INSTITUTO TECNOLOGICO SUPERIOR ZACATECAS

OCCIDENTE

VENTILACION DE MINAS
ING. ALFREDO GALINDO SORIANO

18 DE NOVIEMBRE DE 2016
ANAHI SUJEY ROMAN MORENO
TECNICO SUPERIOR EN MINERIA
VENTILADOR 24
DATOS FORMULAS
=24 P= diamtero* Q2

(ft) 2 ft Ps=Hl*Q2

Q=45 000 V=Q/A

K=20*10-10 lb/ft2 Pd=W(V/1098)

L=350 m = 1148 ft

Le= 10% = 1148ft (1.1) = 1262.8

A=7.06 ft2

9.42 ft

radio = 1ft

R=20*10-10 (6.28)(1262.8) = 1.58*10-5 = 9.83*10-8 (0.72)= 7.8*10-8

5.2(3.1416)3 161023

HL= 7.08*10-8 (45000)2 = 143.3inwa

V= ( 45000 ) = 14323.9 ft/min

3.1416

Pd=0.054 (14323.9) 2 =9.18 inwa

1098

Pt= 143.3 +9.18 = 152.5 inwa

Hp= (4500) (143.3) = 1016.64 Hp

6364

BHP= (4500) (143.3) = 1355.5 Hp

6364 (0.75)

SE REQUIERE UN MOTOR DE 1355.5 HP PARA PONERLO EN MARCHA


VENTILADOR 36
DATOS FORMULAS
=36 P= diamtero* Q2

(ft) 3ft Ps=Hl*Q2

Q=45 000 V=Q/A

K=20*10-10 lb/ft2 Pd=W(V/1098)

L=350 m = 1148 ft

Le= 10% = 1148ft (1.1) = 1262.8

A=7.06 ft2

9.42 ft

radio= 1.5 ft

R=20*10-10 (9.42)(1262.8) = 2.379*10-5 = 1.30*10-8 (0.72)= 9.36*10-9

5.2(7.06)3 1829.85

HL= 9.36*10-9 (45000)2 = 18.954 inwa

V= ( 45000 ) = 637309 ft/min

7.06

Pd=0.054 (637309) 2 =1.81 inwa

1098

Pt= 18.9 +1.81= 20.76 inwa

Hp= (4500) (18.9) = 134.4 Hp

6364

BHP= (4500) (18.9) = 179.2 Hp

4759.5

SE REQUIERE UN MOTOR DE 179.2HP PARA PONERLO EN MARCHA


VENTILADOR 42

DATOS FORMULAS
=42 P= diamtero* Q2

(ft) 3.5 ft Ps=Hl*Q2

Q=45 000 V=Q/A

K=20*10-10 lb/ft2 Pd=W(V/1098)

L=350 m = 1148 ft

Le= 10% = 1148ft (1.1) = 1262.8

A=7.06 ft2

9.42 ft
Radio= 1.75hp

R=20*10-10 (10.99)(1262.8) = 2.7756*10-5 = 15.995*10-9(0.72)= 4.31*10-9

5.2(9.62)3 4629.4

HL= 4.316*10-9 (45000)2 = 8.72 inwa

V= ( 45000 ) = 4677 ft/min

9.62

Pd=0.054 (4677) 2 =0.98 inwa

1098

Pt= 8.72+0.98= 9.7 inwa

Hp= (4500) (8.7) = 61.83Hp

6364

BHP= (4500) (8.72) = 82.44Hp

6364 (0.75)

SE REQUIERE UN MOTOR DE 82.44 HP PARA PONERLO EN MARCHA