remote control
is activated and replaces the room temperate
sensor installed inside the indoor unit.
Then the air conditioner regulates the room
temperature based on the temperature around Normal Operation Operation with Follow Me Function
the remote control which is close to you.

Turbo Function
Turbo function is used when you first come
home or when you have unexpected guests.
When Turbo function is activated, the air
conditioner operates in its maximum speed for
20 minutes to maximize the output of cooling
capacity.
Rev. (0) - 2017

Carrier Turbo cooling technology makes your


room cool down rapidly, and attain the desired
temperature in the shortest time.

5
High Wall Split Systems

Key Features
ECO Sleep Function
- ECO ( Sleep ) function is useful when you go to sleep. This function is useful for energy saving,
quiet and comfortable healthy sleep.
- When ECO ( Sleep ) function is activated the air conditioner changes automatically the setting temperature
which in turn, changes automatically the room temperature to maintain the most comfortable
temperature and to avoid overcooling during cool mode or overheating during heat mode.

Smart Technnology WIFI Conntrol ( Optional )


( Only with Systems 12K - 18K - 24K )
APP Smart Phone, Freely Control Whenever and Wherever
Control the air conditioner and set a timer easily
through the APP on your smartphone. You can
turn on the air conditioner in advance and enjoy
the cooling room as soon as you arrive home.

The application is available at...

What do I need to connect the WiFi ?


When the installation of the air conditioning unit is complete, you will need
www.miraco.com.eg

WiFi Module Display PCB WiFi Network Your


Not included in the ( with Wi-Fi in your home Smartphone
6 package of the unit function ) or tablet
Wireless Remote Control
Display Of Remote Control
1 3
AUTO SET TEMP. FAN 2
COOL HIGH
2
DRY MED 5
HEAT TIMER ON OFF LOW

2 3
5 4 67 8
1 4
8
6 9 1 Signal transmission indicator

2 MODE indicator
7 10
AUTO Automatic
11 14
12 13 COOL Cooling

DRY Dehumidification only

HEAT Heating

FAN Ventilation (fan only)


Control Buttons
3 ON / OFF indicator
MODE selection button
1 AUTO - COOL - DRY - HEAT - FAN 4 SET TEMP. indicator
Decrease temperature button
2 Each time you press the button, the temperature decreased by 1C 5 FAN SPEED indicator
Increase temperature button
3 Each time you press the button, the temperature increased by 1C LOW FAN SPEED indicator LOW
FAN selection button
4 High - Medium - Low - Auto fan speed MED FAN SPEED indicator MED
5 ON/OFF button
HIGH FAN SPEED indicator HIGH
Vertical Air Flow Auto Swing
6 Press to change louver 6 degree AUTO FAN SPEED indicator AUTO
Vertical Air Flow Auto Swing
Press less 2 seconds the louver will swing up and down 6 TIMER ON function indicator
automatically
7 Horizontal Air Flow Auto Swing 7 TIMER OFF function indicator
Press more 2 seconds the louver will swing left and right
automatically 8 FOLLOW ME function indicator
8 ECO ( Sleep ) function button
9 TIMER ON function button
10 TIMER OFF function button
My Mode function button
11 to memorize the preferred settings
Follow Me function button
Press less 2 seconds to activate
12 Plasma Fresh Air function button
Rev. (0) - 2017

