Get the Most From


Your Fired Heater
Though the functioning of these widely used heat-
ers it appears simple, there is more to efficient
operation than meets the eye. A common stum-
bling block is the control of draft.

Ashutosh Garg
Furnace Improvements

Fired heaters are major consumers of en- savings of almost $500,000/yr. Automatic Combustion
ergy in the chemical process industries draft control can improve the efficiency of Combustion, the exothermic reaction re-
(CPI) especially at petroleum refineries fired heaters if it is designed and installed sulting from rapid combination of fuel with
and petrochemical plants. Accounting for correctly. Before explaining how, we pro- oxygen, produces heat and flue gases. Fuel
as much as 70% of total plant energy con- vide a brief refresher on the concepts in- and air must be mixed thoroughly for com-
sumption in some instances. While most volved. plete combustion. In theory, it is possible
plant engineers and operators are aware of to burn fuel completely with just the
the importance of controlling excess oxy- Fired Heaters stoichiometric amount of combustion air.
gen in fired heaters, they often overlook a In a fired heater, the thermal energy liber- However, under actual operating condi-
key determinant of efficient heater opera- ated by the combustion of fuel is trans- tions, perfect mixing of fuel and air is not
tion; the control of their draft, namely, the ferred to fluids contained in tubular coils possible within the short time that is in-
negative pressure inside the vessel with within an internally insulated enclosure. volved in combustion. If only the theoreti-
respect to the atmosphere. A typical fired heater consists of cal amount of combustion air were pro-
A recent survey indicates two three major components; the radiant sec- vided, then some fuel would not burn com-
extremes in draft management. In most tion, the convection section and the stack. pletely. So, excess air is needed, expressed
fired heaters, the draft is maintained at Figure 1 shows a typical cross-sectional as a percentage of the theoretical quantity
almost four times the value recommended. view of a vertical cylindrical fired heater. of air required for perfect combustion. This
At the other end of the spectrum, some The fired heater is fired by oil or gaseous excess air shows up as excess oxygen in
heaters run with no draft in fact, with fuel. The process fluid, passing through the flue gas. Table 1 shows the effects of
positive pressure at the radiant arch (the tubes in the heater, absorbs the heat mostly excess air and stack temperature on the
transition zone between the radiant and by radiant heat transfer, and by convective thermal efficiency of the fired heater. As a
convection sections). Neither situation is heat transfer from the flue gases. rule of thumb, every 10% increase in ex-
desirable; they can cause considerable loss The flue gases are vented to the cess air reduces the heater efficiency by
of energy, and can even be hazardous. atmosphere through the stack. Burners are almost 1%, whereas every 35oF reduction
Plants can save substantial amounts of en- located on the floor (as stylized in Figure in stack flue gas temperature increases
ergy by training operators in proper draft 1) or on the sidewalls of the heaters. Com- efficiency by 1%.
control and making minor hardware modi- bustion air is drawn from the atmosphere.
fications. For a 100,000-bbl/d (BPD) refin- Combustion is directly affected by the Burners
ery in the U.S., even a 1% improvements draft. Burners start and maintain combustion, in
in thermal efficiency translates into energy the firebox. They introduce fuel and air in
the correct proportions and mix them, pro-

