FIRST
Presented to:
Mr.Hipni
Prepared by:
Yohanes Budi Hend(+62 8125426665)
CEMENT CALCULATION :
MAIN SLURRY 137 CUFT YIELD 1.150 CUFT/SX VOLUME 119 SACKS
MATERIAL REQUIREMENT :
ADDITIVES/ MAIN 15.85 PPG
PRODUCTS CONCENTRATION
CEMENT 119 SACKS
GEL 0.000 % bwoc 0 LBS
CACL2 1.000 % bwoc 112 LBS
R-21LS 0.000 GPS 0 GALS
FL-45LS 0.000 GPS 0 GALS
CD-31L 0.000 GPS 0 GALS
BA-58L 0.000 GPS 0 GALS
FP-9LS 0.030 GPS 3 GALS
A-300L 0.000 GPS 0 GALS
SLURRY SYSTEM :
Class "G" cement + 1.00 % (db-bwoc) CaCl2, Accelerator
+ 0.030 GPS FP-9LS, Foam Preventer
TEST RESULTS
Thickening Time at 97 deg.F. : 2 : 36 (40 BC), 3 : 13 (70 BC), 3 : 53 (100 BC)
Fluid Loss at 97 deg.F. : N/A
Free water at 97 deg.F. : 0% by volume
Fann 35 readings (R1,B1,F=1) : 300 200 100 6 3 Pv Yp
@ after Mixing : 67 53 39 22 15 42 25
@ BHCT : 124 110 88 44 34 54 70
DISTRIBUTED TO PERTAMINA - BJ
NOTICE : This report is the property of PT BJ SERVICES INDONESIA, Any user of the rep
This report is the property of BJ
SERVICES, and is intended for private
information of the named party. This
report nor any part thereof may not be
published or disclosed to a third party
without the written approval of PT.BJ
SERVICES INDONESIA
s the property of PT BJ SERVICES INDONESIA, Any user of the report agrees that PT BJ
UB PERTAMINA EP TANJUNG
CEMENTING PROGRAM AND PROCEDURE
Well Name : T-162
October 21, 2009
. RUN CENTRALIZER PROGRAM AS PER PERTAMINA PROGRAM. BJ SERVICES RECOMMEND TO RUN 1EA
CENTRALIZER PER 2 JOINT OF CASING.
. RUN CASING AS PER PERTAMINA PROGRAM.
. PRESSURE TEST CEMENT LINE TO 2500 PSI FOR 5 MINITES.
. PUMP THE FOLLOWING PREFLUSH
TYPE OF FLUID VOLUME DENSITY RATE (BPM)
WATER AHEAD 20 BBL 8.34 PPG .
. MIX AND PUMP CEMENT SLURRY AS FOLLOW
TYPE OF SLURRY VOLUME DENSITY RATE (BPM)
TAIL 24 BBL 15.80 PPG .
. END JOB
PT. BJ SERVICES INDONESIA
CEMENT RECOMMENDATION AND CALCULATION
UB PERTAMINA EP TANJUNG
Well Name : T-162
October 21, 2009
Objectiv9-5/8" Casing will be cemented up to surface. Job time is 54 minute. Thickening time approximately 3
LEAD SLURRY :
Class "G" cement + 1.00 % (ph-bwoc) Gel, Extender
+ 1.00 % (ph-bwoc) CaCl2, Accelerator
+ 0.300 GPS A-300L, Strength Enhancer
+ 0.010 GPS FP-9LS, Defoamer
TEST RESULTS
Thickening Time at 100 deg.F. : 3 : 21 (70 BC)
Fluid Loss at 100 deg.F. : N/A
Free water at 100 deg.F. : 0.85% by volume
Fann 35 readings (R1,B1,F=1) : 300 200 100 6 3 Pv Yp
@ after Mixing : 54 40 26 10 8 42 12
@ BHCT : 62 47 31 14 12 46.5 15.5
Cement/Additives/Water : Holcim "G" & Water from Location - Additives from Lab Stock
NOTICE : This report is the property of PT BJ SERVICES INDONESIA, Any user of the rep
NOTICE : This report is the property of PT BJ SERVICES INDONESIA, Any user of the rep
TAIL SLURRY :
Class "G" cement + 0.75 % (ph-bwoc) CaCl2, Accelerator
+ 0.030 GPS FP-9LS, Defoamer
TEST RESULTS
Thickening Time at 100 deg.F. : 3 : 12 (70 BC)
Fluid Loss at 100 deg.F. : N/C
Free water at 100 deg.F. : 0.9% by volume
Fann 35 readings (R1,B1,F=1) : 300 200 100 6 3 Pv Yp
@ after Mixing : 73 54 36 16 14 56 18
the property of PT BJ SERVICES INDONESIA, Any user of the report agrees that PT BJ
the property of PT BJ SERVICES INDONESIA, Any user of the report agrees that PT BJ
2
UB PERTAMINA EP TANJUNG
CEMENTING PROGRAM AND PROCEDURE
Well Name : T-162
October 21, 2009
. RUN CENTRALIZER PROGRAM AS PER PERTAMINA PROGRAM. BJ SERVICES RECOMMEND TO RUN 1EA
CENTRALIZER PER 2 JOINT OF CASING.
