Sei sulla pagina 1di 70

T-I(iT-IT()I-I t=l{

With Lytecaster@,
artistry in downlighting
takes on new dimensions.
Properly planned and
executed, downlighting
becomes an art form
that can transform
the ordinary
into the extraordinary.
Downlighting molds space. . .

enhances color and texture. . .

focuses attention .

creates a special
ambrence. . .and
fulfills the promise
of a design concept.
LYTECAST ER. DOWN LI G HTI N G
Lightoliels Lytecaster downlights Versatility
offer a broad choice of lighting Fixlu res of matching appearance-
functions, quality levels and a wide black baffle, black cone, gold cone
range of styles for many or clear cone-can
app lications: open reflectors with be used with "A",
cone or baffle apertures, lenslights, "R" or "PAR"
flush or dropped diffusers tor lamps to provide
general lig hting; wall washers; INCANDESCEI{T OR
various lig hting FLUORESCEI{T DOWNLIGHTS
adjustable accent lig hts; surlace e{fects.
mounted cylinders and wall brackets.
All are thoroughly engineered to
provide high efficiency and are ,*,.rl,r,t;""",o
,. . , AOJUSTABLE
''@: OR LOW VOLTAGE
sturdily constructed of high quality llgr
J
l5 rldve
I ACCENT LtcHTS
materials. apertures tl-at
lnnovations
l\4any fiftures have been specifically
!ri.*lii;?li
wasners._
wal' -g
*i.. rno""r"
designed to utilize {M; permtttrng d rlterent
new energy-effective \-ai lighting effecls to be conbi'red in
lighl souri'es: low ,i.ru Le/7t one instarlation. while ma i'llai'.] ing
voltaoe l\,4R-16 a'rd .L/1/ /", a consistency of appearance.
PAB-56 incandescenr \ /''
lamps and corpa.t 4.. l1' Superior Quality
lono life PL fluoreseerr \\ prn.se
Accurately formed ref lectors
lamps. 'a)". redirect light into useful zones,
assuring permanent h igh efficiency.
Low voltage adjustable accent maximum lig ht output.
lights and downlights offer a wide They are of three quality
choice of intensities and beam levels: Alzak ' (best),
spreads and great versatility for Anobrite" and
en hancinq displays, art objects, Perma White. All
prized possessions. reflector trims are of
aluminum or other
Snap-in sockets on PAR-36 units non-ferrous materials
assure new ease and will not rust.
in relampino nv illl'jl
eliminating the Captive gaskets on Twist-Tite
need for tools dif{user fixtu res seal housing to
when connecting glass and g lass to
leads to lamp ceiling, prevent d irt
terminals. and moisture from
entering fixture.
The compactness of the PL
fluorescent lamp permits the design
of shallow reciangular or square
diffuser fixtures which can be Flexibility of Application
recessed in 3% " depths. Also Ad iuslable {ampholders provide
available are round open or enclosed flexibility for using
fixtures that may be used in place of a variety of lamp
less eff icient i ncandescents. sizes, maintaining
the proper f ilament
These exciiing new light sources position and
can also be retrofitted into existing g rvrng maxrmum
Lytecaster instal lations, without visual cut-ofi
costly alterations. As new Iight to the lamp.
sources are developed, Lightolier
will keep pace by continuing to
expand its Lytecaster system. Ease of lnstallation
Lytecaster and 7.11 recessed
Glean Detailing downlights are adaptable to new
Step baffles and aperture cones or existing construction. l\4ost units
are precisely fitted will fit situations where ceiling
into housings, depths are limited to 8".
g iving a clean, Easy{o-install Frame-l n Kit/
crisp appearance. Reflector Trim systems and
Housing/Apertu re systems sim plify
installation. Trims and apertures are
installed after ceiling is completed,
protecting fixtu res from damage.

2 / t- t(' Ft r<> t- I t= tr-'


CONTENTS INDEX
STYLE NO STYLE NO

How to Plan, Select 1AO2


t002PT
13
13
1178
1178.1C
51

and lnstall Lightolier 1003P1


I005
13
13
1179
1182
49

.....
51

Recessed Downlights .4-7


1006
1007
. 15
13
1182.|C
1144
55

1008 13 1185 . 5T

Guide to General Lighting 8-9


1010
1011
13
15
1T88.
1T89. 59
1021 .59
Lighting
15 1T 91

Guide to Accent 30-31 1022


1045 .
41
13
1193.
1194. C
59
.58
1046 13 1 196
1055 .35 T 199 59
1058 35 1202 25
1060 35 1242P1 25
1065 35 1221 25
1066 .35 1222 41
1067 35 1226 25
1071 45 1224 25

Lytecaster 8.43 1076


1142
.45 1241

Lighting
17 1602 27
11A24C 52 1607.
General B-29 1142P1 .17 1608
29
29

lncandescent .
1103P1 .17 1801 61
. .10-21,24-25 1105 19 r803 61

Fluorescent 22-23,26-29
1105.|C
1106
1107
1108
54
19
19
19
1806
1B2l
1423
1826
61
61
.61
61
Accent Lighting 30-41 110B.lC 53 1837 61

Low Voltage 32-39


11T0
I I Io.lc
11 16
T9
53
23
1833
1836
1841
61
61
61
Line Voltage 40-41 1T 18

1120 .23
23 1843
1846
61
61

Wall Washing 42-43


1121
1122
1122.|C
1125
.55
.43
21
41
1902
1907
1908
r 954
. 27
29
29
62
1126 21 955 62
7 o11
T

44-51 1127
1127.|C
40
57
1956 62
62

General Lighting . 44-51 T 135


1136.|C
.21
43
51
1958 ..
1959 ..
1960
62
62
62
Accent Lighting 1137
I137.|C
40
51
1967
1962
62
62
1141 .21 1964 62
and Wall Washing 50-51 1143
.

17 1965 62
1l43.|C 53 1970 62
1144. .17 1971 62
1144.|C 53 1972
DGoIG . . . 52.59 I T45
1 146
17
17
'1973
1974
.

.62
62

62
Lytecaster 52-57 1147 .
1147.|C
4A
57
2AO2
2402P1
11
11

7 o11 58-59
1 149
1 150
1151 .17
17
11
200s
2007
2008
11
11
1T

1152 31 2010 . 1l
1155 2052 .33
Surface and Wall 1155. C
1158 .. .39
56 2053
2055

Mounted Downlights 60.61


1158. C
1 160
56
39
2057
2058
33

1160. C 56 2064 33
1161.]C 56 2061
1162 .39 2062
Accessories 62 1 165 7249 61
1166 . .37 7259 61
1167 7550

Lighting Performance Data 64-66


1174
1171
11114C
1175
47
.47

49
7557
7552
7553
7554
33

54 7555
1176 47 7556
1176.1C .54
1177 49

We ese've rfe glI o cLaro" opdts o, das9t


a'er ..ld l.d appia arcF ot -.ed-ce rL'l ltor dno TsliJl*:fll
t"* rn any way thar wir not

r-t('r.rT()t-il=trJ/3
How to Plan Effective Recessed Lighting
Recessed fixtures can provide three Accent lighting is most often Wall Washing
basic types of lighting: General provided by incandescent fixtu res Downward "washes" of light create
Lighting; Accent Llghting; Wal because incandescent lamps have smooth illumination of vertical
Washing. lvlany spaces may use all compact f ilaments which permit surfaces irom ceiling to floor. They
three types and some only one or accurate control. Beanrs of light may be used to expand space
two. A well-planned lighting scheme can be aimed where needed and visually. define a space, light a wall
matches the proper type of lighting intensit es can be varied to produce o{ pictures or prized possessions,
with the intended use of the space. the contrasts of high ight and em phasize color and texture.
shadow requ red for effective Wall washers which use
General Lighting accent light ing. incandescent "A" or "R" lamps
Fixed beams, generally medium to These fixtures have adjustable provide a smooth wash of
wide. provide an overall spread of ampholder assem blies which rotate brightness up to the ceiling line.
ilumination that creates a soft 358'horizontally and adjust from 0" wiihout scallops. The distance of
luminosity ihroughout a space. to 45' vertically, permitting them to wall washers from the wall and
General lighting can be provided provlde accent lighting on their center'to'center spaci ng
by either incandescent o compact horizontal or vertical surfaces as deterrnine the intensity and the
fluorescent sou rces. well as downlighting from sloped smoothness of the light. Recessed
lncandescent lamps provide a ce i lings. wall washers direct the light to the
most pleasing color q uality-one wall at pre-set aiming angles,
that enhances the warm tones n an Adlusiab e Lo[r providing smooth illum ination
Voltage accent which flattens textu res and
obiect. compliments complexions lights g ive
and creates a cozy, inviting accLrrate y conceals minor wall im perfections.
atmosphere. contro led narror,r
Fluorescent lamps use much less to wide bearns
energy than incandescent lamps.
and last onger. Savings in
operating costs provide a rapid
payback for the somewhat higher
initial cosis, especial y where lights Adjustable accent lig hts are
are used contlnuously. available for operation with
standard line vo tage lamps or low
Bef eclors in lncandescent vo tage lamps. The low voltage
downlights g ve wlde beams,
Tnax m ze the ighi outplt ot lamps gather and direct light more
econorn ca A amps precisely than standard voltage
lamps and offer a broader selection
of beam spreads. N4ost importantly.
low voltage lamps em ta white.. Smooth il um nation from wal washeTs
brighter light that improves color ights a wa I of pictures and adds
G rend ition. produce less radiated dimens on to vertical surfaces.
heal, provide '.rore intersilv per
watt and ower overall operating Combinations
cosis. Different types of lighting may be
combined. according to the needs
r-T-
L 14,1
A Low vo tage amps
d rect ight to
of the s pace.
d sianl objects
It 1.)F-l
lF,{ w th more control
and ess watlage

1ffi, than standard


vo laqe lamps

Wlde beams irom a group of down ights


glve overall genera i urnination.

Accent Lighting
Adl ustable accent lighting provides
directional illumination that focuses
attention on a specific space.
object or task. Useful for
highlig hting painiings, scu lptu re,
merc hand ise displays, special
areas. Narrow to w de beams lrom adlustable Genera and accent ghling rnay be
accent lghts tocus atientlon on p ants, combined lo provide overa I ll!mination lor
sculplure and paintings. tl alpd adr Ll gl-l gi rgofdi od.-ir"
department store or boutique.

4/ r-r(tr-rr()l-t t= r?'
How to Select Lightolier Recessed Downlights
fyte_caster@
recessed downllghts c_arry UL labels and markings and are in compliance with UL Standard
1571 and the National Electrcal Code.
of the appropriate Frame-tn Ktts for the rypes of f ixtures discussed betow, the

io ,^ ily,Ig 9!d9lll9,
,I9..:lT?LrgtJoler
'olrow,'lg syrnbols are USed throughour rr-iS b'ochLre:
l)Therrally Protected: O Non-The.maty Dr"otecleo, A DC.rC.
Each comp ete
^Hemooeler Kt and!\4ecaster dolinllght consists of two numbers: Frame-ln Kit and Ref ector Tiim or
Hellector Trim Each number must be ordered separately.

NON.TYPE I.C. FIXTURES


Thermally Protected Fixtures
I' For at cett ngs lhermal protector in fixture safeguards aganst
overheatin-g lrom improperly placed insulation. lniulation if
any, must FRAME.IN KIT
FOR THERMALLY
be kepi 3" awav'roT rixtLre s,oes ano w.^g co.rparlments,
rsLlar ol rnJsl 'tol oe placeo above fixlLre -

O Non-Thermally Protected Fixtures


For Use ln Suspended Ceilings
For use in suspended cei ing installations or where thermal FRAME.IN KIT

.5
FOR NONJTHERMALLY
protect on is not required by local code jurisdict ons. .'& iRor'aciir; FiifliE

f fnermally Protected Remodeler Kits


For irreguiar ceiling conditions and ceilings up to 2,, thlck. Thermal
. ,4{1ts
protector safeguards against overheating irom improperly placed insulation. ,4 DF rn.*o.."pRorEcrED
n:uooelen xtr

TYPE I.C. FIXTURES {


'8.

lThermally Protected DCoIC Fixtures


UL listed for Direct Contact with lnsulated Celling materials. DC.IC
'xtJres have beer spec,a ty oesigned ro operale it sale te.loeratlrres
when bJried c insulatron. UL Slaloards reqlrire l'ler.ral oroteclo.s for
these fixtures to insure against overheallng due to incorr;ct ampttg.
The heat problems encountered when a recessed lightino fixture is buried
in nsulation are so severe that imitations n lamp ty:pe, ihieldino ingte PROTECTED
a-d wattage rust be accepred. -1ese sacriiices in'iigntirq pert6rrarce
may be unwarranted unless the thermal requirements-of direct burial type
insulation are of paramount lmportance.
TO USE OF FIXTURES III TYPICAL IIISTALLATIOIIS

Typical Two Story House with Basement Typical Hi.Rise Building

r-r(tFtT()l_il=t?'/5
l OOO.2OOO Frame-ln Kits

CHOICE OF APPEARANCE
ol o, irT Chtness rcf cclor
W de ahoice
tfIr]s baJflcs. cor.rs. it nlrarieS. -oye-
ba s i ush or drcpp-.d difl!sersr i.r
dia-rieters :r.m 3j, t.r !l', f I
i.lto Iranre irr kils.

MOUNTING BAR(S) JUNCTION BOX THERMALLY PROTECTED


a For wood joist or suspended o Easily accessillle from bolh . Frame-ln Kits 2002P1, 1002P1.
ceilings: extends up lo 27". sides; J-Box is parallel la 1A2P1, 1202P1 have buillin
a Maximum sirength prevents mounling bars. thermal protectors to safeguard
sagg rng. . Saves ilme and expense: buill, againsi overhealing resuliinq
a Friction grip holds bar in place. in cable clamp. ground wire. pry- f rom improperly placed insulation.
a 20" Mouniing Bar Extenders- out knock-outs and safety-edged
Set oi 2 iAccessory No. 1964) for covers.
of f.center positioning of mounting . U.L. listed for Through Wiring
frame belween ioists spaced up (2 in-2 out. 60"C or 4 in-4 out,
to 24" . 75"C).
a Concealed Spline Ceiling Kit a U.L. ljsted tor Damp Locations.
{Accessory No. 1965) for use with l'
concealed ceiling runners.
o T-Bar Anchor Clips (Accessory
No. 1956) anchor mouniinq bars
to T-Bars. /

7.

BREAK"OUT SECTIONI
ANCHOR CLIPS FLANGELESS
a Works in existing ceilings. H MOUNTING FRAME
Permits irame to be put easily a Versatile. Works for both new
through ceiling oPenlng. Push in and existing cel/irgs (excePf
anchor clips (supolied) secure 2002\.
frame {except 2002). a Tirre'saving inslallation.
?''/ v'1/ Opening can be cut aller ceiling
is insialled.
a ,Assrrres clean. neal
installation, acts as precision
cutting template.
a No sharp edges.
a For plastel ceilings. use
Plaster Rinq.

6/Lr('r-rT(>t-rl=re"
EASY INSiTALLATIOI{
l{EW CEILINGS EXtSTtlitc cEtLtl{cs cEtlll{cs uP To 2 " TlilCK
With Frame-ln Kits With Frame-ln Kits With Remodeler Kits
2OO2, 2OO2P1, tOO2, tOO2Pt, loo2, loo2Pt, 1102, 11O2P1, too3Pt, ltoSPl.
lt94.tc, 1202, 12O2P1.
ti",',i;l z,' 123)fr .
6[3i: _
Frame.ln ..' Cut Open Gut Open U)
Hammer .a1 ..? Use f rame as Use template .=
mountingbar tabs ;_Z- template. provided. \<
joists.
into
c
o
E
Wire.ln (s
Wire-ln Wire-ln
Snap{ff cover; Snap-off cover; LL
pry out K.O.; Snap-off cover;
insert cablei
pry out
insert cable:
K.O.; pry out
insert cable:
K.O.;
o
tighten clamp;
connect ground
tighten clamp;
connect ground
tighten clamp;
o
and supply leads. and supply leads.
connect ground
and supply leads. o
Close-ln Put Thru Put Thru NI
L4ark approximate
fixture location.
Remove break{ul
section and pass i
Pass Remodeler
through hole, junction o
lnstall ceiling. frame through box first; push mounting
o
Cut Open ,<;
hole.

Anchor
nng up tnlo cetttnq.

Anchor
o
F
as
Use frame h, Push anchor Insert 3 Retainino
template. clips into ceiling. Clips through
^K
Iu) slots in mounting

ffi Clips.
Sel Roro f
Snap refiector 44-
Snap.On
Set Folo Clips.
nng.

Snap-On
Snap reflector
-i.""ii.i"#i"t
cup
(,
=g lq l
Snap ref lector
trim onto socket
trim onto socket
cup.
cup.

Push Up Push Up Push Up r-\


Push up selJ- Push up self- push Uo reflector L.:l
leveling reflector leveling reflector trim L^ S
trim. trim
t / \,
T.BAR CEILINGS CONCEALED SPLII{E CEILINGS
Anchor clips can MouNTTNG BAF (For ceiling runners up to
be used to - 4,, above finished ceiling)
quickly lasten Q- t*otntt
mounting bars to -)i;
-:=4 l-'
T-Bars. t-'' --t\,l ^ / vo-Nr\uBAB
ANCHOR CLIP [']">.\
-%\
PLASTER CEILINGS Attach bracket accessory to mounting bar.

\-.. 2,, la 2j/,


'...._..1i/t'Ia 2,,

Plaster ring accessories are it \


installed after mounting f rame Secure bracket to ceiling runner. Holes in mounting bars allow
before plastering ceilings. adjustment of heighls lrcm 1:2,' to Z/,,'.
l-t(iFtT()t-t t= ItJ / 7
GENERAL LIGHTING
Either incandescenl or comPact
fluorescent fixtures may be used for Performance Downlighting
general downlighting. The choice is Precislon Downlighting
dependent upon the functions and Al2AK
aesthetics o{ a space.
Incandescenls are usual ly preferred
/ \ neruecron -]
'' ANOBBITE
BFFIFcroR

where a warm, inviting ambience is


lI
desiredi fluorescents are likely to be
the best choice where energY
eJJectiveness is most important and
especially where lights are used
continuously. MOBE LIGHT THAN ANOBRITE.] IllORE LIGHT THAN
OB WHITE BEFLECTOB WHITE BEFLECTOE
INCAl{ DESC E1{T DOWNLI HTS G
Recessed incandescent downlights BEST LIGHT OUTPUT BETTER LIGHT OUTPUT
use the smallest, most effectively Optically engineered Alzako reilector is Anobrite" reflector of anodized aluminum
formed lrom high purity aluminum. lts controls light rays to avoid scatler, providing
controlled lamps whose light output polished mirror finish pro!ides the ultimale more usable lighl. Rellector has permaneni
can be easily directed downward in lighl control tor rnaximurn efticieqcy and high reflectivily.
through low-brightness aperlures. permanence.
As a result, the illuminated objects,
rather than the ceiling fixtures,
become the dominant points of
interest in a space.
lncandescent lamps provide an
excellent rendition o{ warm colors, SHIETDEt)
ZONE
which create a friendly environment.
personalize work spaces and
heighten morale. \>,
LVtecas'ter downlights are STRAY
//r\
primarily used with economical A'
BRIGHTNESS

lamps and efficient "R" lamps. CO TROL


Accurately f o.meo specular AlTak BEST GLARE CO TROI BETTER GLARE
Deep, highly polished reflector provides a Deep housinc allows tace of lamp to be
and anod ized aluminum Anobritej' low-brightness effecl and the greatest regressed, and aperrure baffle or cone Io
reflectors provide a choice of shielding angle- particularly impolant in provide deep shieloing angle. prevenling
lighting quality levels. with varying ceilings over B'. Unobtrusive. annoying glare irom open units.
degrees of light outptrt and glare
control.

r-i_l
r,
1 :,

)
lncandescent ':::
Reflector Lamp
lncandescent -/- ,-
General Service Laf.lp f?.- .... :/ :- --
.a ( i,. "-.-
'1,/