Furnace Improvements Services


www.heatflux.com 1
Get the most from your Fired Heater

vide a source of ignition, and stabilize than (and thus at lower pressure than) the Natural Draft: As implied above, this is
the flame. How the air is supplied to the colder ambient air outside. the most common system (Figure 2). Air
burners is largely related to the concept In a given situation, the theo- is drawn into the burners by means of
of draft, discussed in more detail now. retically available draft, in inches of wa- the draft created by the radiant section.
In most fired heaters, the burn- ter column (inWC ) can be calculated as The taller this section, the greater the
ers are natural draft, as explained below. follows: available draft. Typical draft gains are of
These burners are the most dependent on the order of 0.1 inW.C. per 10 feet of
the draft, as all natural draft burners are Draft = 0.53 HP [(1/ Tambient) (1/ Tflue gas)] box height in the radiant section.
sized for a specific draft loss across the Draft at the heater floor is the
burner. Providing a higher draft than that Where H is stack height in feet, P is at- order of 0.3 to 0.7 in. for tall, vertical
design value will induce more air, mospheric pressure in pounds per square cylindrical heaters. Natural draft is the
whereas providing lower draft will lead inch absolute (psia). Tambient is the ambi- most simple and reliable type of heater,
to insufficient air for combustion. ent temperature in degrees Rankine and as the air supply does not fail. System
The other type of burners used Tflue gas is the flue gas temperature, in the performance is directly linked to the
in fired heaters is forced-draft burners same units. draft available in the heater. In these
which get their air supply from a fan. Combustion air is drawn into heaters, draft control is the most impor-
These are not dependent on the heater the burners from the atmosphere, and hot tant operating parameter.
draft. gas rises due to buoyancy and flows out
There are also self-inspirating of the stack to the atmosphere. While Forced-Draft: In this type of heater, the
pre-mix burners, used in special heaters passing through the heaters convection air is supplied by means of a centrifugal
such as those for steam methane reform- section and the stack, flue gases encoun- fan, commonly known as a forced-draft
ing, or for ethane cracking. Most of these ter friction resistance, known collec- (FD) fan. A FD fan provides air at rela-
burners are partially dependent on the tively as draft losses. Sufficient stack tively high pressure, in the range of 2 to
draft available in the heater. height is given to provide the buoyancy 6 in.WC , leading to better air-fuel mix-
effect needed to overcome these losses, ing and smaller burners.
Draft and to ensure that pressure is always In this option, too, the stack is
Draft is the pressure differential between negative inside the firebox. required to create a negative draft inside
air or flue gas in the heater and ambient There are four types of draft the fired heater.Draft control is impor-
air. It materializes because hot flue gases systems in the fired heaters: tant in these heaters, to minimize air
inside the firebox and stack are lighter

Furnace Improvements Services


www.heatflux.com 2
Get the most from your Fired Heater

leakage and to ensure negative pres- with a fired heater, the combination is known the radiant section. In the convection
sure throughout the whole heater. as a balanced-draft system. Most air preheat- section, flue gases admittedly encounter
ing installations are, in fact, balanced draft. resistance due to tubes, but gain some
Induced-Draft: When the height of In a typical air preheating system, the draft due to the height of this section. If
the stack is inadequate to compen- draft loss across the air preheater could be on the convection section becomes fouled,
sate for the draft-loss requirements, the order of 2-6 inWC. The stack by itself the pressure drop across that section
an induced-draft (ID) fan is provided cannot compensate for a loss of this magni- goes up and the draft at the arch can, in
on top of the fired heater (Figure 3). tude. Instead, the FD fan supplies the combus- fact, becomes positive.
The resulting negative pressure in- tion air, and the ID fan takes care of flue gas Similarly in the stack, the stack
side the heater ensures adequate disposal. In these systems, draft control is re- controls the draft. If the damper is closed
draft for the burners from the atmos- quired for efficient combustion. Figure 4 too far, the arch draft will become posi-
phere. Most heaters in cracking and shows a typical balanced-draft heater with an tive; if it is instead opened too far, it will
reforming units fall into this cate- air preheating system. lead a very high draft in the arch. The
gory. The size of the convection sec- right stack height provides the draft need
tion in these fired heaters is very Draft Profile to maintain negative pressure at the arch
large, and the draft control is very Maintaining a negative pressure at all times and to take care of friction losses in the
important. throughout the fired heater makes the device convections section and stack.
inherently safe, and ensures that hot flue gases
Balanced-Draft: When both forced- will at no time escape. By contrast, a positive Draft Control
draft and induced-draft fans are used pressure inside the heater can be hazardous for In natural or forced-draft systems, the
operating personnel, would draft in the fired heater is controlled by
cause flue gas leakage, as well the means of a stack damper, as just dis-
as damage to the fired-heater cussed. In induced-draft and balanced-
casing and overall structure. draft heaters, the draft is controlled by
The typical draft profile ID fan. Because the arch of the heater
for a balanced-draft heater ap- has the highest pressure, it is commonly
pears in Figure 5. Other types of used as a point of control.
heaters have similar profiles, A value of 0.1 in W.C. is typi-
except for some minor variations cally maintained at the arch in all fired
associated with the (lone) ID or heaters, except for some special, down-
FD fan installation. fired reformer heaters. This value en-
As can be seen from the sures safe operation and minimal air
draft profile, the radiant arch of leakage. Excess air must be minimized
the heater sees the highest abso- for efficiency improvement. On the other
lute pressure throughout the hand, enough air must be provided to
whole heater, except for the obtain the correct and desirable flame
stack tip. If draft at the arch can shape and complete combustion. Closing
be controlled to be negative, the air registers reduces air flow but in-
engineer can be sure that the creases heater draft. Closing the stack
entire heater will be at negative damper reduces the fired-heater draft. In
pressure. order to regulate excess air effectively,
The floor of the heater the damper and registers must be ad-
or the hearth, where the burners justed jointly.
are typically located, experience
draft due to the stack effect in

