Product description
Innovative firestopping solution for complex applications

Product features
Up to 6 times expansion of can yield
Repenetrable
Cures within 60 seconds
Easy handling for difficult to reach applications
Paintable
Virtually impervious to smoke
Mold resistant
No additional materials required Technical Data* CP 620
Execllent water vapor resistance Chemical basis Two component polyurethane

Meets LEED requirements for indoor environmental quality credit Color Red
4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints Fire foam yield Up to 110 in3
and Coatings Application temperature Substrate: 32F to 104F (0C to 40C)
Product: 50F to 104F (10C to 40C)
Areas of application Curing time* Non-tacky after Approx. 35 seconds
Sealing small to medium size openings Ready to cut after Approx. 1 minute
Cables and cable trays Thermal insulation (R-value) 2.83.0 per inch of thickness
Non-combustible pipes Temperature resistance of cured foam 22F to 212F (30C to 100C)
Combustible pipes when used in conjunction with Hilti Wrap Strips Sound transmission classification 50 (Relates to specific construction)
Where cables, steel, copper, cast iron or plastic pipes all pass (ASTM E90-97)
through the same opening Structure-borne sound insulation Pipe/wall 3050%

For use with floor and wall assemblies Surface burning characteristics Flame spread: 0
(ASTM E84-01) Smoke development: 15
Concrete, drywall and masonry
Tested in accordance with
Examples UL 1479 ASTM E 814 ASTM E 84 ASTM G21
Multiple penetrations *At 73F (23C) and 50% relative humidity
Insulated metal pipes
FILL, VOID OR CAVITY MATERIAL
FOR USE IN THROUGH-PENETRATION FM
FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY $33529('
66Y7 )RU3HQHWUDWLRQ)LUH6WRSV
&RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH

Installation instructions for CP 620


Notice 6. For maintenance reasons, the application can be Pieces of cured excess CP 620 Fire Foam which have
Before handling, read Material Safety Data Sheet and permanently marked with an installation plate. Mark been cut off can be laid in the next opening and fresh
product label for safe usage and health information. the installation plate and fasten it in a visible position CP 620 Fire Foam can be applied around these.
Instructions below are general guidelines always next to the seal.
Not for use
refer to the applicable drawing in the UL Fire Re-installing cables or pipes Exposed to weather
Resistance Directory or Hilti Firestop Systems Guide Additional cables or pipes can be installed later Exposed to UV
for complete installation information without difficulty.
Application Use a suitable tool to create an opening. Push the Storage
cable or pipe through and then seal the remaining Store only in the original packaging in a dry place
1-4.
opening carefully with CP 620 Fire Foam. at a temperature of 40F to 77F (5C to 25C).
Prepare dispenser and cartridges as shown below. See technical data for application and substrate
The Fire Foam from the first few strokes of the Notes temperatures. Partly-used cartridges can be stored
dispenser should be discarded until the Fire Foam in The CP 620 Fire Foam can be cut back to no less with mixer attached until they are required again.
the mixer has a consistent red color. than the minimum specified installation depth (see When re-using a partially used cartridge, simply
5. Apply the CP 620 Fire Foam in the opening. applicable UL systems for depths). attach a new mixer andOR
FILL, VOID dispense accordingly.
CAVITY MATERIALS
Begin applying CP 620 Fire Foam at the back of CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
the opening and work toward the front. Fill the FOR USE IN TROUGH-PENETRATION
opening completely with CP 620 Fire Foam. R FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
When dispensed slowly, the Fire Foam can be 66Y7
easily built up.
When dispensed quickly, the consistency of the
Fire Foam is more liquid allowing it to flow better Aus-
fhrungsschild

between the cables. Note: The CP 620 Fire Foam


1. Hold the cartridge 2. Fit the mixer and 3. Release the 4. Insert the cartridge 5. Apply CP 620 Fire 6. Attach the
becomes warm for a short time after application. in the upright position screw in a clockwise dispenser and pull in the dispenser. Foam, building up a seal installation plate
and unscrew the cap. motion until secure. back the piston rod. by working from the (if required).
back towards the front.

Hilti Firestop
Saving lives
through innovation
and education

Hilti. Outperform. Outlast.


Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com en espaol 1-800-879-5000 Hilti Firestop Systems Guide