\
\
.-
i,' \t) :
v.1
'::
-
,-'-:-_._.
._ _ ,- -- .i,r1--

ffi& -';, 'i


--. t- \=
f ./ -'-.1;j
L 1;,' \J .,
\' '.
n. '\: .::'
.,r'' ,;.
/l
FLUORESCEIIT DOWI{LIGHTS
Fluorescenl downlights are very The table blelow shows the Versatility
energy-effective since thev use energy and lamp cost savinas of pL
much less eneray than Lytecastef.r Pl-lamp {luorescent
fluorescent lamps versus sohe downlights offer a choice of styles,
incandescent down lig hts-as much commonly used incandescent "A"
as 70% less. PL fluorescent lamps sizes and lampings. Because of the
lamps and takes into consideration PL lamp's compact size, some
(by North American Philips; see lhe energy loss in the ballast and
page 3.1 for other manufacturers) fixtures are less than 31/2" deep,
lamp replacement cost. allowing recessed installation in
last up to 13 times as lonq as For example, two PL-13
incandescent lamps which saves on 2" x4" slud walls, showcases, as
fluorescent lamps (34 watts, well as in ceilings.
the cost of lamp replacements. includino ballast) provide the same
PL lamps are especially ef lective Fixtures may be used in lobbies,
light output as one l00W corridors, stairhal ls, kitchens,
where lighting is used continuously, incandescent lamp. When used 10
as in corridors, and permit f reedom bathrooms and utility areas.
hours per day @ 100/KWH, a Appliques may be used on flush
in designing small, shallow fixtures 2-PL-13 lamp fixture saves $22
that are inconspicuous and flexible mounted diffusers to creale
annually. Fluorescent lighting also economical signage. Rou nd
in application. PL lamps have a saves on air conditionino costs
color temperature of 2700'K, dropped d iffuser fixtures are
because f luorescent ligh"ting gasketed and may be used as
provide qood color rendition and produces less heat.
blend well with incandescent, Warm shower lights.
White or Warm White Deluxe
fluorescent lamps. Ease of Maintenance
Lytecaster f luorescent downlights
FLUORESCEI{T VS. INCANDESCENT with flush and dropped diffusers
can be cleaned and relamped
ENEBGY AND LAlllP C0SI SAVINGS: 00LLAnS PEB YEAB
COMPABISONS FOB EOUAL LIGHT easily.
24 HBS/DAY 1() HRS/DAY 5 HBS/OAY "Snap-lok" mountings on
tlrr0Brsct\T dor rla
-A[tps I 'rca,rorscllrr rnvps" lCorr ) lBus nessl
rectangu lar and square acrylic
I ;
l .l l
i'-"1 " I
l
diffuser fixtures permit the diffuser
t
l

1-PL7 I q. I ,oo I ro ooo lr.low I qrr I rroo 11 27 43 4 10 2 g


to be snapped ofJ and on the
'l-PLg 0 b00 r0 000 1.40w an.
12 I | I n66 11 25 40 3 10 16 2 5 I housing. "Twisllok" mountings on
2-PL7 lq 0 | r0
800 l-60w Bio t0
000 | ,0 12 34 56 3 12 21 2 6 11
round Lexantt diffuser units permil
1-P113 ',7 0 I o00 l-60w 870 1000
0 000 | 18 40 63 6 16 3 8 13 the diffuser lo be removed with jusr
2-PLs I 401100 0.000 11-75W I I90 Ii50 19 45 72 6 17 28 3 o 14 one "twist-open" action and
?.Pr13l 34011800 1 0.00011-100w i r"ol,n6 23 58 93 I 22 37 4 l1 18 resealed to the housing with a
' nc udes Ba asl qu ick "twist-close" action.
1 l5 000 hours l0r conl nlous operati0n
" ncafdescenl amps shown above are A lype tlTrademark, Genera E ectric Company

\..\

---r

t-t(iFt
Series 2OOO Downlights I Anobrite@ Reflector

3t%u'o'" cei ing openrng

CoMPLETEu}llTcoNslsTsoFTwoNUMBERS:FRAlrtE-INKITANDREFLECToRTRI'll.
ORDER EACH NUMBER SEPARATELY.

STEP BAFFLE
Opt cal black lin sh on irrecision
ftted alumifum step baille
reduces glare. Cholce of "A" or
"R" amps. Anobrlleo reflector.
Suitab e for damp location.

[4ax. ceirlng ihlckness: 1"


0

'e
coilE
PrecisionJitted aluminum cone ln
choice of matte black, anodized
satin gold or anodlzed satin
clear finishes. Lamp ls set back
to shield it from view at normal
viewino angles. Anobrite@
reflector. Suitable for damp
location.

rvlax ceiling inickness: 1 '.

,.
,'{ =___=\ )\

10/Lr('Flr()l-ll=ltj'
accEssoRtEs:
FRA E-III KITS
I 2OO2P1 THERMALLy pRorEcrED FFAME-IN Krr 1Cl 1959 etaster nins
lnc udes: 13" mounting bars which can be extended to 27";
- 1956 3" 4'! o' qc rp)
ror or -rorrrq ^
o
mounting frame; socket and socket housing wired to junction l1a - odr ba s o T.Bo o
box; thermal protector to safeguard against overheating .c
resulting from improperly placed insulation; No. IBSF-] leads; ll ->^ . u Mo- r1q Ba
1964.ora >et ot 2 o
U.L. listed tor tlroLgh o,ancl' ci'cuit wrrrng.
r o. o, ot./e. to. po. I ori.o t'l 21 tr
-\\\ aons|L,cton
o 2OO2 NON-THEBMALLY pRorEcrED FRAN,IE-|N Ktr :
0)

for use in suspended ceilings. Same as 2002P1, but without a.\ q6l
o
1965 ,rOr eo oo So n6 iei .rq t r'
!
l' O'I , 6ttt'to .r.615 Jp O 1. o
thermal protector.
NOTE: The National Electrical Code requires access from above.
dbo.' 'i ' hed L.rr . E

oP
3E
.9&
c"
FNA E.II{ KIT 40w a.19 50w R.2()
}P
o:
) 2OO2P1 Thermatty Protected Oa)
-iliofrc r.rxir___- OO
a 2OO2 Non-Thermally Protected Fmleo6.oe','"x,
-dixc,re Hr ro IFc JBea"r Db OQ
o1)
6 a]s e{io
NEFLECTOR TNI I s i 2 1 i3 O -\F
.9=-
2OO5 vatte Black Bafite l0 1 t8
LAMPS. 4OW A,19
ITTULTIPLE UXITS f;G'
50w R-20
75W R.20
4 18
IJ

FFAIUIE.III KIT 40w a-tg '___


5('w R-20 '_-
stxorE uxtr
a 2OO2P1 Therma y Prorected nr ro I FL TBa-;l;
a 2OO2 Non'Thermally Protected FId I d ro ;hw
o l :zf: 'r@

REFLECTOB TRIM B--r5]4


2OO7 vane Btack cone -ro I e f 6'
2OO8 ,qnoOlzeO Satin Gold Cone ffULYIPLE UTIITS

2Ol O Anodized Satin Clear Con-.


LAMPS:40W A'19
50w R,20 2
75W R,20

For Guide to L ghting data, see page 63.


l- I (i t-t T() t_l t= ItJ / 11
Series lOOO Downlights I Alzak@and Anobritec' Reflectors

5'lrJ o^ceir no open nq

CO PLETE UN|T COr|SISIS OF TwO U BERS: FRAltE.lN KIT A D FEFLEGTOR TnI OR REI'ODELER KIT AxD REFIECTOR tRln'
ORDER ETCH NU BER SEPARATELY.

DEEP CONE
(A Lamp)
Maximum elflciency ow
br ghtness. Lamp is deepy
regressed in specu ar go d or
speau ar clear Azako Tef ector
-, i
'q' ' =ffii
$
precise y conto!red to prov de
38' sh elding ang e 10 amp and
i)
amp rnage in reflector prevent
q are Su tab e for damp ocaljon

1
Max ceiLng th ck.ess: )1"

I
STEP BAFFLE
Opt cal b ack lin sh on precision-
fltted alurr] nurf step baff e
reduces g are Choice of 'A" or

t&ffi-'
'R' amps. Anobrlte! ref ector.
Suitab e lor damp ocat on.

col{E
PrecisionJitted alumlnum cone in
choice of rnatte black, anodized
sat n go d or anodized satin
clear f nishes. Lamp is se1 back
to shie d it f rom vlew at noTma
viewing angles. Anobriteo
ref ector. Suitable for damp
location.

0
lvax celng lhlckness: l '^

'App es lo Frame n t only


12 / r-t(tt-rr()r-! r= lt-"
K
ACCESSOBIES FOR FRA E.III-KIN

e 1960 p aster nns


ut

ffi 1956 - a,, ;.n. no u


o
lv Lor
ar 'o g --ro . t'rg bd- o - Bd,
o
.9
includes: 13" mounting bars which can be extended to 27,,; .{t 1964. VoL,r nq Bd S' o - o
tr
\ -o,o,.6-e o,. o,r'a. oo<.or-g n _d
rnounting frame; socket and socket housinq wlred to lunction :,S.- aon<lrLral on %
bor: thermal oroteclo'ro sdfegua'd agatnsl ove'heali.tg : E
resulting from improperly placed nsulationt No. 18SF-1 leads; ^ 1965 Concealed
q..o-I Spr ne cle rng K t
ro. e,..o,,." !
anchor clips for existing ceilings. U.L. listed for through branch i , i.l 6d 0.6. o
c
" 6r r q
circuit wiring. "bo..
o loo2 NON-THERMALLY PROTECTED FRAME-lN Kll lor use !
in suspended ceit ngs. same as 1oo2p1, but without
thermal protector. G

RE ODELER KIT I(!


a looSPl FOR IRREGULAR CONDITIONS AND CEILINGS UP TO 2" rHtCK. tnctudesr Ftangetess mounting r ng;
retaining cl ps, snap{n socket cup wired to junct on box; thermal protector; No. 18SFl eads. U.L. I sted.
l,q
Oo)

o:
'9
Oa)
FRA E-II{ KIT loow A.tg o9
llOO2Pt Thermatly Protected Or!
op
O 1OO2 NonThermally Protected
o F-\-
RE ODEIER KIT
O lOOgPl Thermatty Protected .Fo
NEFLEdON TNl
lO45 Specutar cold Alzak
lO46 Specutar Clear Alzak

LAMPS: 10oW A-19

FRA E.I[ KIT 75W A.t 9'-___- 75W R.30 FL


t lOO2Pl Thermatty protected I Ftu
r., T tr
-_5rxor-e
uxir
ls*',",,
a lOO2 Non{hermally Protected , r,r ;;. ". rrQ9L
e ]sTa B'
RE ODELER KIT roltza l1
a {OOgPl
REFLE TOR
Thermaty Protected

TRII
"l, [r.
IllULYIPLE UNITS MULTIPLE UNITS

lOO5 laate Btack Baffte


I 435l,'i;
LAMPS: 75W A-19 / R-30 ,t
8'
." 9

Fn E-[a Krr 75W A.l9 ---


'-srxcfe 75W R-30 FL
alOO2P{ Thermalty protected
rixr 9tNCrE UNtt
I r,
r :cro-".""
ls", n, rolrr
nr Hl lGamDD
OIOO2 Non:Ihermalty protected Floo'
] | jo ;.." 6;
3 tli.
ro II ! I
eI Iii'
ra

rz I
REIODELEF KIT ro s I rl
t)lOOgPl Thermatty proreoed , J,lx 20
: ] r:
MULTIPLE UNITS MULTIPLE UNITS
REFIECIOR TRI
1OO7 laate Btack cone
Cl rc I rmt,"dn.
' ['0. a;]s,,,' p,
1OO8 nnoOizeo Satin cotd Cone a 125 lre
lOlO enooizeO Satin Ctear Cone o'lrl a
II6 Ls
LA[4PS: 75W Ang / R-30

For Guide to Light ng data, see page 63.


r- t(i FtT() t_ t t= t? / 13
Series 'IOOO Downlights I Anobrite(!) Reflector

$ti'u' o,^ce rnq open nq

CO PLETE UNIT CO SISIS OF TWO xU BERS: FRAltE.lX KIT AND REFLECTOR TRll{ OR RE ODELER KIT Ar{D nEFLECIOR TRlil.
ORDER EACH I'U BER SEPANATELY.

LOUVER
tvlatte black dre cast a um num
louver g ves effectlve brightness
control at a I po nts nc uding
lower wa of Anobrte'4 reilector
Louver snaps ln and but on
concea ed sprjngs for easy
relamping. Suitab e lor damp
ocation.
''I;FN\
Ma' cerlrng lhictness I '

PINHOLE
Sma I aperture down ght with
nner matte b aak baff e concea s
amp, g ves medium spread ol
ght reduces gare Aperture plate
snaps n and out on reta n ng
spr ngs lor easy re amp ng a_
Anobr te.r refeclor. Sultabe for
damp ocat on
I ts
i al,' -t
-l
Mdr ce inq th (r^ess r "'

TWIST-TITE
OPAL DIFFUSER
Cased opa glass gives
w despread, even uminat on.
Twist tite act on Temoves or
rep aces diffuser. Sturdy h nge
supports glass for qu ck. safe
relamping. Gasketed to prevenl
d rt and moisture lrom entering
fixture Su tab e for damp ocat on.

Max ce llng th ckness: 1" r

'Apples lo Frame ln K I on y

14 / L t (t Ft T(> t-t t= tr:'


t-

o
o
o
()
t
q
o
5
o

o o)
g' -
0)
o
o
ORDERINC A Lamp
!o
FNA E.IN KIT 75W A.t9 75W R.30 FL o o
I lOO2Pl sxcr.e uxii --
o
Thermally Protected
L,Irr 104;D;' o d
O lOO2
Fi
FFr lrL tr rrjl o o
Non-fhermally Protected \(o
I' 4 I 12 12 l6' o
o S
FE ODELER KIT I0 l0' 69'
a lOO3Pl Thermally Protected 12', 12', 4 l1
q)
ti lo
REFLECIOR ?RI
1006 t.latte Btack touver il'
..".i1;#
lL c 1 .
"
42.r16 "
LAMPS: 75W A-19 / R-30 rql
'15 r

FRA E.ltI KIT 75W A-19


}lOO2Pl Thermatly Protected ''-!i rn I rr
O 1OO2 Non-'Ihermally Protected
",,ii;-
8', 13
RE ODELER KIT t0 I8',
t lOOSPl Thermally Protected 12 23',

REFLEGIOR TRI
'l OlIvatte wnite

LAMPS: 75W A-19

FNA EIN KIT 75W A.r9


|lOO2Pi Thermally Protected ri i;
SIIIGLE UIIIT
I f -T+.:' na
H
a tOO2 NorFfhermally Protected too il 30 einie I oor
) I 2t',
RENODELER KIT 10' 2 ?,2',

tlOOgPl Thermally Protected I 4l'


ULTIPLE UNITS
REFI.ECIOR TNII
lO2l Opat Glass

l. LAi\4PS: 75W Al9

For Guide to Light ng data, see page 63.


t- t(t Ft?(> t- | t= tr-' / 15
Series 11OO Downlights I Alzak- Reflector
(Ei t%;'o ce nq open nq
"

CO PLETE UXIT CONSISiS OF TWO UI,BERS: FRAIIEJI KIT Al{D REFLECIOR tRll{ OR nE ODEIER KIT Al{D REFLECTOR TRl .

ORDEF EACH XU BER SEPARATEIY.

DEEP CONE
(A Lamp)
[,1ax raruta] eff c enay ow
br ghtness Lamp is deepy
r-ogressed n specLrar god or
specular c ear A zak'n ref ector
prec sely coftoured to prov de
38" shie d ng ang e lo amp and
amp image n refector prevent
g are Su table for damp locat on

Mat ce li.q lhickness 1" '

SHALLOW CONE
(A Lamp)
Compact down ght assures
efl c ency wth specu ar gold or
specu ar clear Azak"r rel ector
wh ch maxrm zes light outpul from
economica "A' amp. Fits n B "
loist construct on Su table for
damp location.

Ma, ceing ilrcl.ess l' '

DEEP CONE
(R & PAR Lamps)
Low brightness. Larnp s deeply
regressed n specular b ack
specu ar gold or specu ar c ear
Azak't ref eator which prevents
g are by assuring 40'shedng
angeto ampand amp mage n
rel ector. Up to 300W capab ity
Su tab e for damp location

Max ceilinq rhi.kness 1l;",

16 /t-t(tt-tT<)r-r r= r?' 'App es 1o Frame . Kl o.ry


ACCESSORIES FOR FRA E.IN.KIT
:
( Ir,'- e lg6l P aster nns

l-
& tto2Ft (O 1956 T B, i-. no' r ,p
FRA E.III KITS 6,x,,
- 1l I o d Ll-o nq^or1t-qod.lo lBdr
I ll02Pl pRorEcrED
1964 Za" Mountng Bars Sel oi 2.
THERI\,4ALLv
lncludes: 13" mounting bars which can be extended to 27,,,
mounting frame; socket and socket housing wited to junction
FFAN,4E-rN Ktr
<>:\ lO. e. ,o-na O,t o.to.pO<tro. .e n
conslflrclon -4
box,.thermal protector lo safeguard againsi overheating
resulting Irom improperly piaced insulation, No. lBSFJ-leads; 1965 ConceateO Sp ne Ce tino K
?
I

anchor clips for existing ceilings. U.L. listed for through branch De o4 ioT ce|nq runners uo to 21,,
above t n shed cerl nq
circuit wiring.
a ll02 NoN-THERI,4ALLy pRorEcrED FRAME-IN KIT for use in suspended ceilings.
Same as 1102p1, bul without
o
thermal protector. ()
o
REMODELER KIT
o
()llO3Pt FoR IRREGULAR coNDlrloNs AND cEtLtNGS up ro 2" THtcK. lnctudes; Ftangeless c
retaining c ips; snap{n socket cup wlred to junction box, thermat protecior;
No. tSsFl leads. u.L:. iisi;d.
--
mounring rng, 0
I(!

O)
o .E
ALamp '. R Lamp :'' PAR Lamp /' '! o
g o
o
PRA E-III KIT E
t'l t0zPl Thermalty prorected
!o O)
g
o)
OI IO2 tton+trerma y protected o
o
o
NE ODELEF KIT \(oE
allO3Pl Thermaly protected o
.9
N
BEFIECIOR TRI MULttPLE UI tS
o
l{45 Ct lo I o
1146
Specutar cotd Atzak
Specutar Clear Alzak
F@tander
"'' tr,+o:",' *
4 12. ) | 1a2

LAMPS: 100W A"ig


150W A-21

FNAf,E.Il{ KIT toow A.t 9


ll lO2Pl Therma y prorected sricLEutri-
Hr d lii
OllO2 Norrlnermally protected Be.tr 06
F@, l; ,n ,r"- ;;
,lruTt
RENODELEN KIT ro I 15 r'l
al lOgP{ Thermalty protected r: ro I ro
MIJLTIPLE UXITS
nEFttctoR Tnt
1143 Specular cotd Alzak Clr

ll44 Specutar Ctear Atzak


E
LAMPS: .IOOW A.19

CLEAR and GOLD BLACK CLEAR and GOI D


aIt O2Pl Therma y protected 300w R.40 FL
aii-
300w R.40 sP ,?qr-PA!.38I-L
a llO2 Non-Thermalty --Hl hf F. fBam DE -Hi ro
SIiIGLE I"Il
Fw lrn .;o.,,@- Frw Ix
I F! tsam D*
rLr r6;e rm-''
8r076
-srNcLE lS 1,u"T. a
.r!r: lLs7 II t2. Lta'i L?
REFLECTOB TFI | :o I ro .ta to ) a -..
ll49 Specutar Btack Atzak UNITS MULIIPLE UNIIS
f l5O Specutar cotd Atzak
I l5l Specutar Ctear Atzak q
T 51 I ztt 19,)
96 s l-:s J r:+
87

For Guide to Lighting data, see page 63. !-r<tFf T()t_t t=al" I 17
Series 'l'lOO Downlights , Anobrite'r Reflector

Cit%;'0" ce ng opening

CO PLETE Ul{lT COI{S|3IS OF TWO U]{BERST FRAIllEJl{ KIT Al{D REFLECTOR TRI OR RE]IIODELER KIT Al{D REFLECTOR TRlil.
ORDER EACH }IUI{BER SEPARATELY.