. RUN CASING AS PER PERTAMINA PROGRAM. PERFORM MUD CIRCULATION WHEN THE CASING REACH
PREVIOUS CASING SHOE.
3 WHEN THE CASING AT BOTTOM HOLE, PERFORM MUD CONDITIONING BY REDUCING YP OF THE DRILLING
MUD AS LOW AS APPLICABLE. RECIPROCATE CASING WHILE MUD CONDITIONING. THREE BOTTOM-UP
VOLUME IS RECOMMENDED TO HELP MUD REMOVAL. MAKE SURE NO LOSS IN THE WELL.
. RIG UP CEMENTING HEAD AND MANIFOLD. USE "Y" AND TWO HAMER VALVES ON THE RIG FLOOR TO
EASILY SWITCH FROM CEMENT LINE TO MUD LINE
. IF THE FLOATS IS LEAKING THEN PUMP THE RETURNED VOLUME BACK TO THE WELL AND CLOSE THE
VALVE ON THE CEMENTING HEAD AND HOLD FOR 6 HRS.
. IF THE FLOAT WORKING PROPERLY, OPEN CEMENT HEAD MANIFOLD VALVE DURING WOC
. WAIT ON CEMENT
15 END OF JOB
PT. BJ SERVICES INDONESIA
CEMENT RECOMMENDATION AND CALCULATION
UB PERTAMINA EP TANJUNG
Well Name : T-162
October 21, 2009
Objectiv The 1st stage will cement 7" casing from TD to DSCC (740.7 meter). Estimate job time is 91
minute. Thickening time approximately 3 - 3.5 hours.
CEMENT CALCULATION :
7-7/8 in Casing Shoe @ MAIN SLURRY #N/A CUFT YIELD 1.179 CUFT/SX VOLUME #N/A SACKS
830 Ft
253 m
MIXING WATER 3.807 GPS #N/A BBL TOTAL SLURRY:
MIXING FLUID 5.277 GPS #N/A BBL MAIN SLURR #N/A BBLS
Float Collar
o 4,570 Ft
1392.80 m
-7/1 in Casing Shoe @
4,652 Ft
1418.0 m
PT. BJ SERVICES INDONESIA
CEMENT RECOMMENDATION AND CALCULATION
UB PERTAMINA EP TANJUNG
Well Name : T-162
October 21, 2009
Objectiv The 2nd stage will cement 7" casing from DSCC to SURFACE mTVD. Estimate job time is 75
minute. Thickening time approximately 3.5 hours.
CEMENT CALCULATION :
7-7/8 in Casing Shoe @ MAIN SLURRY #N/A CUFT YIELD 1.652 CUFT/SX VOLUME #N/A SACKS
830 Ft
253 m
MIXING WATER 7.509 GPS #N/A BBL TOTAL SLURRY:
MIXING FLUID 8.821 GPS #N/A BBL MAIN SLURR #N/A BBLS
Float Collar
o 4,570 Ft
1392.80 m
-7/1 in Casing Shoe @
4,652 Ft
1418 m
This report is property of BJ SE
and is intended for private inform
the below named party. This re
any part thereof may be publ
PT BJ SERVICES INDONESIA disclosed to a third party wit
written approval of PT.BJ SE
LABORATORY REPORT INDONESIA
FIRST STAGE :
Depth : 1418 Meters (MD)
Depth : 1400 Meters (TVD)
B.H.S.T : 160 deg. F
B.H.C.T : 122 deg. F (Pertamina - API Casing Schedule)
T.G. : 1.75 deg. F/100 feet
SLURRY SYSTEM
Class "G" cement + 0.900 gps FL-45LS, Fluidloss Additive
+ 0.080 gps CD-31L, Dispersant
+ 0.060 gps R-21LS, Retarder
+ 0.400 gps BA-58L, Bonding Agent
+ 0.030 gps FP-9LS, Foam preventer
TEST RESULTS
Thickening Time at 122 deg. F. : 3 : 16 (40 Bc) _ 3 : 28 (70 Bc) _ 3 : 40 (100 Bc)
Fluid Loss at 122 deg. F. : 48 cc/30 min./1000 psi
Free Water at 122 deg. F. : 0 % by volume (with 45% inclination)
Fann 35 readings (R1,B1,F=1) : 300 200 100 6 3 Pv Yp
@ after Mixing : 147 101 54 9 7 139.5 7.5
@ BHCT : 162 114 63 8 7 148.5 13.5
NOTICE : This report is the property of PT BJ SERVICES INDONESIA, Any user of the report
