ELECTRICALPOWERENGINEERING

Power Transmission and Distribution



Themajoradvantageofacandthreephasetechnology Variousvoltagelevelsareusedfortransmittingpower;thelevels
over dc technology is that the electrical power is are determined by the amount of power and the distance; the
generated economically in large power stations higherthetransmissionvoltages,thelowerthecurrentsaswellas
relatively far from the end users, transported at high thetransmissionlosses.However,itmustalsobeconsideredthat
voltage over long distances with very little power loss networkinvestmentcostsincreasewiththevoltage.
and finally made available to the consumers the way
theyneedit. Toevaluatetheoptimumnetworkconfigurationheavycalculations
Thisispossibleonlybyusingtransformers.Infact,they havetobecarriedout.Inthislaboratorythebasiccircuitsofpower
aresuitableforsteppingupthevoltageofthegenerator engineering, series and parallel connections of operating
tovalueswhicharesuitableforhighvoltagesystems,for equipment (lines, transformers) as well as circuits involving the
power exchanging between networks, for stepping conversionofdeltaconnectionstostarconnectionsandviceversa,
downthevoltagestothemediumvoltagelevelandthen areanalyzed.
forfeedingthepowerintothelowvoltagenetwork.
In this laboratory a threewinding transformer is Also busbars, disconnectors, power circuit breakers, voltage and
investigated. It consists of three individual poles with current transformers are studied; these, in fact, are among the
different connection possibilities on the primary side mostimportantcomponentsofaswitchingstation.
and variable secondary voltage. The third winding
(tertiary winding) is designed as the delta stabilizing
windingneededforasymmetricalloads.
Overhead power lines are mainly used to transmit
electrical energy from the power stations to the ThreephasetransformerGTU102.1
consumers. However, in densely populated areas the
powercanonlybesuppliedviacables. determination of the vector group of the threephase
Bothmeansoftransmission,overheadlinesandcables, transformer
areincludedinthegeneraltermline. determination of the voltage transformation ratio of the
Today, the public supply of power takes place almost transformeroperatingatnoload
exclusively by means of threephase current with determination of the current transformation ratio of the
frequencyof50or60Hz,dependingupontheCountry. transformeroperatingwithshortcircuit
Duetothephaseshiftofthethreecurrentsinathree determinationoftheequivalentcircuitquantitiesbasedonthe
phasesystem,arotatingfieldiscreatedwhichisideal consumedactiveandreactivepower
forusebyconsumers.Furthermore,anotheradvantage measurementoftheeffectoftheloadtypeandmagnitudeon
of threephase systems is that they provide the theperformanceofthesecondaryvoltage
consumerswithtwodifferentlevelsofvoltage,sothat determinationoftheefficiencyofthetransformer
hecanusehisequipmentinthebesteconomicalway. investigation of the zeroimpedance of the threephase
Inthislaboratoryathreephasemodelofanoverhead transformerwithvariousconnectionmodes
powertransmissionline(withasimulatedlengthof360 examinationoftheloadcapacityofthesecondarysideusinga
kmlong,asimulatedvoltageof380kVandasimulated
singlephase load with different connection modes on the
currentof1000A)isused,withascalefactorof1:1000.
primaryside
The performance characteristics of the line are
determinationoftheinfluenceofadeltastabilizingwinding
investigatedundervariousloadconditions.Circuitcon
demonstration of the possibility of utilizing a threephase
figurationsarethenconnectedforthedemonstrationof
transformerineconomyconnection(autotransformer)
variousneutralpointconnectionsinthreephasemains
systems.Asymmetricalshortcircuitsarealsosimulated.
Questions regarding reactive power compensation are
finallyaddressed.But,transmissionnetworksrequirea
great number of lines and transformers as well as
switchgearsandsubstations.
Of course, because of the importance of electrical
power, special attention is paid to guaranteeing the
smoothoperationofallthetransmissiondevices.


ELECTRICALPOWERENGINEERING

OverheadlinemodelGTU102.2 investigation on the effect of parallel compensation
measurementofthevoltagesinnoloadoperation on the voltage stability at the load and the
conceptofoperatingcapacitance transmissionlossesoftheline
linemodelwithincreasedoperatingcapacitance investigationontheeffectofseriescompensationon
measurement of current and voltage relationship of an thevoltagestabilityattheload
use of measurement techniques to determine the
overheadlineinmatchedloadoperation;interpretationof
the terms: characteristic wave impedance, lagging and zerophasesequenceimpedanceoftheoverheadline
model and comparison of this value with the
leadingoperation,efficiencyandtransmissionlosses
theoreticalone
measurementandinterpretationofthecurrentandvoltage

ratios of a transmission line during a threephase short
circuit SeriesandparallelconnectionofHVlinesGTU102.3
measurementandinterpretationofthecurrentandvoltage measurement of the voltage distribution in the series
ratiosofatransmissionlinewithmixedohmicinductiveand connectionoftwolineswithoutoperatingcapacitances
pureinductiveloads measurement of the voltage distribution in the series
measurementandinterpretationofthecurrentandvoltage connectionoftwolineswithoperatingcapacitances
ratios of a transmission line with mixed ohmiccapacitive measurement of the voltage distribution in the parallel
andpurecapacitiveloads connectionoftwolineswithoutoperatingcapacitances
investigationontheperformanceofatransmissionlinewith measurement of the voltage distribution in the parallel
isolated neutral point connection in the case of a fault to connectionoftwolineswithoperatingcapacitances
earth
measurement of the earthfault current and the voltage BusbarsystemsGTU102.4
riseofthefaultyphases operation of a switching station with two busbars and
determination of the inductance of an earthfault differentvoltages
neutralizerfortheoverheadlinemodel busbar transfer with interruption of the power supply to
investigationontheperformanceofatransmissionline theconsumer
withafaultandcomparisonofthecurrentvalueswith busbar coupling and bus transfer without interruption of
those determined during earthfault with isolated thepowersupplytotheconsumer
neutralpointsystem switching sequence for disconnectors and power circuit
measurement of the fault currents of asymmetrical breakers
shortcircuitsandcomparisonoftheresultswiththose
forathreephasefault

GTU102.1 GTU102.2 GTU102.3 GTU102.4 TOTAL


Variablethreephasepowersupply DL1013T1 1 1 1 1
Linemodel DL7901TT 1 2 1 2
Threephasetransformer DL1080TT 1 1 1 1 1
Resistiveload DL1017R 1 1 1 1 1
Inductiveload DL1017L 1 1 1 1
Capacitiveload DL1017C 1 1 1
Threephasepowersupply DL2108TALSW 1 1 1
Powercircuitbreaker DL2108T02 1 1 4 4
Doublebusbarwithtwodisconnectors DL2108T02/2 1 1
Doublebusbarwithfourdisconnectors DL2108T02/4 1 1
Linecapacitor DL2108T03 2 2
Petersencoil DL2108T04 1 1
Movingcoilammeter(1005001000mA) DL2109T1A 1 1 1
Movingcoilammeter(1.252.5A) DL2109T2A5 2 3 3 3 3
Movingironvoltmeter(600V) DL2109T1PV 2 2 2
Movingironvoltmeter(125250500V) DL2109T3PV 2 3 3
Powermeter DL2109T26 2 1 2
Powerfactormeter DL2109T27 1 1
Connectingleads DL1155GTU 1 1 1 1 1
Table DL10011 1 1 1 1 1
Frame DL21003M 2 2 2 2 2
Accessory:Storagecabinet DL2100TA 1 1 1 1 1

ForCountrieswith3phasemainsdifferentfrom380V:
Threephasetransformer DL2100TT 1 1 1 1 1