STEP BAFFLE
Optca black finlsh on precis on-
fitted aluminum step baffle
reduces glare. Adjustable socket
ho der perrnits use of 'A', "R'1
''PAR" or "ER" lamps.
Anobriteo rel ector N,4atch ng
Adjustable and Wa lWasher (page
40); Low-Voltage Adjustable (page
39). Sultable for damp location

Max. ce ng thck.ess: I " "

coilE
PrecisionJitted aluminum cone in
cho ce of matte b ack, anodized
satin go d or anod zed satin clear
finishes. Lamp is set back 10
shield it f rom v ew at normal
viewing ang es. Anobrite@
ref lector. Matching Adjustable
(page 40); Low Vo tage Adlustab e
(page 39). Suitab e for damp
location

Max ce ng llr ck.ess i"

LOUVER
Matle biack d e.casl a um futn
louver g ves eflect ve br !lhtness
contro at a po nls, inc ud nq
o\,\,eT !\,a of Anobrite' refector
Louver snaps n and oLrt on
concealed spr ngs for easy
re amp ng Adlustable socket
ho der Su 1ab e lor darnp ocat on

6'1,,

Max celng th ckness 1"'


'App cs 10 Frame ln ( I on Y
18 / r-t(t FtT() t-t t= t?
-

Q
o
o
(,
()
E
%
E
!
o

\ c')
o.=
q)
g'q
PAR Lamp Eo
!.9
oA
FRAHE-IX KIT
lO2Pl Thermally protected
__ t 50w a-21
stNcLE uiir
15OW
'_
PAR.3A FL
uirr-"_
75W ER-3() o-
O I fl lo F Thr rtrrl
stNcLE
od
o-
Ii O llO2 tton-fnermatty Protected Fo! , i.-;,

FE ODELER KIT Il"


i :r l
rr i
ru
rr o rtt\
!,F
ti l)l lO3Pl Il

REFIECTOR TRI
Thermaly protected 12 l1
MULTTPLE uNrra
17

UITIPLE UIIITS
5i = 05
;(o
r rmr,,*t: -
llO5 'l: T1,,,a.,1..,
ar lmrtnr.! cl: ri
vatte Btack Bafite Li'I P
r,,.
4 1) tl 49889
LAMPS: 75W R-30 / ER-30
6't32 6144)44]
100w A-19
e' re Il2irs
H- '150W A-21
/ R-40 / PAR_38 8 -l-

FRA E.II{ KIT l50w A.2r _t50w R.40 FL IsOW


_ PAR.38- FL 75W ER.3()
siior-e rinn
- _

I I lO2Pl Thermallv Protected Nl ro


SINGLE UNII
I rL lL;nE rr oI.L lsramr
srr,tcLe uN|T
riol- rr lB;m D.
a I l02 Non-Thermatty Protected Fdr ,,,1..-*; Fmr rm, l;, icre rrooi
" h,,n""
8 e +llo e [s;
1a'llrro
21 10
RE ODELER KIT ro
rz IL 16
' I ro
l0' tl l3 u tBl4,
allOgPl Thermaly protecred 7 17',
l? 14eI9l
REFLECIOR TRI MULTIPLE UNITS i.UITIPLE UXIYS
llo? laare Black cone ar r I h,ir.,d.a ir' I I r.,,,.:rdri cr ril rorr,.n' o.
llOS enoOizeo Satin cotd Cone ,,' t. R r-
L r c '" L,l" :,r+m
1l lO r loolen
nnoOizeO Satin Ctear Cone

LAMPS: 75W R-30 / ER-30, 100W A-19


;1.1";
u ,, I ,.
4dd71
e J:c)1 :z
P : I re
6144 40
'150W A-21 / R40 / PAR-38 I

FRA E.IT{ KIT {50w A.21


a11O2P1 Thermalty prorected UIIIT
lB,1ti..
O I lO2 non+ermally protected

RE ODELER KIT
lo-
ll
a l lOSPi Therma y protected
l

REFLECNOB TNI
1106 uatte Btack Louver
LAMPS: 75W R-30
100w A-19
'150W A-21 / R40
/ PAR-38

For Guide to L ghling da1a, see page 63. r- r(ir.rT()t_t t= t?" / 1 I


ggyiss l'l OO Downlights I Anobrite'o Reflector

6ulr;:o^ce nq; openins

LENSLITE
Fresnel lens regressed n whte
bezel spreads ght everY gves
hqh ellciefcy low brghtness
Anobr te" rel ector TorsiQnt ie
sprjngs a low trim assemb y to be
pu ed down lroaar any
s de for
easy ma ntenance Su lable 10r
dan-rp ocal on

l_

Mai cer ng lhck.ess 111"'

ALBALITE DIFFUSER
ture white A bal te qlass d fiuser
regressed n wh te beze . prov des
c eaf crlsp look Anobrte!
ref ector Tors ont te spr ngs a ow
trrn assemby to be pu ed down
from any s de lor easy
malntenance. Su table lor darnP
ocal on

Max ce ng lh ckoess l lll '


fl,
TWIST.TITE
OPAL DIFFUSER
Cased opa g ass gves
wdespread, even illurn natron.
Twisl.tite act on removes or
rep aces d lfuser Sturdy h nge
supporls g ass for quick, safe
relamping Gaskeled to prevent
dlrl and mo sture from enterinq
I xture Suilab e for damp ocation

Max .eil.q th ckness 1;t" '

RECESSED
OPALEX* *
Trans ucent white, ifiect on
mo ded dilluser ol shatterProoi
Lexant gves \,ri despread even 6
i umnation deal for rouqh g
setv ce areas. Contoured, sem
o oss white Tef ector assures
ax mum lght distr but on Tw sl
ock re arnping Su tab e lor damp
locat of. I
L
Tl aij-"mar( Ger-"ra EEcl . Corr!:1.!
',J S Parerr N! I rl,lll lll5 lllar ceilira thickness I "'
'App es 1o Frame . K I o.y
20 / t- | (t Ft T(> l-l l= l?'
CO PIETE UNIT Cotlslstll OF TWO NU]T|BERST FFAitE.tN KtT A D REFLECTOR TRtit
OR RE ODELER KIT AND REFLECIIOR TRI . ONDER EACH UiIBER SEPARATEIY.

FRA E.ITI KIT 100w A.19 .-


SNGLE UNII
I I lO2Pl Thermatty protected
l''l' T! I s!! !c o
O I I O2 t'ton:rnerma y protected rw I r0 .bore roor
sa tr f 11- o
o
RE ODELER KIT 10' 7 14' o
Ol lOgPt Thermally prorected tz- f al:a E
n
MULTIPLE UNITS
REFI.ECTON TFI SF = 15 E
1126 vatte wnire oo
c
LAlvlPS: 100W A-19
\ol
o=
-c "t
El6

FF NE.III KIT 't00w A.19


t
o= ._-

11O2Pl Thermatty protected - --NGLE.Ni o3


t)
- o;
o;
O I 102 Non-Ttrermalty Protected
8', 11', ;.(o
RE ODEIEN KlT lo; oS
o-
;o
16',
t) I l0gPl Thermalty protecred 12', zo-
NlULTIPLE UNITS
REFLES'OR TRI
I 128 l,tatte Wnite
27
LAMPS: 10oW A-19
12

FRA EIl{ KIT t00w A.19


t llO2Pl Thermalty protected I Fr
FL Lo
SINGLE UNIT

O I lO2 t'ton+nermatty Protected F@ , J -aboo


-8.;D;
u@
8
l BT16
NETDELEIi KIT 10'15121
It I O3Pl Thermaty Protected 12' \ 3 27,
MULTIPLE UNITS
FEFLECIOR TNl
Clr l. Ftrl.rndes
1121 opat ctass .' ]L,o" F' 15.,r B'
a'L13 l 1r
LAN.4PS: 100W Al9 6 l 1e L 14
8 11 8

FFA E.Il{ KIT 100w A.19


SINGLE IINIT
a{ lO2Pl Thermatry protected N o I Filsm D,
O 1102 lorrfhermally
f0! r,0 abo@ fbo
Protected

FE ODELEN KlT 41',


()l logPl Thermalty Protected 52i

REFLECR'R TRIM
I l4l opat Lexan
LAMPS: 100W A-19

For Guide to Lightlng data, see page 63.


l- r(t FtT<>t-t t= t?'/ 21
Series 1'l OO Downlights , Compact Fluoreseent*
t%;;|"
6 ceirins openins

STEP BAFFLE
Prec sionJitted aluminum step
baifle lor use with energy-
efficient, ong- fe 9W PL
fluorescent amps Optical b ack
finish. reduces olare. Anobrite@
reflector. Match6s appearance of
incandescent Slep Baff e
Downlighls (page 1B). Suitab e for
damp ocation

Max ce ng tnl.kness 1'.

CONE
Prec sionJitted a uminum cone
for use with energyff cient,
ong-liie 9W PL fluorescent
lamps. Choice of anod zed satin
oold or anodlzed sat n c ear
iinishes Anobr teo reflector.
N.4atches appearance of
incandescent Cone Downl ghts
(page 1B). Suitable for damp
location

Max ceili.g thickfess: 1'

FU'SH OPALEX
Energylficient illuminat on with
diffuser of v rtualy unbreakable
Lexant (polycarbonate). Accepts
long- ife 9W PL f uorescent
lamps Easy lw st-locl relamping.
Srritab e lor damo ocatlon.

Mz .e ng lh.tness l' '

DROPPED OPALEX
Energyfficient lllumlnation with
gasketed dlffuser of virtua ly
unbreakable Lexant
(polycarbonate) lMay be used as
shower light. Accepts long- ife
9W PL lluorescent amps. Easy
twisllock relamplng. Sultable for
damp location.

'See page 27 lor manLrJaclurers oi


compacl I uorescent amps
tlrademark General Eleclric Company

Nlax ce ln! Ihickness 1"'


'Apo es ro Frame.n K I ony
22 / t- r (t Flr() l- l l= l?'
CoMPLETE UNIT CO SISTS oF TwO tlu BER$r FRA EJN KIT AllD REFLECTOR TR|M OR
REFLECTOR TRIM. ORDER EACH I{U]S8ER SEPARATELY. RE oDELER KtT AND

FFAHE-I KIT 2.PL 9W *Slaning Temperature


PL-g Lamp: 25"F.
o
lllO2Pl Thermally protected SINGLE U IT
o
o
Ol l02 Non-tnermalty protected o
o
E
o
G
c
E
o
o
NOTE: Total npul watls=25; iotal amps =.36

t'o
Ea,
]=
o=
FFAME.III KIT 2.PL 9W oii
SINGLE U{IT o.n
Itl02Pl Thermaity prorecred rll Lo rL l;.;i.it; On
Oi l02 Non-Tnermally protected
o;i
,'lrl: ;o
oi

ar
I LrFl \ r
r :, I

ll
NOTE: Toia lnput wails=25; "1

FRANE.III KIT 2.PL 9W


SINGLE UNIT
r)llO2Pl Thermaly protected r l.
O I l02 ruon-Tnermalty protected
e] | .l,"
RE
atlOSPl
ODELER KIT
Thermaly protected
,1,'l-
) 2
MULTIPLE UNITS
REFLECTOR TRI LAMPS (F Lroresceni) ir, r I :,.n"N
1184 opat Lexan (2 tight) PL-9
L *'
r]r.]r l

NOTF -ora ro n $dtrs=25 rota' d-nps L, 175


= 36.
8l

FRANE.III KIT
a l lO2Pl Thermally Proteoed
O I lO2 Non:hermatty protected

BE ODELEN KIT
r}ltO3Pl Thermatty protected

REFLECTIOR TRIiI LAMPS (Fluoresceni)


1188 Opat Lexan (2 tisht) PL.9

NOTE: Tolal inpli watts=25i tolat amps.= 36.

For Guide to Lghllng da1a. see page 63. rf :'7! ..ri! h:l_.,,,
f- I (i t.f T()t_ | I=,r-, 123
Series 12OO Downlights / Anobrite@ Reflector

9"lr[' ot^cei ns open ng


I i i

COMPLETE UNIT CONSISTS OF TWO NUMBERS: FRAME.IN KIT AND REFLECTOR TRIM.
ORDER EACH NUMBER SEPARATELY.

LEl{SLITE
Fresnel lens regressed in wh ie
bezel, spreads lght even y, g ves
high effjaiency low brjghtness.
Anobrteo ref ector Tors ontlte
spr ngs allow tr m assemlt y to be
pLr ed down lrorar any side for
easy ma ntenance. Suitab e for
damp ocat on.

ALBALITE DIFFUSER
Pure wh te A ba ite g ass d ffuser
regressed n softy i umlnated
wh te bezel, provdes c ean. crisp
ook. Anobr ter4 reflector LENSLITE ALBAL TE
Tors ontite spr ngs a low trlm DIFFUSEF
assemb y to be pu ed down lrom
any s de lor easy maintenafce
Su tab e lor damp ocation.
Max. ceiline thickness: 1"
N.
TWIST-TITE
OPAL DIFFUSER
Cased opa g ass gves
w despread, even um nation.
Twst tle action Temoves or
reolaces d ffuser. Sturdy h fqe
supports g ass for qu ck, safe
re amplng. Gasketed to prevenl
d rt and moisture lrom enter ng
fixture. Su tab e lor damp locat on

Max ceilng rhkness 1

RECESSED
OPALEX*
Translucent white, iniection-
molded diffuser of shatterproof
Lexant q ves widesplead, even
illumination. ldea ior rough
service areas. Contoured. sem -
o oss white reflector assures
irarimum iqhl d stribution Twist
lock relamp ng. Su table lor
damp ocalion.

iTrademark. Genera E eclr. Compa.y


'U S Paleft N0 3.840.735
lYlax. ceillng Ihicknlss: 1".

24 / t- | (i FtT() t- | t= t?'
. lccEstoRrEs FoR FRA E.III.KI}

IQ I
)
FRAHE.IN KITS t<_ -t 1962 aster Rrnq
__ P
12O2P1 THERMALTy pRorEcrED FRAME- N Ktr
nc udesr 13" moufting bars which can be extended to 27,, (,. 1956 o
o . ",:i o .:o
r
mounting frame, socket and socket hous ng wired to junction l/ o B"
o
box: thermal proteclor to safeguard against overheating '1964 :o
resulting from irnproper y placed insulaton; No. IBSFt leads iJL tr'iolnl na Bars Sel ot 2 o
(,
anchor clips for exisling ce lngs. U.L. lsted for through brafch ./+-: o"' oo :
aolMlLraTLrrr qr
c rcuit wiring. E
a 1202 NoN-THERN/ALLY PROTECTED FRAME-|N Klr
1965 .. .o. . s. o
'l 'aA o i .. .po .:
lor use in suspended ceil ngs. SanTe as 1202P1, but wthout abovq Irn sh_ocl ce ng
thermal protector !
o

ORDERING A Lamp A Lamp oP


.c-
FRA IE.IN KIT IEI{SLITE ALBALITE DIFFUSER
.93
a 12O2P1 Thermatty Proiecred 150W A.21
uNh'-...-
150W A.21
a 1202 Non-Thermaily Protected
-SiNGLE
S]NGLE
I , FLIF-n
UNIT
- r,
'P
Oo
r rh..p Ioor OO
LE}ISLITE a'] zs
B 2r ]I ri'
tt, o!
65
N.s
NEFLECTOR TRITII
'..t{i 1A p 16' F\(g
l, -\F
1226 tr,,tatte wnite o,
iTULTIPLE UNITS
=-
ALBALITE DIFFUSER
BEFLECTON TRIIU
,BO
1228 vatte wnite 4 145 91

LAMPS: 150W A-21


6', 47 4A
23

FRAME.I KIT
) 12O2P1 Thernraity proiected
O 1202 Non-Therroally Protected
8' rr I ro
NEFLECTOR TRIM
l0' 6 21
l22l opal ctass 12427
MULTIPLE UNITS
LAMPS: 150W A-21 sF = 13

F;I:rnir F"
4166 45

-'B', lzs-p
16 11

FRAIIE.IT{ KIT 150W A.2t


| 12o2P1 Thermalty Prorected SINGLE UNIT
F. l:q!:.
a 1202 Non-Thermallv Protecl-.d
8
REFLECTON TRI'$ ro
1241 opa Lexan 12',

.@TAMPS 150w A-21


.r :i I rd.ildr
89
40 27
22 15

For Guide to Light ng data, see page 63.


t-t(tFf T()t_t !=tt: I 25
Series 160O and 19OO Downlights , Compact Fluorescent

5'lr" x9tlo" / 9ulo" x9%""",,,nn opening


MOUNTING BAR(S)
a For wood joist or suspended
ACCURATE LEVELING
. Self-leveling slots in housing
JUNCTION BOX
. Easily accessible f-
ceilings; extends vp Io 27". automatically adjust housing till trim a Saves time and expensei ground
a Ny'aximurn strenqth prevents flange fits flush against ceiling. wire and knock-outs.
sagging. . Ceiling thickness = 1" max. . Approved for Through Wiring (2
. Friction grip holds bar in place. in-2 ou1, 60"C).
. 20" Mounting Bar Extenders-Set . U.L. listed for Damp Locations.
of 2 (Accessory No. 1964) for off-
cenler positioning of housing
between ioists spaced up to 24".
. Concealed Spline Ceiling Kit
(Accessory No. 1965) for use with
concealed ceiling runners.
a T.Bar Anchor Clips {Accessory No.
1956) anchor mountinq bars to
T.Bars.

V
{

4
SHALLOW 3%"
DEEP HOUSING
a Permits
insiallation
in ceilinos
or walls.

TRIM TABS DIFFUSER TBIM FLANGE


a Tabs on trim flange snap into a Translucent white acrylic. Snaps in . lnjeciion-molded Lexant.
holes in housing, for fast installaiion. and out of trim flange for easy

r
relamping.

: Iral'jcnllr( Ge.eral Ee.l,,. aor'lr;:rv

26/l-l(}t-tT()t-il=l?'
I
FAST INSTALLATION
cElLn{G WALL

o
o
tt
o
o
l602 hOUStNG tnc,Ldes RecrarqJtar hoJsino o
o
'o. IPL-'3 tamp: .rolrnt ng bars wn ci e*reno 1o"27,,; l|-
ba/ast,,L.tclion bor. Approveo for throLgh o,anc. o g
clrcutl w nno fi
o 4)
ro :O
Frame-ln Frame-ln -{
Naii mount ng bars to joists,
I ning up bottom edges oi
bars with bottom of lolsts.
Nail mountifg bars to studs,
lining up edges ol bars w th
edges of studs Housing
o
o
o
oX
Housing projects below projects beyond linished wall
linished ceiling line llne.
!o ;{

9"
o
o
o
o
o
;s
Wire.ln
Knock oul K.O. in junction
box. Altach supply w r ng and
Wire.ln
Knock out K O. in junct on
box Attacll supply wiring and
^19_^O2
PL-13
F,OUS|\G tnctudes: SqLare hous,,rg for 2
la^1os. moJntt']gba's whiih extero to-27,,;
ballasls iunct,ol bo\ ADo'oved br r.ough D artcr
circurl wrTtng
(!
o
o
rt}
oX
connecl to lixture leads. connecl lo lixlure leads
o
ACGESSORIES:
q)
>
1956 f ear Anchor C ips
ro,
o
o u)
IJ' ".r-o._o - o -.. q o" to _ 8".
!964 zo'Mountng Bars Se1 ot 2
=>\ L
o, ., .6^. O,,..6.to. oo. .o. .g
conslruc!on
,l

I
1965
Glose-ln Close.l n
l

? Sa'
Concea eC Sptne

abo/e f nrsh-"d .e no
Ce nc l.'/1
o.a Lo .,.C._ .. _o ro
install plaslerboard or other lnstall piasterboa rd or other
dry type ceil ng dry type wal .

llOTEr The P- ,arro s"Tr-


oV Nonh Are'can pt-i,rps.
FqL vale_'I la-os are. Twin-Tuoe oy Sy varra,
General Eleclr c and Osram

For 277v.. consu 1 laclory.

Snap-lnlPush-Up Snap.lnrPush-ln
Align tabs on trim iange with Align tabs on trim f ange w th
holes n housing Sprlfg clips holes in housing. Spring cllps
permit houslng to be pushed permlt housing to be pushed
up untll trim llange s snug to in until tr m llanqe is snuq to
ce ling, ho d rt securely in wall, hold i1 sbcurely in
place. place.

