TOPOLOGY SELECTION OF THE OUTPUT CONVERTER IN AN OFFLINE SWITCHING

POWER SUPPLY (SMPS)

ASSUMPTIONS:
YES
Po>2500 W ? 1. Input voltage: 120 to
400 VDC (which is
typical for rectified AC
USE SEVERAL INTERLEAVED line voltage or the
NO CONVERTERS WITH
INDIVIDUAL POWER <2500 W
output of PFC boost)

2. Output voltages <60 V


YES
Po>1000 W ?
NOTE: This is just a
basic guidance in
selecting proper smps
NO 9 ZVT FULL BRIDGE topology, which is
based on the author's
personal view.
YES
Po>400 W ? The right topology will
be selected depending
9 HALF BRIDGE on specific
9 2-TRANSISTOR requirements for the
NO FORWARD power supply (including
9 FULL BRIDGE cost and time factors)
and personal
YES experience of the
Po>250 W ?
designer.

9 HALF BRIDGE
NO 9 2-TRANSISTOR
FORWARD NOTES:
Po- overall output
YES power,
Io>10 A ? Io- maximum current of
any output

9 SINGLE ENDED
NO FORWARD

9 FLYBACK
9 SINGLE ENDED
FORWARD

2003-2006 Lazar Rozenblat


You have permission to post this file on your website provided you leave the above
copyright notice. You may also reproduce its content elsewhere if you give credit to
http://www.smps.us/