Press more 2 seconds to activate


LED Display function button
Press less 2 seconds to activate
13 Self Clean function button
Press more 2 seconds to activate
14 TURBO function button 7
Technical Specifications
System type Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump
System model 53QHCT12-708J 53QHCT18-708J 53QHCT24-708J 53QHET30-708F 53QHE36-708F
Indoor unit model 42QHCT12-708J 42QHCT18-708J 42QHCT24-708J 42QHET30-708F 42QHE36-708F
Outdoor unit model 38QHCT12-708 38QHCT18-708 38QHCT24-708 38QHET30-708 38QHE36-708
Btu/hr 12100 18000 24000 28800 34500
Cooling capacity
kW 3.55 5.27 7.03 8.44 10.11
Input power - Cooling W 1148 1761 2335 2863 3416
Input current - Cooling A 5.30 8.40 11.12 14.07 16
Btu/wh 10.54 10.22 10.28 10.06 10.10
E.E.R. - Cooling
W/W 3.09 2.99 3.01 2.95 2.96
Btu/hr 10800 18500 25000 28500 31750
Heating capacity
kW 3.16 5.42 7.33 8.35 9.30
Input power - Heating W 992 1594 2220 2479 2872
Input current - Heating A 4.70 7.60 10.45 12.60 14
C.O.P - Heating W/W 3.18 3.40 3.30 3.37 3.24
Indoor unit model 42QHCT12-708J 42QHCT18-708J 42QHCT24-708J 42QHET30-708F 42QHE36-708F
Dehumidification l/h 1.2 1.8 2.6 3.2 4.2
cfm 215 / 250 / 315 295 / 375 / 450 470 / 550 / 660 531 / 661 / 796 619 / 733 / 912
Nominal air flow (low/med/high)
m /hr
3
364 / 424 / 534 500 / 636 / 762 797 / 932 / 1119 900 / 1121 / 1350 1050 / 1243 / 1546
Sound Pressure (low/med/high)
measured in anechoic sound testing lab dB(A) 30 / 35 / 41 30 / 36 / 42 38 / 43 / 49 46 / 49 / 52 47 / 51 / 54
as per ISO 3745 standard
Sound Pressure (low/med/high)
measured in reverberation sound testing lab dB(A) 38.5 / 41.8 / 47.5 42.2 / 44.9 / 49.3 44.8 / 47.7 / 53.9 47.4 / 52.9 / 56.5 51.3 / 54.9 / 59.1
as per ISO 3741 standard
Net Dimensions (WHD) mm 812 x 300 x 192 973 x 319 x 218 1082 x 338 x 225 1250 x 325 x 230 1450 x 340 x 265
Net Weight kg 9 12 15 19.5 27
Outdoor unit model 38QHCT12-708 38QHCT18-708 38QHCT24-708 38QHET30-708 38QHE36-708
Compressor type Rotary Rotary Rotary Scroll Scroll
Refrigerant type / Coupler type R22 / Flare R22 / Flare R22 / Flare R22 / Flare R22 / Flare
Sound pressure dB(A) 58.1 60.7 60.9 64 65
Net Dimensions (WHD) mm 770 555 290 770 555 290 845 x 700 x 330 860 x 720 x 350 860 x 720 x 350
Net Weight kg 31 39 50 64 68
System Installation Data
Pipe connection sizes ( Gas x Liquid ) inch 1/2 x 1/4 1/2 x 1/4 5/8 x 3/8 5/8 x 3/8 3/4 x 3/8
Maximum pipe length m 10 20 20 25 25
Maximum height difference m 4 10 10 10 10
Condensate drain hose diameter inch 5/8 5/8 5/8 5/8 5/8
Recommended Wire Size / No. of Wires mm 2
3 mm 2
4 mm 2
4 mm 2
6 mm 2
6 mm2
from Power Supply to Outdoor Unit ( Qty) ( 2 Wires +1 Earth ) ( 2 Wires +1 Earth ) ( 2 Wires +1 Earth ) ( 2 Wires +1 Earth ) ( 2 Wires +1 Earth )
Recommended Wire Size / No. of Wires mm2 1 mm2 1 mm2 1 mm2 1 mm2 1 mm2
between Outdoor Unit and Indoor Unit ( Qty) ( 5 Wires +1 Earth ) ( 5 Wires +1 Earth ) ( 5 Wires +1 Earth ) ( 3 Wires +1 Earth ) ( 3 Wires +1 Earth )
Power supply V/Ph/Hz 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
* Cooling Capacity and Energy Efficiency Ratio (EER) based on ES3795 / ES 4814 / ISO 5151 Standards at operating conditions :
35C Ambient Temperature. 27/19C db/wb Indoor Temperature. 220 volts power supply. High Air Flow
Rev. (0) - 2017

* Systems work in cooling at high ambient temperature up to 52C


* Cooling Capacity & EER tolerances 5%
Five Years
* Heating Capacity and Coefficient of Performance (COP) are based on ES 4814 / ISO 5151 Standards at operating conditions : free supply
20C db Indoor Temperature. 7/6C db/wb Outdoor Temperature. 220 volts power supply. High Air Flow
19111
19111
spare parts
* Carrier is committed for continuous improvement of Carrier products according to national and international standards First Year
to ensure the highest quality and reliability standards, and to meet market regulations and requirements. full warranty
8 for product For Customers
All specifications subject to change without prior notice according to Carrier policy of continuous development. & Service & Sales

Potrebbero piacerti anche