Enclose
.:$
Enclose
Push dlffuser into trlm fiange Push diifuser into lrim flafge
so lhat atches snap into so that atches snap into
retaining qroove retaininq qroove.

t-t(tFt?() t_| t=ar: 1 27


Series 16OO and tgOO Downlights I Compact Fluorescent

St4" x9tlo" / 9tlo" x9tlo""",ns openins

FLUSH DIFFUSER
Translucent white acry ic d ffuser
gLves widespread. even ll uminat on
Shallow housng can be recessed n
3?s" deep construclon. Fast
relampinq w th snaelock mountlnq
which permits dllfuser to be
snaooed on and oli tr rn flange.
Ce linq or wall mountlng Suilable
lor damp location

DROPPED DIFFUSER
Sha low, 1" deep trans ucent white
acrv c ditfuser sPreads soil ight
over a wide area gives a bulllin
look. Housng can be recessed in
3'l " deeo construction. Fasl
rtiiamprnq with snaplock mount ng
which perm ts difluser to be
snapped on and olf trim f ange.
Ceil ng or wall mounting. Suitable
for damp location

FU'SH DIFFUSER
Tians ucent whlte acrvlic d ffuser
oives wldespread, ev-;n lllum nat on.
Shalow hous nq can be recessed in
31"" deeo construction Fast
reiamp rig with snap-lock mount ng
which perm 1s diffuser to be
snapped on and olt lrim flange.
Ceiling or wa I mounting. Suitable
for damp location

DROPPED DIFFUSER
Sha low, 1" deep translucent whlte
acry ic d lfuser spreads soft lighl
over a wide area. qives a bu lt- n
look. Housinq can be recessed n
3?s" deep construction. Fast
re amprng with snap-locL mounting
which permlts difluser to be
snapped on and off trim f ange.
Ce ling or wall rnounting Suitable
for damp location

28 / r-r(rFrT<> r-r r= l?'


COMPLETE Ul{lT COI{SISTS OF TWO NUMBERS; HOUSTNG AND DTFFUSER TR|M. E
ORDER EACH NUMBER SEPARATELY. o
o
o P
o
-
ID
o
o
E o)
o q
HOUSINC l-PL t 3W t!
1602 -- -srncre nxrr'' __-_ o a)
"rf F rs, rf c
o ;{
o
DIFFUSER TRIM
l6O7 opat ecryiic
s
' -ll I I r''
10 r I lr
+ [r"
I
o oX
IANTPS: 1 -PL-l 3 Fluorescent MULTIPLE UNITS
g
NOTEr Tolal input walts=18
toial arnps.: 30.
E
]o -s
lVar. ce ting lhickness: j,
a
o
o
o
o
o
! ;s
FRAIIIIE.IN KIT .t.PL I 3W
o
o
o
c
fi
oX
16(}2 SINGLE UNIT
o
DIFFUSER TRI'II
'l I ' ic;i;n () >e
16O8 opal Acry lc
I
9
o
o u)
I tr'
LAllPSi 1-PL-13 Fluorescent
_fotal
NOTE: input wa s=18;
lotal amps.=.30.

2A
Ma^ cel ing th c[ness r '
I

HOUSING 2-pL I 3W __
srxofelxri
q Cerl'1gOoening Certino Ooenino 1902 F l; +i rri
e,. sq -- - s; sq __- -l F, l,t, r, -
_l IXFFUSER TRIM 8 | e I 16
11 I
l907 Opal Acrylic "Ir
io I ,t
f-t_Jt- LAMPST 2-PL-13 Fluorescent
I I rr
- 8i So. 8,'Sq MI',LTIPLE UNIT6
. 9, sq 9" sq.
NOTE: Total input walis=35;
lotal amps.=.60.
- r0.. so. l0 , Sq.

,Vax. ce ling lhickness: 1 .

HOUSI G 2.PL 1 3W
Ceilinq Opening 19()2
F 9L" sq. '. l.n--
IXFFUSER TRIf,I 9 T3
l9O8 opal Acrylic 723
LANiIPS: 2-PL-13 Fluorescent
.f.:o'
NOTE] Total input watls=35
lotal amps.=.60.

Md. ceitng ihickness: t .

'Si:rl r! leiD.i!lrr!r !L l: Larrr 32'F


For Guide to Light ng dala, see page 63.
r- r (t Fr T() r- I t= tr-' / 29
ACCENT LIGHTING
Accent lighting can be the rnost Standard Voltage Lighting Low Voltage Lighting
flexlble, most effective tool for The standard line voltage lamps Low voltage lighting offers many
achievino creative control in most commonly used are the advantages as compared to
lighting. reflectorized, long'lif e "R" and standard voltage lighting: a more
Easily adlustable, both
horizontally and vert ically, accent
lights direct the light so that it
"PAF" types in wattages from 30W
1o 300W. These lamps are ower in
cost but generally produce a wider,
accurate control and broader
selection of bean.r spreads; a
whiter, briohter liahi that improves
tr
enhances me'cha1d ise, d'ama Iizes less tightly controlled light beam color rendition; !ess radiated heat:
art obiects and prized possessions. and offer a smaller selection of more iniensity per watt; and lower
Adiustable accent lights can also bea'n spreads than low volrage overall operating costs.
provide down lighting from sloped lamps. Low voltage lamps have smaller,
ceilin g s. Standard voltage fixtures are also more compact f ilaments than
These fixtures accept a wide more economical because they do standard voltage lamps, enabling
range oi incandescent lamps, in a not require special operat ino them to behave as true "point
choice of intensities and beam equipment such as the sources" which precisely gather
spreads. some fixt ures are translormers required by low and direct light output.
designed ior operai ion wilh voltage units to reduce line voltage This accurate control produces a
standard line voltage Iamps. oihers (120v.) to operating levels (5.5v. or very tight, well-defined beam that
for operaiion with low voltage 12v .\. illuminates the target without
lamps. Among the newer standard waste{ul or distracting spill light...
voltage lamps are 90W PAF-38 and creates the sharp contrasts of
types, which have an inner highliqht and shadow needed io
tungsien-halogen capsu Ie des ig ned focus attention on the target.
to provide increased light output Low voltage lamps are very
wrth'educed energy co']su mp iion. energy-ef{ective since they produce
These lamps provide as much more beam intensity per watt than
usable tight as a conventional 150W standard voltage lamps. Very little
flood or spol and retain their initial light is wasted, so that less wattage
brig htness throughout their life. can be used to do a specific
lighting job. ..or, the same wattage
can be used to do a more ellecttve-;i
elfective
iqb. .. ., .,..,3

lvlB-l6. 12v

PAR'36, 5.5v or 12v.

st
Lower wattage con su m pt iof Lamp color ternperatures of both
generates econorny of operal on. The PAR.36 Lamp
the tungsten-halogen Ny' R-16 and (5,5v. or 1 2v,)
W th lower e ectrica loads. overa l PAR-36 ow voltage larnps (2950' to
operat ng costs are reduced, as are 3050' Kt for N,4F-l6 and 2550" to The most versatile of a I low voltaoe
'he in ial rslaila lio'l, oS L5 . ..,t-,]ce lamps. the PAF-36 has a range of "
:lf smaller distr bution panel boards
2600' Kt for PAR.36) are generalty
higher than those of standarcl beam spreads and intensities from
very narrow to very w;de.
and fewer swttches and breakers vo taoe lamps.
are required. Add it ionally, lower A hemispherical shie d inside the
wattages reduce the radiated heat The MR-16 Lamp 112v.) la-p cove's rf a'i are.t. l.dppir.g
from the lamp. savine on air lhe q-16
M ldmp o rec ls d p'ec sa stra\ iol-[ i'lstaao ol a.lowirq rl ro
cond tioning costs. bearn that is cool, sharp and
spi I out afd cause q are. Sinte the
lamp itself provides excellent g are
capable of providing excellent co or contro and has verv lit e
The Choice 'prd ior. Bea- range i.o-
The low voltage lamps most ^iotrs ratq.
'1arrow lo wide. Watraees brightness outside ihe beam angle,
commonlV used todav are th-. f rom 20W to 75W
lghting fixtures require litIe
\lF 6 iV--ll-Virro ' Fef recror. 2 Thp \,4R-16 has a ^ L l-n llol
additional sh eld ng.
The lower the voltaae. the
ord-nete r ard rhe PAl36 (pardborr. laceted reflector with a dlchroic
Aium nized Fef ector 4',', sma ler the lamp f lament ancl, the
coating which reflects the liaht out
dran'ere'r. Bolhrdmp5 qtvp a ]1/ide the front. while allowing heai to smal er the f lament, the oreater the
choice of rntensittes and beam pass through the back of the lamp. opI ual co]tro For ^\d-lt p, 5.5v
spreads. PAF-36 larps o'o.ecl e.([emery
The reduced heat in the ight beam narrow "pin spot'beams only 1.5.
The color of a light source is dssJ es coo opetdrio.']- ioea fot 'r w drl-- ioeal 'o. p'rDoinl 19
irdicdleo by irs co'or r6n pe aru -; ig ht ng per shables.
iie higl-ct the color rempe'atJ d, Sma I ldroe S al otq o Sta''t.es.
Sealed into the reflector is a t ny.
the whiter the tight. The hiqh hiql--oertor-"rce Lurg5rer l-droger
fi ament temperatures of low amp wh ch emil: an unusuallV Where
volrdoe,amos orov.oe a very wnite, white, briqht iqht rich in blue Accent Lighting
bnght light which cuts throuoh [ores -e,, celle1t [o'erha.l.i1a the Can be Used
arnbient liahtto focus on the" sparh e of crystal and lewe ry. lT nuseJ-s ato a leaileries r
targeted objects. aJdiloriums. to h iqh riql-'t specrfic
areas wilh ptnspots i.lqra leo i1
high ceilinas.
ln hotel or bank lobbies. lo- focus
aitention on seating areas. planters
and wati d,sp rays.
In stores and showrooms, to
enhance the lexture. color or
sparh le of me.chand;se.
And,;n the home. to acce, table
settings, multiply the sparkie bf fine
ut;/ crystal. h igh ligh r pr,zed possessions
and create a specjal ambience...
) with precisely controlled bearns of
lig ht.
Accent ligh ting: A dramattc
techn ique for bringing crealive
control to the new artistry in
lig ht ing. "

t <-e.EvE-r ^,,4,ee:,a
P/,^/ 5PD7<'
fAous D^/ TApaE 7-s-
,,4 7 la),/o Z),sr,a NC E s.
Seriec 2OOO Accent Lights, illR.l6 Low Yoltage

$"lri' dia ceitins openins


a
EASY RELAMPING
Spr ng tension ci ps on
lampholder assembly securely
Suplorl arfp and protective glass.
,r low fast snap oul snrJp./r re amf nQ.

FITS SHALLOW -o.r E- -\ , ";r' spr\a


PLENUMS
a Compact. riOid, die- .\a- ./ c LtP

formed aluminum.
. Overall height of
MOUNTING BAR(S) GLARE CONTROL
housing. only 5 1./4 ".
promotes {lexibility of
un.tr,-'
LAIIP'
-r/,/-/.'. ,
6-
..--
Sgie
)t 4tD
rclie
a Extends up lo 27". a Yoke mountinQ insiallaiion where F/lrai
a Maximum strength moves lamp back ceiling depths are
prevents sagqing. when tilted. allows full limlted.
a Friction grip holds beam to pass through
bar in piace. small round pinhole BUILT.IN
aperture- No glare, no SELECTOR
distracting palterns on swlTcH DUAL OUTPUT THERMALLY
the ceillng. a Selects 20W or TRANSFORMER PBOTECTED
50W-75W lamp a Supplies proper . Bu ilt,in thermal
operation. voltage to insure proieclor safeguards
rated lamp Jiie against overheatlng
resu lting from
JUNCTION BOX improperlV placed
a Saves lime and ins u lat ion.
expense: built,in
cable clamp, grou nd
wire. pry-out knock-
outs and safety-
edged covers.
a U.L. listed for
Through Wiring (4 in.
4 out-75'C) or End
of Fun {60"C).
a u. L. listed for
Damp Locations.

CONSISTENTLY
ACCURATE
AIMING
MOUNTING PLATE WDE CHOICE OF CLEAN a Locking screws
a Fiveted to housing APERTURES APPEARANCE NOTE: assure that lamp
for strengih and .Black Step Baifle; . M inimum-width The Nationai Electrical position is not
durability. Matte Elack Cone, flange ior c lean. neai Code requires access disturbed durino
a Treated to resist Satin Goid Cone: lnstallation. above ceiling. relam ping.
corrosion. Satin Clear Ccne.
a For plaster .Matte White
ceiljngs, use Plaster FULLY ADJUSTABLE
Pinhole (shown) a Lampholder
Ring (Accessory and Slot Aperture.
No. 1959). assembly rotales 358"
VERTICAL ANGLES horizontally. adjusts
a For fixtures used verlicaiiy 0" to 40",
with Housing permitiing fixiure to
"i-.--. 2052,
be used as either an
vertical angles are
HORIZONTAL adjusted by inserting adjustable acceni
A9JUSTMENT screwdriver and light or a downlight.
a For fixlures used sliding the lampholder
with Housing 2052 . in the adjustment slot. WIDE CHOICE OF
horizontal adjustment ihen tightening the WATTAGES AND
is lixed by rotating locking screw. Built'in BEAM SPREADS
lampholder lo desired
pos'tion, then
detent looks . Up to 75W
lampholder in capability.
lightening the locking downlight position. a Beam spreads
screw. '!rom very narrow to
very wide,
NOTE: LOW VOLTAGE FIXTURES should be dimmed only with special
dimmers lntended tor thal p!.pose. Use Lighlolier Precision lV Scenist,
ot Lyie-ode, or eqLr!alerr p.odrcrs by olae s o, \a rabe aLlo
I dI !ro'^ ers o, e ecrro-l c d:r .nF's i.tended ro{ Jse wtlh lo,^ vortaoe
T,\lJres

32i t-t('r-tr()t-tl:trj
HOUStNcS

ACCESSORTES:
.2052 Color Filters
''
d.
ADJUSTABLE HoUSING THEBMALLY PBoTECTED
d_-1.
,d_'ro o^ o.
" ' q nOLa rqod F,e,O_na
, . ."" o: e
-t, - f-
-l
do oo. d .o o ,p,
1B<r' - o '.^o OO6,O. t' ^. .60 , .. O,...O.q,o 7551 Blle o
C rau I w r nq t552 Red o
7553 Lavender
7554 Lght creen g6
7555 Light Blue o
7556 Amber
---t, * --,r', Spread Lens !
o
iIfi [r
O 2O5 3 DowNL GHT HoustNG: THEFtviALLy pRorEcrED lllllllv o
Same aS 2052 bL-rt ,,! th non.adiLtstab e lampho d-.r 755O Prismatlc
ti
COMPLETE UNIT CONSISTS OF TWO NUMBERS: HOUS| c AND APERTURE.
-
ORDER EACH NUMBER SEPARATELY,

ACCENT LIGHT ADJUSTABLE HOUSII{G


z=
oo
Dh
Fu y adjustab e \,/hen used wth Housng 20521 lanrpholder rolates 35g" horzonla
J3-
adjusls 0' to 10" ",ertcd v Non rdlusta-be v,,hen,JSed wrth iouimq 20S:. WOe
y. | 2052 Therma ty protecled
cq)
cnoce ot a|d btrarr sprpalds lrom v..ry farrow to very vrde Seectionol o.!
o=
apertures ^aTtaqe!
back step bafle. matte back salI qod or satn cleir cone-SuiaOfe tor DOWI{LIGHT HOUSING o9
darnp ocalion. t 2O53 Therma y protected
-l .T
ro'
o.Q
APERTURE o!
ii-
2O55 t',larte Black Baff e R:s
i:-l rt" I'--iI lf i'L 2O57 vatte Black Cof e OF
JI \Lr '-
1v,
l 4'.
)
4
2O58 Anodizect Sat n co d Cone
2060
LAN4PS:
Anoo zect Sal n C ear Cone

20W.75W MB-l6. 12v.


Io
Mar cerlg tfc(.ess I ,

\OTE F.. Lo0 Votaqe it.rs ri .ss


:'anslrjrmer ....1 I laclor,r

PINHOLE ADJUSTABLE HOUSING


Srnal dpe'IJ'e accell ig'1l Fuly adiLsraore wren Jsed wrrt HoJSi..tO 2052 I 2052 Thermal y protected
a^'lprolde|Olates 358 " tO,izo'tta ly.
lv. Reco-mcloed oowllialt ,;i\r
tor nnwnti.nr
Recommenoe.J to. an;tur
rode d.le,aimilg
rnoderate aimi arqles {0'to 25.r. '). Non-adjLsrdble
Non-adiLstdble wher -seo- wilr
when _seo- wiln hous,rg
hor
2U53 Wide choce or watldges alo oea- soreaos t,om very na,.ow to ve.y DOWNLIGHT HOUSING
wroe. t^'te mdtte bacl sheld redLces ga.e. Faceplale slaos ir a1o oJl lor I 2053 Therma y Protecled
easy access to ampholder assembly. S"uitable tor bamp tocEl.on. - - -"'
APERTURE
2O6l tr,lane wn te

LAMPS: 20W.75W N/R 16. 12v


NOTE For Lo{ t,o lac. foLs.o eqs
lra.st:mer ..ns! I 1..lory

SU'T APERTURE
ADJUSTABLE HOUSIXG
S-malaperture accent lght. Fuly adjustable when used with Housng 2052;
rolales 358' horlol-laty Recommerdeo ,or 0. to 40" aimirq arg es a 2052 Thermatty protected
PI9Pq9'
ror vertrca Wde clo,ce of watrages a'to oeam sp,eaos fro.r ve,v raiow lo
ve'y w'de lrner malle blacl sh,eld reoLces gtare rdcepdle sTaps'T a-d oJl lor DOWI{LIGHT HOUSIXC
easy access lO lamorOlde'asse-bly. SLilaOe 'Or dd^]D Ocdrion 42053 Thermatty Prolected

ttt APERTURE
i l- I.'
_t ; 2062 vatte wrrite
{D iti-- 17 rL -'-i:ll_l_,=:l l LAi\,4PS: 20W-75W MR-16, i2v
l4 + 2r'"' NOTE. For Low Vollaqe Hous nq ess
lraf siormer cons!ll li.torv
Llar c! r! th ckr.ss I
t-t(tt-tT()t_t t= tr-" / 33
Series lOOO Accent Lights t MR-16 Low Voltage

5'lr# dia ceiiing openins


EASY RELAMPING
. Sa nc tensron clios on
,rmohbldei assemblv se.u'elv
:Lrpport lamP and Prolectlve q dss.
a o!4/ IaSt srap oirl Sndorn re lamp nq
-'_\ \FFr/ra,

TRANSFORMER rtn -{'


. ,ilr-
--< '.9
Suppiles proper vollage , (,LAs iAttp
to insLle raled lamo life. GLARE CONTROL
. '/ .'.- ' \'D
Regressed lanrp \11.'.i--
, .r,r ,,,,, ,
provides visual culdf to P,
MOUNTING BAR(S) lamp, prevents glare.
. For wood joist or
suspended ceilings,
e{tends up to 27" JUNCTION BOX
. N,4aximum strength . Easilv accessible
Drevents sagginO from b;th srdes J-Bor rs
'. Friction grip holds bar paral/e/ to mounting bars.
in place. . Saves tirne and
expense bullt-in cable
clamp ground wire
pry{ut knock{uts and
safetydqed covers
. U L. listed for
Through Wirjng
(2 in-2 out, 60'C oi THERMALLY
4 in-4 out 75'C). PROTECTED
. U.L. isted lor Damp . 1002P1 Frame-ln Klt
Locations. has built-in therrnal
protector to safeguard
against overheating
resultino from
impropdrly placed
insulation.

