Sei sulla pagina 1di 2

MULTIPLES OF LONG-TIME PICKUP (L)

10000
1000

2000

3000

4000

5000
6000
7000
8000
9000
100

200

300

400

500
600
700
800
900
.5 .6 .7 .8 .9 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90
1000 1000
900 900
800 800
700 700
600 600
500 500

400 400

300 300

200 200

Long-Time
Delay Bands
Ma

100 100
90 90
xim
Int

80 80
erm

um

70
Min

70
edi

60 60
imu

ate

50 50
m

40 Maximum Total 40
Clearing Time
30 30
TIME IN SECONDS

TIME IN SECONDS
20 Minimum Total 20
Clearing Time

10 10
9 9
8 8
7 7
6 6
5 5
1.75L

4 4

3 3
2L

3L
2.25L

2 2
4L
5L
2.5L

Low-range High-range
6L
Short-time Short-time
1
Pickup Points 8L Pickup Points 1
3L

.9 .9
.8 10L .8
4L

.7 .7
GES-6033B

GES-6033B
.6 .6
.5 .5
.4 Maximum .4

.3 .3
Short-Time
Intermediate
Delay Bands
.2 .2

Notes:
Minimum
1. Short-time-delay element is optional.
.1 The instantaneous element may be omitted. .1
.09 Instantaneous .09
.08 4L 12L 2. For 50 Hertz operation of the following breakers .08
.07 Pickup Points equipped with Ground Trip element, the Short-Time .07
.06 and instantaneous pickup settings should not exceed .06
.05 the following maximums to avoid ground error signals .05
possible due to sensor saturation.
.04 .04
Sensor Tap Max. Pickup
Breaker Setting Setting
.03 Type (Amperes) (Amperes) .03
Application AK, AKR-50 1200 14,000
Determines 1600 18,000
.02 AKT, AKRT-50 1600 16,000 .02
End of Curve 2000 20,000

.01 .01
.5 .6 .7 .8 .9 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90
100

200

300

400

500
600
700
800
900
1000

2000

3000

4000

5000
6000
7000
8000
9000
10000

MULTIPLES OF LONG-TIME PICKUP (L)

GE Consumer & Industrial -


Electrical Distribution
Low-Voltage
Power Circuit Breaker
GES-6033B
X-Current Sensor Taps (Amperes) Type AK/AKR Programmer Set Points
AK-15 70, 100, 150, 225 SST Solid-state Overcurrent Trip Device Pickup
AK-25 70, 100, 150, 225 Long-time-delay, Short-time-delay Long Time:
or 200, 300, 400, 600 0.6, 0.7, 0.8, 0.9, 1.0 and 1.1 multiples of current
AKR-30 100, 150, 225, 300 and Instantaneous Time-Current Curves sensor tap setting (X). (Settings higher than 100%
or 300, 400, 600, 800 of the frame size do not increase the continuous
AK AKR-50 300, 400, 600, 800 Curves apply at 50/60 Hertz and current rating)
or 600, 800, 1200, 1600 from -20C to 70C Programmer Ambient. Short Time: 1.75, 2.0, 2.25, 2.5, 3 & 4 or 3, 4, 5, 6,
AKT AKRT-50 800, 1200, 1600, 2000 8 & 10 multiples of Long-time pickup setting (L).
AK-75 1200, 1600, 2000, 3000 For 50 Hz operation, see Note 2.
AKR-75 1200, 1600, 2000, 3200
Instantaneous: 4, 5, 6, 8, 10 & 12 multiples of Long-time
AK AKR-100 1600, 2000, 3000, 4000
pickup setting (L). For 50 Hz operation, see Note 2.
Time Delay Bands:
Long-time and Short-time: Max., Int. & Min.

5.80 3M