agrees that PT BJ SERVICES INDONESIA. Shall not be liable for any loss or damage which result
from the use of the information in the report PT BJ SERVICES INDONESIA make no warranties in
NOTICE : This report is the property of PT BJ SERVICES INDONESIA, Any user of the report
agrees that PT BJ SERVICES INDONESIA. Shall not be liable for any loss or damage which result
from the use of the information in the report PT BJ SERVICES INDONESIA make no warranties in
SECOND STAGE :
Depth : 740.7 Meters (MD)
Depth : 725 Meters (TVD)
B.H.S.T : 122 deg. F
B.H.C.T : 96 deg. F (Pertamina - API Casing Schedule)
T.G. : 1.75 deg. F/100 feet
SLURRY SYSTEM
Class "G" cement + 1.00 % (ph-bwoc) GEL, Extender
+ 0.700 gps FL-45LS, Fluid Loss Additive
+ 0.050 gps CD-31LS, Dispersant
+ 0.010 gps R-21LS, Retarder
+ 0.500 gps BA-58L, Bonding Agent
+ 0.010 gps FP-9LS, Defoamer
TEST RESULTS
Thickening Time at 96 deg. F. : 3 : 39 (40 Bc) _ 4 : 12 (70 Bc) _ 4 : 38 (100 Bc)
Fluid Loss at 96 deg. F. : 287 cc/30 min./1000 psi
Free Water at 96 deg. F. : 0.1 % by volume
Fann 35 readings (R1,B1,F=1) : 300 200 100 6 3 Pv Yp
@ after Mixing : 22 17 11 6 5 16.5 5.5
@ BHCT 60 48 37 24 23 34.5 25.5
11-Oct-09
2
UB PERTAMINA EP TANJUNG
CEMENTING PROGRAM AND PROCEDURE
Well Name : T-162
October 21, 2009
4 PERFORM FLUID CALLIPER. MAKE SURE THE MUD VOLUME IN AND OUT THE WELLBORE IS THE SAME
. RIG UP CEMENTING HEAD AND MANIFOLD. USE "Y" AND TWO HAMER VALVES ON THE RIG FLOOR TO
EASILY SWITCH FROM CEMENT LINE TO MUD LINE
. PRESSURE TEST CEMENT LINE TO 3000 PSI FOR 5 MINUTES.
. PUMP THE FOLLOWING PREFLUSH (ALWAYS RECIPROCATE THE CASING DURING THE PUMPING UNTILL
THE PLUG IS BUMPED)
TYPE OF FLUID VOLUME DENSITY RATE (BPM)
MCS SPACER 80 BBL 10.04 PPG .
MUD WASH 30 BBL 8.34 PPG .
NOTE : SPACER SHOULD 1 PPG OVER MUD WEIGHT
Mud
Weight : 9.42 PPG
MCS Spacer
Drill water 35.4 gal/bbl 2833.475 gals 67.5 BBL Drill water
FP-9LS 1 gal/bbl 80 gals 1.9 BBL FP-9LS
GW-23 1 lb/bbl 80 lbs 80.0 Lbs GW-23
Barite 90 lb/bbl 7200 lbs 7,200.0 Lbs Barite
MCS-A 1 gal/bbl 80 gals 1.9 BBL MCS-A
CD-31L 2 gal/bbl 160 gals 3.8 BBL CD-31L
Sub-total 6.58
Total
35.42 295.39
1 6.92
0.07 1.00
2.51 90.00
1 8.84
2 19.52
42.00 421.7
PRODUCT DISCUSSION
Safe and environmentally friendly cement additive, designed to provide ease of use,
in terms of field mixing and handling, while meeting rigorous standards of
environmental compliance. A-300L, acts primarily as a slurry strength enhancer but
also exhibits some accelerating effects, in terms of shortening thickening time. When
A-300L used alone or combined with other additives, A-300L substantially increase both
early and late compressive strength of all cement slurries. In addition, A-300L acts to
stabilise lower density slurries and, exhibits synergistic effects when combined with
dispersants and fluid-loss control additives. A-300L can be used in fresh or seawater
for slurries ranging from 11.0 ppg to 16.0 ppg.