WIDE CHOICE OF FLANGELESS


BREAK-OUT SECNON/ CLEAN
APPEARANCE REFLECTOR TRIMS MOUNTING FRAME
ANCHOR CLIPS
. . BLack Step Baifle . Versatile Works for
. Works in existing L4inimum-width
(shown). both new and existing
ceilinos Permits flange for clean,
Saiin Gold Cone: ce!!!tSs.
framd 10 be put easily neat insiallation. .
thiough ceilinq opening . Extra wide flange Satln Clear Cone lrme-savrng
Push-in anchor cllPS trim ring (Accessory . Desiqn{oordinated to instaliaiion. Opening
No. 1957). match Ly4ecasler can be cut after
(supplied) secure lrame ceiling is insialled.
Downliqhts, 1000 Series.
.n '{? . Assures clean. neal
ANCHOR CLIPS FULLY ADJUSTABLE installation, acts as
. preclsion cutting
Larnpholder assemfJly
template.
on Adjuslable Accenl . No sharp edges
Liqht rotates 358'
horizontally, adjusts
vertically 0" to 35'
. For plaster ceilings,
use Plaster Ring
f,'
permittlng flxture to be (Accessory No. 1960).
NO[E: l-O\N VOLTAGE FIXTURES should be dimm
ed onlv wilh soecral oimrrets 'ntendFd lor lhal pur' used as either an accent
oose Use Liotitoler Precrsron LV Scenist, or
i,!4e.nooe, or-equ,valenr producls by olhes or
lighl or a downlight.
rifi:bre aulo.Irarslotrne.s or elealro'r. d'-nme's rr
tended for use wilh low voltage fixtures

34 /l-l(il-lT()l-ll=la'
ACCESSORIES FOR FRAME.III KIT

e 1960 c aster Rns


(r. 1956 T-ts" ;rL-o ( p.
_ l{ I .g
o d l-o mo.'r' ^g od - to _Bdr-.
FRAME.IiI KITS loo2
\^ 1964 I lvo.-r ao Bd.s se o, 2
a lOO2PI THERMALTv pRorEcrED FBAME N Klr -'\ FO e. t pme o ra.lle oo\ I O r-g ir 24
lnc udes: 13" mounting bars wh ch can be extended to 27,,: \
t
constrricl on o
rnourt ng frame, socket and socket hous ng wired to junctiof 1965 i orcea Sptire Carinq K I
o
s.- of 4. Fo .ei, "o
G
box therma protector to safeguard against overheating -q u" . -o lo 2 - !o
dbo\ o J^.reo ra i.q
resutifg from mpropery paced insulaton, No. IBSFl leads
anchoi cl ps lor ex sting ce I ngs. U L I sted for through branch
crcut wrng.
o 1oo2
offi Coor F ters and Spread Lens (see page 33)
o
'
J
NONTHERN/ALLY PROTECTED FRAIME-lN KIT for use in suspended cei ings sarne as 1002p1, but wthout
ro
thermal prolector.
REMODELER KIT E
E
a lOO3Pl FoR BREGULAR coND r oNS AND cEILtNGS up ro 2" THtcK nctudes F angetess mount ng r ng,
retainng c ps. snap-on sockel cup wred to junction box. therma protector: No IBSFj eads U.Ll sted. o o)
E
COMPLETE UillT CONSISTS OF TWO NUMBERS: FRAME.|N KtT AND REFLECTOR TRtttt OR .9
c
c)
REMODELER KIT AND REFLECTOR TRIM. ORDER EACH NUMBER SEPARATELY. o
o
E (])
o q
ADJUSTABLE ACCENT LIGHT o
o o)
Flexbi ty of applcation with lvlRl6 lamps wh ch olfer chorce ot beam soreads O
fL \ aoJstaoo IB"-ozo al / O" lo,,. v^rtLa, Bl r-,. rors-one, o
ma fta ns lu I rated ite of 20W or 5OW tvjR 16 lamps Cho ce of black step baft o cd
a
l- ad' o'le.. (Ltdoe ol oanp ord.io.]
e o
"
'l oold o 5at \(D
f FRAIIIE.IN KIT
o
o S
J
alOO2P1 Therma y prorecred
OlOO2 ttontnermattv Protect-.d
o
o lo
REIIIODELER KIT
1 alOO3P1 Therma y protecred

- "r." -.] REFLECTOR TRIM


r 5r,, +
1055 vane Btack Baff e

[4ax cer r-o l.rickness ] ," I O58 nnod zeO Sarin Go d Cone
1O6O AnoCized Satn Cear Cone

LAMPS 20W 50W N/R,16. i2v

DOWNLIGHT
Provdes precisey controled down ghlng wlth wde choice of wattages and
beam spreads Deepy regressed lamp ptevefts gare Bu lin transldrmer
ma nta ns fu I raled te of 20W or 50W tvlR 16 amps Cho ce of black step baflle,
sa1 n go d or sat n clear cones. Su tab e lor darnp ocat on

FRAME.IN KIT
alOO2Pi Therma y protected
a 1OO2 Nof-Therma ty Prorecled

REIIIODELER KIT
alOO3Pi Therma y prorected

L A''_ REFLECTOR TRIM


- 5. -l
I 065 vatte Black Baffte
[ia! ce ng lf ckness ] "'
1 066 nnoo z-^O Sat n C ear Cone
1067 Anodized Sat I cotd Cone

TAMPS 20W-50W N/R-16, 12v


'App .s lc) F,ame ln Kl ony
t- t(iFtT()t_t t= t?'/ 35
Series I|OO Accent Lights , MR.l6 Low Voltage
t%J'o,"
ti ceirins openins

HORIZONTAL VERTICAL EASY RELAMPING


ADJUSTMENT ADJUSTMENT a Spr ng lension clips on
.
. For Adjustable Pinhole
1152, horizontal adjustment
is fixed by rotating
For Adiusiable Pinhole
1152, vertical angles are
adiusted by inserting
lamorrolder assemblv securelv
supp6rt amP and Protectrve g ass,
allow fssl snap-orl, snap-rt relamprng
O1
lampholder lo desired screwdriver and slidino the
posiiion. then tightening the lampholder in the adiustment \ SPF]NG

locking screw. 10 assure slot. then tightening the >_r" //'cLtP


-.-.--'
that lamp posiiion is not locking screw. Buillin -y'- o,rr..o"o
dislurbed during relamping. delenl locks lampholders in
downlicrhl posiiion.
'<-
'/ --<.trl.,r "-
''o'o
,r,rro,*o
FING

MOUNTING BAR(S) DUAL OUTPUT BUILT.IN


a For wood joist or TRANSFOBMER SELECTOR SWITCH
suspended ceilln0si a Supplies proper a Selects 20W or JUNCTION BOX
exlends up to 27". voltaqe to insure rated 50W-75W larnp a Easily accessible
a N,4aximu m strength lamp life. operation. from both sidest J-Box
prevents sagQing. ls parallel to mounting
a Fricllon grip holds ba rs
ltar if place a Saves iime and
expense; buillin cable
clamp, ground wire. THERMALLY
pry-oul knock-outs and
PROTECTED
safety-edged covers. . 1102P1 Frarne-ln Kit
a U.L. listed for has buillin thermal
Through Wiring (2 protecior to safeguard
in-2 oui.60'C or 4 against overheating
in-4 out, 75'C). resulting from
. U.L. listed for Damp
improperly placed
Locations. insulation.

FULLY ADJUSTABLE GLARE CONTROL FLEXIBLE,


BRFAK.OUT SECTION/
ANCHOR CLIPS a Lampholder a Yoke mou nting ECONOMICAL
FLANGELESS
. Works in existinq assembly roiates 358" . moves lamp back a Reflector Trims for
1100 Series Low MOUNTING FRAME
ceilings. Permits horizontally, adjusts when tilied, allows o Versatile. Works for
vertically 0' io 45', beam to pass lhrough Voltage trxtures f ii
frame io be put easily into1101 or 1102 both new and existing
through ceiling permitting fixiure to small round pinhole ceilings.
opening. Push-in be used as either an aperture. No glare. no Frame.ln Kits in
existinq installations, a Time-saving
anchor clips (supplied) ad tustable accent disturbing Patterns on installation. Opening
liqht or a downlighl. the ceiling. for easy retrofii.
secure f rame. can be cut alter
1?,'/ {? WDE CHOICE OF ceiling is installed.
a Assures clean. neat
ANCHOR CLlPS WATTAGES AND
BEAM SPREADS
'installalion. acts as
. Up to 75W precision cutiing
ca pa b ility.
template.
a Beam spreads from a No sharp edges.
NOrL O\4 lOITAGL c {'LqFS c-roLld be d'nFo o'r'v h l'-soac:d a For plaster ceilings,
ommers -le, deo o .ralpJpo'e -"e-g''orer Peu(01lv 5ce'\l very narrow to very
.' "i"r"oe. of "qL1"1;'r' p oorcrs ov orr" ' o !a iab'rol'dgo
"rlo' wide. use Plasler Ring
l i"*ro'-ni i o' o- c orlre, ) re1o"d or LAx'lalor (Accessory No. 1961).
",",i
I
I
l 36/l-l(iF|T()l-tl=l,J
ACCESSORIES FOR FRAiIE.IN KIN

'(-' 1961 Pasrer Rins

l\ rrorrt -) (l
I _l
956 r-aar A1(.o C ,ps
fft r,*o"..,* *,r" L 6'X^' - tto2
r or anchoring -ot, t,tg ba,s Io l_Bdrs

llO2Pl THERMALLY PRoTECTED FRAME_ N Ktr L \r -1964


Lo.
:c" voJ.t,rc Bar.. ser o.2
lnc udes; 13" mounting bars which can be extended to 27,,: -
--\-\\
erl'e-e o.kefle. oosir,ol1g - 2/ {l
o
l OUnl ng 'rame: sOC{el and SOC\el rous,lg wi,eo rO jL.tclio.r Conslrllcl on (!
box, thermai protector to safeguard aoainsi overheatino
<:. Conceareo Sotire Ce ,r'rq Kil 6
'esLltng "om :rnp ooer'\, praced nsJratio.r No. tBSF_1 f' -1965
a.cho'c,ips 'or e^s 19 cel,ngs. J.L r,sleo
,eaos: Set I
o' F.o, ceilirg 'Lrrers Lo lo 2,"
above finished ceiling
'o. trroLgh o.a;c,r o
clrcuil wir ng J'
. 1102 NoN-IHERMALLY PBOTECIED FRAME- N KIT foT use
in suspended ceitings. Same as 1102p1, but without tneimai pro:tictor.
O ffi E$:15:.i"'s'read
Lens
to

tr
RE ODELER KIT E
o llO3Pl FoR TqBEGULAp coNDtT,o\s A\D cEtlNGs up Io 2" -i,cK trc rops: Fangeess .ro,nrrrg 6
retaining clips, snap{n socket cup wired to junction r,1g: E-
Ooi; lneiriai protl""L,; No. tSSF_t eads. UL tisre.l O-
JqJ
CoMPLETE uNlT Go slsTs oF
Tw..o-llu-MBERS: FRAllE.lll .." ArlD E"
REFLECTOR TRI . ORDER EACH I{UMBEi StFiiirdlV] ..- KIT REFLEGToR TRt oR REMoDELER KrT AND o9
o=
<3
DOWNLIGHT o;
OTr
Versal le. economlca provicles prec se y controled dovrnlghl
|g \,! th wrde cho ce of 5l,o
\o,'doo d.dood, o."o D6.D. .60.o. .o ,",.0." o..p. t
''d o-a ^d"d ".oo.-:..
".o.oo 0A 0Io AVtr Jo o: R,"re or
lrm fts n1o Tl0i or iT02 Frame.n Ktts n exstirq nsta utons. toi eisv,el,ot,t- FRATIIE.I KIT .9=-\-
Cho ce of btack step baff e satin c ear or satin
96 d cones S; tatttL; d;;o )11O2P1
O I l02
Therma y prorecred ,t(o
Non-thermally protected

RE ODELER KIT

-K'o
alIOOPI Thermaly protected

) REFLECTI'R TRIM
I 165 vatte Btack Baff e
I 166 enoalzeO Satin Ctear Cone
l167 enoOizeO Satn God Cone

LAMPS: 20W-75W MRt6, 12v.

NOIE For Lo Volage Fetector Tnm ess


rranslo.mer consu I taclory

(.

ADJUSTABLE PINHOLE
Maximum iex bility wth 35Bo horizo|ta rotaton and O. to 45. verlica adiustment
Yoke aiming system ensures cons sien|y accurate beam orientailot io ;i;rnum
'p nhole ' aperture which conceals larnp assemb y Faceplate FRAME.III KIT
sna;s in unC ort on
'etdriag_so ngs -o' edsy e alor.ro DLd, oL'p .. trd-<rol^ p. *"
r-li,-, i ,i .aleo ,i.e a I I O2Pl Therma ty prorected
O t I 02 tlon-thermally Protecred
oI zUW,50W or 75W MF 16 arnps Releator trirn fts nto ITOT or l1O2 Frame,ln
Kti n e. strg i_Sta'd-On . 'o' ed.\ 'et o.l SL,tdorp ror daTno ocalon
RE ODELER KIT
al lOSPl Therrnally protected

REFLECTOR TRI

)
I152 vatte wnire

LAMPS. 20W-75W N,4R-16, 12v.

NOTE: For Lor Voltage Rellector T.tm ess


lransiormer consull lactory
For Gulde 10 Lighting data, see page 63. 'Apples 1o F am. I I rofy t- t (i FtT() t- | t= t?. / 37
Series ilOO Accent Lights , PAR-36 Low Voltage
t%J'o,"
ti ceilins openins
JUNCTION BOX SNAP.IN SOCKET'
. Easily accessible a Assures new ease ir,
from both sides: J-Box lamping by eliminating the need
is parcllel to mounting to attach leads to lamp terminals.
bars. o No screwdriver required to lelamp.
a Saves time and The detachable !ampholder is removed
DUAL OUTPUT expense; built-in cable tron relain;ng ri.q: PAR36 ramp'err\ar'ls
TRANSFORMER clamp, ground wire. intact with snap-in socket-'
BUILT,IN a Provides versatility pry-oui knock-outs and
SELECTOR SWITCH for usinq 12v. or 5.5v. safety-edged covers. SOCKEf
a Selects l2v. or 5.5v. lamps, with choice of . U.L. listed for
operation. bearn spreads ranging Through Wiring
a Mounted flush to from very narrow to (2 in*2 out. 60"C or
prevent accidental wide {12v.) to 4 in-4 out, 75"C). DEfACHABLE
switching 1(] undesired extremely narrow . U.L. listed for Damp
voltaqe. ''pin spot" (5.5v.). Locations. \

MO-UNTING BAR(SJ /;
a For wood joisl or
suspended ceilings: extends
up la 27".
a Maximum strength prevents
saggrng.
a Friclion qrip holds bar
place. t
in fl
J}

BREAK.OUT SECTIONI
ANCHOS CLIPS
a Works in existing
ceilinqs. Permits
frame io be put easily

FLANGELESS
MOUNTING FRAME
a Versatile. Works f or
both new and existing
ceilings.
a Assures clean, neat
installation. acts as

(Accessary No. 1961)


FULLY.ADJUSTABLE
. Lampholder WDE CHOICF OF
assembly rotales 358" WATTAGES AND
horizontally. adjusts BEAM SPREADS
lr.oTL LOW VOTTACL I IXTURLS sloJld be oi-med olry sil'r spec;a'
otec sior lV Sce llsl
vertically 0' to 35', . Up to 50W
dimmers intenOeo lor lhd' pLrpose tJse I 'ghlo e' permitting fixiure to capabilily.
-"*."0e or eou:valerl p'odLcls by orers or var'able aLIo- be Used as either an a Beam spreads from
"i
ir.{rni."i. oielecrronic dimne's inlerdeo lo rse ?vrl'l low vohage
lixtures. adjustable accent extremely narrow to
liqht or a down liq ht. very wide.
38/l-t('HT()r-ll=ltJ
;l,dp
AGCESSORIES FOR FRANE-II{ KIT

e tgol eraster Rins

FRIUE.ll{ t(TS
tlotPt a 1956 r-gar Anchor Ctips
Fo' a1cl"o'19 moJnt,nq bdrs to T-Bars
l/
0llO2Pl THERT\IALLY pRorEcrED FRAME-|N Ktr 1964 zo' MoLnring Ba's. Sel oi 2 o
lncludes: 13" mounting bars which can be extended 10 27,,: 'Y+- Ior extreme olf{e'ttet postltonino in 2r'"
(!
mounting frame; socket and sockel housing wlred to lunction construction.
box; thermal protector to safeguard againsi overheati;g
1965 =o
resulting lrom improperty placed insulation, No. jBSF_1 leads: \.\ Conceateo Sp, rc Ceitrno Kil
ancho'c ios ro'exisri']g cel,ngc UL lsreo .or l.roug- brarc^
I Sel ol 4. For cei, rc rJn.lers uo r:o
above linrshed ceiling
2," I
o
clrcutl wrflng. J
a 1102 NoN-THERMALLY pRorEcrED FRAME-IN Ktr for use
o
('
in suspended ceilings. Same as j1O2p1, but without thermal protector. tr
REMODELER KIT o.
I ll03Pl FOR IRREGULAB CONDlrloNs AND cEtLtNGS Up rO 2'TH CK. tnc udes: Ftange
ess mounting ring, o
retainlng clipsi snap{n socket cup wired to lunction box, therma protector; -
No. 18SF_t leads. U.i lsied .c
J
u) -
CO PLETE UTIT COTSISTS OF TW..O-IIU B,EXA: FRAiIE.IN KIT
--.. AIID REFLEcItoR TRI oR RE oDELEn KIT AIID c
o_
O
REFLECTOR TRI . ORDER EACH NU BER SEPARAi-'Y.--- q| o
o
o =
a)
ADJUSTABLE ACCENT LIGHT
o (n
o
\(0-
Fleribilily of application. Dual output transforrner altows use ol i2v. or S.sv pAR-36
larrps ava,lable in a cl^oice of beam sp.eaos. irc,ud ng 5.5v. ext.emelv rarow .pir
spgr l4Tq is- re_g.essed ro p'eve1l glare. Lampho oe; rotares 358 " honzonta ty.
adjusts 0" 10 35' verl,carly. Srali'l socket assLres fasl, easv la^.to nq. qet.oiits ,n FRA E.III KIT .9
exis.ring nslal,atio'ts wlh 110^ or 1102 Frame-lr Vatc"es apoearince ot Srep alI O2Pl Therma y protected {,
Barlle and Cone lpage 18) SLilabre {o. da-p localor. ^its O I lO2 Non-Therma y protected o
F
RE ODELER KIT
al I 03Pl Thermaliy protecred
REFLECIIOR TRI
I 155 vatte Btack Baffte
I158 enoOizeO Satin cotd Cone
ll6O nnoOizeO Satin Cear Cane

LAN.IPS: 25W PAR-36, 5.5v


M: .e n! h.rr.5 r . 25W-50W PAR-36 12v.