Furnace Improvements Services


www.heatflux.com 3
Get the most from your Fired Heater

Air Leakage
A fired heater is not a pressure-tight
structure. Air can leak into the
heater through all openings avail-
able to it. This air does not take part
in combustion, instead showing up
in the stack. It can lead to ineffi-
cient combustion, to a waste of en-
ergy due to excess draft, and to the
generation of NOx emissions*.
Even with fuel prices at only $3
million Btu, one square inch of
leakage area can lead to $32,000 in
energy cost per 0.1 in W.C. of ex-
cess draft.
These precautions can
minimize air leakage a fired heater:

Keep all peepholes closed.

Make sure that the doors are


tight on the header box, which
houses fluid-tubing U bends in
the convection section.

Keep the explosion door


closed.

Ensure there is only minimal


air leakage via the penetrations
of the tube guides (which hold
the fluid tubes in place) into the NOx burners or raw gas burners (in
floor of the heater. which the fuel gas and air become
One reliable indication of air mixed, externally, at the burner tip);
leakage is the production of CO even at both versions, unlike the premix burn-
high oxygen levels. Carbon monoxide ers, are draft-dependent. Therefore,
will be generated at the burners if the air these heaters need to provide the re-
to them is insufficient, but the leaked air quired draft. Old fired heaters that
(which does not help the burners) raises have not been thus modified are the
the oxygen content of flue gases and thus most-significant sources of fired-
masks that insufficiency. heater energy loss today.

Typical heater configurations Heater with stack damper: Most fired


Several heater and damper configura- heaters installed in the last 30 years
tions can be found in chemical process fall in this category, having been de-
plants: signed with a manually operated stack
damper.
Fired heater with no stack damper: The damper is typically oper-
Heaters of this type were built in the ated from grade, by means of a cable
1950s and 1960s. The burners installed and a winch. The damper is provided
in these heaters were typically of the with an external position indicator;
premix version; in these burners; the also, the winch is calibrated.
amount of air inspirited is automatically
proportional to the fuel gas pressure.
Overtime, however, the burners in such
heaters became replaced by either low-
*Conversely, if the draft in the heater is
(unfortunately) positive, hot gases from the
Furnace Improvements Services
www.heatflux.com 4
Get the most from your Fired Heater

firebox can leak out through the openings, which that could change the flue gas flow pattern
poses a safety hazard.
in the furnace. Heaters with ID fan: The two types of
heaters that use ID fans to maintain
However, dampers of this type are of poor Multiple heaters with common stack: the draft in the heater are: induced-
quality; they often get stuck, and sometime Similarly, in several installations, a num- draft fired heaters, as discussed earlier;
remain fully open. Operators tend to be ber of heaters are connected to a common and balanced-draft fired heaters with
reluctant to touch them so as to make ad- stack (Figure 6). This configuration is par- air-preheating systems.
justment to drafts. These dampers should ticularly common in Europe, where the In both types, the draft is
be replaced with more-reliable versions, local pollution laws may dictate using a controlled by the fan. Generally, the
whether manually or pneumatic operated, stack as high as 200 to 300 ft. Such stacks fans are provided with an inlet-box
from grade or at a control panel. are based upon grade, and the fired heaters damper to control the draft; in some
are connected through the ductwork. cases, the fan is instead provided with
Heaters with off-take dampers: A number In these installations, the draft a variable-sped drive (VFD) for that
of cabin-type fired heaters with long con- control becomes tricky. Any change in the purpose. Furthermore, some installa-
vection sections are equipped with single firing conditions of one heater can affect tions have a VFD on the ID fan, as
or multiple off-take ducts, which connect the draft in all the other heaters and require well as a damper in the ID suction to
the convection sections to the stack. In their readjustment. In such circumstances, control the draft. As a damper in the
some such heaters, the dampers are in- it is common to have an automatic draft ID suction to control the draft.
stalled in the off-takes instead of stack. control system for each heater. An alterna- Heaters with ID fans are gen-
Multiple off-take dampers should be oper- tive consists of having a manual loading erally large, so it is especially impor-
ated uniformly, as to avoid any imbalance station, along with pressure indicators, in tant that the correct draft be main-
the control room. tained. Due to the large number of

