Thomas Flohr
Head of CT Physics and Applications
Alexander Zimmermann
Global Product and Marketing Manager High-End CT
15.10.2005
3
SOMATOM
DefinitionExcellence in CT
4
SOMATOM Definition
Excellence in CT
z-Sharp CARE
STRATON
Unprecedented Image Quality and Detail
Lowest Patient Exposure
Engines
Diagnostic Speed and Confidence in CT
Clinical
DSCT
Explore the New
Trends with Dual Source
5
z-Sharp
Unprecedented Image Quality and Detail
6
SOMATOM Definition
Unprecedented Image Quality and Detail
7
8
SOMATOM Definition
Unprecedented Image Quality and Detail
STRATON
Combination of industrys fastest gantry rotation speed of 0.33 s
with DSCT enables motion artefact free imaging
z-Sharp
at highest volume coverage
at any position within the scan field
with no increase in dose
Previously unknown sharpness and clarity
with complete spiral artifact elimination
z-UHR
Ultra-high resolution bone imaging with 0.24 mm isotropic detail
9
Clinical
Engines
Diagnostic Speed and Confidence in CT
10
SOMATOM Definition
Diagnostic Speed and Confidence in CT
SOMATOM
Definition
syngo CT.3D
syngo applications
11
DSCT
Explore the New Trends with Dual Source
12
Multi-Source CT
Utilizing a well known idea
SOMATOM Definition
Excellence in CT
SOMATOM Definition
SOMATOM Definition
The Worlds First Dual Source CT
Faster
Faster thanthan
Every Every Beating Heart
Beating Heart
Full Cardiac
Full Cardiac Detail
Detail at Half theat Half the Dose
Dose
One-Stop Diagnosis
One-Stop Diagnosis in Acute Care
in Acute Care
Beyond Visualization
Beyond Visualization with Dual Energy
with Dual Energy
17
Faster than
Every Beating
Heart
Explore the New Trends with Dual Source
18
Single Source CT
Temporal resolution of maximum 165 ms
Temporal Resolution =
Rotation Time 330 ms
=
2 2
= 165 ms
19
Single Source CT
Technical challenge with high heart rates
60 bpm 120 bpm
20
SOMATOM Definition
Heart rate independent temp. resolution of 83 ms
Temporal Resolution =
Rotation Time 330 ms
=
4 4
= 83 ms
21
SOMATOM Definition
Reliable imaging of all heart rates
60 bpm 120 bpm
22
Temporal Resolution =
Phase Shift Rotation Time 330 ms
=
2 2
= 165 ms
24
200
Temporal resolution in ms
180
Single Source CT, 0.33s
160
140
120
100
80
60
40
50 60 70 80 90 100
Heart rate in bpm
SOMATOM Definition
Dual source CT: A quarter gantry rotation is
sufficient for an image
Temporal Resolution =
Phase Shift Rotation Time 330 ms
=
4 4
= 83 ms
SOMATOM Definition
Dual source CT: stable 83 ms temporal resolution
220
200
Temporal resolution in ms
180
Single Source CT, 0.33s
160
140
120
100
SOMATOM Definition
80
60
40
50 60 70 80 90 100
Heart rate in bpm
SOMATOM Definition
Evaluation with simulation study
SOMATOM Definition
Evaluation with phantom study
SOMATOM Definition
Faster than Every Beating Heart
Full Cardiac
Detail at Half
the Dose
Explore the New Trends with Dual Source
33
SOMATOM Definition
Full Cardiac Detail at Half the Dose
2 x Sources
= Dose ?
34
SOMATOM Definition
Faster acquisition at higher heart rates
SOMATOM Definition
Cardiac CT at half the dose
SOMATOM Definition
Cardiac CT at half the dose
200% DSCT
Non-optimized
150%
Single
Source
100%
50%
SOMATOM Definition
Cardiac CT at half the dose
DSCT Focus
200%
Non-optimized
Additional
150% + Cardiac cardiac
Single bowtie
bowtie
Source Regular
100% bowtie
50%
SOMATOM Definition
Cardiac CT at half the dose
Overlapping
Spiral Images
z - Position
Recon
Recon
Recon
Delay
Time
Time
Low heart rate = low table feed for continuous volume coverage
42
SOMATOM Definition
Cardiac CT at half the dose
Recon
Recon
Recon
Time
Time
High heart rate = high table feed for continuous volume coverage
thanks to restriction to single segment reconstruction
43
SOMATOM Definition
Cardiac CT at half the dose
50%
SOMATOM Definition
Cardiac CT at half the dose
Recon
Recon
100%
Current
Single source CT
20%
Dual source CT
Time
45
SOMATOM Definition
Cardiac CT at half the dose
One-Stop
Diagnosis in
Acute Care
Explore the New Trends with Dual Source
47
1 x Power 2 x 80 kW
SOMATOM Definition
The power of two sources
Single source CT
SOMATOM Definition
The power of two sources
Routine use
Obese
DSCT
Single source CT
SOMATOM Definition
One-Stop Diagnosis in Acute Care
SOMATOM Definition
One-Stop Diagnosis in Acute Care
SOMATOM Definition
One-Stop Diagnosis in Acute Care
Explore
12s theprotocol,
Chest Pain New Trends with Dual Source
independent of the heart rate
55
Beyond
Visualization
with
Explore the New Trends with Dual Source
Dual Energy
56
SOMATOM Definition
Beyond Visualization with Dual Energy
80kV
Bone
670 HU Iodine
296 HU
Bone
450 HU Iodine
144 HU
140kV
57
SOMATOM Definition
Beyond visualization with dual energy
Mean Energy:
56 kV 76 kV
Tube 1
Tube 2
SOMATOM Definition
Beyond visualization with dual energy
SOMATOM Definition
Beyond visualization with dual energy
SOMATOM Definition
Beyond visualization with dual energy
SOMATOM Definition
Beyond Visualization with Dual Energy
DSCT opens the field of dual energy research
Potential applications: - Dual-energy bone subtraction
- ........... ?
63
SOMATOM Definition
Excellence in CT
z-Sharp CARE
STRATON
Unprecedented Image Quality and Detail
Lowest Patient Exposure
Engines
Diagnostic Speed and Confidence in CT
Clinical
DSCT
Explore the New
Trends with Dual Source
64
Questions
and Answers
65
siemens.com/
Dualsource
66
siemens.com/Dualsource
67
siemens.com/Dualsource
68
of your customers
should register
69
Questions and
Answers
discussion Board
Register yourself
Review latest
materials and
Q&A
Competition
to the SOMATOM Definition
71
72
Whats More?
73
SOMATOM Definition
Installation Requirements
Gantry weight: 2700 kg (700 kg > than S64)
Higher static pointload of Gantry floor: 8000 Nm (S64: 5140 Nm)
Power consumption: 255 kVa (using w/w, S64: 104 kVa)
Minimum size: 26.5 m 2 (3.5 m2 > than S64 ;
1 add. power cabinet, but w/w cooling build in gantry: in total)
SOMATOM Definition
First Installation
Target
for the Fiscal Year 2005/2006
76
Units
77
Making
of SOMATOM Definition