NOTE For Liw Voltaqe Bereclor Trm ess


lranslormer consLrl f:.1.tu

ADJUSTABLE EYEBALL
Accer-rt ightlng on horizontal and vertica surfaces or do!,,,nightng n sloped ce ngs
Sturdy one-piece housing rotates 35B..hb zonjaly adlu.t: d" to 35" veirt iatfy D-ua
oulput,lranslormer provdes !Frsd1 lty lor usng i2v oi SSv pen:Olamps.with FRA E.III KIT
d6 /'.O'.a o'bed^ o -dd 11 o Q . .,.or 6, rd,.o^ Dr. _oor [/"le a l I O2Pl Therma y prorecred
^
bd..eood._ao ,"i" t,' d-oooa. .do.. ;o.o .;ro. O I I 02 Non-therma y protected
lasl re ar.tp |g Retrofits n exisl ng |sta al ons w tlt 1l0l or 1102 Frame ln Krls -
Suitab e for damp ocal on
RE ODELER KIT
()llO3Pl Therma y proteded

REFLECIOR TRI
I
ll62 va e White wirh
Mafte Black Balfle

LAI/PS: 25W PAR-36. s.sv


25W-50W PAR-36, 12v.
Mai ce l.O rh ck.ess l , ' NOIE For Lo, Volage Fetector Trim ess
rransrorrner consLrll factory

For Gulde to Lighting data, see page 63. 'App es lo Frame | {t of y


t- t(it-tT(>t_t t= tr-'/ 39
Series llOO Accent Lights , R and PAR Line Voltage
t%u'0,"
6 cei ins openins

CO PLETE Ul{lT cO Slsni OF TWO llUtlBERS! FRA E.IN KIT


REFLECTOR TRIT'. ORDER EACH IIUMBER SEPARATELY.
A D REFLECTOR TRllt OR REMoDELER KIT AllD o
ORDERIIiG

ADJUSTABLE ACCENT LIGHT


(R & PAR lamps)
Fuly adjustable-3s8" horizonta ly, 0'to 30'verticaly. Face
of lamp is regressed and shie ded for viewing comlort by
prec sionj lted baffle. Matches appearance of Step Baff e
downlights (page 18) and Low Vo lage Accenl (page 39). FRAI EJI{ KIT
Su table for damp location.
ll lO2Pl Thermally Protecled
i I l02 Non-Thermally Protected

L
O

REMODELER KIT
tl I O3Pl Thermaity Protected

REFLECTOR TRI
I127 vatte Btack BaJJ e

- 6. LAMPS: 75W R-30 / PAR-38


100w R-30
[1a! .. rq rr.k.ess 1 ' ' 150W R40 / PAR-38

ADJUSTABLE ACCEI{T LIGHT


(R & PAR Lamps)
Fu ly adlustable-3s8' horizonta ly, 0' to 30' vertically. Face
of lamp is regressed and shie ded lor viewing comfort by
precisionJitted cone. Matches appearance of Cone downllghts fi$
(page 18) and Low Vo tage Accent (page 39). Suitable for damp FRA] E-II{ KIT
ocation. allO2Pl Therma y protecred
Ol 1 02 tion-thermatty Protected
RE]SODELER KIT
t)llOOPi Therma y protected

REFLECT1OR TRI
I137 enoOizeO Satin cold C,one

LAN.4PS: 75W R-30 / PAR-38


100w R-30
150W R40 / PAR-38

ADJUSTABLE ACCENT LIGHT


(R & PAR Lampsl
Fully adjustable 358' hor zonlal y, 0 " to 30'vertcaly. Face
of amp s regressed and sh elded for viewing cornfort by
precls onjllled cone. Nlatches appearance of Cone downlights
(page 18) and Low Voltage Accenl (page 39). Suitable for damp FRAME.III KIT
locat on.
tl lO2Pt Thermally Protected
O l102 Non-fhermally Protected

REiIODELER KIT
alIOgPl Therma y Protected

REFLECTOR TRI
1147 l\nodized Satln Clear Cone
O.
LAI\,4PS: 75W R-30 / PAR-38
100w R-30
l/.r ce n! 1!.kre:s l ' 150W R40 / PAR-38

40 / t-r(t Frr() r-r r= l? 'APP es lo Frame- n K I on Y


Eyeball Accent Lights / R and pAR Line Voltage

5'1,; 1 6"1'{ / 9uld' ""ins


open ng

)' ,. sslrrrrrE u*tr


' nEFLEcroR
-rc corastsrs oF Two
TRIM. oRDER elcx
uMBERs: ,rnaME.rN
xu eii sEpln^liiiv.
Krr al{D REFLE.ToR TRr oR RE .DELER Krr a*D q)
o
G
o
ORDERII{G
o
ADJUSTABLE EYEBALL J
Accent ightng on horzontal and vertca suTfaces oT downlghtng E
n soped ngs Rotates 358. horzontaly adjusls O. to 4d. -
o, d ?eiD rdo6 1q r ld te odL^ c
..o ,oo..o !
bdt.6 Ihr od,e <.r"o.^ o od- lt o d,o E
G
t-5 .,- FRA E.IN KIT E
allO2Pl Therma y prorecred
o
O I I O2 Uon-tnerma y protected
gl
).' RE ODELEB KIT
tl I O3Pl Therma ly prorected
o
o

t REFLEGTOR TRI
I O22 vatte whire wirh
Matte Black Baffte
o
o
!(!
LAMPS: 50W R-20 v,
Max ce fg th ck.ess 2!', ' 75W H-20 i--

ADJUSTABLE EYEBALL
Accent lig-t ng 01 'to'izo']la and ve.tical sJ..dces or oownl,ohlino
n Sropeo cerlilqs Rolates J58" t'orzorraly aousls 0. to"+o."
verlically. Duraote. one rousrng wil^ nialle oacl step
| ,(fu - oiece
l,f'le whic' reouces glare. [,4alcres appea.d-ce o'_ow
Voltage Eyeba I (page 39). Sultable for damp localion.
FRA E.III KIT
allO2Pl Thermaty prorecred
OI l02 lon-tnerma y protected
RE ODELER KIT
allOgPl Therma y prorected

REFLECI1OR TRIII
I 122 vatte white with
Matte Black Baffi-.

LAN,4PS; 75W R-30


Max ce ng lh.kness 1',, 100w R-30

ADJUSTABLE EYEBALL
Accent lghl ng on horizofla and verl cal sLlfaces or down ohl nq
n soped ceilings. Rotales 358'ho|zonta y acllLtsls 0. 10 4d. -
.-', " L DL "o. o't-.o. a ho r ic .
^' ,o. odo bd
6p odti,6
l eo , o g,d.a 'dop ro oj np
^
FRAME-II{ KIT
) 1202P'l Thermaty Prorecled
a 12O2 Non-Therrnatty Prolected

REFLECTOR TRIM
1222 r,tatte wh te w rh
Matte B ack Baff e

TAMPS: I sow R 40 i pAR 3B


25OW PAR 38
6r:"
300w R 40
9-
io. ,l
Mar ceitifg thck.ess t,
For Guide to Lighting data, see page 63. rApp es to Frame ln Kir ony
r-r(tFrT()t-il=t?'/ 41
WALL WASHING
As a medium for expanding or defining-.**--.
space, enhancing a qroup of pictures or CF),
one large picl.ure on a warl. or revealing the
torm of sculpture, wall washi'']g has no
equaL
Recessed wall washets are designed
specilically to wash verlical surlaces wilh
eve.r spreads of illumination from ceiling to
floor and are intended to be used in
multioles to achieve the desired eIfect. The
inten!ity and unilormity of the riqht can be
aonlrglled by varying the distance ot the
fixtures from the wall and their center'to'
center spac ing. ..J
Embossed "scoop" ref lectors redirect
lioht to the upper part of the wall, to fill in
shadows and eliminate scallops. lnternal
anodized aluminum rellectors, iogether with
faceplates that conceal the light source.
assure maximum light output and minimum
brightness.

Wall Washers
t%u'o,"
6COI'PLETE UrllT.eCOllSlSllS
ins opening
OF TwO NU BERS! FnA EJN KIT Al{D REFLECI1OF TRl l OB
iiiiboElEC kir aio nerlecron rRlM. oRDER EAcH TUMBER SEPARATELY'

SMALL APERTURE
WALL WASHER
Gives even $rash ol lght w lhout
scallops or shadows at ce ling
i rne StT]a aperture conceals
amp Doub e Anobrite' reilector
I
systean and econom ca A" larnP {, @-"
Orovide hiqh eif c ency. Fast
relamprng wrih snaP I snapoul
aoerlLrr-o sh e d SLr lable lor damP
ocation.

i Max ce rng thcknss: 1"'

I
i STEP BAFFLE
WALL WASHER
Grves hjgh- ntensity, smoolh wash
ol lioht w thout scallogs or
shadows at ceilrng line. Anobrlt@
reflector svstem and optical black
step baffle assure maximum light
output and minimum aperture
br ohtness wilh 'A or "R" lamps.
I N,la"tchesappearance of SteP
N
Baltle (page 1B). Su table for
damp location.

i Max ceiring lhickress 1 " '


I 'App es lo Frame.n Kir ony
42lr-r('l-lr()l-ll=l?
-*

.{e} '{ &., ,;

, .\

;* (_.J

il3
fls
l|sG o
'' 'i t O)
:
c)

{,
I \! .q
o
(! \(o
3 N
!o

ORDERING

FRAIf,FII{ KIT Footcandlss on wall toow a.t 9


{)l lO2P'l Thermally Protected lrom multlple unit6 1%'
UNITS UNTTS 3'
FBO]\,1 WALL
Oll02 FROI\I'WALL

l-t . rr r- "
NorrThermally Protected . l--,r '-,
tt4/ 4u 4/ rh
RE ODELER KIT lt t 13 .5 14
t)l IOOPI Thermally protected -2138 38 38 _21.c 16
=Jl22 13 22 ;311. r t5
REFLEGTOR TRI :4'l13 13 1J -atrl-4 lJ
r'5'I B 9 I icl t r- '
ll25 l,tatte wnite ?61/6 67 b7 !6ls lo
:/'f :,1 / I /
LAMPS: 100W Atg 'B'l 5 5 s "B'l 6 6 6
g',I 5 5 5 9'I 6 6 6
r.o d5
d' ot"-dt ,F o.d?0do .
ro r' Lre 0 qJ rd .tar, " ofp tio. t1o\d.ro^f L dTd{furmo I ro I \0i. nd
10,('01 cDetrder ,Ld5 ord,elowo ro.De(re,s

FRA E-III KIT Foolcandlos on wall r 50w A.2t l50w R.40 FL


l{lO2Pl Therma y protecred
OilO2 Norrlherma y protected
ftom mulliple unlts
lrh
k--.-.
' riiri rh
UNITS 3' FROI,I WALL
? ---'l t-/' t
UNITS 3' FROI,4 WALL

1t13 12 13t11 t0 ti 14
NE ODEIER KIT 2'121 2a 21 17 14 1.
17 2' 17 '16 17 13 10 13
t)l lOgPi Therma y protected E3'126 24 26 120 $ 2a 9s' 16 14 16 14 1A 14
34't24 24 24 l2a $ 20 34' 16 't4 16 14 10 14
REFLECIOR TRI Fs'i21 22 21 lts t6 t9 Es' 16 14 '16 12 10 12
;6'i17 18 17r15 t4
ll35 laane While wirh ; li3
38;1i t2 | ltl B
i; i|l; l; l; !6'
15

t1 36,
14
11
14
12
14
11
10 10 10
9 10 I
787
l/atte Black Baifte g',i 9 10 9
9 10 919 6 I 9', I 10 I 767
For r9 mulprytookandesbyo6.
I00w A
LAMPS: 100W Atg -oo o1ol" !"La oF d rooeo
d oT,1 ,rno td,n,ts
150W A-21 / R40 4 h,Let0{d dis01 a o\e rFdl to.p.-oa. ,,e-arrLFo.rto l oi no
. tr.es di r. e to ao

For Guide 10 Lighting data, see page 63


l-r(tFtT()t_t t= t?'/ 43
7o 11 DOWNLIGHTS
The 7.11 group of downlights
provides h igh quality general Quality , Budget Downlighting
iiqhtinq, accent lighting and wall WHITE
washine for lower budget iobs. REFLECTOR
Non-yellowinq, scuf t-resistant
Perma-White ref lectors assure
efficiencv with economical "A"
lamps. Ail 7.11 downlights can be FAB M()BE LIGHT THAN
installed quickly and easily in new DOWNLIGHT WITH()UT REFLECT()R
or existing ceilings.
GOOD LIGHT OUTPUT
Refleclor, linished ln Perma Whiie enamel to
provide high reilectance, will not yellow. Lighl ls
nol trapped and wasted.
fl
SHIELDED
MNE
f\
fvr)
STRAY t_:
EEIGHTNESS
r/
GOOD GLANE CONTROL
-a-p S eg o55eo above lae.ell g Ine 10 ctll
o'f oislrdcl,aq b tqhrn..,., 'or .ros lo, olionc d"
people rnove wrthin a roorn.

7o 1l Downlights

5 %;;," ceiing openins

COtspLETE Ul{tT COI{SISTS oF Two NU BERS: FRA E.IN KIT AND REFLECTOR TRII OR REMODELER KIT A D
REFLECTOR TRIT . ORDER EACH U BER SEPARATELY.

OPEN REFLECTOR
Low-brightness sp ay provides
v sua comfort. Perma-While
linish assures efficiency wlth
economical 75W Al9 lamp.
Suitable for damp locatlon.

Max ce ng lhckfess 1"

STEP BAFFLE
Prec sionJitted step baffle
reduces glare. Perma-White f in sh
assures efflciency with
economical 60W Al9 lamp.
Suitable for damp location

S{
Max ce l.g thrckness l"'

'Applres ro Frame ln K I on y
44 / r-t(tt-tT()l-l l= l?
AGCESSORIES FOR FRA EJ KIN
f.. - J I 96O P aster Ring 0
to02Pl
-
1002 1. 1 956 r-aar Arc or C p: o
,Y For a-cho.i.g mo_ltirg oa \ to t-Bars o
FRAME.II{ KITS
a lOO2pl THERN,IALLv pRorEcrED FRAME-IN K r tl 1964 2j" Vour-ing Bars. Set o'^
nc udes: 13" mount ng bars which can be extended to 27,,. ' Fo e)l.e-re offfenlet oosrollg ^ 24,,
a)

mounting frame, socket and socket housing w red to junction


>--<.. constructron i
box: therrnal protector to saleguard aga nst overheat ng - 1965 Cnrced ed Sotire Ceitirg t o !
resulllng from improperly paced insuation; No. 18SFJ leads,
- Set of _4. For ceiti^g 'L^-e's -p -; ^2,
6'
\:t
anchor clips for existing ce lings. U.L. listed for through branch
circuit wiring.
o loo2 NON"THERMALLY PROTECTED FRAME-lN K T lor use ln suspended cei ings. same as 10o2p] but wtthout
aDove ltntsneal ce lrno
1.. o
thermai protector.
RETIIODELER KIT
I lOO3Pl FoR IRREGULAR coNDtIoNS AND cE L NGS up ro 2,,rHtcK. nciudes: Flangeless mounting rlng,
retaning clips, snap-on socket cup wired to junction box, thermal protector; No. igsF-j eads U.L. lsted

ORDERING

FRA E.Il{ KIT 75W A.19 oow R.30


r
ulri- - uiii-
t lOO2Pi Thermatty Protected -3xcr-e
Eixor-:
fr b I .a l.m0E
a lOO2 Non-lhermally Protected
I B'
RE ODELER KIT r0' 10
OIOOOP1 Thermaty Protected
t LT|PLE iltrlTs ntuLTrPLE uliris
NEFIECION TRI
lOTl turma-wnite
4',
LA|.4PS: 75W A-19
100w R-30 6' 2\)
tl

FRANE.III KIT 60w A.19 75W R.3() FL


uNtr-
tlOO2Pi Thermally Protected H , L F. lBe;r nh
--stNo!E
OIOO2 ttorrrnermally Protecled
8' 3 [14 14
BE ODLER KIT ]0,22U
alOO3Pl Thermatty Protected 12 1 25
MULTIPLE UNITS mulrl*e ultts
REFLECTOR TRI
lO76 etack eatfte ct
4', 18 14 2A
LAMPS: 60W Al9 6' 6- l6 t:
75W R-30
I' 8 7

For Gu de to L ghting data, see page 63


t-t(tt-tT()t_t t= t? / 45
7. 11 Downlights

6"lr'ri 0," cp ins openrns


I

CO PLETE UxtT CO SISTS OF TWO I{UMBERST FRAME.I KIT Al{D REFLECTOR TRtIf, OR RETTODELER KIT
AND REFLECTOR TRI . ORDER EACH IIUI'BER SEPARATELY.

OPEN REFLECTOR
Low-brightness splaY Provides
vsual comfort. MaY be used
with'A', "R" or "EF" lamps.
Perma-White linlsh Suitable for 6
damp location. d
g

Max. colllng lhlcknss: i ".'

OPEN REFLECTOR
Low-lcrightness sp ay provides
visua comfort. May be used
with 'Al "R" or "PAR" lamps
and with 250W infrared amp to
provide localized heat for bath
areas, food counters. Perma-
White f nish Suitable for damp
ocatlon.

6't', -

Max ceihfg thickness li"'

STEP BAFFLE
Precisionjitted step balf e
reduces glare. Choce of 'Al "R"
or "PAR" lamps. Perma-Wh te I
flnish. Su table lor damp
l
location.

Mat ce ling th'cknessr r " '


"App es lo Framern Kl ofv
46 / r-r(tr-tr()r-r l=l?'
ACCESSORIES FOR FRAME.I}I KI}

e 196l easter Rns

tO 1956 --bo
-r cao Ctip.
I Io d'tcuo .lg ^toJr l-q o".s lo TBa .
a llO2Pt THERMALLy pRorEcrED FRAME tN K T ro a t'e^ . o -c e .
fcludes. 13" mountng bars which can be extended to 27,, \_^.- oosi o.l'to 'l I
mountrnq frame: sockel and socket housing wlred to junction
\\ CONSITUCI ON

box: thermal protector to safeglard aga nst overheating <-:\ 1965 Con, e, eo iol,ra Ca rir g ( r

resutng from impropery placed nsulaton No. lBSF-i eads. )- Spl o' .4 ror rpih-q L.^d S -D lo 2--
anchor clips for exist ng ce lngs U.L. lsted for throuah branch above finished ce ng
c rc! t wiring
a 1l02 uor.r:THTRMALLY pRorEcrED FRAME-tN KT lor use in suspended cei ngs Same as 1jo2pl, but without
thermal prolector
REMODELER KIT
a llO3Pl FoR RREGULAR coNDToNs AND cEt!NGS up To 2" rHlcK nctudes: Ftangetess mounlng rng
retaining cips, snapon soaket cup wired to lunction box: thermal protector No iBSFI leads u.a lsted o)

o
OJ

o
ORDERI G PAR Lamp ER Lamp
. o
:c)
FFA EJI{ KIT 75W A.re loow R.30 o
al I O2Pl Thermaly protected c ci
Ol l02 ttonfnermaily prolected
o :;
o' N
o
RE]SODEIEF KIT
r)llO3Pl Thermalty Protecred
F
REFLECTOR TRITS
tutYtPt! ullt! xutnFi-! utn! xutrrPtt urm
sR = i0
I I 7O Perma-White

LAMPS: 75W Al9/R-30


m 100w R-30

FRATIE.II{ KIT 100w A.19 1sOW PAR.3A FL


'
0ll02Pl Thermatty Protected uNri

O I lO2 Non-Thermally Protected i.l' ll


sTNGLE

rDrolr
r.r
|
btrct-e uxri
Tu,;n"
;..,
"lrllI ]r'-
e
RE ODELER KIT
I I I OgPt Thermaily Prolecred .l.l-
lL 16
10'l
12'l a,l
l1 c

MULTIPLE UNITS MULTIPLE UNIfS


REFLEC'{'R TRI
I l7l Perma-White

LANIPS: 100W Al9


o I or A'
'lt )
15OW R.4O / PAR-38
250W F40 lnfrared Heat e I rs

FRA E-III KIT l50w R-40 FL 1 sOW PAR.3A FL


0l lO2Pl Thermatty proteoed sttcie unrr SINGLE UNIT
lO2 "l , lF,, r.
O I NonThermally Protected tf'

NE ODELEB KIT s'Ju,ir


10 l7. l4'
f llO3Pl Thermatty Protected
124n5
REFLECK)R TRI
I176 gtack Battte
lr
LAL4PS: 100W A-19 4-
15OW R4O / PAR.3B ;

For Gu de to Lighting data, see page 63


f- f (i f-tT()t_t t=tt_' I 47
7. 11 Downlights

6"/,ui o^ceir ns open ng

co PLETE UN|T CONStSni OF TWO U BERST FRA EJ KIT AND REFLEGTOR TRll{ OR REI ODELEn KIT Al{D
REFLECTOR TRII . ORDER EACH XU BER SEPARATELY.

STEP BAFFLE
Precislon fitted step baflle
reduces glare Cholce of 'Al "R"
or "ER" lamps Perma-White
fin sh. Suitable for damp ocation.

Max ceiiing lhickness: 1i'

VERTI.GROOVE
Excellent br ghtness control with
balf e of vertically grooved high-
lemperature phenolic. Cholce of
'Al "R" or "PAR" amps. Perma-
White finish. Su lable lor darnp
ocatlon. s
I

Max. ceiling ihickness 1"

FU'SH OPALEX
N,4ax mum lght output with
diffuser of v rtually unbreakab e
Lexant (polycarbonate). Easy
tw st-lock relamping. Perma-
Wh te f in sh. Suitable for damp
location

Max ceihng Ihlckness: 1i'

"Appres 1o Frame.n (ir .i y


48/r-r('FtT()r-ll=ltj
c)
o
o
PAR Lamp o
o
FRANE.III KIT 6('w a-ie gl
!
?5W ER.30
-- !Dorr-i-
f llO2Pl Therma y prorected lltorr u{ll
I Ec TB-' o"
l"
c a
a I I O2 Non-Tnermatly Protected
r.i
Fb !r ;o alr.- not ]o \o
3 14'. o
RE ODELEN KII
I llO3Pl
BEFLECTOR TRI
Thermatty Protected
f,urrlPt.E
2 2A'

uii.r! MULttPtl uxns xutttPrr urn!


sF = 10
t- o
1179 ttlatte Btack Baffle

LAMPS: 6OW A.19


75W ER-30
100w R-30
Ejz
=+l=F

FRAT{E.III KIT I OOW 4.19 t50w R.40 FL


f tlO2Pl Thermally Protected nl
SIIIIGLE UNIT
L rr Ii,* ii;
srxcLE uili
a l lO2 Non-Thermally Protected F t , . f,.
s l .r I s B'
REIODELEF KIT l0 6 I rl 10'
f I IOOPI Thermalty Protected ,r' I , I r+ 12

REFLEE I'B TRI


1175 glact aatfte Urr

21 ,ro 1 to
LAi4PS: 100W Al9 I
'150W R40 / PAF-38 u' 1) 4tl I t,
I I l 4l,'
FFAINE.II{ KIT 75W A-t9
f 'l lO2Pl Thermally Prorected SING!E UNIT
, I r;,
rI lO2 Non-fnermally Protected
lBFn

8' I tE
RE ODEIER KIT t0' ' tl
f llOOPi Thermatly prorected 12' 1121',
BEFLES'OR TRI
rc ll77 Opat t-exan
,,,i t,,,,,
r , r l.
+I :
LAMPS: 75W A-19
-,1.l
r,

For Guide to Lighting data. see paae 63. (i


t- | t-t T(> t- ! t= tr-' /49
7. 11 Downlights
t%r'0.,
6 cei ins openins

COMpLETE UNIT COI{SISTS OF TWO NUMBERST FRAME-|I{ KIT AND REFLECTOR TRllll OR REIIIODELER
KIT Allo
REFLECTOR TRIM. ORDER EACH NUMBER SEPARATELY.