A liquid fluid loss additive, designed to prevent the problems associated with filtrate
loss of cement slurry for bottomhole circulating temperatures, ranging from 80F to
300F. A highly versatile product, FL-45LN/FL-45LS is an anionic blend of high
FL-45LS molecular weight synthetic copolymer and surfactant that will control fluid loss in
cement slurries by absorption and conformation of macro molecules at the
solid/solution interface, in other words, it will attach to the cement particles and
thicken the interstitial water.
Dispersant, a dark brown liquid, composed primary of a highly polymerized
naphthalene sullonate. It is used to thin cement slurries so that turbulent flow can be
CD-31L achieved at a reasonable low pump rate, it is also use to densify slurries up to 17.5
ppg, resulting in heavier, stronger cement.
An anionic blend of organic acid salts. When mixed with cement it will absorb into
the cement particles and chelate the calcium ions retarding formation on CSH gels.
R-21LS has a slight dispersive action with most cements, which results in some
R-21LS thinning of cement slurry. Due to this, better fluid loss control is generally obtained.
It can be use as a retarder with slurries prepared with either fresh water or
sea`water. It used at temperature range of 120 F to 350 F.
Gas block additive, a water suspension of tiny silica particles with average size of 0.8
microns it effectively reduce the internal permeability of the cement by chemically
BA-58L and physically blocking the slurries matrix. These include fluid loss materials and the
slurries' ability to prevent gas migration. The material is very versatile and can be
used with equal effectiveness in fresh or sea water.
Liquid defoamer, light yellow fluid, defoamer for cement slurries. It is very effective
FP-9LS and long lasting defoamer for cement slurries. It prevent the formation of foam or
destroys the foam immediately if added when foaming has commenced
SERVICES OPERATION REPORT
1. CLIENT: PERTAMINA 9. PROJECT: 9-5/8" CSG CMT 16. DATE: 25-Aug-09 SOR # 825673
2. CITY: TANJUNG 10. WELL #: T-160 17. DIST/LOC CODE: KPT 21. MAX DEPTH: 0 FT
3. COUNTRY: INDONESIA 11. FIELD: TANJUNG 18. JOB W/EVENT: Y N 22. KM (ONE WAY):
4. CLIENT #: 12. WELL: NEW OLD 19. WELL TYPE: EXP DEV W/O R/L
5. PURCHASE ORDER #: 13. OFFSHORE ONSHORE 20. OIL GAS OTHERS 23. MMP: Y N
6. EQT USED: BJ 3RD PARTY 14. SERVICES PERF 1 (SEE BELOW FOR CODE) 24. MAX PRESS.: PSI
7. MAT USED: BJ 3RD PARTY 15. APPLICABLE PRICE LIST: 82 89 90 25. ENGINEER: SAROSO
8. # OF BJ PERSONNEL ON JOB: SUP SE HEL MECH EO TECH MANAGER 26. PERSONNEL CODE:
TOOL COST 0.00 Set up Charge for Tools JOB 990.00 0.00
0.00 RBP Rental Charges Hr 49.50 0.00
0.00 Packer Rental Charges Hr 49.50 0.00
PRODUCT COST
32. DATE August 25, 2009 36. PER Hrs ASSISTEN MANAGER OPERASI
SERVICE CODE:
CEMENT PRIMARY 01 HANDLING 05 MATRIX ACIDIZING 09 SAND CONTROL 13 WELL KILL 17
CEMENT REMEDIAL 02 CEMENT MATERIAL 06 STIM. MATERIAL 10 GRAVEL PACK 14 DST 18
CEMENT PLUG 03 DOWNHOLE TOOLS 07 STIMULATION TOOLS 11 SAND CONTROL MAT'L 15 NITROGEN 19
GROUTING 04 FRACTURING 08 COILED TUBING 12 MISC PUMPING 16 RENTAL/OTHERS 20
CUSTOMER (ORG) REGION (PINK) / DISTRICT (YELLOW) / STATION (GREEN) / INVOICE (BLUE) FILTRATION 21
DELIVERY TICKET
P.T. BJ. SEVICES INDONESIA DT- 712767
Jl. Ampera Raya No. 9 - 10
Jakarta 12550, Indonesia
CARRIER NAME :
DISTRIBUTION :
WHITE - CUSTOMER, BLUE - ACCOUNTING, YELLOW - ORIGINATOR, PINK - CUSTOMER, GREEN - ACCOUNTING, PINK - LOGISTIC