Furnace Improvements Services


www.heatflux.com 5
Get the most from your Fired Heater

burners and peepholes in large heaters, is that most of the points are not easily move to the position specified by the
high draft can readily affect the opera- accessible. Another common approach is purchaser in the event of control signal
tion adversely. to bring all the (pneumatic) gauge con- failure or motive force failure.
nections to ground level, and then install It is also important to check
Draft Control separate draft gauges there. the stack damper at every shutdown,
Controlling draft requires the following A third variation, rather com- make sure it is working properly, and
instruments and hardware: monly employed, is to manifold all the make repairs or modifications as
connections and install a single draft needed. Damper operation is especially
Draft gauges: These gauges are simple gauge. This option is economical, but it critical if the heater has an air preheat-
instruments designed to measure draft requires the operator to open and close ing system; in this case, a tight-shutoff,
or differential pressure. Typical draft- valves every time the draft must be quick-acting damper should be em-
gauge locations in a fired heater are as checked. ployed.
shown in Figure 7. An advanced approach is to Many plants using air pre-
install pressure transmitters at the arch heaters tend to keep the stack damper
Heater floor: A minimum of two gauges and send the signal to the control room; slightly open, for the fear of it getting
are recommended for the heater floor. in this case, the other draft gauges are stuck.
usually field-installed. But as a result, either cold flue
Heater arch: Having at least two gauges Regardless of the installation gas starts recirculating back into the
at the heater arch or at the convection option chosen, it is important that the system or the hot flue gas leaks into the
section inlet is likewise recommended. gauges have a correct range. Failure to atmosphere. Both of these scenarios
meet this simple requirement is among cause a loss of efficiency. Instead, the
Convection section exit: Gauges here the most common problems found with damper should be kept fully closed, and
serve to check the total draft loss across fired heaters in the field. its motion should be tested every two
the convection section. The minimum weeks.
recommendation is one draft gauge, Stack Damper Reliability
right above the stack damper. As an The American Petroleum Institutes API Automatic Draft Control
alternative, an arrangement with two 560 code specifies several requirements As noted above, draft in fired heaters
gauges (above and below the damper) is for a good stack damper. For example, it can be controlled automatically. One
useful monitoring the stack damper is requires one blade for every 13 ft2 of control scheme is shown in Figure 8.
adjusted, the draft upstream and down- internal cross-section area. The blades Although automatic draft control often
stream will change. should be of equal area, with their move- suffered from damper-quality, pressure-
ments opposed. measurement and other problems in the
Installation options: These are several The code also calls for the past, improvements in equipment qual-
prevalent practices for installing draft damper controls to be provided with ex- ity have removed risks.
gauges. For instance, each gauge con- ternal position indicators, and they
nection can be made locally; a drawback should be designed so that the dampers

Edited by Nicholas P. Chopey

The Author
Ashutosh Garg is a senior Thermal Engineer at Furnace Improvements (Sugar Land, Texas; Tel 281-980-
0325; Fax: 832-886-1665; email: agarg@heatflux.com). He has almost 30 years of experience in design,
engineering, and troubleshooting of fired heaters and combustion systems. He began his career as a gradu-
ate engineer in an ammonia plant; this work was followed by six years in KTI India and eight years at EIL,
New Delhi, in the latter firms heater group. For the past seven years, he has been with Furnace Improve-
ments, where he provides services to the petroleum refining and petrochemical industries related to fired heat-
ers and NOx emissions reduction. He has published several papers on those two topics in trade magazines. A
registered professional engineer and a member of AIChE, he is a member of API subcommittee on heat transfer. He holds de-
gree in chemical engineering from Indian Institute of Technology, Kanpur, India.