DROPPED OPALEX
(Shower Lightl
Max mum ight output with
gasketed d ffuser of vlrtua y
unbreakable Lexant
(polycarbonate) Easy twist- ock
re amping. Perma White lin sh
Sultable for damp ocatlon.

L-71,, !
-----
Max ceilino thickness l"'

ADJUSTABLE EYEBALL
Fu ly adiustable accenl lght for
loca liqhirnq on horlzonta and
vert ca surlaces or downightnq
in sloped cellngs Rotates 358'
hoflzonlalv. adiusls 0" to 40"
ca tv Fernia White f nrsh
"-.rt
Suitabl; for damp location

WALL WASHER
Liohls a vertical surlace
srioothly and ellicient Y Permits
re amplnq without removing
facep ate Perma-White flnish
Suitab e for damp locat on.

r
TTrademarri Ge.era E eclr c Compafy Mat. ceiling ihickness: t"
'App es lo Frame n Kl only
50 / t-t(il-lT()l-l I= lt-'
ca
o
o
FRATIIE.I I(IT 75W A.l9 a
attO2Pl Therma|y protecred SINGLE UI{IT
r l!r,
!o !
O 1l02 Non:rhermally Protected
r.,
o
t tr'
RE]IIODELER KIT
tl lOSPI Thermally protected
ll
12
26
ii3
F (o
REFLECIOR TRIIII
I178 opat Lexan

LA[,4PS: 75W Al9


; -
hF
1,,
i-
FRAIIE.III KIT
ll t02Pl Thermatiy prolected
O l102 Non-fhermatty Protected

REMODELER KI?
ItlO3Pl Thermally Protecled AIMI}TG AIGLE ' FROM VEFTICAL
Dstanc (0) 3', 4',
REFLECTOR TRIIII
1182 Perma-White

LA[.4PSi 100W R-30


75W R 30 FL
75\iJ R-30 SP
50
r53 22',
t 3.4
0.9'
13
48
1 68
Iu
6
21
t
66
102
2.8
3
12
I 13.7',
37
100w R.30 F B5 t 21 t I t 6.9 5 I 92',
FC rs nla lool..tu es ar .enler ol b-A!m
B..nr l]e qhl iH) ana B-eam W.rlh inr'lare io rrie por l lrrai lhe.and cpower.iroD! t! 5Ir!! or na:imrn
TF!.aFnr L,ra.brc tr!r1

FRAISE-III KIT
.t
oow a.t9
Footcandles on ryall UNIIS 2' FROiI WALL
tllO2Pl Therma|y prorecred lrom multiple units UNITS 3' FRON1 WALL

Ol I 02 ruon-thermally Protected

REi,IODELER KIT 1',39 36 39 29 19 29 1', 14


ll I OSPi Thermaly protecred 2 49 47 43 33 30 33 22 2A 22 116 14 16
35 35 35 23 25 23 23 23 23;18 16 18
E4' 29 26 29 19 rB 19 7q' t9 19 19 116 t4
/,L REFLECTOR TRI 16 1B 16 13 12 13 ;5' 16 15 16 l13 12
16

tl ltes
13
\ Perma-white :o' 11 12 11 989 96'. 12 11 12tlA 8 t0
BB8 666 Et'
.B' I 10 918 6 B
LAI'IPS. 100W A-r9 Ee' 888 666 B B alo 6 6
9', 187 666 9', B B Bl5 6 5
Lo,i,o [. .. r o.,ooq d,.....o.oorto-o
0,o,1d.."o" o,o,.l-,. r"^_. i.L;.
d6ia ce 1o wa I ior hesr .a\,[(
For GJ,oe lo .ig^l rq data. see pagp 63
t-t(it-tT()t_t t=t? / 51
COMPLETE UNIT CONSISTS OF TWO NUMBEnS: FRAME-lN KIT Al{D THERMALLY-PROTECTED REFLECTOR TRtM.
ORDER EACH NUMBER SEPARATELY.

LIGHTII{G DATA

ALZAK CONE DC.IC FRA IENI{ KIT toow A.tg


lA Lampl a llO2.lG --'aiiblE uirr
Compact down rght assures effic ency w th spec! ar Nl ro I Ft TbsrnD
go d or specu ar c ear A zak"r rei ector !a/h ch .ataxim zes n'' l,.o t.-
gh1 output frorn economical 100W A 19 amp. SLtilab e REFLECTOR TAl I l2B e
tt43. tc !
f:
for damo local on
o
Specular Goid Alzak
ll44.lC r: lr" o
o
Specular Clear Alzak MUIIIPLE UIIITS
o
A
LAN.4PS: 100W A 19 ilr nrie ntr lsmi Fr
t
!t.
:o I rz
(!
E

E=
Fbl
*q
o
EE
O=
!p
t.3
ON
CONE
PrecisionJitted aiurninum cone in anodized satin
oold or anodized satin clear linshes
Anobr le@ reflector. Suilable for damp ocaton.
trc. rc FRAtrE.t KtT
a tlo2. lC
' toow
'' glcreR.40 FL
uxrr '
t c l+am c;u.
'''' 60w a-t9
aiNGLE uNi-
.I
JP.i,i "i
ro
REFLECTOR TRIU t0t6' 6 t0
ll08r lG nnooizea l6 I
c Satin Gold Cone
lllO r lG enooized
Salin Clear Cone
Itl Ill

LAMPS:60W A-19 il Lr
90w PAR.3B (t-H) .r !l t

100w R.40 6' 2,1 19 r.j


l

.15
For SOW PAR38 FL (FH), se 1175.1C ard 1176.1C pSe 54

i,4ax. ceiiinq ihickress: 1,.

OPEII REFLECTOR DC.IC FRAME.II{ KI? 90lrv PAn.3a


Low-brightness splay provides visual comfort. a llO2.lC 100w R.40 FL
Perma-Wh te fin sh. Suitable for damp location srHcLE uirr -_-
Hr r. I . lBPn nd
REFLECTOR TRI F, jx, ;.r-
tlTl .lC
Perma-White

LAMPSj 90W PAR'38 (T.H)


100w R-40

[,4ax. cerling lhickness: %".

For Guide to L ghting data, see page 63 l- l(i t-tT()t_t t= t? / 53


DC.IG Downlights , Thermally Protected
t%u
6 0," cei ins openrns

STEP BAFFLE DC.IC FNAE.I KIT 100w R.40 FL . 60w A-19 ...
Oot car Dracl. I nisl' on p ecis orj lleo al,lmilL- a {1O2.lC s|lcLE Utlll SINGLE UNIT
step ba"le reouces glale A'looriteo 'e'lector Hr bIFr
oo. | ,n i.
l ;;D; rr trc l&^ D"
Fm, ;l J0 .,rr)!- ,,or
Suilable lor damP ocat on REFLECTOF TRIIII F

ll05. lG -it' | :a Id s'lo jro'


Matte Black Baffle ro T ra I e-
-r: ,u L ljj
lA[.,4PS: 60W A.19 T ro l io r: | : 1r
gow PAB-38 (T-H) MULTIPLE UNITS
100w R-40

for SOW PAR-38 FL (T H) se1i75.Cand1176.Cslrownblow

Max. ceil no thicknessr 1

STEP BAFFLE DC.IC FR ENN K|T toow R-40 FL


9()w PAn.3g
pptrra-
P ecisio't'itted Step ba"re reduces gla e I l02.lC srNoLE uNi-
Wh re fin sn SLitao,e lor damo ocal ol^. ^
REFLECIIOR IRIT'
I176.lG - "i0,
s; 30
I'
Black Step Batfle
10'
MULTIPIE UI{ITS

54 45 aolr:
24 36 33

VERTI-GROOVE DC.IC FRANE.II{ KIT 90w PAR.38


roow R.40 FL FL (Tjl)
PrecisionJilted, vertical y grooved h th{emperature
ple.lolic bafrle leouce5 glare Pe'r']a-While tris'
all02.lC SINGLE UNlr

S! tab e lor damo ocalion


Dia t Lo I Fr [BPdn 0q

s'Irofs-
io iorlT
''uur-rrpr-e
LAMPS: 90W PAR-38 [I-H) I'ULTIPLE UNITS uiiis
ar
8U
6' :6
8

54 / r-l(tFlT(>l-l l= l"
COMPLETE UlllT COllSlSIll OF TWO U BERS: FRAilE.lN KIT A D THER ALLY PRoTECTED REFLECTIOR TRt ,
ORDER EACH NUT'BER SEPARATELY.

DROPPED OPALEX DC.IC FRArrE.l KlT 60w A"t9


(Shower Light) a tlo2.lC SINGLE UNIT
Max mum light output with gaskeled d lfuser of
virtual y unbreakabie Lexant (polycarbonate) Easy REFLECTOR TRITU
1w sllock re amping Suitable for damp location ll78.lC
Opal Lexan
TAMPS:60W A-19 !
o
o
o
I lL" "r'111 1 o
4)0 14 4
u Flo
815 iG
E
o
F
-
0)
o
o
o 0)
E .=
P a)

ADJUSTABLE EYEBALL DC.IC FRAMEJ KIT (o

allo2.lC o -
Accent lghting on horlzonlal and vertca suTlaces oT
downlight ng soped ce ngs. Rotates 358" horzonta y,
o' \(D {-
adjusts 0" to 40'vertca y. Durabe ofe.piece housng REFLECTOR TRI 9
w th matte biack step baflle reduces a are Suilab e for
damp locat on.
1122.,C
Matte White with
Matte Black Baffle
o
o o
LAMPS: l00W R-30

ar lito IllGLE 30" Fno vERttcll.


75W 75W 100w
\E--==/ R,30 R-30 830
)-. 4 )i SP FL
l" . 6'i" _
- 50 193 85
l' t 2.2', f
3.4' 0 9' 2.3',
13 4B 21
2', Bmm rl lH) i 44' 1
6B' 1.8', 4.6'
ADJUSTABLE EYEBALL DG.IC FNAME-fi KIT 6 21
Fu ly adjustab e accent ght for foca lghting on 3' t
1A.2'
6.6'
2.8'
t
6.9',
horizontal and vertical surfaces or down ghling n
soped ce ngs Rotates 358' horzontaly adlusts 0'10 ^ll02rlC
REFLECIOR TRln 3 12 5
10'\^ .d 7.Sut"o" o od-1p o dro' llS2olG 4', Eeam Hl {Hl t
137',
8.8', 1
37', 9.2'
Perma-White FC is i.l
al toolcandtes at cenler ot beam
Beam Heqhr (H) and beam Wdlh (W)are lo the
poi.r rhal the.andrepower drops 10 50% ol
LAN{PS; 10OW R-30

rvax. ceiling tbickness: 1".

lTlademark, General Eleciric Compary. For Guide to Lightlng data, s-^e page 63
r-r(ir-rT()t_t t= t?' / 55
DC.IC Downlights I Thermally Protected

6t%;'0, ce ns openns

ONDERI G LIGHTING DATA

ADJUSTABLE ACCEI{T LIGHT DG.IC FNA E.IT KIT See Lighting Performance Data,
(low Voltage PAR-36 l-amPs) page tr
^rl l02 lG
r
Flexiblltv of appllcalion. Fully adjuslable 358'
horizontally, 0" to 35' vertcaly. Builin transformer REFLECTIOR TRI
and selector switch provide versat lity Jor using 12v or
5.5v. PAR-36 amps, wllh choice of beam spreads.
I l55.lC
Matte Black Baffle
Reqressed lamp prevents glare. Snap- n socket
assures last easy re arnping Suitable for damp I l58.lC
local on. Anodized Satin Gold Cone
l16O.lC
Anodized Satin Clear Cone

LAMPS: 25W PAR36,


55v
25W-50W
PAR36, 12v.
Cilir openiru

l-...6t'
Ma celirE thrckrs: 2'
**--- -':-.--
."--::'- .

Ciling @nirE

ADJUSiTABLE ACCEilT LIGHT DIC.IC FBAIf,E ltl XIT See Ughting Performance Data,
(low Voltage ilR-16 lamps) page 65.
Fu ly adjustable 358' horizontaly, 0' to 40' ^ll02.lC
vert cally. Face of lamp is regressed and shelded by NFLECIOR TRI
back step baffle, to provide excellent glare control.
Bulllin transformer mainlains ful rated life of 20W or
l'l6l .lC
Matte Black Batfle
50W IVR-16 amps whlch offer choce ol beam
spreads. Sujlable for damp ocalion. LAi\.4PS: 20W-50W
t\.4R-16, 1r.

6y,'

56/r-r('r-rror-il=t{
COMPLETE UNIT CONSISTS OF TwO NUMBERS: FRAME-lN KIT AND THERMALLY-PROTECTED REFLECTOR TRtM.
ORDER EACH NUMBER SEPARATELY.

LIGHTING DATA

ADJUSTABLE ACCENT LIGHT DC.IC FRAHE I KIT See Lighting Performance Dala,
(R & PAR lampsf page 66.
Fu ly adlustable 358' horizonta ly, 0" to 30" ^llO2.lC
verllcally. Lamp is regressed and shelded by nEFLECtOn tnr
precsonjltted baff e or cone to prevent glare
Vd-.ras apoed d-,p o Sr6p Bd'- dro'o.la
U27.lC !
do"^,r gl-ts lodop. !' r4l a1o lo',\ ./o,tdga AO rstdop
[,,latte Black Bafile 0
Accent Lighls (page 56) Sutable for darnp ocaton. I'137 lG o o
Anodized Satin Gold Cone o
o
1147.aC
Anodized Satin Clear Cone A
i
LAMPS: 75W F-30 E
90w PAR-38 (r-H)
O)
o q
I -
0)
o
o
o O)
E .E
g a)
g
co
si- o -
'
o !.^
I N
(
C ling Open ng
o
6 o

WALL WASHER DC. IC FRAtYlE.l KlT 75W A.19


Gves smooth wash of ight wthout scalops or
shadows at cei ing ine. Anobriteo reflector system
a llo2.lC Footcandles on
REFLECTOR TRIM wall from
and matte back band assure maxmum ight output multiple units
and m nimum aperture br ghtness w th 'A amp. 1136. lC
Suitable for damp locat on Matte Whlte and UNITS 2'FRON,4 WALL
Matte Black 2',

LAMPS: 75W A-l I


30 34 3A 122 22 22
27 3A 2l t19 16 T9
l8 1B 18t12 12 12
13 12 13 17 I 1
8 8 8t 4 6 .1

5 6 5:3 4 3
5 r 5!3 4 i
4 4 413 j 3
J 3 3t 2 2 2
Fro 0aid e yi res arc a!eraqed ard rdNined olJ and a.e ba3ed

1r:n lr0sc slorrr dse rir:nrnr 01 i 10l soacnq idislafce


Max. ceil nq lh ck.ess 1
trrlr!-'9f ilrrre\ d (anro10 Llaii lor beil
'estrh
For Guide to L ght n9 da1a, see page 63 (r
r- | Fr T() t_t t= t?" / 57
7 . {1 DG r lG Downlights
rt
-Litt
O'%, dia cerling openrng
U.L. Listed for Direct Contact with lnsulated Geiling Materials
FRAME.IN KIT
A1l94.lC Dc.rc THERMALLY
IcCESSORIESI
PROTECTED FRAl,4E-lN KIT lncludes: 13" F<_) '1961 Plasler Frng
mounting bars which can be extended 10
27"; mounting frame; snaPin socket and 1956 T.Bar Anchor clFs
For anchornq mounllng bafs lo T Bars
socket cup wired to junction box; thermai
protector; No. 18SF-1 leads; liberglass i-:r 1964 2a" Mounlrng Bars sel oi 2
For erlrem,o oilcenler postlonirrg in ?4'
insulation barrier; anchor clips lor existing
ceilings. U.L. listed for through branch
circuit wiring. t 1965 Concealed splne ceilrng Kt
Sel of ,1 For ceiiirg runners up to 21r, "
above f njshed cerling.

JUNCTION BOX
MOUNTING BAR(S) a Easily accessible from
a For wood joist or both sides; J-Box is parcllel
suspeoded ceiling; exiends to mounlinO bars.
up Ia 27". a Saves iime and expensel
a lvlaximum strenqth buil!in cable clamp. ground
prevents saqqino. wire, pry.out knock-outs and
a 20" lMounling Bar saiety-edged covers.
Extenders-Sei of 2 . tJ.L. listed for Through
(Accessory No. for off-
1964) Wiring {2 in-2 out, 60"C).
cenier posiiioning of . U.L. listed for Damp
mounting frame between Locations.
joists spaced up to 24".
. Concealed Spline Ceiiinq
Kit (Accessory No. 1965) ior
use with conceaied ceiling
tunners_ REFLECTOB TRIM
f
a T-Bar Anchor Clips o lv4atch Non .C. refector I

{Accessory No. 1956) anchor tr rrs 1or cons stency of


mounting bars io T Bars. appearance.
. Shal ow. On y 5 r,j deep

BREAK'OUT SECTIONi
ANCHOR CLIPS
a Works in existing
ceilings. Permits frame
to be put easily
through ceiling
a SOCKET CUP
a Franre-ln Kit
FLANGELESS
MOUNTING FRAME
opening. Push-in 1194.1C, with thermal a Versatile. Works for
anchor clips (supplied) protector insures both new and existing
secure flame. against overheating ceilings.
?l{? .t*J
due to incorrect
lamping.
a Time-savinq
installation. Opening
ANCHOR CLlPS can be cut alfer ceiling
is installed.
a Assures clean, neat
installation, acis as
precision cutting
'lemplate.
SNAP"IN
SOCKET a No sharp edges.
a For plaster ceiljngs,
use Plaster Rino
(Accessory No. 1961).

58 / t-t(-t-lr()l-l l= l?"
COI{PLETE U IT CONSISIS OF TWO IIU BERST FRAitE.tN KtT A}tD REFLECTIOR TR|H.
ORDER EACH NUI{BER SEPARATELY.

ORDERING LIGHTIl{O DATA

DG.IC FFA EJ 75W R-30 FL


p::ils il'-i"i3ffll:ltYi'flJot, nno
KIT
Qr,ffi ,}T#.!5fi "'f#;,:ls:*?: "
^tl94.lC
Thermally Protected

REFLECTON TRI
l19l Perma-White

LAMPS: 75W R-30

STEp BAFFLE. Prec sion f tted, high heat phenol a step baff e reduces DC.IC FRA E.I}l KIT '75W R-30 FL o
o
glare Perma-Wfi te rel ector. For use with 75W R-30 amp. Suitab e lor damp s'rolE ui'i .=
. a
lFu i,tl 0)
locat on.
^ll94.lC
Thermally Protected
g 13 I
o
o
E
I o
I REFLECION TRIM t0 1 13' E
.
1189 Black gattte
ii , I ,o o
o o
o (!
1 LAlvlPS: 75W R-30 -
L"qi F.Tsm r., o
4',
o *
,,
6
I
1,o
r- | l F o
VERTI.GROOVE. Prec sionj tted, vert cally grooved h gh.heat phef o c DC.!C F tAt E.t KtT 75W R.30 FL
baffle reduces glare Perma-Wh te relector. For use with 75W R-30 arnp.
Su tab e for damp ocat on.
^1194.|C
Thermally Protected
8
NEFLECTOR Tnl
I196 gtack verti
Groove fULTIPLE UXITS

Cr ro FmrtiPr
LAI\,IIPS: 75W R3O tr ir p m,t pm

a l50 a"
6l22 l1e
a r: I l
DROPPED OPALEX (Shower Lightl. casr,eteo drruser of DC.IG FFA E.III KIT 40w A.tg
vilLalv ulbreakable lprant {polycd.oolateT B te-Dip re-lec-o. SIXOLEUNII
e"icielcv wil lOW A-'9 lamo. Edsy rwistrock 'erampi^g. Su rablp lo
assLl.es
l94.lC r. l, ri
FL ,liL lH,imi-
d?'11n lncari^- ^l
Thermally Protected
8 I 1,, "

REFLECIOR TRI r0r2.


'1199 opat rexan rz L 06 | 1' I

':-------**.=.---*.. 'r'^srle!E li'rt


LAMPS: 40W Al9 an r.
r lL e n' ls", r
r I ro I z

uar. ce llng th ckness l


"t.t
u ,l-
ADJUSTABLE EYEBALL. Fu ly adjustab e accent ight Rotates DG.IC FRA E.IT KIT
35B' horzontaliy adjusts 0" to 40'vertica y Perma-White relector. For use
wth 75W R 30 arr]p. SLritabe lor damp locaton.
^ll94.lC
Thermally Protected For lighung
data, see dala
for Adjuslable
NEFLECIOB TRIM Eyebal 1182
{ 193 Perma-wnite page 51.

LAMPS: 75W B-30

i lrademark Gen-ara E eclrc Compafy


For Guide to L ghting data, see page 63. r-r(tFtT()t_t t= t"./ 59
Series 18OO Surface and Wall Mounted Downlights

47r" f 6"d, "v,nd",

CYLINDER DOWNLIGHT
Seamless, one-piece alum num
cylinder gives concentrated
down ight with "R" or "EF"
,mos choice of matte back.
matie white or bronze linishes.
Black aperture reduces glare.
Suitable for damp location.

CYLI]IDER DOW]ILIGHT
Seamless, one-piece aluminum
cvlinder rn matte black, matte
whrte or bronze f nish with b ack
aoerture which reduces glare.
Gives ample downlighl with "R"
or "PAR" lamps. May be mounted
on 36" ong stems whlch can be
cut to length on the job. Suitable
for damp ocation.

WALL BRACKET
Rugged onepiece alum nim
cylinder gives amp e downl ght
with R'l 'ER" or "PAR lamPs.
Choice of matle black, matte
white or bronze finishes with
black aperture wh ch reduces
qlare. Suitab e lor wet location.

60/t-t(tFtr()l-ll=ll.
o
t
l82l Matte gtact< 75W R.30 FL
ltxorE ir
75W ER.30
!o
1823 tr.latte wtrite I- ro-T .r 'J o-
'1826 gronze Fmr ra;
Beam
rl- o
I 14 I 60 IF" !
o
LAMPS: 75W R-30 / ER-30 ro ] 8 i rrr3 10' 32 4'.
r2 5 f
I | 12', 20l5'
-
o
MUITIPLE UNIIS SULTIPLE UNIIS
G
; !)
35 ! !
r6 (!
>.

.!
io

l8Ol
1803
H,,tatt-" gracr<
varte wnite
t50w R.40 FL I5OW PAR.3A FL
o
o
o
o
NrroT - lBeaiiDa o
;e
l SOO
t
aronze Fror I; Li;.eflm o
8' 49 6'
LAMPS: 150W B-40 / PAR-38 3
STEM KIT 5\" Dta.
accEssoBtEs Canopy ULTIPI.E UNITS ULIIPLE UNITS
Sellalignina swivel pro-
vides 28" vertical li" Dla
adjustment. 36" long Slem

stem.
7249 r,ratte wnite
7259 vatte stack

l84l uate aacl


1843 tvtatte wnite
1846 Bronze

LAMPS: 75W ER-30


100w ER-30
IUlttPt! urII! IULflPL! Ullrt!
SR = 05

l83l watte etact t50w R.40 FL t 50w paR.3a FL


-- $xoiE uxr"
1833 t,tatte wnne
1836 gronze ror 1-,,,0 mr
8'l146 l3'
LAMPS: 150W R-40 i PAR-38 10' ]n 4'

uttns
-iiur-rrpr.e
Clr

7, ge Igg--
32

For Gu de to L ghl ng dala see page 63 t- t(tFrT() r-r t= tr-" / 61


AGCESSORIES LAMP DATA
Accessory Cat. No For Use with
Rated Rated
ptrltEn Rll.o 1959 rrame-tn Kits 2002, 2Do2P'1 Watts Bulb/Base Lumens LiJe

196O
Housings 2052, 2053

rrame-tn Kils '1002, 1(n2P1 OEI{ERAL SERVICE LAIP3


(lnlt al) (Hours)
G
l96l Frametn Kits 1102, 1102'lc,
40W Al9/ Med. 455 1500

1102P1, 1194.1C 60W Ar9/[.4ed. 870 1000


7sW Al9 / N,4ed. 1T90 750
{962 rrame-tn KiIs 1202, w2P1 100W A19/[/ed. 1750 750
150W A-21 / Med. 2850 750
lxTn W|DE /^\ 1954 Fixture series 1102* 200W A'23 / Med 4010 750
FLAIIOE TRII K-:-: )) .except 7'11
fl o PROJECTOR (PAR} LA PS
195? rixture series 1m2
75W PAR 38/Med 765 2000
1958 Fixture series 't202 120W PAB 38/ lVed A7A 2000
150W PAR-38 / Med. 114A 2AAA
REitrxtxo cuF3 1955 Pixture Series 2ooo, '10oot, 1420
(Bo( of 100) 1100r. 1200
90W PAR-38/[,4ed. (T-H) 2000
For installation on 1s0W PAR 38/N,led. (T-H) 1900 4000
existing ceilirEs. 250W PAR 38/ Med. (T-H) 3s00 6000

T.tlt axcHon /? <f,L 1956 All Frame-ln Kns r.ow VOLTAOE PROJECTOR LA PS
CLIPa (Set ot 4) lfJt
* -."Atr> and Housrnss 25W PAR-36/Scr. Term
For anchoring (s.sv.)
mounting bars to
T-Bars. 25W PAR-36/Scr. Term 2000
(12v )
20" f,ouLtlllo 1964 All Frame-ln Kits 35W PAR-36/Scr Term
3AN IXTEXDERI and Housings (.12v.)
(Set ot 2)
36W PAR 36/Scr. Term 2500
For off-center
positioning ol (T H, 12v.)
mounting lrame 50w PAR-36/Scr. Term
(12v )

cotlctaLEo 1965 Al Frame-ln Kils


lVRl6 / 2 Pln
(T-H, 12v.)
,,*G
and Housings
cttllxo
'PLIXE xrT tVBl6/ 2 Pin 2500-
(Set of 4) (T'H, 12v.) 3000
For ceiling runners
MR.16/ 2 Pin 3000
up to 2%' above
finished ceiling. (T-H, 12v.)
75W lV-16/ 2 Pin 3500
IHIRTAL
PhottcfloR
l97O rrame-tn Kits 2oo2P1,
1002P1, 1102P1, 1202P1
NEPLACE EIII Housings 2052, 2053 REFLECTOR (R} LA PS
xtt 30W R-20/Med. 21A 20AA
50W R-20 / Med 44A 2000
SLOPED CElLlllo ADApIERS for New Ceilings Only 75W B 20 / Med. 800 2000
Forproviding --Ll 5 75W B 30/Med. 900 2004
down{ighting 1.'i. .,,,i- 100W R 30 / Med. 1200 2000
lrom sloped i 1!..i--- ---:'a'\
ceilings. '' I i:=-:j 75W 8s0 2000

t
R-40/N.4ed.
100W R-40/[/ed. 1T50 2000
F:i#::JXX" 150W R-40/ Med. 1900 2004
1102, 1102P1,
1102.lC and 300W B-40 / lVed. 3650 2000
1194.|C. White adapters +
match trim flanges of iEcEsGD OEPltl FEOUlaElllEl{ta ELLIPSoIDAL REFLEGTON (ER} IA PS
fON i|XN'FEA IVIT|I SLOPED CEILII{G ADAPTEFE
fixlures. Templale Foa 1102,1102P1,119a.r I Hh rr02.E .J sow LR-3O/Meo. 525 ,l-r(-ru
supplied. dddne desn
ro dsemine
Io
qued add 5
d.Dft I oromoe
a.eren dprh olsmlne @ftrsfd
io reiedror I tm
@{ defln rqurei
lado iFlow f, ) zsw EB-3o/Med. B5o 2ooo
rrn tuohr I /z
COl{PACT FLUORESCE}IT LAI{PS
9W PL or TT/2 Pin 600 10000
13W PL or TT/2 Pin 900 10000

'l'e .1dp" o'a o-o iloicdleo o) a e or o <o e dl al'


lerr s-cn ds A q oaq .l l1e 5/" i. giler b/ "
n-moe wl ic- e O .S\a lre ordFle| p gh.' . T'L). -
an R-40 bL o 15 o r-ra a rt apd, r0 o q-r . 40 8) o' 5"

62/Lr(tl-lT()l-lt=le,
GUIDE TO LIGHTING DATA

DOWNLIGHTING SINGLE UNIT E^amPlP


' - 1005 75W R.30 FL
lll i0 Bean Da A s nq e 1005 Bellector Trim uf t w lh n 75W R 30 FL amp
mounled n an I h gh c-" n9

B 14
TO ll The ghling eve d recl y benealh lhe f xtLfie and thc beam
12 5 13

Footcandle (F C ) values are init a and are at the See Sfge Unlclrart The ichtnq -avc s 1.1 footcandes beneath
center of the beam. 30" above the floor The Beam lhe l xllre and the beam d ameter is S BolhvaLrcsareal 30
Dlameter s to the point that the cand epower drops abovc the loor
to 50% of max mum.

DOWNLIGHTING MULTIPLE UNITS


'
I OO5 75W R-30 FL The Spac ng Rat o (S B.) s used to deterr.|ne the max mum
SR=09 spacing of fixlures for even I ght ng by mu tp y nq the Spac nq
lr Fd O I . 11^ ^ioh .oO.. .a ptdnp
llrr
l'.
l0 Br
^or.
Ex a m pl-o
4 28
'l 6 l6 l3
Use 1005 F-"1ector Trm unts,/r'th 75V,/ F3| Ft amDs n a srna
I 8 I 7
room wth an I
hrrth v/h le c-o I fq af d qh1 lvat!
Footcandle va Lres aTe in tia and averaoe and are
d dVO-Oor^rog O O OO.o rha OO A, The spac nq ol lxlL|es lor 25 10 :lt) tooicand es irf r a
d p ro^ Or .d o.
)
. ,- p., ,q I rtd.q-
'oon .0 0, io ,1 I oo ro /,,ao'\ Se-" [,4ulpe Unrls chart Thcse f x1!res ntoLrft,ad o| 4' cenlers
6r,, g r--!l o I o Poo r ' ro o,o o o o,e
^rircal wh te cei rg (80% ref ), I ght wal s (50% I d.8 o o. I or r0
typ ' i ooo.oo O^ o ar o ,, . ,. o. q O.
refl ) and dark f oor (2011 ref.). ufform qhtnq = 03i{825) = 495.1r io.lr

RECOMMENDED LIGHTING LEVELS LIGHT LOSS FACTORS


(Minimum, Maintainedl ll.. reNanrP lln.r I n.q
HIG H: M EDIU M: LOW:
Over 50 30-50 Less than Erc osed
/5 70 60
lootcandles lootcandles 30 footcandles Down Chls
. Kitchens . Lobbies. . Corridors, 0pei PAF I] ER []R ilI 15 la
. Reslaurants, . Restau ranls . Elevators Dowrl ghls 7A
(quick serv ce) (le sure type) . Sta rs.
Good = c eaf erea ar nra ftenafce afd qro|l
. Stores . R_6cf-aaf on . Restau rants, Medium= .o o
T-o{.1!
.
re anrll tq
.
rl p.
Areas (lntimate types) Poor=drlyarea poor rr.r r1lenanc-a i td spol r-oanrpnrj
. Soc a Areas
LEht oss Iaclor! comDansale for d rl aacL|ll!i11ol aIc afipd-oprccalon
To oblarn marrlafod ioolcarfale v;iLtas nulov tla foolcirn(la vnLr-os
bv th-" l;rclors :rb.v-"

ACCENT LIGHTING BEAM CENTER LOGATION


'
30' AIMIXG ANGLE 45' AIMII{G AI{GLE The charts locale the d slance (C) to th-6
center of the lght beam for var ous
^o, od ^ D, d o o, trng
ang es 30' and 45" from verttca 30"
Ol .d li d rl 6 O ata 60 .r I.g
ang e lor ightlng p ctures on a wa l

txamp e When an accent ght s ocaled


3'from a wal and a med 30' from
verlical, the cenler oi the ght beam wi
be about 5'do\'vn lrom the cerlinq.

t-t(ir-rT()t-lt=ta,/ 63
Lighting Performance Data: Low Voltage lamps
PAR.36
lamps 25W PAB36 {5.5U 25W PAfiIE VNSP 35!1 PAR{6 SP 36W PAR 36 VNSP [H) 361V PAr 36 NSP {iH)

32
3a
5
ffi:
ffiil
ffi
+ffrtJ
tTffi+]
ffi ffi
fTlllt .

FoCICANDIES (0n Beam Cenler Al 6') 833 458 50 556


BEAM SPntAo fio 50i6 Mar.

lirAx MNDLEPO!'!R

COLON TEMPEMI1NE

0. ATMTNG i 202 0.7'


ANGLE .,-,-- D 257 A3' 0t' 117 0B/ r0'
66 1]',
200 0.s,
89
0.9'
90 1.0,
1.2'
1.8'
lilum naton on
1.3',1.3',
!/_- S> ',,' 114 0.5', 10'
65 0.7', 14', 42 14'
14',
50 1.7' 1i' 50 1.4',2.4',
Ho|zonial Plane
1.1'
,r-- 42 0.9' 1T' 29 1.7' 2.1' 32 2.2', 2.2', 32 11' 3.1',

30' AI ING
ANGLE 304 03', 0.2', r30 10, 12' r33 1.2'1.0' n5 0.7' 11',
135 04' 0.4' 47 16t 20', 68 1.6' 1.4' 91 1.1', 17',
76 0.6' 0.5', 24 23' 29' 41 21'1.8' 51 1.5'23'
49 07' 0.6', 14 3.0/ 37/ 27 26', 2.2', 33 1.v 2.8',
r:o
3oo
ANGLE
ATMTNG
".i aF 156 14' 0.7',
td lr 69 21', 1o',
lliumrnatron on t l. 39 28' 1.4'
Ven cal Plane 'wt ?s 35' 1.7'

PAR.36
Lamps 5$! PAR{6 NSP I 25W PAN'36 WFL 361! PAR36 WFr 0H) 5O PAB.36 WFL

!;:
i r,{ti,
I 1/ t++] \'8

F00TCANDLES (On Eeam Cenlr Al61 >


3.
+tu1rffi
247 I 14
Lt.A \
JJ
BEAM SPREAD (lo 50qb fi,lar. CP)

MM. CANDLEPOVIEN

COLOB TTMPERATUfiE

O" AIMING
ANGLE J25 0.9' 10' 144 15', r g',

lllumination on 31 1.8', 19' 5? 2.5', 32',


14 28', 29', 27 35' 4s',
I 37' 3g', 16 45' 58'

30' ATMTNG .l"i


aNGLE *t#i',, 16'17',
24',25'
llluminalion on " L-+-:.--
!- 33'3.4'
HorizontalPlane + I 41'43r

30O AIMING 163 2 5', 14', /5 4.0 1.5',


ANGLE 4l 4.9', 2 8', 19 8.1', 29'
llluminalion on 18 14,', 42', 8121',4.4',
10 9g', 56', 4 161' 59'

Data are based on bare lamp pholomevics.


oashed llnes in bearn spreads rndicale narrow axes ol oval shaped bearns
FC is nitial iootcandles al cenler of bearn L and W are lo the polnl lhal the candle power drops lo 50o/o ol max nr lrm

Beam Gontr Locatlon


1 c
oislafce C (fl) 1l
I
Th6 charl locales th dlstance (C)lo lhe c4nler ol lh liaht beam
lor various distances {0)v{hen lhe lamp is aimed 30o lrom vencal,
the prelerred aiming anole lor lilhtifg picturcs on a wal

64 / t-t(t Flr(> t-t t= IrJ


Lighting Performi
MR.l6 PAR-38, R-20,
Lamps 20 MRr6 VI\|SP 2O MRI6 NSP 41I MR.16 VNSP 75W MflI6 NSP R-30 and R-40
Etj tsx Efr EYT
lamps

ffi ffitffi
ffi ffi
\,a
3;. ad
5 H{*ffi 5',
BEAM SP8EAD 0o 50qt Mu CP)

FooICANoLES {On 8'"am Center At 6') 250 92 .JJ.' 319


BEAM SPREAD Oo 5OCt MaT. CP)

MAX. CANDLEP0WEF (Candelas)

COI-OR TEMPEMTURE

06 AIMING ,'I,
ANGLE *l!- ? 184 0.6' 0.9' 1.0, 14, 187 1.3' 1.6' 1N 2.0' 21'
liurnrnaton on ! Efq-] t' s0 0.s'1.2, 14' I B', 92 1.9' 2.3' 80 2.9' 32'
53 1.1/ 1.6/ 1.7' 2.3' 54 2.5' 3.0' 45 3.9' 42'
35 1.4' 2.0' 2.1' 2.7' 35 3.1' 3.6' 29 4.9' 53'

30' AlillNG foi


AI'IGLE 165 1.5' 1.6'
llluminalion on 73 23' 24'
41 3.1' 3.2'
26 39' 3.S'

3OO AIMING PAR.38, R.20,


ANGLE
llluminalion on R-30 and R-40

MR.l6 BEAM SPREAD 0o 504t Max

Lamps 5OV MRT6 NTL


EXZ
50/1 MR.t6 FL
IxN
75!! MRI6 Ft
EYC

o 8,,
t;;
5',
ffi
t7lttl
4t
5',

F00]CANDLES (0n Bearn Cenler Al 61 > 56


EEAM SP8EA0 0o 50qt Mar CP)
MAX. CANDLEPo1 ER (Candelat

MTED LIFE {Hou's)

COOR TEMPEMTUEE

OO AIMING
ANGLE 125 2.8' 2.9'
56 4.1' 4.4'
31 5.5', 5.8',
20 6.9' 7.3' PAR.38, R-20,
300 A fiNG R-30 and R-40
ANGLE 75 1.8'
19 3.6',
I 5.4'
5 7.2'

F0oltANDLiS {0n Beam Cenlo{ Al


3OO AIMING
ANGLE
lllurn nalion on
21 12.1'
12 16.1'

Dala ar based on bare amp photometrlcs


Dasheo [nes . oeam rd cale 1a ow a rps ol o! al snapeo bea-.
FC s rn t al loolcandles"p'eads
r

at center ol beam L and W are to the point thal lhe candle power d rops lo 50qo ot rnaximum

l
65/l-t('t-tT()t-tEtlj
Performance Data; Line Voltage lamps

;,3
;,d

190 23', 2.3',


84 34' 3.4',
47 46', 4.6',
3A 51'. s.t',

383 1.7' 1.5'


110 2.5' 2.2'
96 3.4' 29'
61 4.2' 3.6'

167 26'1.3'
94 3s',1.//
60 43' 2.r'
42 52' 251

M6dlum
75!! PAi.38 FL 90 PAR38 Fr (rtl) 150/r q { sP

116 ?.1' 21'


52 3.2' 32'
a $, 43'
19 5.4' 54'

168 3.5' 1.6' 278 39'1.1'


15 5.3' 2.3' 124 5.9' 2.61
42 7.4'3.1' 1A t.9, 3.4'
27 8.8' 3.9' 45 9.8', 4.3',

Wde
100,V 8 30 250irv Ptc.38 FL [tH)

llhftt+
t_8
l#tl
Llt] + l\-t-.]
LltlI t\t l
200

133 1.4' 1.4' 26 1.7' 1.t' 170 2.3' 2.3' 116 4.7'47' 122 64', 64',
33 2.8' 2.8' 52 3.4' 3.4' 43 46'4.6' 42 7.8' 7 8' 54 95/ 9.5'
15 4.1'4.1' 23 5.1'5.1' 19 6.9' 6.9' 21 10.9'10.9' 30 121'12.1,
I 5.5' 5.5' 13 6.8' 6.8' 11 92t 9.2' 13 141'141' 20 15.S'r5.9'

114 3.5' 2.7'


21 6.9' 5.3'
12 10.4' 8.0t
/ 13.9'10.7'

66
)a

Potrebbero piacerti anche